首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images.

Methods

A 3 T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test.

Results

Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P = 0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P = 0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P = 0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes.

Conclusions

Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization.  相似文献   

2.

Objectives

To investigate and optimize diffusion-weighted imaging (DWI) acquisitions for pancreatic cancer at 3.0 T.

Methods

Forty-five patients with pancreatic cancer were examined by four DWI acquisitions with b values = 0 and 600 s/mm2 at 3.0 T, including breath-holding DWI (BH-DWI), respiratory-triggered DWI (TRIG-DWI), respiratory-triggered DWI with inversion–recovery technique (TRIGIR-DWI), and free-breathing DWI with inversion–recovery technique (FBIR-DWI). Artifacts, contrast ratio (CR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of pancreatic cancer were statistically compared among DWI acquisitions.

Results

TRIGIR-DWI displayed the lowest artifacts and highest CR compared to other DWI acquisitions. CNRs of pancreatic cancer in TRIG-DWI and TRIGIR-DWI were statistically higher than that in FBIR-DWI and BH-DWI. Different ADCs between pancreatic cancer and noncancerous pancreatic tissues were noticed by a paired-samples T test in TRIG-DWI (p = 0.017), TRIGIR-DWI (p = 0.00001) and FBIR-DWI (p = 0.000041).

Conclusions

TRIGIR-DWI may be the optimal acquisition of DWI for pancreatic cancer at 3.0 T.  相似文献   

3.

Purpose

This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation.

Materials and methods

Following surgical induction of MCAO for 90 min, agmatine was injected 5 min after beginning of reperfusion and again once daily for the next 3 post-operative days. The events during ischemia and reperfusion were investigated by T2-weighted images (T2WI), serial diffusion-weighted images (DWI), calculated apparent diffusion coefficient (ADC) maps and contrast-enhanced T1-weighted images (CE-T1WI) during 3 h–72 h in a 1.5 T Siemens MAGNETON Avanto Scanner. Lesion volumes were analyzed in a blinded and randomized manner. Triphenyltetrazolium chloride (TTC), Nissl, and Evans Blue stainings were performed at the corresponding sections.

Results

Increased lesion volumes derived from T2WI, DWI, ADC, CE-T1WI, and TTC all were noted at 3 h and peaked at 24 h–48 h after MCAO injury. TTC-derived infarct volumes were not significantly different from the T2WI, DWI-, and CE-T1WI-derived lesion volumes at the last imaging time (72 h) point except for significantly smaller ADC lesions in the MCAO model (P < 0.05). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived on T2WI, DWI or CE-T1WI than ADC (P < 0.05). At the last imaging time point, a significant increase in Evans Blue extravasation and a significant decrease in Nissl-positive cells numbers were noted in the vehicle-treated MCAO injured animals. The lesion volumes derived from T2WI, DWI, CE-T1WI, and Evans blue extravasation as well as the reduced numbers of Nissl-positive cells were all significantly attenuated in the agmatine-treated rats compared with the control ischemia rats (P < 0.05).

Conclusion

Our results suggest that agmatine has neuroprotective effects against brain edema on a reperfusion model after transient cerebral ischemia.  相似文献   

4.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

5.

Purpose

The purpose of the study was to evaluate the conspicuity of bone metastases on each of the numerous sequences produced by fast Dixon-based multisequence whole-body (WB) magnetic resonance imaging (MRI) scanning in order to determine the most clinically useful sequences overall and per anatomic region.

Materials and Methods

Twenty-seven breast cancer patients with bone metastases were prospectively studied with fast Dixon-based WB MRI including head/neck, chest, abdominal, pelvic, thigh, calf/feet and either cervical, thoracic and lumbar or cervical/thoracic and thoracic/lumbar regions. Sequences included coronal T2, axial T1 without and with intravenous gadolinium (+ C), sagittal T1 spine + C, each associated fat-only (FO) and fat-saturated (FS) sequence, axial diffusion-weighted imaging (DWI) and short tau inversion recovery (STIR). Blinded reviewers evaluated lesion conspicuity, a surrogate of clinical utility, on a five-point scale per anatomic region. Sequences were compared using analysis of variance, differences were detected with Tukey's honestly significant difference test, and the four sequences with highest mean conspicuity were compared to the remainder overall and per anatomic region.

Results

Overall, a significant lesion conspicuity difference was found (P < .0001), and lesion conspicuity was significantly higher on FS T1 + C, FO T1 + C, T1 + C sagittal and FS T1 + C axial sequences (P < .0001). Per-region results were the same in the head/neck. Other sequences overlapped with these and included the following: chest/abdomen — FO T2, DWI; pelvis — DWI, FO T2; thigh — FS T2, FO T2, FO T1 + C; calf/feet — FS T2, DWI, FO T2, STIR.

