首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A series of diastereomeric 4S,5S,6R/S-tetrahydropyrano- and 3S,4S,5R/S-tetrahydrofuranochromenylamine derivatives (a/b isomers; 1-26) has been studied under electron ionization (EI) and chemical ionization (CI) conditions. The EI mass spectra of all diastereomeric compounds show two characteristic fragment ions, of which one is formed by retro-Diels-Alder (RDA) reaction from the molecular ion, retaining the charge on the diene fragment, and the other [M-(HNAr)]+ ion by a simple radical loss. The RDA process is more favorable in all b isomers, whereas the radical loss is dominant in all a isomers; based on these two ions it is easy to differentiate the two diastereomers. The collision-induced dissociation (CID) spectra of all the molecular ions also show the same trend, which reflects the stereoselectivity in the formation of the two characteristic fragment ions. The results of theoretical calculations performed are in accordance with the experimental observations. The CI experiments (methane and isobutane) on all the diastereomeric compounds also enabled the differentiation of the isomers.  相似文献   

2.
Analytical Chemistry Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA Ion-molecule reactions of neutral methane with analyte ions under normal methane chemical ionization conditions are discussed. Reactant ions can be generated by direct electron ionization (EI) fragmentation, chemical ionization (CI) fragmentation, or collision-induced dissociation (CID). Examples in which products of such reactions appear in mass spectra in both conventional CI sources in “beam” instruments and low pressure CI in a quadrupole ion trap are presented. Also shown is an example in which MS/MS product ions react with neutral methane used for CI in an ion trap. It is shown that it is relatively straightforward to recognize such reactions in a quadrupole ion trap and in certain cases to minimize or preclude them. Effects of various operating parameters have been investigated and are discussed.  相似文献   

3.
This study presents the self-ion/molecule reaction (SIMR) spectra of three xylene isomers, and proposes an approach to differentiating them based on observed differences in relative abundances of ions formed by SIMR in an internal source ion trap instrument. It also demonstrates the applicability of SIMR for isomer discrimination, which is better than electron ionization (EI) and dimethyl ether chemical ionization (DME CI) in an ion trap mass spectrometer (ITMS) since no CI reagent, metal ions or internal standards are required to perform SIMR. The merits of the new method for distinguishing isomers are that it is simple, rapid and economic. To date, methyne addition products ([M+13](+) ions) have been observed for several nitrogenated compounds including aza-crown ethers, aniline and dopamine from SIMR in the ITMS. The xylene isomers are, however, the first three non-nitrogenated compounds that have been shown to produce the methyne addition ions in SIMR.  相似文献   

4.
Orthogonal acceleration time‐of‐flight (oa‐TOF) mass spectrometry (MS) was coupled to gas chromatography (GC) to measure ion yields (ratio of ion counts to number of neutrals entering the ion source) and signal‐to‐noise (S/N) in the electron ionization (EI) mode (hard ionization) as well as in the soft ionization modes of chemical ionization (CI), electron capture negative ion chemical ionization (NICI) and field ionization (FI). Mass accuracies of the EI and FI modes were also investigated. Sixteen structurally diverse volatile organic compounds were chosen for this study. The oa‐TOF mass analyzer is highly suited for FI MS and provided an opportunity to compare the sensitivity of this ionization method to the more conventional ionization methods. Compared to the widely used quadrupole mass filter, the oa‐TOF platform offers significantly greater mass accuracy and therefore the possibility of determining the empirical formula of analytes. The findings of this study showed that, for the instrument used, EI generated the most ions with the exception of compounds able to form negative ions readily. Lower ion yields in the FI mode were generally observed but the chromatograms displayed greater S/N and in many cases gave spectra dominated by a molecular ion. Ion counts in CI are limited by the very small apertures required to maintain sufficiently high pressures in the ionization chamber. Mass accuracy for molecular and fragment ions was attainable at close to manufacturer's specifications, thus providing useful information on molecular ions and neutral losses. The data presented also suggests a potentially useful instrumental combination would result if EI and FI spectra could be collected simultaneously or in alternate scans during GC/MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The mass spectra of tert-butyldimethylsilyl (TBDMS) derivatives of 17 amino acids were obtained using electron ionization (EI) and atmospheric pressure photochemical ionization (APPhCI) mass spectrometry. The APPhCI mass spectra for all of the derivatives except arginine were shown to consist of only molecular [M](+.) and quasimolecular [MH](+) ions whereas, in the case of EI, the compounds in question underwent a drastic fragmentation. The application of APPhCI to gas chromatography-mass spectrometry enables a reliable identification of the TBDMS derivatives of amino acids in a mixture, even if its components are only partially resolved, due to the unique molecular masses for each compound. Comparison of the respective positive-ion chemical ionization (PICI) mass spectra available in the literature with APPhCI spectra has shown that, in the case of PICI, unlike APPhCI, noticeable fragmentation occurs.  相似文献   

