首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A microwave digestion method in a closed vessel was developed for the determination of trace metals in atmospheric aerosols using inductively coupled plasma mass spectrometry (ICP-MS). A recovery study for the elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Cd, Sb, and Pb was conducted using multi-elemental standard solutions, NIST 1633b Trace Elements in Coal Fly Ash, and NIST 1648 Urban Particulate Matter. A simple digestion method using only HNO3/H2O2 gave good recoveries (90%-108%) for all elements except Cr in SRM 1648, but yielded low recoveries for SRM 1633b. A more robust method using HNO3/H2O2/HF/H3BO3 yielded higher recoveries (82%-103%) for the lighter elements (V-Zn) in SRM 1633b, and improved the Cr recovery in SRM 1648, but decreased the Se recovery in both SRMs. A comparative analysis of aerosol samples obtained at a remote mountain location Nathiagali, Pakistan (2.5 km above mean sea level), and Mayville, New York, downwind from the highly industrialized Midwestern United States, was carried out using Instrumental Neutron Activation Analysis (INAA) for the elements Cr, Mn, Fe, Co, Zn, As, Se, and Sb. The simple digestion method yielded excellent agreement for Cr, Fe, Zn, As, Se, and Sb, with slopes of the ICP-MS vs. INAA regressions of 0.90-1.00 and R2 values of 0.96-1.00. The regressions for Mn and Co had slopes of 0.82 and 0.84 with R2 values of 0.83 and 0.82, respectively. Addition of HF/H3BO3 did not improve the correlation for any of the elements and degraded the precision somewhat. The technique provides sensitivity and accuracy for trace elements in relatively small aerosol samples used in atmospheric chemistry studies related to SO2 oxidation in cloud droplets. The ability to determine concentrations of a very large number of elements from a single analysis will permit source apportionment of various trace pollutants and hence strategies to control the sources of air pollution. This is particularly important as the health effects of particulate matter are increasingly recognized.  相似文献   

2.
Knowledge of occurrence and concentration of trace elements in dust particulates from and around industrial establishments is essential to know the source of pollutants and atmosphere quality. Dust particulates from two cement factories in the central part of India were analyzed for 5 minor (Cl, Fe, K, Mg, Na) and 23 trace elements (Ag, As, Ba, Br, Cd, Co, Cr, Cs, Dy, Eu, Ga, Hf, Hg, La, Mn, Sb, Sc, Se, Sm, Sr, Th, W and Zn) by INAA and RNAA techniques. Significant differences have been observed for some toxic trace elements at different locations. Mn content is particularly high in all the dust particulates. Urban particulate (SRM 1648) and Coal fly ash (SRM 1633a) from NIST and Pond sediment (CRM No. 2) from NIES were also analyzed. The data have been analyzed and interpreted in terms of air quality at different locations inside the plant and two factories.  相似文献   

3.
NIST standard reference material SRM 2783 was employed to validate a high temperature, high pressure, two-stage microwave assisted acid digestion procedure using HNO3, HF and H3BO3 developed for the analysis of trace elements (including rare earths) in atmospheric fine particulate matter (PM2.5) prior to inductively coupled plasma mass spectrometry (ICP-MS). This method quantitatively solubilized Na, Mg, Al, K, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sb, Cd, Cs, Ba, Pb, Th, U and several rare earth elements (REEs) (La, Ce, Pr, Nd, Gd, Dy, Er, Sm and Eu) from SRM 1648 and SRM 2783. A small amount of HF in the first stage was required to dissolve silicates necessitating the corresponding addition of H3BO3 in second stage to dissolve fluoride precipitates of Mg, La, Ce and Th. The optimized microwave dissolution—ICP-MS method detected Na, Mg, Al, K, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Cd, Mo, Sb, Cs, Ba, La, Ce, Pr, Nd, Sm, Gd, Pb, Th and U at trace to ultra-trace levels in ambient airborne fine particles from three sites in North Carolina. La to light lanthanide signature ratios suggested that soil and motor vehicles are the dominant REE sources in SRM 2783 and PM2.5 samples collected during this study.  相似文献   