Conclusion

Overall, bone lesions were most conspicuous on FS T1 + C sagittal, FO T1 + C sagittal, T1 + C sagittal and FS T1 + C axial fast Dixon WB MRI sequences.  相似文献   

6.

Objective

To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).

Materials and Methods

Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.

Results

VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).

Conclusion

DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis.  相似文献   

7.

Purpose

To investigate diffusion-weighted (DWI) and dynamic contrast-enhanced MR imaging (DCE-MRI) as early response predictors in cervical cancer patients who received concurrent chemoradiotherapy (CCRT).

Materials and methods

Sixteen patients with cervical cancer underwent DWI and DCE-MRI before CCRT (preTx), at 1 week (postT1) and 4 weeks (postT2) after initiating treatment, and 1 month after the end of treatment (postT3). At each point, apparent diffusion coefficient (ADC) and DCE-MRI parameters were measured in tumors and gluteus muscles (GM). Tumor response was correlated with imaging parameters or changes in imaging parameters at each point.

Results

At each point, ADC, Ktrans and Ve in tumors showed significant changes (P < 0.05), as compared with those of GM (P > 0.05). PostT1 tumor ADCs showed a significant correlation with tumor size response at postT2 (P = 0.041), and changes in tumor ADCs at postT1 had a significant correlation with tumor size (P = 0.04) and volume response (P = 0.003) at postT2. In tumors, preTx Ktrans and Ve showed significant correlations with tumor size at postT3 (P = 0.011) and tumor size response at postT2 (P = 0.019), respectively.

Conclusion

DWI and DCE-MRI, as early biomarkers, have the potential to evaluate therapeutic responses to CCRT in cervical cancers.  相似文献   

8.

Purpose

To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease.

Materials and methods

We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, and 34 benign lesions (≤ 2.0 cm), and 22 patients with cirrhosis but no focal liver lesion who underwent 3.0 T liver MRI. Noncontrast MRI set (T1- and T2-weighted images and DWI) and standard MRI set (gadoxetic acid-enhanced and noncontrast MRI) were analyzed independently by three observers to detect liver malignancies using receiver operating characteristic analysis.

Results

The Az value of the noncontrast MRI (mean, 0.906) was not inferior to that of the combined MRI (mean, 0.924) for detecting malignancies by all observers (P > 0.05). For each observer, no significant difference was found in the sensitivity and specificity between the two MRI sets for detecting liver malignancies and distinguishing them from benign lesions (P > 0.05), whereas negative predictive value was higher with the combined MRI than with the noncontrast MRI (P = 0.0001). When using pooled data, the sensitivity of the combined MRI (mean 94.8%) was higher than that of the noncontrast MRI (mean, 91.7%) (P = 0.001), whereas specificity was equivalent (78.6% vs 77.5%).

Conclusion

Noncontrast MRI including DWI showed reasonable performance compared to the combined gadoxetic acid-enhanced and noncontrast MRI set for detecting HCC and cholangiocarcinoma and differentiating them from benign lesions in patients with chronic liver disease.  相似文献   

9.

Purpose

To present diffusion and perfusion magnetic resonance imaging (MRI) characteristics of focal nodular hyperplasia (FNH) of the liver.

Materials and Methods

Thirty-five patients with 52 FNHs (21 were pathologically-confirmed) underwent MRI at 1.5-T device. MR diffusion [diffusion-weighted imaging (DWI)] was performed using a free-breathing single-shot, spin-echo, echo-planar sequence with b gradient factor value of 500 s/mm². MR perfusion [perfusion-weighted imaging (PWI)] consisted of a 3D free-breathing LAVA sequence repeated up to 5 minutes after injection of 7 mL Gd-BOPTA (MultiHance, Bracco, Italy) and 20 mL saline flush at a flow rate of 4 mL/s. Apparent diffusion coefficient (ADC) and time-signal intensity curve (TSIC) were obtained for both normal liver and each FNH by two reviewers in conference; maximum enhancement (ME) percentage, time to peak enhancement (TTP), and maximal slope (MS) were also calculated.

Results

On DWI mean ADC value was 1.624×10− 3 mm2/s for normal liver and 1.629×10− 3 mm2/s for FNH. ADC value for each FNH and the normal liver was not statistically different (P= .936). On PWI, TSIC-Type 1 (quick and marked enhancement and quick decay followed by slowly decaying) was observed in all 52 FNHs, and TSIC-Type 2 (fast enhancement followed by slowly decaying plateau) in all normal livers. The mean ME, TTP and MS values were significantly different for FNH and normal liver (P= .005).

