首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Morphine was used as a model analyte to examine the possibility of using cellulose, physically modified by papermaking and converting techniques, as a capillary matrix in a lateral flow type of diagnostic assay. This research was directed toward low-cost, disposable, and portable paper-based diagnostics, with the aim of addressing the analytical performance of paper as a substrate in the analysis for drugs of abuse. Antibody Fab fragments were used as sensing molecules, and gold nanoparticle detection was employed. Inkjet printing was used to pattern sensing biomolecules as detection zones on paper. To validate the usefulness of paper as a diagnostic platform, the principle of a direct sandwich assay, based on immunocomplex formation between morphine and the anti-morphine Fab fragment and detection of the formed immunocomplex by another Fab fragment, was implemented. Results were compared with that achieved by using nitrocellulose as a reference material. Possible interfering from the sample matrix on assay quality was investigated with spiked oral fluid samples. Under optimized conditions, a visually assessed limit of detection for the sandwich assay was 1 ng/mL, indicating that the paper-based test devices developed in this work can perform screening for drugs of abuse and can fulfill the requirement for a sensitive assay in diagnostically relevant ranges. Fig
?  相似文献   

2.
We report a new chemiluminescence resonance energy transfer (CRET) technique, using gold nanoparticles (AuNPs) as efficient energy acceptor, for homogeneous measurement of cell apoptosis enzyme with high sensitivity. In the design of the CRET system, we chose the highly sensitive chemiluminescence (CL) reaction between luminol and hydrogen peroxide catalysed by horseradish peroxidase (HRP) because the CL spectrum of luminol (λ max 425 nm) partially overlaps the visible absorption bands of AuNPs. In this system, the peptide substrate (DEVD) of caspase 3 was linked to the AuNP surface by Au–S linkage. HRP was attached to the AuNP surface by means of a bridge formed by the streptavidin–biotin reaction. CRET occurred as a result of formation of AuNP–peptide–biotin–streptavidin–HRP complexes. The CL of luminol was significantly reduced, because of the quenching effect of AuNPs. The quenched CL was recovered after cleavage of DEVD by caspase 3, an enzyme involved in the apoptotic process. Experimental conditions were systematically investigated. Under the optimum conditions the increase of the CL signal was linearly dependent on caspase 3 concentration within the concentration range 25 pmol L?1 to 800 pmol L?1 and the detection limit of caspase 3 was as low as 20 pmol L?1, one order of magnitude lower than for FRET sensors based on graphene oxides. Our method was successfully used to detect drug-induced apoptosis of cells. This approach is expected to be extended to other assays, i.e., using other enzymes, analytes, CL substances, and even other nanoparticles (e.g., quantum dots and graphene). Fig. a
?  相似文献   

3.
Graphene is a two-dimensional carbon nanomaterial one atom thick. Interactions between graphene oxide (GO) and ssDNA containing different numbers of bases have been proved to be remarkably different. In this paper we propose a novel approach for turn-on fluorescence sensing determination of glucose. Hydrogen peroxide (H2O2) is produced by glucose oxidase-catalysed oxidation of glucose. In the presence of ferrous iron (Fe2+) the hydroxyl radical (?OH) is generated from H2O2 by the Fenton reaction. This attacks FAM-labelled long ssDNA causing irreversible cleavage, as a result of the oxidative effect of ?OH, producing an FAM-linked DNA fragment. Because of the weak interaction between GO and short FAM-linked DNA fragments, restoration of DNA fluorescence can be achieved by addition of glucose. Due to the excellent fluorescence quenching efficiency of GO and the specific catalysis of glucose oxidase, the sensitivity and selectivity of this method for GO-DNA sensing are extremely high. The linear range is from 0.5 to 10 μmol L?1 and the detection limit for glucose is 0.1 μmol L?1. The method has been successfully used for analysis of glucose in human serum. Figure
?  相似文献   

4.
We report on a simple and sensitive water-soluble fluorescent conjugated polymer for use in a choline biosensor. Choline is oxidized by the enzyme choline oxidase (ChOx), and the hydrogen peroxide (H2O2) formed is used to oxidize catechol via catalysis by horseradish peroxidase. The product of oxidation acts as a quencher of the photoluminescence of a fluorescent conjugated polymer. The ratio of the fluorescence intensity of the system in the presence and absence of the choline, respectively, serves as the analytical information. It is proportional to the concentration of choline in the 0.1 μM to 20 μM concentration range. The detection limit for choline is 50 nM. The biosensor was successfully applied to the determination of choline in milk samples with satisfactory reproducibility and accuracy. This is the first biosensor where a ChOx/HRP enzyme-coupled assay is used in combination with a water-soluble conjugated polymer for the fluorescent detection of choline. In our opinion, it provides a common platform for further development of enzymatic biosensors based on fluorescent conjugated polymers.
Figure
We have constructed a sensitive optical choline sensor based on a fluorescent conjugated polymer and an enzyme-coupled assay. Choline is oxidized by the enzyme choline oxidase, and the H2O2 formed is used to oxidize catechol via catalysis by horseradish peroxidase. The product of oxidation acts as a quencher of the photoluminescence of a fluorescent conjugated polymer.  相似文献   

