首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive and rapid liquid-liquid extraction method for the analysis of nicotinic acid (niacin) and its labeled internal standard nicotinic acid-d4 (niacin-d4) in human plasma was developed and validated. The analyte and its internal standard were isolated from acidified plasma using a single liquid-liquid extraction procedure with methyl-t-butyl ether. The extracted samples were analyzed by liquid chromatography-tandem mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The calibration curves were linear in the measured range between 5 and 1000 ng/mL and the limit of detection was calculated as 122 pg/mL. The method required 250 microL of human plasma and the total run time between injections was 3.5 min. Matrix effects were assessed by post-column infusion experiments, phospholipids monitoring and post-extraction addition experiments. The extraction of phospholipids and niacin from plasma was studied under acidic, neutral and basic conditions. Acidic conditions were optimal for both the recovery of niacin and the removal of phospholipids; the degree of matrix effects for niacin was determined to be 2.5%. It was concluded that effective removal of matrix components can overcome low recovery issues associated with liquid-liquid extractions of polar analytes.  相似文献   

2.
A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride.  相似文献   

3.
A simple, sensitive and rapid high-performance liquid chromatography/positive ion electrospray tandem mass spectrometry (MS/MS) method was developed and validated for the assay of tizanidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the selected reaction monitoring mode. The assay exhibited a linear dynamic range of 50-5000 pg/mL for tizanidine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 13%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

4.
A sensitive high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of clonidine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 230 to 44 for clonidine and m/z 254 to 44 for the internal standard. The assay exhibited a linear dynamic range of 10-2000 pg/mL for clonidine in human plasma. The lower limit of quantification was 10 pg/mL with a relative standard deviation of less than 6.8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

5.
A method has been developed and is described for the quantitative determination of a nonpeptide antithrombotic in dog plasma. The assay employs reversed phase microbore high-performance liquid chromatography in conjunction with tandem mass spectrometry utilizing pneumatically assisted electrospray ionization. The analyte and internal standard are isolated from the plasma matrix by solid-phase extraction. The mass spectrometer is operated in the positive ion multiple reaction monitoring mode and is set to detect the presence of a precursor-product ion pair for both the analyte and internal standard to generate product ion chromatograms for both species. The analyte is quantified by using weighted least-squares regression of the peak height ratio of drug:internal standard. The method provides linear response for plasma concentrations ranging from 5 ng/mL (25 pg on-column) to 2500 ng/mL. Statistical evaluation and examples of authentic sample assays are also presented.  相似文献   

6.
In this study, a sensitive, selective and reproducible liquid chromatography–tandem mass spectrometry method for the simultaneous determination of 1,5‐dicaffeoylquinic acid (1,5‐DCQA) and its active metabolites, 1‐caffeoyl‐5‐feruoylquinic acid and 1,5‐O‐diferuoylquinic acid, in human plasma, using puerarin as internal standard, was developed and validated. Analytes were extracted from plasma samples by liquid–liquid extraction with ethyl acetate, separated on a C18 reversed‐phase column with water containing 5 mM ammonium acetate and acetonitrile as the mobile phase and detected by electrospray ionization mass spectrometry in negative selected reaction monitoring mode. The accuracy and precision of the method were acceptable and linearity was good over the range 1–200 ng/mL for each analyte. In addition, the selectivity, extraction recovery and matrix effect were satisfactory too. The validated LC‐MS/MS method was successfully applied to phase II clinical pharmacokinetic study of 1,5‐DCQA in patients. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A method is proposed for determining rhein (an active metabolite of diacerein) in human blood plasma by reversed-phase high-performance liquid chromatography with UV detection. The analyte was selectively extracted from blood plasma by liquid-liquid extraction with a 5% solution of tert-butyl methyl ether in ethyl acetate. The recovery of rhein is 68 ± 3%, LOQ 100 ng/mL. The stability of the analytes and linearity, selectivity, sensitivity, reproducibility, and accuracy of the developed method are evaluated. The pharmacokinetics of diacerein in the oral administration of drug formulations by 18 healthy volunteers is studied.  相似文献   