Conclusion

FNHs of the liver showed typical diffusion and perfusion MRI characteristics in all cases. On the ADC map, we could get similar value between the FNHs and the background parenchyma. On the perfusion imaging, FNHs showed a different pattern distinguished from the background liver.  相似文献   

10.

Purpose

To compare diffusion weighted imaging with background suppression (DWIBS) sequence with classic spectral diffusion sequence (DWI) with and without respiratory gating in mediastinal lymph node analysis at 3 T.

Materials and methods

26 patients scheduled for mediastinoscopic lymph node analysis, prospectively undergone a thoracic 3 T MRI with DWIBS (FatSat = STIR; TR/TE = 6674.1/44.7 ms; IR = 260 ms) and DWI sequences (FatSat = SPIR; TR/TE = 1291/59.6 ms) (b = 0-400-800 s/mm2) with and without (free breathing) respiratory gating.Images at b = 800 were analyzed by two radiologists. They performed qualitative analysis of fat-sat homogeneity and motion artifacts, rated from 0 to 4, and quantitative evaluation by studying signal to background (STB) of lymph nodes.

Results

Quality of fat suppression was significantly higher for DWIBS than for DWI both for free-breathing (score 3.48 ± 0.65 vs. 1.76 ± 0.96, p < 0.0001) and respiratory-gated scans (3.17 ± 0.77 vs. 1.72 ± 0.73, p = 0.0001). Similarly, artifacts were reduced with DWIBS (3.16 ± 0.47 vs. 1.76 ± 0.59, p < 0.0001; 3.0 ± 0.73 vs. 2.04 ± 0.53, p = 0.0001). Quantitative analysis showed higher STB with DWIBS (3.26 ± 1.83 vs. 0.98 ± 0.44, p < 0.0001; 3.56 ±, 2.09 vs. 0.92 ± 0.59, p < 0.0001). Gating did not improve image quality and STB on DWIBS (p > 0.05).

Conclusion

In thoracic MRI, ungated DWIBS sequence improves fat-sat homogeneity, reduces motion artifacts and increases STB of lymph nodes. Respiratory gating does not improve DWIBS image quality.  相似文献   

11.

Purpose

The purpose of the study was to determine significant imaging features to differentiate between infiltrative hepatocellular carcinoma (HCC) and confluent fibrosis (CF) in liver cirrhosis using Gd-EOB-DTPA-enhanced 3-T magnetic resonance imaging.

Material and methods

Nineteen infiltrative HCCs and eight CFs were included. We evaluated the difference in imaging findings and apparent diffusion coefficient (ADC) between the two entities. We compared T2-weighted image (WI) and hepatobiliary phase (HBP) in terms of the clarity of the lesion outer margin.

Results

Seventeen infiltrative HCCs showed lobulated margin, while focal CFs showed either straight (n = 3) or irregular margins (n = 5) (P = .001). All infiltrative HCCs had intact or bulging contours, and all focal CFs showed capsular retraction (P = .001). Fourteen infiltrative HCCs and two focal CFs showed arterial enhancement (P = .035). The ADC of infiltrative HCCs was significantly lower than that of CFs (P = .001). Satellite nodules were noted in 10 infiltrative HCCs. In terms of outer margin clarity, infiltrative HCCs showed a more distinct margin on HBP than on T2-WI (P = .005), while these two sequences were not significantly different in focal CFs (P = 1.000).

Conclusion

HBP improved the imaging characteristics of infiltrative HCC, allowing it to be distinguished from focal CF. Infiltrative HCC showed lower ADC values than focal CF. Lobular configuration, contour bulging, enhancement pattern, associated satellite nodules and portal vein thrombosis were still found to be highly suggestive MR findings for infiltrative HCC.  相似文献   

12.

Purpose

This retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.

Materials and Methods

Twenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.

Results

The mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.

Conclusion

We found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs.  相似文献   

13.

Purpose

To investigate whether image quality can be improved using liquid perfluorocarbon pads (Sat Pad) and clarify the optimal fat-suppression method among chemical shift selective (CHESS), water excitation (WEX), and short TI inversion recovery (STIR) methods in diffusion-weighted imaging (DWI) of the head and neck using 3-T magnetic resonance imaging. Correlations between results of visual inspection and quantitative analysis were also examined.