4.
Analyses for certification have been made by instrumental neutron activation analysis (INAA) for the determination of 21 elements in the National Institute of Standards and Technology (NIST) Spinach renewal reference material, SRM 1570a. Elements determined included ones with short halflife products (Al, V, Ca, Mg), intermediate halflife products (Mn, Na, K, La), and long halflife products (Ba, Co, Cr, Cs, Eu, Fe, Rb, Sb, Sc, Se, Sr, Th, and Zn). For the first time a new robotic sample changer was used in the counting of long halflife indicator isotopes for certification of an SRM. Uncertainties obtained averaged±1.80% for the four major and minor constituents (Ca, K, Mg, Na); ±3.14% for elements with concentrations from 1 to 400 mg/kg (Al, Ba, Cr, Fe, Mn, Rb, Sr, and Zn); and±8.31% for the ultra trace elements (<1 mg/kg) (Co, Cs, Eu, La, Sb, Sc, Se, Th, and V).  相似文献   

5.
A microwave digestion method suitable for determination of multiple elements in marine species was developed, with the use of cold vapor atomic spectrometry for the detection of Hg, and inductively coupled plasma mass spectrometry for all of the other elements. An optimized reagent mixture composed of 2 ml of HNO3, 2 ml of H2O2 and 0.3 ml of HF used in microwave digestion of about 0.15 g (dry weight) of sample was found to give the best overall recoveries of metals in two standard reference materials. In the oyster tissue standard reference material (SRM 1566b), recoveries of Na, Al, K, V, Co, Zn, Se, Sr, Ag, Cd, Ni, and Pb were between 90% and 110%; Mg, Mn, Fe, Cu, As, and Ba recoveries were between 85% and 90%; Hg recovery was 81%; and Ca recovery was 64%. In a dogfish certified reference material (DORM-2), the recoveries of Al, Cr, Mn, Se, and Hg were between 90% and 110%; Ni, Cu, Zn, and As recoveries were about 85%; and Fe recovery was 112%. Method detection limits of the elements were established. Metal concentrations in flounder, scup, and blue crab samples collected from coastal locations around Long Island and in the Hudson River estuary were determined.  相似文献   

6.
A simple single-step ultrasonic dissolution procedure for low mass (<1?mg) particulate matter (PM) filter samples using HNO3–HF acid solution is proposed for multi-element determination using ICP-MS. The PM-loaded PTFE filter samples are inserted directly into disposable centrifuge tubes for acid extraction using ultrasonic digestion (UD). Potential interferences owing to contamination and element loss are minimized. Key factors influencing element recoveries are investigated, including digestion solution composition, acid concentration, temperature, and matrix interferences. Optimized conditions for UD include an acid mixture consisting of 4.0?mL HNO3 and 0.1?mL HF with ultrasonication proceeding at 90°C for one hour, followed by 10-fold dilution. Recoveries of 80–120% are achieved for almost all of the 20 elements tested (Be, Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Mo, Ag, Cd, Sb, Ba, Pb and U) in four standard reference materials with contrasting matrices: NIST 1648 (urban PM), NIST 2584 (indoor dust), NIST 2710 (soil), and NIST 1633b (coal fly ash). The exception is Cr in NIST 1648 for which recovery is low (30%) using this method. Element concentrations obtained for PM-loaded filter samples using the proposed UD?+?ICP-MS method agree with results obtained using energy dispersive X-ray fluorescence (paired t-test p?>?0.2; 95% CI).  相似文献   

7.
Neutron activation analysis (NAA) methods have been developed for the determination of major, minor and trace elements in duplicate diets and individual food items. These include a cyclic instrumental NAA (CINAA) method for measuring Se content through its short-lived nuclide77mSe; epithermal INAA (EINAA) for I and As; conventional INAA for Br, Ca, Cl, Co, Cr, Fe, K, Mg, Mn, Na, Rb, Sb, Sc, Sn and Zn; combination of EINAA and INAA for Al; radiochemical NAA (RNAA) for As, Au, Co, Cu, Fe, Hg, Mo, Sb, Se and Zn; and preconcentration NAA (PNAA) for U and Th. Accuracy of measurements have been evaluated by analyzing a number of biological and diet reference materials. Multielement concentrations of diets and foods have been measured by these methods.  相似文献   

