首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 892 毫秒
1.
Green chemistry and sustainability is now entirely encompassed across the majority of pharmaceutical companies and research labs. Researchers’ attention is careworn toward implementing the green analytical chemistry principles for more eco‐friendly analytical methodologies. Solvents play a dominant role in determining the greenness of the analytical procedure. Using safer solvents, the greenness profile of the methodology could be increased remarkably. In this context, a green chromatographic method has been developed and validated for the simultaneous determination of phenylephrine, paracetamol, and guaifenesin in their ternary pharmaceutical mixture. The chromatographic separation was carried out using monolithic column and green solvents as mobile phase. The use of monolithic column allows efficient separation protocols at higher flow rates, which results in short time of analysis. Two‐factor three‐level experimental design was used to optimize the chromatographic conditions. The greenness profile of the proposed methodology was assessed using eco‐scale as a green metrics and was found to be an excellent green method with regard to the usage and production of hazardous chemicals and solvents, energy consumption, and amount of produced waste. The proposed method improved the environmental impact without compromising the analytical performance criteria and could be used as a safer alternate for the routine analysis of the studied drugs.  相似文献   

2.
A fast, green, sensitive, and accurate analytical method using high‐performance liquid chromatography couple with fluorescence detection was established and validated for the simultaneous determination of amlodipine besylate and celecoxib in their recently approved fixed‐dose combination tablets (1:20). Separation of the two drugs was achieved on C18 reversed‐phase column (Thermo ODS Hypersil, 4.6 × 250 mm, particle size 5 µm) using acetonitrile:potassium phosphate buffer (50 mM; pH 5.5, 60:40 v/v) as a mobile phase at 40°C, which eluted at a rate of 1 mL/min. Detection was carried out with excitation and emission wavelengths of 360 and 446 nm for amlodipine and 265 and 359 nm for celecoxib, respectively. The method was linear over a concentration range of 0.05‐2 and 0.05‐10 µg/mL and limit of detection reached to 0.017 and 0.0167 µg/mL for amlodipine and celecoxib, respectively. The developed method was successfully applied to assess the cited drugs in their newly FDA approved fixed‐dose combination tablet dosage form. Furthermore, the method was found to be sensitive and eco‐friendly green alternative to the reported methods as it was evaluated according to the green analytical procedure index tool guidelines and analytical Eco‐Scale.  相似文献   

3.
Determination of a widely used antihypertensive combination of atenolol and hydrochlorothiazide was achieved by rapid and eco-friendly high-performance liquid chromatography method combined with fluorescence detection. The response surface methodology is conducive to the complete separation of the two drugs in a shorter analysis time. The separation of the mixture was achieved using an Inertsil C18 analytical column (150 × 4.6 mm, 5 µ). The mobile phase used was ethanol: potassium dihydrogen phosphate at pH 3 (65:35 v/v) and the flow rate was 0.7 mL/min. The fluorescence detector operated at excitation and emission wavelengths of 230 and 310 nm (atenolol) and 270 and 375 nm (hydrochlorothiazide). The linearity of the developed method covered a concentration of atenolol of 0.05–5 µg/mL and a concentration of hydrochlorothiazide of 0.02–1 µg/mL. The greenness of the developed method was evaluated by analytical eco-scale and the recently reported evaluation method, that is, green analytical procedure index, and it was found to be an excellent, sensitive, and green alternative to the reported methods. The developed method was validated according to the ICH guidelines and compared with the reference method. No significant difference was found in terms of accuracy.  相似文献   

4.
Nowadays, Green Analytical Chemistry is widely applied to provide various analytical methods with eco-friendly procedures employing the least toxic, harmful reagents on humans and the environment without affecting the efficacy of the determination. Accordingly, two eco-friendly, accurate, and reliable high-performance thin-layer chromatography-densitometry and high-performance liquid chromatographic methods were established for the determination and separation of two antispasmodic drugs, namely phloroglucinol and trimethylphloroglucinol in their pure, combined dosage form along with phloroglucinol toxic impurity, 3,5-dichloroaniline. For high-performance thin-layer chromatography-densitometry, efficient separation was developed via utilizing the stationary phase of high-performance thin-layer chromatography silica gel 60 F254 plates and developing a system comprising of ethyl acetate-butanol-ammonia in the ratio of 8.0:2.0:0.2, by volume and scanning of the developed bands at 210.0 nm. The subsequent method is isocratic high-performance liquid chromatography with diode array detection in which separation was successively attained using XTerra RP-C18 (250 × 4.6 mm, 5 μm) column as stationary phase and methanol-10.0 mM phosphate buffer, pH 3.7 ± 0.1 as mobile phase in the ratio of 75.0:25.0, v/v at flow rate 1.0 ml/min and scanning at 220.0 nm. The developed liquid chromatography methods were validated according to the International Council for Harmonization guidelines, and all results acknowledged their efficacy. Additionally, the proposed methods worked well for assessing the cited drugs in binary combined commercially available pharmaceutical formulation. The greenness profile of the present methods was assessed and estimated using various assessment tools, namely; Green Analytical Procedure Index, analytical eco-scale method, National Environmental Method Index in addition to Analytical GREEnness tool to evaluate the greenness of the provided methods with a statistical comparison between them to assess the more green ones.  相似文献   

