首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.

Purpose

To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease.

Materials and methods

We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, and 34 benign lesions (≤ 2.0 cm), and 22 patients with cirrhosis but no focal liver lesion who underwent 3.0 T liver MRI. Noncontrast MRI set (T1- and T2-weighted images and DWI) and standard MRI set (gadoxetic acid-enhanced and noncontrast MRI) were analyzed independently by three observers to detect liver malignancies using receiver operating characteristic analysis.

Results

The Az value of the noncontrast MRI (mean, 0.906) was not inferior to that of the combined MRI (mean, 0.924) for detecting malignancies by all observers (P > 0.05). For each observer, no significant difference was found in the sensitivity and specificity between the two MRI sets for detecting liver malignancies and distinguishing them from benign lesions (P > 0.05), whereas negative predictive value was higher with the combined MRI than with the noncontrast MRI (P = 0.0001). When using pooled data, the sensitivity of the combined MRI (mean 94.8%) was higher than that of the noncontrast MRI (mean, 91.7%) (P = 0.001), whereas specificity was equivalent (78.6% vs 77.5%).

Conclusion

Noncontrast MRI including DWI showed reasonable performance compared to the combined gadoxetic acid-enhanced and noncontrast MRI set for detecting HCC and cholangiocarcinoma and differentiating them from benign lesions in patients with chronic liver disease.  相似文献   

2.

Objectives

Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions.

Methods

90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤ 1.44 × 10- 3 mm2/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated.

Results

In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of  > 1.44 and 37 (70%) with ADC ≤ 1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively.

Conclusion

DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement.  相似文献   

3.

Purpose

To evaluate the diagnostic performance of an apparent diffusion coefficient (ADC) and quantitative kinetic parameters in patients with newly diagnosed breast cancer.

Materials and Methods

We enrolled 169 lesions in 89 patients with breast cancer who underwent dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI). Comparisons between benign and malignant lesions were performed for lesion type (mass or nonmass-like enhancement), size (≥ 1 cm or < 1 cm), ADC, kinetic parameters and the presence of a US correlate.

Results

There were 63 benign and 106 malignant lesions. The mean size and initial peak enhancement of the benign lesions were significantly lower than those of malignant lesions (P < 0.001 for both). The ADC of the benign lesions was significantly higher than that of malignant lesions (1.42 × 10− 3 mm2/sec vs. 1.04 × 10− 3 mm2/sec; P < 0.001). The area under the receiver operating characteristic curve (AUC) for predicting malignancy was 0.87 for the combined parameters of size, ADC, and initial peak enhancement, which was higher than those of each parameter.

Conclusions

Combination of quantitative kinetic parameters and ADC showed higher diagnostic performance for predicting malignancy than each parameter alone for the evaluation of patients with breast cancer.  相似文献   

4.

Purpose

To investigate the value of apparent diffusion coefficient (ADC) to predict and monitor the therapy response for cervical cancer patients receiving concurrent radiochemotherapy, and to analyze the influence of different b-value combinations on ADC-based evaluation of treatment response.

Material and Methods

Seventy-five cervical cancer patients treated with radiochemotherapy received conventional MRI and DWI prior to therapy, after 2 weeks of therapy, after four weeks of therapy and after therapy completion. Treatment response was classified as complete response (CR, n = 35), partial response (PR, n = 22) and stable disease (SD, n = 18), which was determined according to final tumor size after 6 months of therapy completion. Dynamic changes of apparent diffusion coefficients (ADC) and tumor size in the three tumor groups were observed and compared. All the ADCs were calculated from b = 0, 600 s/mm2 and b = 0, 1000 s/mm2.

Results

The ADC increased percentage was higher in CR group than those in PR and SD groups after two weeks and four weeks of therapy, with significant differences in absolute ADCs between CR and PR, SD groups after therapy completion; the overall discriminatory capability for differentiation of CR and PR, SD groups was higher for high b-value combination (0, 1000 s/mm2) than for low b-value combination (0, 600 s/mm2).

Conclusion

DWI can be used as a predictive and monitoring biomarker of treatment response to radiochemotherapy in patients with cervical cancer. High b-value combination may be more reliable to evaluate the treatment response for cervical cancer.  相似文献   

5.

Purpose

To present diffusion and perfusion magnetic resonance imaging (MRI) characteristics of focal nodular hyperplasia (FNH) of the liver.