6.
Propranolol, deuterium- and 18O-labeled propranolol and related compounds were analyzed using an ion trap mass spectrometer equipped with a modified Finnigan API electrospray interface. Sequential product ion (MSn) experiments were used to elucidate fragmentation pathways for these compounds. The observed ions were compared to those observed under electron impact (EI) conditions. The electrospray ionization (ESI) ion trap spectra, as well as the EI spectra, afford useful information to allow assignments of most product ions, many of which retain portions of the aliphatic three-carbon side chain.  相似文献   

7.
Six synthesized 6-nitroquipazine derivatives were examined by electron ionization (EI) and electrospray ionization (ESI) mass spectrometry in positive and negative ion mode. The compounds exhibit high affinity for the serotonin transporter (SERT) and belong to a new class of SERT inhibitors. The EI mass spectra registered in negative ion mode showed prominent molecular ions for all the compounds studied. All EI mass spectra and all ESI mass spectra showed similar fragmentation pathways of molecular ions, but the pathways differed between EI and ESI. The differences were explained with the aid of theoretical evaluation of the stability of the respective radical ions (EI MS) and protonated ions (ESI MS).  相似文献   

8.
Methane chemical ionization (CI) mass spectra for a series of ten polycyclic chlorinated insecticides and metabolites have been examined. In all cases except heptachlor epoxide the base peak corresponded to elimination of Cl, or OH from the molecule ion. In the spectrum of heptachlor epoxide the [M + H]+ and [M ? Cl]+ clusters were of approximately equal intensity. The CI spectra were remarkably simple, invariably less complex than the corresponding electron-impact (EI) mass spectra and the intensity of the ions with high information content, e.g. [M ? CI]+ was uniformly high. All of these features are important to the analytical potential of these studies. Retro Diels-Alder (RDA) fragments were observed for the chlordanes, aldrin, isodrin, nonachlor and heptachlor epoxide. The reported preliminary data suggest that the relative intensity of RDA ions in CI mass spectra may be useful in establishing molecular configurations.  相似文献   

9.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
  1. Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
  2. Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
  3. Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
  4. Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
These conclusions are demonstrated and supported by experimental data in nine figures and two tables.  相似文献   

10.
Electron ionization (EI) spectra and both positive and negative chemical ionization (CI) spectra have been obtained for four isoquinolinium ylides and two pyridinium ylides. Electron transfer reactions dominate the CI mass specra. The base peak in negative chemical ionization is the [M] ion, formed by electron capture. In the positive methane CI spectra the molecular ion, [M], is relatively more intense than [MH]+ showing electron transfer to be the main positive ionization process. In the positive ammonia CI spectra, proton transfer to give [MH]+ is the main ionization process, but electron transfer is also observed. The EI spectra show fragmentations in which the aromatic nitrogen moiety retains the charge and fragmentation is by loss of radicals or small neutral molecules from the side-chains. Radical driven reactions are proposed to explain these spectra.  相似文献   