8.
A microwave-assisted digestion procedure using HNO3, HF, and H2O2 has been developed for analysis of elements in ambient particulate matter (PM). The samples are collected on cellulose filters and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS is calibrated with external standards, and recovery of analytes is tested with NIST SRM 1648 Urban Dust. This method has been used to quantify the airborne concentrations of a large number of elements, including Ag, As, Ba, Be, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, K, Li, Mg, Mn, Mo, Ni, Pb, Rb, Se, Sb, Sr, Ti, Tl, V, and Zn. For the majority of these elements, recovery of the NIST SRM is within 15% of the certified values.  相似文献   

9.
Closed-vessel microwave digestion of nine standard reference plant materials (NIST, BCR, IAEA) and a laboratory standard of plant material with different Si contents assisted by HNO3 + H2O2 (procedure A), HNO3 + H2O2 + HF + H3BO3 (procedure B) and HNO3 + H2O2 + HBF4 (procedure C) were used to determine the recovery of 36 elements by ICP-MS: Ag, Al, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, In, La, Li, Mn, Mo, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sn, Sr, Th, Tl, U, V, W, Y, Zn. Additions of HF + H3BO3 and HBF4 in procedures B and C exceeded by 10% (B1, C1) and 100% (B2, C2) the equivalent concentrations of Si in the samples determined by ICP-OES. Most recoveries of certified elements (e.g., Al*, Cu, Mo*, Rb*, Sb*, Th) decreased significantly (*p ≤ 0.05) with increasing Si content in plant reference materials digested by procedure A, while the recoveries from procedures B and C decreased insignificantly only for Mo and Sb. Digestions B and C gave significantly higher recoveries of Al, Sb, W and REEs, which were tighter to the reference values of these elements. A similar effect was found for Cu, Fe, Li, Ni, Sn, Th, Tl, V, Zn, Ba, Rb and Sr recoveries in samples with Si contents exceeding 2000 μg g−1. If the Si content in plant samples is less than 10 mg g−1, digestion of 0.5 g of plant samples through 0.05 mL of HF and 0.5 mL of 4% H3BO3 or 0.1 mL of HBF4 is recommended to get satisfactory results for most of the elements. For materials with Si content exceeding 10 mg g−1 the weight of the sample for digestion should be reduced to 0.25 g. However, the operation of potential interferences should be taken into account and eliminated through correction equations and adequate dilution of the samples.  相似文献   

10.
Analyses for certification have been made for the determination of 30 elements in the National Institute of Standards and Technology (NIST) Tomato Leaves renewal reference material, SRM 1573a. Three of the analytical techniques used were instrumental neutron activation analysis (INAA), radiochemical neutron activation analysis (RNAA), and prompt gamma activation analysis (PGAA). These techniques provided data on 19 elements by INAA, 10 elements by PGAA, and 7 elements by RNAA, with some overlap between techniques. For example, INAA was able to obtain overall analytical uncerainties (at the 95% confidence level) averaging ±2.2% for major and minor constituents (Ca, Mg, K), ±3.3% for constituents from 1 to 1000 g/g (Na, Fe, Al, Mn, Ba, Zn, Rb, La, Cr), and ±6.4% for elements between 10 and 1000 ng/g (Co, V, Se, Th, Sc, Sb), using sample dry weights of approximately 150 mg. These analyses represent the most extensive use to date of nuclear analytical techniques in the certification of a trace element SRM at NIST.  相似文献   