5.
Minimizing the amount of organic solvents without loss in chromatographic performance has been an important step toward greening analytical methodologies. Mobile‐phase composition is the key for maintaining separation efficiency in liquid chromatography while decreasing the procedure hazardousness. If sodium dodecyl sulfate is mixed with Brij‐35 in the mobile phase, they could be used as a green alternative for using organic modifiers. In this research, the effect of changing the relative amounts of both surfactants was studied on the chromatographic performance and separation efficiency of ten antihypertensive drugs belonging to different categories. The use of surfactants has many advantages including low cost and toxicity, safe environmental disposal, unique selectivity besides high solubilization capabilities. The optimum separation was maintained using a mobile phase (0.01 M Brij‐35, 0.08 M sodium dodecyl sulfate and 0.01 M sodium dihydrogen phosphate/pH 5) on reversed‐phase C18 core–shell column at flow rate 1.5 mL/min and temperature 30°C. The method was successfully applied for the determination of the drugs in various marketed dosage forms. International Conference of Harmonization guidelines were followed to validate the developed method. Additionally, the method was verified on the Green Analytical Procedure Index in regards to the greenness and found to be an excellent green alternative method.  相似文献   

6.
Currently, analytical scientists are paying special attention to reducing reliance on hazardous chemicals in various analytical methods. By embracing this concept, we developed an eco-friendly high-performancethin-layer chromatography (HPTLC) method as an alternative for the conventional HPLC method for the determination of an essential human micronutrient, niacin (NIA), which is used improve the lipid profile of patients. Furthermore, the proposed HPTLC method is capable of determining the structurally related impurities of NIA such as pyridine-2,5-dicarboxylic acid, isonicotinic acid, pyridine, and 5-ethyl-2-methylpyridine, which exhibit nephrotoxic and hepatotoxic effects. The separation of this challenging mixture was achieved on HPTLC sheets using a mixture of ethyl acetate/ethanol/ammonia solution (6:4:0.05, v/v/v), and then the dried plates were scanned at 254 nm. The analytical eco-scale assessment protocol was used to assess the greenness profile of the presented method and compare it with the reported HPLC method. The suggested method was found to be greener with regard to the consumption of solvents and the yielding of waste. The results suggest that the described method can be safely implemented for the routine analysis of NIA pharmaceutical dosage without the interference of potential impurities in quality control laboratories.  相似文献   

7.
Citicoline and piracetam were subjected separately to different stress conditions as recommended by the international conference on harmonization. In addition, new stability indicating thin layer chromatographic and ultra high performance liquid chromatographic methods have been developed and validated for simultaneous determination of citicoline and piracetam in presence of their degradation products. Separation on the proposed thin layer chromatographic method was carried out using a developing system containing methanol:chloroform:ammonium chloride buffer (9:1:2, v/v/v) on silica gel plates at 230 nm. On the other hand, the mobile phase in the ultra high performance liquid chromatographic method was composed of water (containing 0.1% triethylamine):ethanol (92:8, v/v). The flow rate was 1 mL/min and ultraviolet detection was at 230 nm. Moreover, results of the developed methods were statistically compared to those obtained by the reported high‐performance liquid chromatography method and no significant difference between them was found. The greenness profile of ultra high performance liquid chromatographic method was assessed and compared with those of the previously published high‐performance liquid chromatography methods, it was noticed that the proposed ultra high performance liquid chromatographic method more environmentally friendly and greener than other methods.  相似文献   

8.
High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C(18) analytical column with a mobile phase consisting of a mixture of 20mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ((1)DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.  相似文献   