8.
(E)-5-(2-Bromovinyl)-2'-deoxyuridine is an antiviral drug that is experimentally used for modulation of the antitumour effect of fluoropyrimidines, such as ftorafur and 5-fluorouracil. The isolation of the analyte, in the presence of 5-fluorouracil, from the matrix is performed either by means of a simple protein precipitation (plasma) or by means of a liquid-liquid extraction with ethyl acetate (urine). Following pretreatment, the analyte is analysed by reversed-phase chromatography and quantified by absorbance detection at 307 nm. The minimum detectable concentration in plasma and urine samples is ca. 6 ng/ml. The recovery after deproteination of plasma samples is 75%, while after liquid-liquid extraction of urine the recovery amounts 92%. The degree of protein binding of the analyte, measured by ultrafiltration, is found to be 97%. These data allow the bioanalysis of (E)-5-(2-bromovinyl)-2'-deoxyuridine for pharmacokinetic studies.  相似文献   

9.
A multi-residue liquid chromatography-mass spectrometry (LC-MS) assay method is described for the determination of four nitroimidazoles in poultry muscle. The extraction procedure is based on liquid-liquid extraction with ethyl acetate followed by an evaporation step. A deuterated internal standard is used. The LC separation was made on a C18 bonded silica column with an aqueous formic acid (0.2%) solution-methanol-acetonitrile (81:13:6) mobile phase. Following electrospray ionization, the protonated molecular ion [M+H]+ is obtained for each compound. Monitoring several ions for each nitroimidazole provides the specificity required for confirmatory assay. Validation of the method was performed to estimate linearity, intra-day and inter-day repeatability, accuracy and detection limit. The present method is capable of identifying nitroimidazole residues in muscle at levels below 5 microg/kg.  相似文献   

10.
A simple, sensitive and rapid high-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry method was developed and validated for the assay of clopidogrel in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 322/212 for clopidogrel and m/z 264/154 for the internal standard. The assay exhibited a linear dynamic range of 5-6000 pg/mL for clopidogrel in human plasma. The lower limit of quantification was 5 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

11.
An ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method for fast‐throughput analysis of eight anabolic and androgenic steroids (AAS) in equine plasma is reported. Analytes were recovered by liquid‐liquid extraction using methyl tert‐butyl ether, separated on a 1.9 µm C18 reversed‐phase column, and analyzed in positive electrospray ionization mode on a triple quadrupole mass spectrometer with selected reaction monitoring (SRM) and full product ion scans. Two SRM ion transitions were monitored for each AAS during screening to obtain highly selective screening results. Full product ion spectra of excellent quality for AAS, at 100 pg/0.5 mL in plasma, devoid of interfering spectra from impurities in plasma, were obtained. To our knowledge, this is the first report on the acquisition of full product ion spectra at such a low analyte concentration and plasma volume using a triple quadrupole instrument. In addition to product ion intensity ratios obtained from three SRM scans for identifying AAS in equine plasma, full product ion spectra were used as supporting evidence for confirmation. For quantification, deuterium‐labeled testosterone and stanozolol were used as internal standards (ISs). The limits of detection, quantification and confirmation were 6.25–12.5 pg/0.5 mL, 25 pg/0.5 mL and 50–100 pg/0.5 mL, respectively. There was no significant matrix effect on the analysis of all eight AAS. Intra‐day precision and accuracy were 2–15% and 91–107%, respectively. Inter‐day precision and accuracy were 1–21% and 94–110%, respectively. Total analysis time was 5 min. To date, the method has been successfully used in the analysis of >12 000 samples for AAS in plasma samples from racehorses competing in the State of Pennsylvania. The method is fast, selective, reproducible, and reliable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
An ultra-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the analysis of oral contraceptive ethinyl estradiol (EE) was developed and validated over the curve range of 2.5-500 pg/mL using 1 mL of human plasma sample. Ethinyl estradiol and the internal standard, ethinyl estradiol tetra-deuterated (EE-d4), were extracted from the plasma matrix with methyl t-butyl ether, derivatized with dansyl chloride and then back-extracted into hexane. The hexane phase was evaporated to dryness, reconstituted and injected onto the LC/MS/MS system. The chromatographic separation was achieved on a Luna C(18) column (50 x 2 mm, 5 micro m) with an isocratic mobile phase of 20:80 (v/v) water:acetonitrile with 1% formic acid. The offline derivatization procedure introduced the easily ionizable tertiary amine function group to EE. This greatly improved analyte sensitivity in electrospray ionization and enabled us to achieve the desired lower limit of quantitation at 2.5 pg/mL. This high sensitivity method can be used for therapeutic drug monitoring or supporting bio-equivalence and drug-drug interaction studies in human subjects.  相似文献   