11.
The optimisation of a micro-analytical two-step sequential leaching procedure for the determination of non-volatile ions (NO3, SO42−, Cl, Na+, Mg2+, NH4+ and Ca2+) and of 17 elements (Al, As, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Pb, S, Se, V, Zn, Sb, Si and Ti) in two fractions—extract and residue—on the same sample of air particulate matter is described. The two-step method was tested on the SRM NIST 1648 for equivalence with two reference methods, the EMEP procedure for ions extraction and the EN 12341 standard for the elemental determination of the PM10 and is suitable for application to small sample amounts (less than 1 mg of particulate matter is needed), i.e. those collected by daily low volume filter-sampling. Performance times of the procedure were optimised to meet the target of routine application for large scale monitoring samples. A single ultrasonic-assisted extraction of air particulate matter is performed in 0.01 M acetate buffer at pH 4.5, followed by IC ions analysis and ICP-OES elemental analysis of the extract and by ICP-OES elemental analysis of the mineralized residue after dissolution by microwave-assisted digestion with a HNO3/H2O2 mixture. Using a pH buffered extracting solvent was preferred to water or diluted acid solutions to improve the reproducibility of metals extraction with respect to existing leaching methods; the influence of pH, nature and concentration of the buffer solution and extraction time on analytes concentration in the extract is discussed. Values of ions extraction and elements recoveries resulted fairly equivalent with those obtained by the reference methods. The study was also extended to some non-certified elements (Mg, S, Sb, Si and Ti) for their environmental significance. Elements recoveries were obtained as sum of the extract and residue fractions and were comparable with those obtained by direct dissolution. Standard deviations were within 10% for almost all detected ions and elements.  相似文献   

12.
A matrix removal procedure has been developed for the determination of trace elements, including As, Cd, Co, Cr, Cu, Hg, Ni, Pb, Sb, Se, Sn, Tl, Zn and V, in siliceous materials by inductively coupled plasma mass spectrometry (ICP-MS). Soil and sediment samples were dissolved in a mixture of HNO3 and HF in sealed vessels by using a microwave oven. Silicon matrix in the solutions was precipitated as sparingly soluble sodium fluorosilicate (Na2SiF6) by adding 0.5 mL of 300 mg mL−1 NaCl solution. Simultaneous precipitation of sodium and silicon was achieved in highly acidic solutions containing 30–40% (v/v) HNO3. A mixture of methanol and nitric acid afforded back-extraction of the trace elements without significant dissolution of the Na2SiF6. Samples were analyzed by ICP-MS for trace elements and residual silicon. Calibration was made by aqueous multi-element standard solutions. Up to 95% of the silicon was successfully removed yielding solutions suitable for introduction to ICP-MS. The method was validated by analysis of two NIST certified reference materials; SRM 2711 (Montana Soil) and SRM 2704 (Buffalo River Sediment). Accurate results were obtained for all elements, including those for As, Hg and Se that suffer from losses due to the presence of their volatile species when silicon was converted to volatile SiF4 via heat-assisted evaporation to dryness. The recoveries from the SRM samples varied between 80% (Cr) and 109% (Hg). No significant interferences were observed from molecular ions of chloride and residual sodium on 75As, 63Cu, 60Ni, 77Se and 51V. Correspondence: Zikri Arslan, Department of Chemistry, Jackson State University, Jackson, MS 39217, USA  相似文献   

13.
The quantitative determination of chemical elements in organic or biological samples is an important analytical problem. Normally the elements to be determined in the organic matrix must be transformed into a simple inorganic form. A digestion method by heating on a block digestor has been developed for the determination of Al, As, Ba, Ca, Cd, Co, Cu, Fe, Mg, Mn, V and Zn in Oyster tissue by ICP OES. A simplex centroid statistical mixture design has been used to study the effects of changing HNO3, HCl and H2O2 reagent proportions on the digestion of these samples. Response surface and principal component analyses show that the species Ca, Cd, Cu, Fe, Mg, Mn and Zn have very similar analytical tendencies under this experiment. By means of mixture modeling maximum recoveries for these ions were predicted using 19%, 18% and 63% of the HCl, HNO3 and H2O2 pseudocomponent mixtures, respectively. This corresponds to 21.4%, 30.8% and 47.8% of the HCl, HNO3 and H2O2 commercial solutions. Furthermore the As, Co and V ions present large recoveries for these mixtures as well. The Al and Ba ion recoveries are seen to be independent of the mixture proportions. The analysis of Oyster tissue reference material (SRM 1566b - NIST) under optimized conditions at the selected wavelengths resulted in ion recoveries between 90% and 100%.  相似文献   