Material and Methods

This study was approved by our Institutional Review Board and informed consent was waived. DWI was performed on 25 subjects with/without Sat Pad and using three fat-suppression methods (6 patterns). Image quality was evaluated visually (4-point scales and lesion-depiction capability) and by quantitative analysis (signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Two-way repeated-measures analysis of variance (ANOVA) was used to detect significant differences in scores of visual evaluation, SNR, and CNR.

Results

Mean visual evaluation scores were significantly higher with Sat Pad using STIR than without Sat Pad for all fat-suppression methods (P < 0.05). DWI with Sat Pad using STIR tended to be useful for depicting lesions. DWI using STIR showed reduced W-SNR (W: whole area of depicted structure) and CNR (between semispinalis capitis muscle and subcutaneous fat) due to fewer artifacts and uniform fat suppression.

Conclusion

Combining Sat Pad with STIR provides good image quality for visual inspections. When numerous artifacts are present and fat suppression is insufficient, higher SNR and CNR do not always provide good diagnostic image quality.  相似文献   

14.

Purposes

To evaluate the diagnostic value of diffusion-weighted MRI (DWI) and combination of conventional MRI and DWI to predict metastatic axillary lymph nodes in breast cancer.

Materials and methods

Two hundred fifty-two breast cancer patients with 253 axillae were included. The morphological parameters on axial T2-weighted images without fat saturation and apparent diffusion coefficient (ADC) values were retrospectively analyzed. An independent t-test/chi-square test and receiver operating characteristics (ROC) curve analysis were used.

Results

On conventional MRI, short and long axis length, maximal cortical thickness, relative T2 value, loss of fatty hilum (p < 0.001 for each), and eccentric cortical thickening (p < 0.003) were statistically significantly different between the metastatic and nonmetastatic groups. The short axis to long axis ratio was not a statistically significant parameter. The ADC value was significantly different between the 2 groups, with an AUC that was higher than that of conventional MR parameters (AUC, 0.815; threshold, ≤ 0.986 × 10–3 mm2/sec; sensitivity, 75.8%; specificity, 83.9%). Using the adopted thresholds for each parameter, a total number of findings suggesting malignancy of 4 or higher was determined as the threshold, with high specificity (90.1%).

Conclusion

Using conventional MRI and DWI, we can evaluate the axilla in breast cancer with high specificity.  相似文献   

15.
Ultrasound Nakagami parametric imaging is a useful tool for tissue characterization. Previous literature has suggested using a square with side lengths corresponding to 3 times the transducer pulse length as the minimum window for constructing the Nakagami image. This criterion does not produce sufficiently smooth images for the Nakagami image to characterize homogeneous tissues. To improve image smoothness, we proposed window-modulated compounding (WMC) Nakagami imaging based on summing and averaging the Nakagami images formed using sliding windows with varying window side lengths from 1 to N times the transducer pulse length in 1 pulse length step. Simulations (the number densities of scatterers: 2–16 scatterers/mm2) and experiments on fully developed speckle phantoms (the scatterer diameters: 20–106 μm) were conducted to suggest an appropriate number of frames N and to evaluate the image smoothness and resolution by analyzing the full width at half maximum (FWHM) of the parameter distribution and the widths of the image autocorrelation function (ACF), respectively. In vivo ultrasound measurements on rat livers without and with cirrhosis were performed to validate the practical performance of the WMC Nakagami image in tissue characterization. The simulation results showed that using a range of N from 7 to 10 as the number of frames for image compounding reduces the estimation error to less than 5%. Based on this criterion, the Nakagami parameter obtained from the WMC Nakagami image increased from 0.45 to 0.95 after increasing the number densities of scatterers from 2 to 16 scatterers/mm2. The FWHM of the parameter distribution (bins = 40) was 13.5 ± 1.4 for the Nakagami image and 9.1 ± 1.43 for the WMC Nakagami image, respectively (p-value < .05). The widths of the ACF for the Nakagami and WMC Nakagami images were 454 ± 5.36 and 458 ± 4.33, respectively (p-value > .05). In the phantom experiments, we also found that the FWHM of the parameter distribution for the WMC Nakagami image was smaller than that of the conventional Nakagami image (p-value < .05), and there was no significant difference of the ACF width between the Nakagami and WMC Nakagami images (p-value > .05). In the animal experiments, the Nakagami parameters obtained from the WMC Nakagami image for normal and cirrhotic rat livers were 0.62 ± 0.08 and 0.92 ± 0.07, respectively (p-value < .05). The results demonstrated that the WMC technique significantly improved the image smoothness of Nakagami imaging without resolution degradation, giving Nakagami model-based imaging the ability to visualize scatterer properties with enhanced image quality.  相似文献   