13.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

14.
The potential for using testosterone and nandrolone esters in racehorses to boost the biological concentrations of these steroids and enhance athletic performance is very compelling and should be seriously considered in formulating regulatory policies for doping control. In order to regulate the use of these esters in racehorses, a sensitive and validated method is needed. In this paper, we report such a method for simultaneous separation, screening, quantification and confirmation of 16 testosterone and nandrolone esters in equine plasma by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Analytes were extracted from equine plasma by liquid-liquid extraction using a mixture of methyl tert-butyl ether and ethyl acetate (50:50, v/v) and separated on a sub-2 micron C(18) column. Detection of analytes was achieved on a triple-quadrupole mass spectrometer by positive electrospray ionization mode with selected reaction monitoring (SRM). Mobile phase comprised 2 mM ammonium formate and methanol. Deuterium-labeled testosterone enanthate and testosterone undecanoate were used as dual-internal standards for quantification. Limits of detection (LOD) and quantification (LOQ) were 25-100 pg/mL and 100-200 pg/mL, respectively. The linear dynamic range of quantification was 100-10,000 pg/mL. For confirmation of the presence of these analytes in equine plasma, matching of the retention time with mass spectrometric ion ratios from MS/MS product ions was used. The limit of confirmation (LOC) was 100-500 pg/mL. The method is sensitive, robust, selective and reliably reproducible.  相似文献   

15.
A confirmatory method has been developed and validated for the determination of chlormadinone acetate (CMA), megestrol acetate (MGA), melengestrol acetate (MLA) and medroxyprogesterone acetate (MPA) in bovine and porcine plasma. Analytes are extracted from plasma samples using matrix-assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal standards. In accordance with Commission Decision 2002/657/EC, two ion transitions were monitored for each analyte. Decision limits (CCalpha) were estimated by analysing 20 blank plasma samples and ranged from 0.1 to 0.2 ng mL(-1). Detection capabilities (CCbeta) were estimated using 20 plasma samples fortified at 0.5 ng mL(-1) and were <0.5 ng mL(-1). In the range 0.5-2 ng mL(-1), the mean intra-laboratory reproducibility of the analytes ranged from 6 to 18% (%R.S.D.). Analytes were shown to be stable in fortified plasma samples for >8 months when stored at -20 degrees C.  相似文献   

16.
A simple, sensitive and specific LC-MS/MS method for the determination of lipoic acid was developed and validated over the linearity range 5-1000 ng/mL (r2 > 0.99) with 200 microL rat plasma using rosigliatzone as an internal standard (IS). The assay procedure involved a simple one-step liquid-liquid extraction of lipoic acid and IS from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Hichrom RPB column (4.6 x 250 mm, 5 microm). Separation of lipoic acid and IS was achieved with a mobile phase consisting of 0.05 M formic acid:acetonitrile (40:60, v/v) at a flow rate of 1.0 mL/min. The API-3000 LC-MS/MS was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique. Positive and negative ion acquisition within the same chromatographic run was used in the present method. For lipoic acid a pseudo-molecular ion transition pair was acquired in negative polarity, whereas for IS the transition pair was acquired in positive polarity. Quantitation was determined for both analyte and IS in MRM scan mode. Absolute recovery of lipoic acid and IS was >70 and 97%, respectively. The lower limit of quantification (LLOQ) of lipoic acid was 5.0 ng/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples 5, 15, 400 and 800 ng/mL were in the range 2.18-5.99% relative standard deviation (RSD) and 0.93-13.77% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.40-114.40% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. Stability of lipoic acid was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats confirmed the utility of the assay.  相似文献   