14.
Most of the analytical techniques used to quantify elements associated with solid samples suffer from high detection limits and cannot be used for trace elements in biomass samples, particularly when only 20 mg are available for analysis. Inductively coupled plasma mass spectrometry (ICP-MS) can achieve detection limits of parts-per-trillion with liquid sample introduction by solution nebulisation. This technique was therefore tested with two standard biomass reference materials: oriental tobacco leaves and cabbage leaves. Two preparations successfully used on coal standards were used to digest the solid samples: a total digestion method (wet ashing digestion) and a partial leaching (microwave extraction). The concentrations of up to seventeen elements (As, Ba, Be, Cd, Co, Cr, Cu, Ga, Mn, Mo, Ni, Pb, Sb, Se, Sn, V and Zn) were measured after the two preparations. The accuracy and sensitivity of the measurements improved when the dilution factor decreased from 5000 to 1000 and to 500. Since the proportion of mineral matter in biomass samples is small (5%), the microwave digestion extracted elements that are generally not completely extracted from coal samples (e.g. Sb). However, some trace element concentrations were below the limit of quantification after microwave extraction, even with a reduced dilution factor (As, Se and Mo) and could not be quantified. A fuel oil was also digested. The trace element concentrations were very low (between 28 and 0.1 microgram g(-1)) but acceptable results were obtained by applying a dilution factor of 100. Only six elements in the fuel oil (As, Ba, Co, Ni, Se and V) had certified or indicated values. Factors affecting the accuracy and sensitivity of the analyses are discussed. The reproducibility of analysis of the tobacco leaf standard was checked over a period of nine months by both digestion methods. The wet ashing method gave acceptable reproducibility for Ba, Cd, Co, Cu, Ga, Mn, Mo, Ni, Pb, V and Zn but poor precision for Cr, Se and Sn and showed evidence of residual chloride interference for As. The microwave extraction gave good reproducibility for As, Ba, Cd, Co, Cr, Cu, Mo, Ni and Zn but poor precision for Se and low recoveries for Ga, Mn, Sn and V. In spite of the small quantities of material analysed, it proved possible to determine the trace elements at levels down to 0.1 microgram g(-1) in the reference materials.  相似文献   

15.
Instrumental neutron activation analysis (INAA) was applied to assess element concentrations in eleven samples of mineral supplements/multivitamins acquired in drugstores and pharmacies in São Paulo city, SP, Brazil. Concentrations of Ca, Co, Cr, Cu, Fe, K, Na, Se and Zn were determined. A comparison was made between the results obtained with the labels of the mineral supplents. Certified reference materials, NIST SRM1400 Bone Ash and NIST SRM 1633b Coal Fly Ash were analyzed for quality control of the analytical results.  相似文献   

16.
A robust microwave-assisted acid digestion procedure followed by inductively coupled plasma-mass spectrometry (ICP-MS) was developed to quantify rare earth elements (REEs) in fluidized-bed catalytic cracking (FCC) catalysts and atmospheric fine particulate matter (PM2.5). High temperature (200 °C), high pressure (200 psig), acid digestion (HNO3, HF and H3BO3) with 20 min dwell time effectively solubilized REEs from six fresh catalysts, a spent catalyst and PM2.5. This method was also employed to measure 27 non-REEs including Na, Mg, Al, Si, K, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Zr, Mo, Cd, Cs, Ba, Pb and U. Complete extraction of several REEs (Y, La, Ce, Pr, Nd, Tb, Dy and Er) required HF indicating that they were closely associated with the aluminosilicate structure of the zeolite FCC catalysts. Internal standardization using 115In quantitatively corrected non-spectral interferences in the catalyst digestate matrix. Inter-laboratory comparison using ICP-optical emission spectroscopy (ICP-OES) and instrumental neutron activation analysis (INAA) demonstrated the applicability of the newly developed analytical method for accurate analysis of REEs in FCC catalysts. The method developed for FCC catalysts was also successfully implemented to measure trace to ultra-trace concentrations of La, Ce, Pr, Nd, Sm, Gd, Eu and Dy in ambient PM2.5 in an industrial area of Houston, TX.  相似文献   

