首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

2.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

3.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

4.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

5.
Zusammenfassung Die Bestimmung von 800 bis 30g Pb(II) durch potentiometrische Titration mit Molybdat unter Verwendung einer bleispezifischen Elektrode wurde untersucht. Unter geeigneten Bedingungen sind mit 4·10–3 M Molybdat 800 bis 300g Pb(II) in wäßriger Lösung mit einer Genauigkeit von ±0,57% bzw. 0,45% und einer Reproduzierbarkeit von ±0,43% bzw. ±0,30% (Standardabweichung=0,25% bzw. 0,17%) je nach Titrationsart automatisch bzw. manuell bestimmbar.Zur Bestimmung von Pb(II)-Mengen <300g ist eine 2·10–3 M Molybdatlösung zu verwenden. 300 bis 100g Pb(II) sind in wäßriger Lösung mit zufriedenstellenden Resultaten bestimmbar, jedoch verbessert eine Titration in 40% igem Ethanol nicht nur die Genauigkeit in diesem Bereich, sondern erlaubt auch noch 30g Pb(II) mit einer Genauigkeit von ±1% und einer Reproduzierbarkeit von ±2% (Standardabweichung aus 20 Titrationen von 100g Pb(II)= 0,60%) zu bestimmen.Die Titration von 300–800g Pb(II) in wäßriger Lösung und von 30–300g Pb(II) in 40% igem Ethanol läßt sich auch in 0,1M NaNO3– 0,1M NaClO4– Lösung durchführen und ermöglicht somit auch zuverlässige Bleibestimmungen in organischen Verbindungen nach Mineralisierung mit HNO3–HClO4–H2O2.
The determination of 800 to 30 g lead(II) by potentiometric titration with molybdate
Summary The determination of 800 to 30g Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300g Pb(II) in aqueous solution by automatic or manual titration with 4·10–3 M molybdate can be determined with an accuracy of ±0.57% and ±0.45% and a precision of ±0.43% and 0.30% (standard deviation=0.25% and 0.17%, resp.).For determining amounts of Pb(II) below 300g, a 2·10–3 M molybdate solution has to be used. Although 300 to 100g Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30g Pb(II) can be determined with an accuracy of ±1% and a precision of ±2% (standard deviation from 20 titrations of 100g Pb(II)=0.60%).The titration of 300–800g Pb(II) in water and of 30–300g Pb(II) in 40% ethanol is also possible in 0.1M NaNO3– and 0.1M NaClO1– medium and can be used in the lead determination in organic compounds after mineralization with HNO3-HClO4-H2O2.
  相似文献   

6.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

7.
5,10,15,20-tetrakis(3-chloro-4-sulfophenyl)porphine (m-Cl-TPPS4) was synthesized and used for the Spectrophotometric determination of mercury by flow injection analysis. A pseudo-first-order reaction kinetic mechanism was proposed with a rate constant of 0.8 min–1 for Hg(II) withm-Cl-TPPS4 in the presence of 8-hydroxyquinoline in a medium of 1.0M acetic acid and sodium acetate buffer solution (pH 6.22). In the optimum conditions of reaction temperature (85 ° C), stopped-flow time (60 s) and sampling volume (100 l), the method's relative standard deviation was 0.82% (n = 12) at 5.0 g ml–1 mercury, with a linear range of 0–12.0 g ml–1 and an analytical frequency of 60h–1. The detection limit (3) was 0.025 g ml–1. Interference studies showed that most metal ions co-existing with Hg2+ could be tolerated at 100-fold excess levels, but Zn2+, Cu2+ and Mn2+ needed to be masked. The method has been applied to the analysis of water samples with satisfactory results.  相似文献   

8.
In a long-term field study at two locations with different air pollution levels several soot-selective measurement techniques were compared with a thermochemical method which measures non-extractable carbon (NEC) detecting the evolved CO2 by means of coulometric titration. The attenuation measurement technique (aethalometer) and the aerosol photoemission method showed good correlations to NEC for concentrations ranging from 1.6g/m3 to 40.8g/m3. The specific mass absorption coefficient of black carbon with respect to NEC varied between 8.4m2/g and 13.7m2/g with respect to the measurement sites, but the value was found to remain constant at each site independent of seasonal or meteorological variations. The ratio of photoelectric signal to NEC varied between 16 fA·(g/m3)–1 and 33 fA·(g/m3)–1 depending on the age of the aerosol. The diurnal variations of that ratio showed strong similarities to the traffic patterns. Additionally a slight temperature dependence of this ratio was found for the aged aerosol with a proportionality factor of – 0.35 fA·(K·g/m3)–1. With the reflectance measurement technique (smoke shade method) reliable NEC determination was not possible for NEC concentrations 5 g/m3.  相似文献   