11.
A series of isomeric substituted diaryl ethers, i.e., 2- or 4-NO2, 5- FC6H3OC6H4 (4-R), where R=H, COCH3, COOCH3, NO2, CHO, OCH3 etc., which comprise ortho and para isomers with respect to the position of the nitro group are studied under GC-EI-MS and CI-MS conditions. The EI mass spectra of ortho and para isomers show distinct fragment ions, where the [MOH]+ and [MOHO]+ ions specifically appeared in all spectra of the ortho isomers (I), whereas the para isomers (II) contain [MO]+ and [MNO]+ ions. The [MOHCO]+ and [MOHNO]+ ions in I, and [MNO2]+ ion in II are the other specific fragment ions observed but feasibility of these fragment ions are found to depend on the nature of the substituent (R). The substitution (R) effect is also clearly reflected in the formation of fragment ions due to sigma-cleavage process with or without hydrogen migration. Similar differences in the formation of specific fragment ions are also observed in ortho and para isomers of substituted aryl naphthyl ethers. The methane/CI of isomeric compounds resulted in the same set of fragment ions, but prominent differences are observed in the relative abundance of [MHNO]+, which is relatively higher in para isomers compared with corresponding ortho isomer.  相似文献   

12.
Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous to that of liquid CI in ion traps with internal ionization, and is in marked contrast to that of CI with most other standard GC/MS systems that require a change of the ion source.  相似文献   

13.
The ionization pathways were determined for sets of isomeric non-polar hydrocarbons (structural isomers, cis/trans isomers) using ion mobility spectrometry and mass spectrometry with different techniques of atmospheric pressure chemical ionization to assess the influence of structural features on ion formation. Depending on the structural features, different ions were observed using mass spectrometry. Unsaturated hydrocarbons formed mostly [M - 1]+ and [(M - 1)2H]+ ions while mainly [M - 3]+ and [(M - 3)H2O]+ ions were found for saturated cis/trans isomers using photoionization and 63Ni ionization. These ionization methods and corona discharge ionization were used for ion mobility measurements of these compounds. Different ions were detected for compounds with different structural features. 63Ni ionization and photoionization provide comparable ions for every set of isomers. The product ions formed can be clearly attributed to the structures identified. However, differences in relative abundance of product ions were found. Although corona discharge ionization permits the most sensitive detection of non-polar hydrocarbons, the spectra detected are complex and differ from those obtained with 63Ni ionization and photoionization.  相似文献   

14.
Electron impact (EI), fast atom bombardment (FAB) and ammonia chemical ionization [CI(NH3)] mass spectrometry were applied with the aim of differentiating between the anomeric 1alpha- and 1beta-azidopentofuranosyl derivatives. Calculated ammonium affinities [AA(M)] and proton affinities [PA(M)] show that beta-anomers have higher affinities for H+ and NH4+ ions than alpha-azides. Protonated molecules, obtained by CI(NH3) of azidofuranosyl derivatives, lose HN3 giving abundant furanosyl (S+) ions. Ammonia solvation of MH+ ions competes with the previous reaction producing the [SNHN2NH3]+ ion, a competitive product to the ammonium-attached [SN3NH4]+ ion. The fragmentation pathways of the stable and metastable [MNH4]+, MH+ ions, and several other important fragment ions, were determined using mass analyzed ion kinetic energy spectrometry (MIKES). The abundance of the [SN3NH4]+ and/or [SNHN2NH3]+ ions was found to correlate inversely with the exothermicity of ammonia solvation of the MH+ ion. The abundance of the fragment ions [SNHNH3]+, [SNH3]+ and SNH+ in some examples correlates with the exothermicity of the corresponding [MNH4]+ and MH+ parent ion formation. The fragment ions SNH3+ and SNHNH3+ can be formed, at least in part, in the ammonia solvation reaction of the S+ and SNH+ ions taking place within the high-pressure region of the CI ion source.  相似文献   