5.
A novel CuS–graphene (CuS-Gr) composite was synthesized to achieve excellent electrochemical properties for application as a DNA electrochemical biosensor. CuS-Gr composite was prepared by a hydrothermal method, in which two-dimensional graphene served as a two-dimensional conductive skeleton to support CuS nanoparticles. A sensitive electrochemical DNA biosensor was fabricated by immobilizing single-stranded DNA (ss-DNA) labeled at the 5′ end using 6-mercapto-1-hexane (HS-ssDNA) on the surface of Au nanoparticles (AuNPs) to form ssDNA-S–AuNPs/CuS-Gr, and hybridization sensing was done in phosphate buffer. Cyclic voltammetry and electrochemical impedance spectroscopy were performed for the characterization of the modified electrodes. Differential pulse voltammetry was applied to monitor the DNA hybridization using an [Fe(CN)6]3?/4? solution as a probe. Under optimum conditions, the biosensor developed exhibited a good linear relationship between the current and the logarithm of the target DNA concentration ranging from 0.001 to 1 nM, with a low detection limit of 0.1 pM (3σ/S). The biosensor exhibited high selectivity to differentiate one-base-mismatched DNA and three-base-mismatched DNA. The results indicated that the sensing platform based on CuS-Gr provides a stable and conductive interface for electrochemical detection of DNA hybridization, and could easily be extended to the detection of other nucleic acids. Graphical abstracts
?  相似文献   

6.
Thermal models of ultraviolet MALDI ionization based on the polar fluid concept are re-examined. Key components are very high solvating power of the fluidized matrix and consequent low reaction-free energy, attainment of thermal equilibrium in the fluid, and negligible recombination losses. None of these are found to hold in a MALDI event. The reaction-free energy in the hot matrix must be near the gas phase value, ion formation is too slow to approach equilibrium, and geminate recombination of autoprotolysis pairs greatly increases the initial loss rate. The maximum thermal ion yield is estimated to be many orders of magnitude below experimental values. Figure
?  相似文献   

7.
We have developed a crown ether based selective colorimetric sensing scheme for the determination of Pb(II) ion by using gold nanoparticles modified with dithiocarbamate derivative of 4′-aminobenzo-18-crown-6 that acts as a colorimetric probe. Monodisperse Au-NPs were prepared by reacting 4′-aminobenzo-18-crown-6 with carbon disulfide to generate the dithiocarbamate ligand which was then added to the Au-NPs to form a supramolecular assembly on their surface. The Au-NPs modified in this way undergo aggregation in the presence of Pb(II) ions, and this causes the color to change from red to blue. The Pb(II)-induced aggregation can be monitored by using UV-visible spectrometry and even with the bare eye. The absorbance ratio (A650nm/A520nm) is linearly related to the concentration of Pb(II) in the 0.1 to 75 μM range (with a correlation coefficient of 0.9957), and the detection limit is 50 nM which is lower than the allowable level (75 nM) as defined by the US EPA. The method was successfully applied to the determination of Pb(II) in spiked water samples. Figure
Schematic representation of Pb2+ ion-induced DTC-CE-Au NPs aggregation via sandwich complex formation.  相似文献   

8.
We describe a hybrid MALDI/C60-SIMS Q-TOF mass spectrometer and corresponding sample preparation protocols to image intact biomolecules and their fragments in mammalian spinal cord, individual invertebrate neurons, and cultured neuronal networks. A lateral spatial resolution of 10 μm was demonstrated, with further improvement feasible to 1 μm, sufficient to resolve cell outgrowth and interconnections in neuronal networks. The high mass resolution (>13,000 FWHM) and tandem mass spectrometry capability of this hybrid instrument enabled the confident identification of cellular metabolites. Sublimation of a suitable matrix, 2,5-dihydroxybenzoic acid, significantly enhanced the ion signal intensity for intact glycerophospholipid ions from mammalian nervous tissue, facilitating the acquisition of high-quality ion images for low-abundance biomolecules. These results illustrate that the combination of C60-SIMS and MALDI mass spectrometry offers particular benefits for studies that require the imaging of intact biomolecules with high spatial and mass resolution, such as investigations of single cells, subcellular organelles, and communities of cells. Graphical Abstract
?  相似文献   