9.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

10.
Summary The reducing fusion gas extraction method has been used for the determination of nitrogen in uranium metal and uranium dioxide reference materials at levels of about 10–15g·g–1. It has been found that when extracting at temperatures above 2700° C the use of a platinum flux is no longer necessary. Pure nitrogen and nitrogen-helium mixtures were used for calibrating the detection unit in the range of 1.5–670 g. The calibration of the extraction was performed with metallic reference materials in the range of 8–331 g N2 content.
Bestimmung von Stickstoff in Uran und Uranoxid durch Hochtemperatur-Gasextraktion
Zusammenfassung Die Gasextraktion aus reduzierender Schmelze wurde zur Stickstoffbestimmung in Uranmetall- und Urandioxid-Referenzmaterialien bei Gehalten von 10–15 g·g–1 angewendet. Bei Temperaturen über 2700° C ist kein Platinbad mehr erforderlich. Zur Eichung der Detektionseinheit im Bereich von 1,5–670 g wurden reiner Stickstoff oder Stickstoff-Helium-Mischungen benutzt. Zur Eichung der Extraktion wurden metallische Referenzmaterialien mit (8–331g) N2 eingesetzt.
  相似文献   

11.
A high-performance thin layer chromatographic method coupled with densitometric analysis has been developed for measurement of benazepril and cilazapril, both pure and in their commercial dosage forms. The active substances were extracted from tablets with methanol (mean recovery 102%) and chromatographed on silica gel 60 F254 HPTLC plates in horizontal chambers with ethyl acetate–acetone–acetic acid–water, 8:2:0.5:0.5 (v/v), as mobile phase. Chromatographic separation of these ACE inhibitors was followed by UV densitometric quantitation at 215 nm. Calibration plots were constructed in the range 0.4 to 2.0 g L–1 for benazepril (2.0–10.0 g spot–1) and from 0.5 to 1.5 g L–1 for cilazapril (4.0–12.0 g spot–1) with good correlation coefficients (r 0.990). The method was used to determine benazepril and cilazapril in pharmaceutical preparations with satisfactory precision (1.4% < RSD < 5.6%) and accuracy (1.7 < RE < 5.1).  相似文献   

12.
Various mushroom species have been analyzed for their elemental composition (i.e., Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, P, Sr and Zn) by means of ICP-AES. The accuracy of the measurements was confirmed by analyzing a series of the same samples by short time activation analysis. The data were evaluated statistically including the values of137Cs. The results denote that the distribution of these elements and their correlation of these elements and their correlation coefficients are highly distinctive for each mushroom species. K, Na and P were found to correlate negatively with137Cs in most species. Suillus grevillei and Cantharellus cibarius show high Be values (0.27 and 0.30 g g–1, respectively), while Pb was high in Suillus grevillei (16.3 g g–1) and Amanita rubescens (9.3 g g–1). Higher levels of Cd were found in Rozites caperata and Russula vesca with a mean of 9.2 and 16.1 g g–1, respectively. Cluster analysis was applied to classify these samples according to their botanical species using their elemental composition. The concentrations of Al, Cr, Mn, Na and137Cs have no influence on the classification of these samples.  相似文献   

13.
    
Summary Optimum for the generation of arsine from As(III) and (V) in a generating system without carrier gas and with atomization in an air-acetylene flame were established. A 3% solution of NaBH4 was used as reducer. The effect of 26 different species on the determination of arsenic was studied. The method has been applied to determine arsenic in copper.A linear relationship exists between 0.5 and 3 g for As(III) and between 1 and 4 total g of As(V). The sensitivity, expressed as the slope of the calibration curve is 0.067 g–1 for As(III) and 0.054 g–1 for As(V); the characteristic masses are 1.22 g and 0.44 g, and the limits of detection 0.27 g and 0.33 g, respectively.
Direkte Flammen-AAS — Erzeugung flüchtiger kovalenter HydrideStörungen durch das Verhältnis der As(III/V)-Valenzstufen und Arsenbestimmung in Kupfer
Zusammenfassung Optimale Bedingungen wurden ausgearbeitet für die Arsinerzeugung aus As(III) und As(V) in einem System ohne Trägergas mit Atomisierung in einer Luft-Acetylen-Flamme. Zur Reduktion dient eine 3%ige NaBH4-Lösung. Der Einfluß von 26 Fremdionen wurde geprüft und das Verfahren zur Arsenbestimmung in Kupfer angewendet. Eine lineare Beziehung ergab sich für 0,5–3 g As(III) und 1–4 g As(V). Die Empfindlichkeit (als Neigung der Eichkurve) beträgt 0,067 g–1 für As(III) und 0,054 g–1 für As(V). Die charakteristischen Massen sind 1,22 g bzw. 0,44 g und die Nachweisgrenzen 0,27 g bzw. 0,33 g.