9.
Dispersive liquid–liquid microextraction has been proposed as an extraction technique combined with micellar electrokinetic chromatography (MEKC) for the analysis of eight 5‐nitroimidazole compounds, including some metabolites, in water samples. Determination has been carried out using a diode array detector, employing 20 mM sodium phosphate and 150 mM SDS as separation buffer. Separation has taken place under a voltage of 25 kV and a temperature of 20°C. Samples were prepared in a buffer without micelles and they were hydrodynamically injected at 50 mbar for 25 s, producing a sweeping effect on the analytes for increasing sensitivity. Different factors involved in the dispersive liquid–liquid microextraction procedure were optimized, such as sample pH, nature, and volume of extraction and dispersive solvents in the mixture, percentage of NaCl added to sample and shaking time after the injection of the extraction and dispersive solvents. The method was characterized for water samples, achieving detection limits lower than 2.4 μg/L. Trueness was checked in river, tap, and bottled water. Dispersive liquid–liquid microextraction combined with MEKC constitutes an easy, cheap, and green alternative for 5‐nitroimidazole analysis in environmental water samples.  相似文献   

10.
The introduction of sustainable development concepts to analytical laboratories has recently gained interest, however, most conventional high‐performance liquid chromatography methods do not consider either the effect of the used chemicals or the amount of produced waste on the environment. The aim of this work was to prove that conventional methods can be replaced by greener ones with the same analytical parameters. The suggested methods were designed so that they neither use nor produce harmful chemicals and produce minimum waste to be used in routine analysis without harming the environment. This was achieved by using green mobile phases and short run times. Four mixtures were chosen as models for this study; clidinium bromide/chlordiazepoxide hydrochloride, phenobarbitone/pipenzolate bromide, mebeverine hydrochloride/sulpiride, and chlorphenoxamine hydrochloride/caffeine/8‐chlorotheophylline either in their bulk powder or in their dosage forms. The methods were validated with respect to linearity, precision, accuracy, system suitability, and robustness. The developed methods were compared to the reported conventional high‐performance liquid chromatography methods regarding their greenness profile. The suggested methods were found to be greener and more time‐ and solvent‐saving than the reported ones; hence they can be used for routine analysis of the studied mixtures without harming the environment.  相似文献   

11.
Multivariate spectrophotometric calibration and liquid chromatography (LC) methods were used for the simultaneous determination of the active ingredients in 2 multicomponent mixtures containing chlorpheniramine maleate and phenylpropanolamine hydrochloride with ibuprofen and caffeine (mixture 1) or with propyphenazone (mixture 2). For the multivariate spectrophotometric calibration methods, principal component regression (PCR) and partial least squares (PLS-1), a calibration set of the mixtures consisting of the components of each mixture was prepared in distilled water. A leave-1-out cross-validation procedure was used to find the optimum numbers of latent variables. Analytical parameters such as sensitivity, selectivity, analytical sensitivity, limit of quantitation, and limit of detection were determined for both PLS-1 and PCR. The LC method depends on the use of a cyanopropyl column with the mobile phase acetonitrile-12 mM ammonium acetate, pH 5.0 (25 + 75, v/v), for mixture 1 or acetonitrile-10 mM potassium dihydrogen phosphate, pH 4.7 (45 + 55, v/v), for mixture 2; the UV detector was set at 212 nm. In spite of the presence of a high degree of spectral overlap of these components, they were rapidly and simultaneously determined with high accuracy and precision, with no interference from the matrix excipients. The proposed methods were successfully applied to the analysis of pharmaceutical formulations and laboratory-prepared mixtures containing the 2 multicomponent combinations.  相似文献   

12.
Multivariate spectrophotometric calibration and liquid chromatographic (LC) methods were applied to the determination of 2 multicomponent mixtures containing diprophylline, guaiphenesin, methylparaben, and propylparaben (Mixture 1), or clobutinol, orciprenaline, saccharin sodium, and sodium benzoate (Mixture 2). For the multivariate spectrophotometric calibration methods, principal component regression (PCR) and partial least-squares regression (PLS-1), a calibration set of the mixtures consisting of the components of each mixture was prepared in 0.1 M HCl. Analytical figures of merit such as sensitivity, selectivity, limit of quantitation, and limit of detection were determined for both PLS-1 and PCR. The LC separation was achieved on a reversed-phase C18 analytical column by using isocratic elution with 20 mM potassium dihydrogen phosphate, pH 3.3-acetonitrile (55 + 45, v/v) as the mobile phase and UV detection at 260 and 220 nm for Mixture 1 and Mixture 2, respectively. The proposed methods were validated and successfully applied to the analysis of pharmaceutical formulations and laboratory-prepared mixtures containing the 2 multicomponent combinations.  相似文献   