17.
High-performance liquid chromatography method for the determination of propofol has been developed and validated. Following a liquid extraction using ethyl acetate and hexane, samples were separated by reverse-phase high-performance liquid chromatography on an XBridge C(18) column and quantified using fluorescence detection at an excitation of 276 nm and an emission of 310 nm. The mobile phase was a mixture of water (pH 4.0) and acetonitrile, with a flow rate of 1.5 mL/min. The standard curve ranged from 5-2000 ng/mL. Intra- and inter-assay variability for propofol was less than 10%, and the average recovery was greater than 95%. This assay is suitable for use in pharmacokinetic studies.  相似文献   

18.
A method for the simultaneous determination of a topical carbonic anhydrase inhibitor, L-693,612, and two of its potential metabolites in human whole blood is described. The analytes are isolated from the matrix via liquid-liquid extraction with a mixture of toluene, ethyl acetate and isopropanol (49:50:1, v/v/v). The analytes are then back extracted into dilute phosphoric acid prior to injection into the HPLC system. A cyano column (Zorbax SB-CN, 150 × 4.6 mm) with a mobile phase of phosphoric acid(0.085%)-acetonitrile (73.5:26.5) containing 10 mM sodium decane sulfonate and adjusted to pH 3 is used for the analysis. Detection is based on UV absorbance at 252 nm. The assay was found to be linear in the concentration range of 5–500 ng/ml for each analyte when 1-ml aliquots of whole blood were extracted.  相似文献   

19.
A liquid chromatographic-tandem mass spectrometric assay using 5% bovine serum albumin as the calibration matrix has been developed for the quantitative analysis of 1alpha,25-dihydroxyvitamin D3 [1alpha,25(OH)2D3] in biological fluids. The analyte was extracted from the matrix after protein precipitation using an automated solid-phase extraction procedure involving both a reversed-phase and normal-phase procedure on a single C18 cartridge. The analytical chromatography was performed using a Symmetry C8 50 x 2.1 mm, 3.5 microm column. The mobile phase was a linear gradient from 75 to 99% methanol with a constant concentration of 2 mM ammonium acetate. 1alpha,25(OH)2D3 and the internal standard [2H6]1alpha,25(OH)2D3 were detected by using MS-MS. The ion source was operated in the positive electrospray ionisation mode. The assay is specific, sensitive, and has a capacity of more than 100 samples per day, with a limit of quantitation of 20 pg ml(-1) for a 1.0-ml sample aliquot. The assay has been used for the analysis of 1alpha,25(OH)2D3 in serum from rats and pigs simultaneously with the analysis of the vitamin D analog seocalcitol.  相似文献   

20.
Yang Z  Li X  Wang J  Zhang Q 《色谱》2011,29(9):927-931
建立了同位素稀释质谱测定猪肉中氯霉素残留的方法,对影响溶剂提取、萃取净化、液相色谱-质谱检测方法准确度的因素进行了量化与优化。猪肉样品经液氮冷冻粉碎,加入氯霉素-D5同位素内标和0.1 mol/L醋酸钠缓冲溶液(pH 5),用乙酸乙酯提取4次,正己烷脱脂,HLB固相萃取小柱净化后采用负离子多反应监测模式下的液相色谱-质谱技术检测。方法的线性范围为0.01~0.5 ng/g,相关系数r2大于0.999;检出限和定量限分别为0.004 ng/g和0.02 ng/g;在0.02 ng/g和1.0 ng/g加标水平的回收率(n=3)分别为95.2%~109.1%和99.7%~102.5%;日内和日间相对标准偏差均小于2%。研究了氯霉素及氯霉素-D5的基体效应,测得不同流动相和稀释溶剂组成时基体效应因子k的范围在0.950~1.015之间。研究结果对同位素稀释质谱痕量残留检测结果准确度的控制、方法的建立与验证具有参考意义。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号