9.
The distribution of free and bound forms of B-group vitamins (B1, B2, B3, B5, and B6) was quantified in quinoa seeds using LC-MS-TOF combined with a stable isotope dilution assay. The effectiveness of liberating thiamine, riboflavin, nicotinic acid, pantothenic acid, pyridoxal, and pyridoxine from the food matrix and cofactors was evaluated for a variety of extraction conditions, including the addition of enzymes. Phosphatase and protease inhibitors, as well as ultrafiltration, were evaluated for their ability to suppress vitamer liberation via enzymes endogenous to quinoa. Cold extraction, together with a mixture of phosphatase and protease inhibitors, is identified as the most efficient treatment to prevent the conversion of cofactors into simple vitamers. Overnight incubation at 37 °C both with and without additional hydrolytic enzyme preparations containing phosphatase and β-glucosidase activity was almost equally effective in releasing the bound forms of the vitamers. This indicates that the endogenous enzymes within quinoa seeds have high activity. β-Glucosidase should be used when the total pyridoxine content is to be determined, and thermal treatment followed by enzymatic treatment with phosphatase activity is recommended to liberate the bound forms of pyridoxal prior to quantification. Graphical Abstract
Free and bound forms of B-group vitamins in quinoa  相似文献   

10.
An electrochemical glucose biosensor was developed by immobilizing glucose oxidase (GOx) on a glass carbon electrode that was modified with molybdenum disulfide (MoS2) nanosheets that were decorated with gold nanoparticles (AuNPs). The electrochemical performance of the modified electrode was investigated by cyclic voltammetry, and it is found that use of the AuNPs-decorated MoS2 nanocomposite accelerates the electron transfer from electrode to the immobilized enzyme. This enables the direct electrochemistry of GOx without any electron mediator. The synergistic effect the MoS2 nanosheets and the AuNPs result in excellent electrocatalytic activity. Glucose can be detected in the concentration range from 10 to 300 μM, and down to levels as low as 2.8 μM. The biosensor also displays good reproducibility and long-term stability, suggesting that it represents a promising tool for biological assays. Figure
A MoS2-based glucose sensor has been prepared by gold nanoparticles-decorated MoS2 nanocomposite, which exhibited excellent electrocatalytic activity, reproducibility and long-term stability. It was applied to determine glucose concentration in human serum, suggest the sensor maybe promising for practical application.  相似文献   

11.
Electrochemical analytical methods have the advantages of simplicity, direct measurements, and ease of miniaturization which pave the way for real time detection and sensing. However, the complexity of living systems usually requires electrochemical sensors to display high selectivity, sensitivity, accuracy, biocompatibility and stability over time. Nanomaterials possess attractive properties in terms of surface modification, catalysis, and functionality. These open new avenues with respect to electrochemical enzymatic determination of neurochemicals such as dopamine, serotonin and ascorbate, biological small molecules such as H2O2 and metal ions such as copper(II) in-vivo. Three properties of nanomaterials make their use particularly attractive, namely the larger surface-to-volume ratio area, their unique surface, and the ease of electron transfer between enzymes and electrodes. These properties make them more sensitive, selective and stable. The article is subdivided into sections that cover applications of the following materials: carbonaceous materials (mainly carbon nanotube), noble metal particles (mainly gold and platinum particles), and semiconductor (mainly metal oxide) nanomaterials. A conclusion and outlook section addresses current chances and limitations. The review contains 99 references. Figure
Three attractive properties of nanomaterials: the larger surface-to-volume ratio area, unique surface, and facilitating the electron transfer between enzyme and electrode, can improve the analytical performance of electrode, fulfilling the requirements in sensitivity, selectivity and stability for in vivo electrochemistry.  相似文献   

12.
Janus materials with anisotropic chemical structures and physical properties have attracted increasing attention due to their diversified potential applications. In this paper, titanium dioxide/3-(trimethoxysilyl) propylmethacrylate (TiO2/MPS) was obtained by swelling assisted with extrusion of PS@TiO2. Then, the phenolic resin (PF) was coated on the surface of MPS lobe. Finally, TiO2/C Janus composite particles were obtained by sintering at the atmosphere of nitrogen. The middle objects during reactive process and the final product were systematically characterized. Results showed that the Janus porous particles of TiO2/C were snowman-like structure, in which the average diameter of the carbon lobe was 178 nm and that of TiO2 lobe was 226 nm. When used as photocatalysts for Rhodamine B degradation in aqueous solution under UV irradiation, the resulted Janus product exhibited more efficient photocatalytic activity than TiO2 hollow microspheres. Graphical abstract
Schematic illustration of swelling polymerization approach to synthesize TiO2/C Janus composite particles and its photocatalytic activity for the degradation of rhodamine B  相似文献   