13.
White analytical chemistry is a novel concept for the assessment of analytical methods on basis of its validation efficiency, greenness power, and economical efficiency. White analytical chemistry-driven stability indicating chromatographic method has been developed for the concomitant analysis of thiocolchicoside and aceclofenac. The proposed chromatographic method has been developed using a safe and environmental-friendly organic solvents for the concomitant stability study of thiocolchicoside and aceclofenac. The analytical risk assessment was carried out for the identification of high-risk analytical risk factors and analytical method performance attributes. The mixture design was applied for the design of experiments-based response surface modeling of high-risk analytical risk factors and analytical method performance attributes. The degradation products were isolated and characterized using infrared, nuclear magnetic resonance, and mass spectral data. The proposed method was compared for its validation efficiency, greenness power, and cost-efficiency with published chromatographic methods using the red, green, and blue models. The white score of the proposed and reported method was calculated by averaging the red, green, and blue scores of the methods. The proposed method was found to be robust, green, and economical for the concomitant stability study of thiocolchicoside and aceclofenac.  相似文献   

14.
Modern analytical procedures often include impurity profiling to verify the potency, safety, and effectiveness of new formulations. We had to develop techniques based on green analysis since the detrimental influence of solvents and chemicals on the environment has now become a serious concern. Two selective, sensitive, and green liquid chromatography methods were established and fully validated for quantitation of tamsulosin hydrochloride and solifenacin succinate along with four of their official and/or related impurities namely; tamsulosin sulfonic acid, tamsulosin impurity H, solifenacin impurity A and solifenacin impurity C. The first used high-performance thin-layer chromatography with silica gel 60 F254 plates as the stationary phase and an elution system of ethyl acetate:butanol:glacial acetic acid (10.0:0.4:0.1, by volume) and a scanning wavelength of 225.0 nm. The second method depended on HPLC with diode array detection. Chromatographic separation was accomplished on a Zorbax SB C18 (250 × 4.6 mm2, 5 μm) column utilizing a mixture of 10.0 mM sodium dihydrogen phosphate (pH 3.0, adjusted by o-phosphoric acid) and methanol, at a flow rate of 0.8 mL/min in a gradient elution mode and then the separated peaks were scanned at a wavelength of 225.0 nm. To assess the greenness profile, three distinct methodologies were applied.  相似文献   

15.
In recent years, the use of human saliva for diagnostic purposes has evoked great interest. Thus, the aim of this study was to choose the optimal solid‐phase extraction cartridges and extraction solvents for the quantitation of venlafaxine in saliva. Blank saliva samples spiked with venlafaxine concentrations between 25 and 750 ng/mL were analyzed using five solid‐phase extraction columns (C18, C8, Strata‐X, Strata‐X‐C, and Strata‐X‐AW), washing solvents (deionized water, phosphate buffer at pH 5.5, and their mixtures with methanol), and elution solvents (methanol, acetonitrile, and their mixtures with 25% ammonia). A high‐performance liquid chromatography system was used to quantify venlafaxine in saliva. The results of this study revealed that nine of 25 procedures enabled quantitation of venlafaxine in the tested concentration range. The procedure that used a C18 cartridge, a mixture of methanol and deionized water as the washing solvent, and methanol as the elution solvent was the most effective and allowed quantitation of all venlafaxine concentrations with an acceptable recovery. In contrast, the Strata‐X‐C cartridge could not detect venlafaxine at the lowest concentration (25 ng/mL). The data acquired from the high‐performance liquid chromatography system were confirmed by a multivariate data analysis.  相似文献   

16.
Three methods were applied for the analysis of 2 multicomponent mixtures containing dextromethorphan hydrobromide, phenylephrine hydrochloride, chlorpheniramine maleate, methylparaben, and propylparaben, together with either sodium benzoate (Mix 1) or ephedrine hydrochloride and benzoic acid (Mix 2). In the first method, liquid chromatography was used for their simultaneous determination using an ODS column with a mobile phase consisting of acetonitrile-phosphate buffer, pH 2.7 (40 + 60, v/v), containing 5mM heptanesulfonic acid sodium salt and ultraviolet (UV) detection at 214 nm. Also, 2 chemometric methods, principal component regression, and partial least squares were used. For both chemometric calibrations, a concentration set of the mixture consisting of each compound in each mixture was prepared in distilled water. The absorbance data in the UV spectra were measured for the 76 or 71 wavelength points in the spectral region 210-240 or 210-224 nm considering the intervals of deltagamma = 0.4 or 0.2 nm for Mix 1 and Mix 2, respectively. The 2 chemometric methods did not require any separation step. These methods were successfully applied for the analysis of the 2 multicomponent combinations in synthetic mixtures and in commercial syrups, and the results were compared with each other.  相似文献   