15.
We have developed a combined EI/FI source for gas chromatography/orthogonal acceleration time‐of‐flight mass spectrometry (GC/oaTOFMS). In general, EI (electron ionization) and FI (field ionization) mass spectra are complementary: the EI mass spectrum contains information about fragment ions, while the FI mass spectrum contains information about molecular ions. Thus, the comparative study of EI and FI mass spectra is useful for GC/MS analyses. Unlike the conventional ion sources for FI and EI measurements, the newly developed source can be used for both measurements without breaking the ion source vacuum or changing the ion source. Therefore, the combined EI/FI source is more preferable than the conventional EI or FI ion source from the viewpoint of the reliability of measurements and facility of operation. Using the combined EI/FI source, the complementarity between EI and FI mass spectra is demonstrated experimentally with n‐hexadecane (100 pg): characteristic fragment ions for the n‐alkane such as m/z 43, 57, 71, and 85 are obtained in the EI mass spectrum, while only the parent peak of m/z 226 (M+) without any fragment ions is observed in the FI mass spectrum. Moreover, the field desorption (FD) measurement is also demonstrated with poly(ethylene glycol)s M600 (10 ng) and M1000 (15 ng). Signals of [M+H]+, [M+Na]+ and [M+K]+ are clearly detected in the FD mass spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Electron ionization (EI), chemical ionization (CI) and fast-atom bombardment (FAB) mass spectra of the marine toxin okadaic acid and its synthetic methyl, pentafluorobenzyl, and trimethylsilyl ester and ether derivatives were generated. Several ionization conditions and ion-processing methods were used to obtain positive- and negative-ion conventional spectra and tandem (MS/MS) spectra. The EI and the positive-ion CI spectra provided fragment ions characteristic of the structure, and the negative-ion CI and FAB spectra provided molecular ions. The addition of alkali salts to the FAB matrix resulted in reduced fragmentation and the formation of intense alkali-metal-cationized molecules. Pentafluorobenzyl ester derivatives provided intense carboxylate ions under electron-capture ionization. Analytically useful MS/MS spectra were obtained by low-energy collision-induced decomposition of the carboxylate anion produced from the tetrasilylated pentafluorobenzylokadaate.  相似文献   

17.
The electron ionization (EI) mass spectral fragmentation of derivatized 4,5- and 5,6-epoxysterols was investigated. Interesting fragmentation processes involving a transannular cleavage of the epoxide ring after transfer of the trimethylsilyl group are significant in the case of 4,5-epoxysterol trimethylsilyl ethers (affording abundant fragment ions at m/z 403 and 404). Different pathways, which have been substantiated by deuterium labelling, are proposed in order to explain the formation of these ions. In contrast, this transfer is not significant in the case of 5,6-epoxysterol trimethylsilyl ethers. The EI mass spectra of these latter compounds appear to be very complex and to differ slightly according to the stereochemistry of the epoxy group. Acetate and trifluoroacetate derivatives of 4,5-epoxysterols display interesting EI mass spectra dominated by a fragment ion at m/z 332 resulting from cleavage of the steroid ring A.  相似文献   

18.
本文报道37个含氟膦.胂羰基的叶立德衍生物的电子轰击(EI)和8个含氟胂羟基叶立德的甲烷化学电离(Cl)正.负离子质谱. 研究其断裂规律,氧和氟原子重排以及不同取代基对一些特征离子强度的影响.  相似文献   

19.
Positive fast ion bombardment, positive chemical ionization (CI+) and positive electron impact (EI) ionization mass spectrometry were used to investigate a number of relatively large and structurally related organic molecules. Some of the major dissociation pathways observed in the CH4-CI+ mass spectra are not present under NH3-CI+ conditions, but are obtained in the collision-induced dissociation (CID) spectrum of the 50 eV MH+ molecular ion, formed in the latter reaction. The resemblance between the EI mass spectra and their fast ion bombardment counterparts, the effect of changing the energy of the bombarding Cs+ ion beam over the range 2–16 keV and the different degrees of internal excitation of ions formed in different CI reagent gases are discussed.  相似文献   

20.
Two unusual disinfection by-products have been detected periodically in the gas chromatography/mass spectrometry (GC/MS) characterization analyses of semi-volatile organics in treated drinking water. The electron ionization (EI) mass spectra contained mono-chlorinated and mono-brominated ions at m/z 107/109 and 151/153, respectively. Library searching techniques suggested mono-halogenated butanol structures but no matches could be found. Positive ion chemical ionization (CI) spectra contained mono-chlorinated and mono-brominated ions at m/z 105/107 and 149/151, respectively. No [M + H]+ ions were initially observed. Accurate mass measurements confirmed the empirical formulae for the significant ions in the EI spectra and the mono-halogenated butanol structures. Further CI experiments with other reagent gases and instruments revealed possible molecular weights of 139 and 183 Da, respectively. Tandem mass spectrometry (MS/MS) experiments in EI and CI were used to elucidate the fragmentation schemes. The two compounds have been tentatively identified as 1-aminoxy-1-chlorobutan-2-ol and 1-aminoxy-1-bromobutan-2-ol, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号