This work has been sponsored by the CAICYT (project 3378/83) of the Spanish Education and Science Department.  相似文献   

14.
Summary Five isomers present in technical benzene hexachloride were successfully separated by TLC on silica-gel G impregnated with silver nitrate solution. The -isomer was identified by running a control sample of -BHC. Measurement of the spot area was found suitable for the estimation of 5–20g of-BHC, and was applied to analysis of autopsy tissues. The limit of identification is 0.1g.
Zusammenfassung Auf mit Silbernitratlösung imprägniertem Kieselgel G konnten dünn-schichtchromatographisch fünf Isomere aus technischem Hexachlorbenzol erfolgreich getrennt werden. Das-Isomere wurde mit Hilfe einer Vergleichsprobe identifiziert. Die Planimetrie der Flecken eignet sich zur Schätzung von 5–20 g-Hexachlorbenzol. Die Methode wurde zur Untersuchung von Autopsieproben angewendet. Die Nachweisgrenze beträgt 0,1g.
  相似文献   

15.
The intake and tissue distribution of thorium (2 3 2Th) was studied in an urban (Bombay) population in India. From the analysis of 16 whole diet samples, the average daily intake through food was found to be 2 g (range 0.8–4.3 g·d–1). The estimated intake through drinking water and inhalation comes out to be 0.03 and 0.02 g per day. From the analysis of human autopsy tissue samples it is observed that the concentration ranges in lungs and bone are 1.5–16 g/kg and 0.2–9.0 g/kg fresh weight respectively. The average urinary concentration is 12 ng/1 (range 7–22 ng/l for 10 samples). Among the different body tissues, pulmonary lymph nodes were found to contain the highest concentration (geometric mean 53.4 g/kg, range 31.4–85.5 g/kg for 6 samples). Analysis of the samples was done by the neutron activation technique. 311.8 keV gamma photons of2 3 3Pa which is the activation product of2 3 2Th, were counted after chemical separation. A 54 cm3 intrinsic Ge detector coupled to 1024-channel analyser was used. Using the average lung content and the daily average intake values of thorium through inhalation, the clearance half-time from lung was estimated.  相似文献   

16.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

17.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

18.
Using the 871-keV16O p/1,0/ prompt -ray, oxygen was determined with a relative precision of ±3.8% at a concentration level of 120 g g–1. The sensitivity of the method is below 10 g g–1. 50 nm oxide layers on silicon wafers can be determined with a relative precision of 10%. A chamber for transporting targets sensitive to atmospheric gases and humidity is described.  相似文献   

19.
A generalized regression artificial neural network (GRANN) was developed and evaluated for modeling cadmiums nonlinear calibration curve in order to extend its upper concentration limit from 4.0 g L–1 up to 22.0 g L–1. This type of neural network presents important advantages over the more popular backpropagation counterpart which are worth exploiting in analytical applications, namely, (1) a smaller number of variables have to be optimized, with the subsequent reduction in development hassle; and, (2) shorter development times, thanks to the fact that the adjustment of the weights (the artificial synapses) is a non-iterative, one-pass process. A backpropagation artificial neural network (BPANN), a second-order polynomial, and some less frequently employed polynomial and exponential functions (e.g., Gaussian, Lorentzian, and Boltzmann), were also evaluated for comparison purposes. The quality of the fit of the various models, assessed by calculating the root mean square of the percentage deviations, was as follows: GRANN > Boltzmann > second-order polynomial > BPANN > Gauss > Lorentz. The accuracy and precision of the models were further estimated through the determination of cadmium in the certified reference material Trace Metals in Drinking Water (High Purity Standards, Lot No. 490915), which has a cadmium certified concentration (12.00±0.06 g L–1) that lies in the nonlinear regime of the calibration curve. Only the models generated by the GRANN and BPANN accurately predicted the concentrations of a series of solutions, prepared by serial dilution of the CRM, with cadmium concentrations below and above the maximum linear calibration limit (4.0 g L–1). Extension of the working range by using the proposed methodology represents an attractive alternative from the analytical point of view, since it results in less specimen manipulation and consequently reduced contamination risks without compromising either the accuracy or the precision of the analyses. The implementation of artificial neural networks also helps to reduce the trial-and-error task of looking for the right mathematical model from among the many possibilities currently available in the various scientific and statistic software packages.  相似文献   

20.
A red, water-soluble complex of nickel with PAR can be extracted into chloroform with CTAB at pH 7.0. The system obeys Beer's law upto 0.5 g/ml with a molar absorptivity of 45 200 L·mol–1·cm–1 at 540 nm. Job's method of continuous variations revealed that the composition of the extracting species is 1:2:2 for nickel:PAR:CTAB. Based on this extraction, a highly sensitive and selective spectrophotometric method for the determination of nickel in polymetallic sea-bed nodules and in steels, after prior separation of iron and manganese, was developed. The standard deviation was 0.04–0.127 g for 5–25 g of nickel.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号