Materials and Methods

Thirty-five patients with 52 FNHs (21 were pathologically-confirmed) underwent MRI at 1.5-T device. MR diffusion [diffusion-weighted imaging (DWI)] was performed using a free-breathing single-shot, spin-echo, echo-planar sequence with b gradient factor value of 500 s/mm². MR perfusion [perfusion-weighted imaging (PWI)] consisted of a 3D free-breathing LAVA sequence repeated up to 5 minutes after injection of 7 mL Gd-BOPTA (MultiHance, Bracco, Italy) and 20 mL saline flush at a flow rate of 4 mL/s. Apparent diffusion coefficient (ADC) and time-signal intensity curve (TSIC) were obtained for both normal liver and each FNH by two reviewers in conference; maximum enhancement (ME) percentage, time to peak enhancement (TTP), and maximal slope (MS) were also calculated.

Results

On DWI mean ADC value was 1.624×10− 3 mm2/s for normal liver and 1.629×10− 3 mm2/s for FNH. ADC value for each FNH and the normal liver was not statistically different (P= .936). On PWI, TSIC-Type 1 (quick and marked enhancement and quick decay followed by slowly decaying) was observed in all 52 FNHs, and TSIC-Type 2 (fast enhancement followed by slowly decaying plateau) in all normal livers. The mean ME, TTP and MS values were significantly different for FNH and normal liver (P= .005).

Conclusion

FNHs of the liver showed typical diffusion and perfusion MRI characteristics in all cases. On the ADC map, we could get similar value between the FNHs and the background parenchyma. On the perfusion imaging, FNHs showed a different pattern distinguished from the background liver.  相似文献   

6.

Objectives

To investigate and optimize diffusion-weighted imaging (DWI) acquisitions for pancreatic cancer at 3.0 T.

Methods

Forty-five patients with pancreatic cancer were examined by four DWI acquisitions with b values = 0 and 600 s/mm2 at 3.0 T, including breath-holding DWI (BH-DWI), respiratory-triggered DWI (TRIG-DWI), respiratory-triggered DWI with inversion–recovery technique (TRIGIR-DWI), and free-breathing DWI with inversion–recovery technique (FBIR-DWI). Artifacts, contrast ratio (CR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of pancreatic cancer were statistically compared among DWI acquisitions.

Results

TRIGIR-DWI displayed the lowest artifacts and highest CR compared to other DWI acquisitions. CNRs of pancreatic cancer in TRIG-DWI and TRIGIR-DWI were statistically higher than that in FBIR-DWI and BH-DWI. Different ADCs between pancreatic cancer and noncancerous pancreatic tissues were noticed by a paired-samples T test in TRIG-DWI (p = 0.017), TRIGIR-DWI (p = 0.00001) and FBIR-DWI (p = 0.000041).

Conclusions

TRIGIR-DWI may be the optimal acquisition of DWI for pancreatic cancer at 3.0 T.  相似文献   

7.

Purpose

To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images.

Methods

A 3 T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test.

Results

Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P = 0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P = 0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P = 0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes.

Conclusions

Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization.  相似文献   

8.

Purpose

Body fat distribution changes are associated with multiple alterations in metabolism. Therefore, the assessment of body fat compartments by MRI in animal models is a promising approach to obesity research. Standard T1-weighted (T1w) whole body MRI was used here to quantify different effects in the subcutaneous and visceral fat compartments in rats under treatment with an anorexiant.

Materials and methods

Twenty rats on a high caloric diet were investigated by the identical MRI protocol at baseline and after seven weeks. Ten rats received a treatment with sibutramine, 10 rats served as vehicle control group. To longitudinally assess body fat components, MRI analysis was used with two approaches: 2D slicewise graphic analysis (SGA) was compared with an automated 3D analysis algorithm (3DA).

Results

At the group level, fat volume differences showed a longitudinal increase of subcutaneous and visceral fat volumes for the control group, whereas the sibutramine group showed stable subcutaneous fat volumes and decrease in visceral fat volumes. SGA and 3DA volume determination showed significant correlations for subcutaneous fat volume (C = 0.85, p < 0.001), visceral fat volume (C = 0.87, p < 0.001), and total fat volume (C = 0.90, p < 0.001).

Conclusion

It could be demonstrated that computer-based analysis of T1w MRI could be used to longitudinally assess changes in body fat compartments in rats at the group level. In detail, it was possible to investigate the effect of sibutramine separate on the fat compartments in rats.  相似文献   

9.