13.
We describe a novel procedure for the synthesis of nitrogen-doped reduced graphene oxide (N-rGO). It is based on the thermal reduction of GO (dispersed in water) with sodium diethyldithiocarbamate that acts as both the reducing agent and the source for nitrogen. The surface morphology of the N-rGO is characterized using high resolution transmission electron microscopy. X-ray photoelectron spectroscopy was carried out to study the composition of their surface, and Raman spectroscopy was performed to study the level of doping with nitrogen and the structural order. The N-rGO was deposited on a glassy carbon electrode (GCE), and the resulting electrode utilized as a sensing platform for 4-nitrophenol (4-NP). The modified GCE exhibits a well-defined oxidation peak current that is about ten times larger when compared to that of a bare GCE. The electron transfer number, proton transfer number and electron transfer rate constant (ks 1.046 s?1) were determined. At optimized conditions, the oxidation peak current is linearly related to the concentration of 4-NP in the 20–500 nM range, with a correlation coefficient of 0.9917. The detection limit (at an SNR of 3) is 7 nM. The method was successfully applied to the analysis of waters spiked with 4-NP. Recoveries range from 97.8 to 102.6 %, and no interferences are found for common inorganic cations and anions. Figure
?  相似文献   

14.
The evaluation of a fully automated quantitative proton nuclear magnetic resonance spectroscopy (qNMR) processing program, including the determination of its processing uncertainty, and the calculations of the combined uncertainty of the qNMR result, is presented with details on the use of a trimmed purity average. Quantitative NMR spectra (1359) were collected over a 4-month period on various concentrations of pseudoephedrine HCl dissolved in D2O (0.0610 to 93.60 mg/mL) containing maleic acid (the internal standard) to yield signal-to-noise ratios ranging from 3 to 72,000 for analyte integral regions. The resulting 5436 purities exhibited a normal distribution about the best estimate of the true value. The median absolute deviation (MAD) statistical method was used to obtain a model of uncertainty relative to the signal-to-noise of the analyte’s integral peaks. The model was then tested using different concentrations of known purity chloroquine diphosphate. qNMR results of numerous illicit heroin HCl samples were compared to those obtained by capillary electrophoresis. Graphical Abstract
?  相似文献   

15.
A new method for measuring the ion velocity distribution using an internal matrix-assisted laser desorption/ionization (MALDI) source Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometer is described. The method provides the possibility of studying ion velocities without any influence of electric fields in the direction of the instrument axis until the ions reach the ICR cell. It also allows to simultaneously account for and to estimate not only the velocity distribution but the angular distribution as well. The method was demonstrated using several types of compounds in laser desorption/ionization (LDI) mode. Graphical Abstract
?  相似文献   

16.
An ion imprinted polymer coated onto magnetite (Fe3O4) nanoparticles is shown to be a useful magnetic sorbent for the fairly selective preconcentration of vanadium. The sorbent was prepared by radical copolymerization of 3-(triethoxysilyl)propyl methacrylate (the monomer), ethylene glycol dimethacrylate (the cross-linker), and the vanadium(IV) complex of 1-(2-pyridylazo-2-naphthol) in the presence of magnetite nanoparticles. The material was characterized by IR spectroscopy, scanning electron microscopy, and thermal analysis. The vanadium(IV) ions were removed from the imprint by a solution containing thiourea and HCl, and the eluent was submitted to AAS. The analytical efficiency and relative standard deviation are 99.4 and ±2.3 %, respectively, under optimum conditions, and the limit of detection is 20 ng mL?1. The method was successfully applied to the preconcentration and determination of vanadium(IV) ions in crude oil. Figure
An ion imprinted polymer is coated on to magnetite nanoparticles as a useful magnetic sorbent for the fairly selective preconcentration of vanadium which can be used for vanadium determination in crude oil.  相似文献   