17.
Zusammenfassung Das Verhalten der Spurenelemente Au, Cd, Co, Cu, Fe, Ir, La, Mn, Na, Sb, Se, Ta, W und Zn wurde bei der Chlorierung der Niob-Matrix im Cl2-Strom, und nachfolgender Abtrennung der Niob-Säure durch homogene Fällung untersucht. Die optimalen Bedingungen zur Abtrennung der Niob-Matrix von einigen Spurenelementen sowohl bei dem Aufschluß als auch bei der Fällung wurden ermittelt.
Digestion of niobium by chlorination and separation of the trace contaminants from the matrix by homogeneous precipitation
Summary The behaviour of fourteen trace elements (Au, Cd, Co, Cu, Fe, Ir, La, Mn, Na, Sb, Se, Ta, W, and Zn) was investigated during the chlorination of the niobium matrix in a Cl2-stream and in the separation of the niobium acid from a number of trace elements by homogeneous precipitation. The optimum conditions for the separation of the niobium matrix from the trace elements for both steps are given.
  相似文献   

18.
The process of urbanization and industrialization during las two decades has resulted in increased level of air pollution causing hazards to human health. Instrumental neutron activation analysis (INAA) using short and long term irradiation has been employed for the determination of more than 30 elements in suspended particulate matter (SPM) from six metropolitan cities and three industrial surroundings. A comparison of mean elemental contents in dust particulates from commercial, industrial and residential zones of Delhi, Calcutta, Madras, Cochin, Bombay and Nagpur cities has shown wide variation in toxic pollutant (As, Br, Cr, Cu, Hg and Sb) concentrations. Coastal areas have shown higher concentrations of Na, K, Cl and Br. Highly industrialized Bombay showed highest levels of Br, Cl, Cr, Fe, Mg, P, Rb and Sc. Mean elemental contents in fugitive and ambient dust of a cement factory and thermal power station (both in central India) are widely different. SPM levels in fugitive dust of the two industrial surroundings are higher by an order of magnitude compared to ambient air. Analysis of ambient air dust from a paper mill showed highest concentrations of Hg, Sb and Zn. Elemental data have been compared with those of Urban Particulate Matter (SRM 1648), Coal Fly Ash (SRM 1633a) and Vehicle Exhaust Particulate (NIES No. 8) which were analysed for quality control. An attempt has been made to attribute the elemental contents to possible sources of origin.  相似文献   

19.
The elements Mn and V were determined by INAA in about 5 mg and 100 mg aliquots of NIST SRM 1648 to elucidate discrepancies between our previous results for the 0.5 mg to 15 mg aliquots and the NIST certified and/or information values. Simultaneously, other NIST SRMs 1633a, 2704, and BCR CRMs 038, 101 and 143 were also analyzed. Special attention was given to evaluating and minimizing uncertainties of all steps of analysis. Our results compared very well with the respective certified and/or information values (if available) of all SRMs and CRMs studied, except for NIST SRM 1648. For this SRM we have found significantly lower results than the NIST values which suggests that the NIST values are positively biased by about 10%. A new value for V in BCR CRM 143 was also obtained.  相似文献   

20.
《Analytical letters》2012,45(3):509-534
Abstract

The sequential determination of 14 trace metals, Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb, in rain and river water samples has been investigated using an inductively coupled plasma mass spectrometry (ICP-MS) with a graphite rod electrothermal vaporizer (ETV) in the presence of the mixed modifier of palladium nitrate and magnesium nitrate. The sensitivity enhancements due to the presence of the modifier were observed for all analyte elements. Detection limits as high as 0.52, 0.13, 0.89, 0.35, 1.76, 0.5, 0.9, 0.5, 0.04, 1.03, 0.28, 0.07, 0.1 and 3.78 pg, respectively, for Al, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Mo, Cd, Sb and Pb have been achieved. For the determination of trace metals in both rain and river water samples by this method, the repeatibility of sample solution were very good, i.e. from 1% to 7% (as a coefficient variation) and the recoveries of elements were good enough, i.e. from 81% to 106%, by using a standard addition method. There was no difference between the results obtained by nebulizer ICP-MS and those obtained by this method, except for zinc and arsenic.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号