Purpose

To evaluate the use of the intravoxel incoherent motion (IVIM) technique in half-Fourier single-shot turbo spin-echo (HASTE) diffusion-weighted imaging (DWI), and to compare its accuracy to that of apparent diffusion coefficient (ADC) to predict malignancy in head and neck tumors.

Patients and methods

HASTE DW images of 33 patients with head and neck tumors (10 benign and 23 malignant) were evaluated. Using the IVIM technique, parameters (D, true diffusion coefficient; f, perfusion fraction; D*, pseudodiffusion coefficient) were calculated for each tumor. ADC values were measured over a range of b values from 0 to 1000 s/mm2. IVIM parameters and ADC values in benign and malignant tumors were compared using Student's t test, receiver operating characteristics (ROC) analysis, and multivariate logistic regression modeling.

Results

Mean ADC and D values of malignant tumors were significantly lower than those of benign tumors (P < 0.05). Mean D* values of malignant tumors were significantly higher than those of benign tumors (P < 0.05). There was no significant difference in mean f values between malignant and benign tumors (P > 0.05). The technique of combining D and D* was the best for predicting malignancy; accuracy for this model was higher than that for ADC.

Conclusions

The IVIM technique may be applied in HASTE DWI as a diagnostic tool to predict malignancy in head and neck masses. The use of D and D* in combination increases the diagnostic accuracy in comparison with ADC.  相似文献   

10.

Purpose

To compare the image quality of three techniques and diagnostic performance in detecting implant rupture.

Materials and Methods

The study included 161 implants for the evaluation of image quality, composed of water-saturated short TI inversion recovery (herein called “water-sat STIR”), three-point Dixon techniques (herein called “Dixon”), and short TI inversion recovery fast spin-echo with iterative decomposition of silicone and water using least-squares approximation (herein called “STIR IDEAL”) and included 41 implants for the evaluation of diagnostic performance in detecting rupture, composed of water-sat STIR and STIR IDEAL.Six image quality categories were evaluated and three classifications were used: normal implant, possible rupture, and definite rupture.

Results

Statistically significant differences were noted for the image quality categories (p < 0.001). STIR IDEAL was superior or equal to water-sat STIR in all image quality categories except artifact effects and superior to Dixon in all categories. Water-sat STIR performed the poorest for water suppression uniformity.The sensitivity and specificity in detecting implant rupture of STIR-IDEAL were 81.8 % and 77.8 % and the difference between two techniques was not statistically significant.

Conclusion

STIR-IDEAL is a useful silicone-specific imaging technique demonstrating more robust water suppression and equivalent diagnostic accuracy for detecting implant rupture, than water-sat STIR, at the cost of longer scan time and an increase in minor motion artifacts.  相似文献   

11.

Purpose

To compare diffusion weighted imaging with background suppression (DWIBS) sequence with classic spectral diffusion sequence (DWI) with and without respiratory gating in mediastinal lymph node analysis at 3 T.

Materials and methods

26 patients scheduled for mediastinoscopic lymph node analysis, prospectively undergone a thoracic 3 T MRI with DWIBS (FatSat = STIR; TR/TE = 6674.1/44.7 ms; IR = 260 ms) and DWI sequences (FatSat = SPIR; TR/TE = 1291/59.6 ms) (b = 0-400-800 s/mm2) with and without (free breathing) respiratory gating.Images at b = 800 were analyzed by two radiologists. They performed qualitative analysis of fat-sat homogeneity and motion artifacts, rated from 0 to 4, and quantitative evaluation by studying signal to background (STB) of lymph nodes.

Results

Quality of fat suppression was significantly higher for DWIBS than for DWI both for free-breathing (score 3.48 ± 0.65 vs. 1.76 ± 0.96, p < 0.0001) and respiratory-gated scans (3.17 ± 0.77 vs. 1.72 ± 0.73, p = 0.0001). Similarly, artifacts were reduced with DWIBS (3.16 ± 0.47 vs. 1.76 ± 0.59, p < 0.0001; 3.0 ± 0.73 vs. 2.04 ± 0.53, p = 0.0001). Quantitative analysis showed higher STB with DWIBS (3.26 ± 1.83 vs. 0.98 ± 0.44, p < 0.0001; 3.56 ±, 2.09 vs. 0.92 ± 0.59, p < 0.0001). Gating did not improve image quality and STB on DWIBS (p > 0.05).