17.
The internal energy distributions for dried and liquid samples that were vaporized with femtosecond duration laser pulses centered at 800 nm and postionized by electrospray ionization-mass spectrometry (LEMS) were measured and compared with conventional electrospray ionization mass spectrometry (ESI-MS). The internal energies of the mass spectral techniques were determined by plotting the ratio of the intact parent molecular features to all integrated ion intensities of the fragments as a function of collisional energy using benzylpyridinium salts and peptides. Measurements of dried p-substituted benzylpyridinium salts using LEMS resulted in a greater extent of fragmentation in addition to the benzyl cation. The mean relative internal energies, int> were determined to be 1.62?±?0.06, 2.0?±?0.5, and 1.6?±?0.3 eV for ESI-MS, dried LEMS, and liquid LEMS studies, respectively. Two-photon resonances with the laser pulses likely caused lower survival yields in LEMS analyses of dried samples but not liquid samples. In studies with larger biomolecules, LEMS analyses of dried samples from glass showed a decrease in survival yield compared with conventional ESI-MS for leucine enkephalin and bradykinin of ~15% and 11%, respectively. The survival yields for liquid LEMS analyses were comparable to or better than ESI-MS for benzylpyridinium salts and large biomolecules. Figure
?  相似文献   

18.
We report on an electrochemiluminescent (ECL) sensing technique for the detection of the hybridization between oligonucleotides. A glassy carbon electrode was first functionalized with a composite prepared from gold nanoparticles and carbon nanotubes, and a sensor was then constructed by immobilizing the probing oligonucleotide. The ECL of luminol acts as the sensing signal. It is quenched, to a different degree, by the hybridized double strands of the oligonucleotide depending on the match status. The slope of the ECL response as a function of the status of hybridization drops with increasingly matched hybridization. The response is attributed to the interaction between luminol and the strands of oligomers, and also related to the reduction of reactive oxygen species.
Figure
An electrochemiluminescent sensing technique is developed by immobilization of probing oligonucleotide on a previously functionalized electrode with composite of carbon nanotubes and gold nano-particles. The quenching efficiency for ECL of luminol upon the hybridized status of target oligonucleotide with probing one had been detected where the mismatch ratio was distinguishable. ECL response for luminol on (a) CNTs/AuNP/GCE, (b) probe-strand/CNTs /AuNP/GCE, (c) 1-3 hybridized strands/CNTs/AuNP/GCE and (d) 1-2 hybridized strands/CNTs/AuNP/GCE.  相似文献   

19.
We are presenting magnetic molecularly imprinted polymer nanoparticles (m-MIPs) for solid-phase extraction and sample clean-up of paracetamol. The m-MIPs were prepared from magnetite (Fe3O4) as the magnetic component, paracetamol as the template, methacrylic acid as a functional monomer, and 2-(methacrylamido) ethyl methacrylate as a cross-linker. The m-MIPs were then characterized by transmission electron microscopy, FT-IR spectroscopy, X-ray diffraction and vibrating sample magnetometry. The m-MIPs were applied to the extraction of paracetamol from human blood plasma samples. Following its elution from the column loaded with the m-MIPs with an acetonitrile-buffer (9:1) mixture, it was submitted to HPLC analysis. Paracetamol can be quantified by this method in the 1 μg L?1 to 300 μg L?1 concentration range. The limit of detection and limit of quantification in plasma samples are 0.17 and 0.4 μg L?1. The preconcentration factor of the m-MIPs is 40. The HPLC method shows good precision (4.5 % at 50 μg L?1 levels) and recoveries (between 83 and 91 %) from spiked plasma samples. Figure
We are presenting magnetic molecularly imprinted polymer nanoparticles (m-MIPs) for solid-phase extraction and sample clean-up of paracetamol. The m-MIPs were applied to the extraction of paracetamol from human blood plasma samples  相似文献   

20.
Quantitation of cytochrome c (Cyt c) in cell lysates through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using gold nanoparticles (Au NPs) as the matrix and GR-10 peptide as an internal standard has been demonstrated. To shorten digestion time, temperature sensitive microgels containing trypsin (TR) and Au NPs have been employed. As-prepared functional microgels (TR/Au NPs/MGs) allow digestion of Cyt c within 15 s under microwave irradiation. The internal standard SALDI-MS approach provides linearity (R2 = 0.98) of MS signal ratio (I 1168.6/I 1067.6) of the tryptic digested peptide (m/z 1168.6) to GR-10 peptide (m/z 1067.6) against the concentration of Cyt c ranging from 25 to 200 nM, with a limit of detection (at a signal-to-noise ratio of 3) of 10 nM. This approach has been validated by the analysis of the lysates of HeLa cells, with an average concentration of 13.7?±?3.5 μM for cytoplasmic Cyt c. Increased concentrations of Cyt c in the HeLa cells treated with etoposide (a commercial drug) or carbon dots (potential drug) have been revealed through this simple, sensitive, and rapid SALDI-MS approach, supporting the drugs induced Cyt c-mediated apoptosis of the cells. This study has shown that this internal standard SALDI-MS approach holds great potential for cell study. Graphical Abstract
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号