17.
Ionic liquid and buffer mixture media are first reported in the peroxidase‐catalyzed polymerization of phenol. Yield of 100% with molecular weights of 7000 KDa, as assessed by size‐exclusion chromatography (SEC), were attained using 1‐butyl‐3‐methylimidazolium tetrafluoroborate–buffer mixtures with added hydrogen peroxide. The simplicity of the process and the low vapor pressure of the solvent media allow an eco‐friendly alternative to the general synthesis of polyphenolic‐type biopolymers. Evidence for the consequent polyphenol (PPO) was obtained from solid‐state 13C cross‐polarization magic angle spinning (CP‐MAS) NMR spectroscopy and FT‐IR. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
Deep eutectic solvents are considered as new and green solvents that can be widely used in analytical chemistry such as microextraction. In the present work, a new dl‐ menthol‐based hydrophobic deep eutectic solvent was synthesized and used as extraction solvents in an air‐assisted dispersive liquid–liquid microextraction method for preconcentration and extraction of benzophenone‐type UV filters from aqueous samples followed by high‐performance liquid chromatography with diode array detection. In an experiment, the deep eutectic solvent formed by dl‐ menthol and decanoic acid was added to an aqueous solution containing the UV filters, and then the mixture was sucked up and injected five times by using a glass syringe, and a cloudy state was achieved. After extraction, the solution was centrifuged and the upper phase was subjected to high‐performance liquid chromatography for analysis. Various parameters such as the type and volume of the deep eutectic solvent, number of pulling, and pushing cycles, solution pH and salt concentration were investigated and optimized. Under the optimum conditions, the developed method exhibited low limits of detection and limits of quantitation, good linearity, and precision. Finally, the proposed method was successfully applied to determine the benzophenone‐type filters in environmental water samples with relative recoveries of 88.8–105.9%.  相似文献   

19.
Hexokinases play a critical role in the cellular uptake and utilization of glucose. As such, they are of fundamental importance to all cells. By catalyzing glucose to produce glucose‐6‐phosphate, hexokinases control the first irreversible step of glucose metabolism and initiate all major pathways of glucose consumption. Our objective was to develop and validate highly sensitive and selective high‐performance liquid chromatography with photodiode array detector (HPLC‐PDA) assays allowing the determination of adenosine diphosphate, which was used for the determination of hexokinase activity. Samples were analyzed by HPLC‐PDA using a C18 analytical column (250 × 4.6 mm) for chromatographic separation. Optimal detection was achieved based on isocratic elution with a mobile phase consisting of a mixture of sodium phosphate monobasic buffer and methanol. This method met all of the requirements of specificity, sensitivity, linearity, precision, accuracy and stability generally accepted in bioanalytical chemistry and was successfully applied to a study of hexokinase activity in an alloxan‐induced diabetic rat model. Determination of hexokinase activity will permit characterization of cellular metabolic state in many diseases, such as cancer and diabetes.  相似文献   

20.
In this study, the application of a mixture of organic solvents as a supported liquid membrane for improving the efficiency of the electromembrane extraction procedure was investigated. The extraction process was followed by high‐performance liquid chromatography analysis of two model drugs (verapamil and riluzole). In this research, four organic solvents, including 1‐heptanol, 1‐octanol, 2‐nitrophenyl octyl ether, and 2‐ethyl hexanol, were selected as model solvents and different binary mixtures (v/v 2:1, 1:1 and 1:2) were used as the supported liquid membrane. The mixture of 2‐ethyl hexanol and 1‐otanol (v/v, 2:1) improved the extraction efficiency of model drugs by 1.5 to 12 times. It was found that extraction efficiency is greatly influenced by the level of electric current. In this study, for various mixtures of organic solvents, the electric current fluctuated between 50 and 2500 μA, and the highest extraction efficiencies were obtained with low and stable electric currents. Finally, the optimized extraction condition was validated and applied for the determination of model drugs in urine and wastewater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号