Conclusion

In thoracic MRI, ungated DWIBS sequence improves fat-sat homogeneity, reduces motion artifacts and increases STB of lymph nodes. Respiratory gating does not improve DWIBS image quality.  相似文献   

12.

Objective

To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).

Materials and Methods

Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.

Results

VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).

Conclusion

DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis.  相似文献   

13.

Objectives

Diffusion-weighted imaging with background body signal suppression (DWIBS) provides both qualitative and quantitative imaging of breast lesions and are usually performed before contrast material injection (CMI). This study aims to assess whether the administration of gadolinium significantly affects DWIBS imaging.

Methods

200 patients were prospectively evaluated by MRI with STIR, TSE-T2, pre-CMI DWIBS, contrast enhanced THRIVE-T1 and post-CMI DWIBS sequences. Pre and post-CMI DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤ 1.44 × 10- 3 mm2/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated for both sequences and represented by ROC analysis. Pre and post-CMI ADC values were compared by using the paired t test.

Results

In 150/200 (59%) patients, pre and post-CMI DWIBS indicated the presence of breast lesions, 53 (35%) with ADC values of > 1.44 × 10- 3 mm2/s and 97 (65%) with ADC ≤ 1.44 × 10- 3 mm2/s. Pre-CMI and post-DWIBS sequences obtained the same sensitivity, specificity, DA, PPV and NPV values of 97%, 83%, 89%, 79% and 98%. The mean ADC value of benign lesions was 1.831 ± 0.18 × 10- 3 mm2/s before and 1.828 ± 0.18 × 10- 3 mm2/s after CMI. The mean ADC value of the malignant lesions was 1.146 ± 0.16 × 10- 3 mm2/s before and 1.144 ± 0.16 × 10- 3 mm2/s after CMI. No significant difference was found between pre and post CMI ADC values (p > 0.05).

Conclusion

DWIBS imaging is not influenced by CMI. Breast MR protocol could be modified by placing DWIBS after dynamic contrast enhanced sequences in order to maximize patient cooperation.  相似文献   

14.

Purpose

This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation.

Materials and methods

Following surgical induction of MCAO for 90 min, agmatine was injected 5 min after beginning of reperfusion and again once daily for the next 3 post-operative days. The events during ischemia and reperfusion were investigated by T2-weighted images (T2WI), serial diffusion-weighted images (DWI), calculated apparent diffusion coefficient (ADC) maps and contrast-enhanced T1-weighted images (CE-T1WI) during 3 h–72 h in a 1.5 T Siemens MAGNETON Avanto Scanner. Lesion volumes were analyzed in a blinded and randomized manner. Triphenyltetrazolium chloride (TTC), Nissl, and Evans Blue stainings were performed at the corresponding sections.

Results

Increased lesion volumes derived from T2WI, DWI, ADC, CE-T1WI, and TTC all were noted at 3 h and peaked at 24 h–48 h after MCAO injury. TTC-derived infarct volumes were not significantly different from the T2WI, DWI-, and CE-T1WI-derived lesion volumes at the last imaging time (72 h) point except for significantly smaller ADC lesions in the MCAO model (P < 0.05). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived on T2WI, DWI or CE-T1WI than ADC (P < 0.05). At the last imaging time point, a significant increase in Evans Blue extravasation and a significant decrease in Nissl-positive cells numbers were noted in the vehicle-treated MCAO injured animals. The lesion volumes derived from T2WI, DWI, CE-T1WI, and Evans blue extravasation as well as the reduced numbers of Nissl-positive cells were all significantly attenuated in the agmatine-treated rats compared with the control ischemia rats (P < 0.05).

Conclusion

Our results suggest that agmatine has neuroprotective effects against brain edema on a reperfusion model after transient cerebral ischemia.  相似文献   

15.

Introduction

Diffusion tensor imaging (DTI) reveals white matter pathology in patients with multiple sclerosis (MS). A recent non-Gaussian diffusion imaging technique, q-space imaging (QSI), may provide several advantages over conventional MRI techniques in regard to in vivo evaluation of the disease process in patients with MS. The purpose of this study is to investigate the use of root mean square displacement (RMSD) derived from QSI data to characterize plaques, periplaque white matter (PWM), and normal-appearing white matter (NAWM) in patients with MS.

Methods

We generated apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps by using conventional DTI data from 21 MS patients; we generated RMSD maps by using QSI data from these patients. We used the Steel–Dwass test to compare the diffusion metrics of regions of interest in plaques, PWM, and NAWM.