16.
Magnetic resonance spectroscopy (MRS) has long been considered the golden standard for non-invasive measurement of tissue fat content. With improved techniques for fat/water separation, imaging has become an alternative to MRS for fat quantification. Several imaging models have been proposed, but their performance relative to MRS at very low fat contents is yet not fully established. In this work, imaging and spectroscopy were compared at 1.5 T and 3 T in phantoms with 0-3% fat fraction (FF). We propose a multispectral model with individual a priori R2 relaxation rates for water and fat, and a common unknown R2′ relaxation. Magnitude and complex image reconstructions were also compared. Best accuracy was obtained with the imaging method at 1.5 T. At 3 T, the FFs were underestimated due to larger fat-water phase shifts. Agreement between measured and true FF was excellent for the imaging method at 1.5 T (imaging: FFmeas= 0.98 FFtrue− 0.01%, spectroscopy: FFmeas= 0.77 FFtrue+ 0.08%), and fair at 3 T (imaging: FFmeas= 0.91 FFtrue− 0.19%, spectroscopy: FFmeas= 0.79 FFtrue+ 0.02%). The imaging method was able to quantify FFs down to approx. 0.5%. We conclude that the suggested imaging model is capable of fat quantification with accuracy and precision similar to or better than spectroscopy and offers an improvement vs. a model with a common R2* relaxation only.  相似文献   

17.

Purpose

The purpose of our study was to compare diffusion-weighted MR imaging (DWI) with conventional dynamic MRI in terms of the assessment of small intrahepatic metastases from hepatocellular carcinoma (HCC).

Materials and Methods

In 24 patients with multifocal, small (≤2 cm) intrahepatic metastatic foci of advanced HCC, a total of 134 lesions (≤1 cm, n=81; >1 cm, n=53) were subjected to a comparative analysis of hepatic MRI including static and gadopentetate dimeglumine-enhanced dynamic imaging, and DWI using a single-shot spin-echo echo-planar MRI (b values=50, 400 and 800 s/mm2), by two independent reviewers.

Results

A larger number of the lesions were detected and diagnosed as intrahepatic metastases on DWI [Reviewer 1, 121 (90%); Reviewer 2, 117 (87%)] than on dynamic imaging [Reviewer 1, 107 (80%); Reviewer 2, 105 (78%)] (P<.05). For the 81 smaller lesions (≤1 cm), DWI was able to detect more lesions than dynamic imaging [Reviewer 1, 68 (84%) vs. 56 (69%), P=.008; Reviewer 2, 65 (80%) vs. 55 (68%), P=.031], but there was no statistically significant difference between the two image sets for larger (>1 cm) lesions.

Conclusion

Due to its higher detection rate of subcentimeter lesions, DWI could be considered complementary to dynamic MRI in the diagnosis of intrahepatic metastases of HCCs.  相似文献   

18.

Background and Purpose

Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 3T in patients with spinal prostheses.

Methods

Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used.

Results

Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected.

Conclusion

SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and peri-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis.  相似文献   

19.

Purpose

To assess the value of gadoxetic acid-enhanced magnetic resonance imaging (MRI) for the pre-therapeutic detection of hepatocellular carcinoma (HCC) using receiver operating characteristic (ROC) analysis with the combination of computed tomography (CT) arterial portography and CT hepatic arteriography (CTAP/CTHA).

Materials and Methods

A total of 54 consecutive patients with 87 nodular HCCs were retrospectively analyzed. All HCC nodules were confirmed pathologically. Three blinded readers independently reviewed 432 hepatic segments, including 78 segments with 87 HCCs. Each reader read two sets of images: Set 1, CTAP/CTHA; Set 2, gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and diffusion-weighted imaging (DWI). The ROC method was used to analyze the results. The sensitivity, specificity, positive predictive value, negative predictive value and sensitivity according to tumor size were evaluated.

Results

For each reader, the area under the curve was significantly higher for Set 2 than for Set 1. The mean area under the curve was also significantly greater for Set 2 than for Set 1 (area under the curve, 0.98 vs. 0.93; P = .0009). The sensitivity was significantly higher for Set 2 than for Set 1 for all three readers (P = .012, .013 and .039, respectively). The difference in the specificity, positive predictive values and negative predictive values of the two modalities for each reader was not significant (P > .05).

Conclusion

Gadoxetic acid-enhanced MRI including a gradient dual-echo sequence and DWI is recommended for the pre-therapeutic evaluation of patients with HCC.  相似文献   

20.

Purpose

To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.

Materials and Methods

We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.

Results

In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.

Conclusion

As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号