Results

ADC differed (P < 0.05) between plaques and PWM and between plaques and NAWM. FA differed (P < 0.05) between plaques and NAWM. RMSD differed (P < 0.05) between plaques and PWM, plaques and NAWM, and PWM and NAWM.

Conclusion

RMSD values from QSI may reflect microstructural changes and white-matter damage in patients with MS with higher sensitivity than do conventional ADC and FA values.  相似文献   

16.

Purpose

To assess the value of gadoxetic acid-enhanced magnetic resonance imaging (MRI) for the pre-therapeutic detection of hepatocellular carcinoma (HCC) using receiver operating characteristic (ROC) analysis with the combination of computed tomography (CT) arterial portography and CT hepatic arteriography (CTAP/CTHA).

Materials and Methods

A total of 54 consecutive patients with 87 nodular HCCs were retrospectively analyzed. All HCC nodules were confirmed pathologically. Three blinded readers independently reviewed 432 hepatic segments, including 78 segments with 87 HCCs. Each reader read two sets of images: Set 1, CTAP/CTHA; Set 2, gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and diffusion-weighted imaging (DWI). The ROC method was used to analyze the results. The sensitivity, specificity, positive predictive value, negative predictive value and sensitivity according to tumor size were evaluated.

Results

For each reader, the area under the curve was significantly higher for Set 2 than for Set 1. The mean area under the curve was also significantly greater for Set 2 than for Set 1 (area under the curve, 0.98 vs. 0.93; P = .0009). The sensitivity was significantly higher for Set 2 than for Set 1 for all three readers (P = .012, .013 and .039, respectively). The difference in the specificity, positive predictive values and negative predictive values of the two modalities for each reader was not significant (P > .05).

Conclusion

Gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and DWI is recommended for the pre-therapeutic evaluation of patients with HCC.  相似文献   

17.

Purpose

The purpose of the study was to evaluate the conspicuity of bone metastases on each of the numerous sequences produced by fast Dixon-based multisequence whole-body (WB) magnetic resonance imaging (MRI) scanning in order to determine the most clinically useful sequences overall and per anatomic region.

Materials and Methods

Twenty-seven breast cancer patients with bone metastases were prospectively studied with fast Dixon-based WB MRI including head/neck, chest, abdominal, pelvic, thigh, calf/feet and either cervical, thoracic and lumbar or cervical/thoracic and thoracic/lumbar regions. Sequences included coronal T2, axial T1 without and with intravenous gadolinium (+ C), sagittal T1 spine + C, each associated fat-only (FO) and fat-saturated (FS) sequence, axial diffusion-weighted imaging (DWI) and short tau inversion recovery (STIR). Blinded reviewers evaluated lesion conspicuity, a surrogate of clinical utility, on a five-point scale per anatomic region. Sequences were compared using analysis of variance, differences were detected with Tukey's honestly significant difference test, and the four sequences with highest mean conspicuity were compared to the remainder overall and per anatomic region.

Results

Overall, a significant lesion conspicuity difference was found (P < .0001), and lesion conspicuity was significantly higher on FS T1 + C, FO T1 + C, T1 + C sagittal and FS T1 + C axial sequences (P < .0001). Per-region results were the same in the head/neck. Other sequences overlapped with these and included the following: chest/abdomen — FO T2, DWI; pelvis — DWI, FO T2; thigh — FS T2, FO T2, FO T1 + C; calf/feet — FS T2, DWI, FO T2, STIR.

Conclusion

Overall, bone lesions were most conspicuous on FS T1 + C sagittal, FO T1 + C sagittal, T1 + C sagittal and FS T1 + C axial fast Dixon WB MRI sequences.  相似文献   

18.

Purpose

The objective of this paper was to investigate the value of apparent diffusion coefficients (ADCs) for differential diagnosis among solid pancreatic masses using respiratory triggered diffusion-weighted MR imaging with inversion-recovery fat-suppression technique (RT-IR-DWI) at 3.0 T.

Materials and Methods

20 normal volunteers and 72 patients (Pancreatic ductal adenocarcinoma [PDCA, n = 30], mass-forming pancreatitis [MFP, n = 15], solid pseudopapillary neoplasm [SPN, n = 12], and pancreatic neuroendocrine tumor[PNET, n = 15]) underwent RT-IR-DWI (b values: 0 and 600 s/mm2) at 3.0 T. Results were correlated with histopathologic data and follow-up imaging. ADC values among different types of pancreatic tissue were statistically analyzed and compared.

Results

Statistical difference was noticed in ADC values among normal pancreas, MFP, PDCA, SPN and PNET by ANOVA (p < .001). Normal pancreas had the highest ADC value, then followed by PNET, PDCA, MFP and SPN. There was noticeable statistical difference in ADC values among PDCA, MFP and normal pancreas by Least Significant Difference (LSD) (p < .001). ADC of SPN was statistically lower than that of PNET (p = 0.1800 × 10− 4), PDCA (p = 0.0300 × 10− 4) and normal pancreas (p = 0.0007 × 10− 4). ADC of PNET was statistically lower than that of normal pancreas (p = 0.0360) and higher than that of MFP (p = 9.3000 × 10− 4).

Conclusions

ADC measurements using RT-IR-DWI at 3.0 T may aid to disclose the histopathological pattern of normal pancreas and solid pancreatic masses, which may be helpful in characterizing solid pancreatic lesions.  相似文献   

19.

Purpose

To assess the feasibility of full diffusional kurtosis tensor imaging (DKI) in prostate MRI in clinical routine. Histopathological correlation was achieved by targeted biopsy.

Materials and Methods

Thirty-one men were prospectively included in the study. Twenty-one were referred to our hospital with increased prostate specific antigen (PSA) values (> 4 ng/ml) and suspicion of prostate cancer. The other 10 men were volunteers without any history of prostate disease. DKI applying diffusion gradients in 20 different spatial directions with four b-values (0, 300, 600, 1000 s/mm2) was performed additionally to standard functional prostate MRI. Region of interest (ROI)-based measurements were performed in all histopathologically verified lesions of every patient, as well as in the peripheral zone, and the central gland of each volunteer.

Results

DKI showed a substantially better fit to the diffusion-weighted signal than the monoexponential apparent diffusion coefficient (ADC). Altogether, 29 lesions were biopsied in 14 different patients with the following results: Gleason score 3 + 3 = 6 (n = 1), 3 + 4 = 7 (n = 7), 4 + 3 = 7 (n = 6), 4 + 4 = 8 (n = 1), and 4 + 5 = 9 (n = 2), and prostatitis (n = 12). Values of axial (Kax) and mean kurtosis (Kmean) were significantly different in the tumor (Kax 1.78 ± 0.39, Kmean 1.84 ± 0.43) compared with the normal peripheral zone (Kax 1.09 ± 0.12, Kmean 1.16 ± 0.13; p < 0.001) or the central gland (Kax 1.40 ± 0.12, Kmean 1.44 ± 0.17; p = 0.01 respectively). There was a minor correlation between axial kurtosis (r = 0.19) and the Gleason score.

Conclusion

Full DKI is feasible to utilize in a routine clinical setting. Although there is some overlap some DKI parameters can significantly distinguish prostate cancer from the central gland or the normal peripheral zone. Nevertheless, the additional value of DKI compared with conventional monoexponential ADC calculation remains questionable and requires further research.  相似文献   

20.

Objectives

We conducted a pilot study to identify whether MRI parameters are sensitive to hormone-induced changes in the breast during the natural menstrual cycle and whether changes could also be observed during an oral contraceptive (OC) cycle.

Materials and Methods

The New York University Langone Medical Center Institutional Review Board approved this HIPAA-compliant prospective study. All participants provided written informed consent. Participants were aged 24-31 years.We measured several non-contrast breast MRI parameters during each week of a single menstrual cycle (among 9 women) and OC cycle (among 8 women). Hormones were measured to confirm ovulation and classify menstrual cycle phase among naturally cycling women and to monitor OC compliance among OC users. We investigated how the non-contrast MRI parameters of breast fibroglandular tissue (FGT), apparent diffusion coefficient (ADC), magnetization transfer ratio (MTR), and transverse relaxation time (T2) varied over the natural and the OC cycles.

Results

We observed significant increases in MRI FGT% and ADC in FGT, and longer T2 in FGT in the luteal vs. follicular phase of the menstrual cycle. We did not observe any consistent pattern of change for any of the MRI parameters among women using OCs.

Conclusions

MRI is sensitive to hormone-induced breast tissue changes during the menstrual cycle. Larger studies are needed to assess whether MRI is also sensitive to the effects of exogenous hormones, such as various OC formulations, on the breast tissue of young premenopausal women.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号