首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A salicylate‐selective electrode based on calix[4]arene derivative was developed and its response characteristics were investigated. The optimum membrane composition was 1 % ionophore, 30 % PVC, 69 % DOS. The electrode exhibited a Nernstian slope of 58.8±0.5 mV/pSal in the range of 1.0×10?5–1.0×10?1 M with a detection limit of 4.3×10?6 M at pH 4.0, 20±1 °C. The potentiometric response of the electrode in the presence of different anions was investigated by the separate solution method. The lifetime was found at least 4 months, and its response time was 5–10 s. It was successfully used for the potentiometric determination of salicylate in pharmaceutical preparations.  相似文献   

2.
A highly selective PVC‐membrane electrode based on 2,6‐diphenylpyrylium fluoroborate is presented. The electrode reveals a Nernstian potentiometric response for sulfate ion over a wide concentration range (5.0 × 10?6‐1.0 × 10?1 M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for sulfate over a wide variety of common organic and inorganic anions and could be used over a wide pH range (2.5–9.5). The detection limit of the sensor is 3.0 × 10?6 M. It was successfully applied to the direct determination of salbutamol, paramomycin tablets, and as an indicator electrode for potentiometric titration of sulfate ions with barium ions.  相似文献   

3.
A new chromium(III) PVC membrane sensor incorporating ptertiary‐butyl calix[4]arene as ionophore, potassium tetrakis as additive and dibutyl phthalate (DBP) as plasticizer was constructed. The electrode exhibited an excellent potentiometric response over a wide concentration range of 1.0×10?7–1.0×10?1 M with a Nernstian slope of 20±0.5 mV per decade. The detection limit was 5.0×10?8 M. The electrode showed a better performance over a pH range of 3.0–8.0, and had a short response time of about <15 s.The electrode was successfully applied to potentiometric titration of Cr (III) with EDTA and for direct determination of chromium(III) in waste water.  相似文献   

4.
《Electroanalysis》2004,16(11):910-914
A novel bromide PVC‐based membrane sensor, based on iron(III)‐salen (IS) as an electroactive material, is successfully developed. The sensor possesses the advantages of low detection limit (6.0×10?6), wide working concentration range (7.0×10?6–1.0×10?1 M), Nernstian behavior (slope of 59.0±0.5 mV per decade), low response time (<15 s), wide working pH range (3–9), and specially, high bromide selectivity over a wide variety of organic and inorganic anions, specially iodide, chloride, and hydroxide ions. The electrode was used in the direct potentiometric determination of hyoscine butylbromide, and as an indicator electrode in potentiometric titration of bromide ions with silver ions.  相似文献   

5.
《Electroanalysis》2003,15(19):1561-1565
A highly selective membrane electrode for the determination of ultratrace amounts of lead was prepared. The PVC membrane electrode based on 2‐(2‐ethanoloxymethyl)‐1‐hydroxy‐9,10‐anthraquinone (AQ), directly coated on graphite, exhibits a good Nernstian response for Pb(II) ions over a very wide concentration range (1.0×10?7–1.0×10?2 M) with a limit of detection of 8.0×10?8 M. It has a fast response time of ca. 10 s and can be used over a period 2 months with good reproducibility (SD=±0.2 mV). The electrode revealed a very good selectivity respect to common alkali, alkaline earth, transition and heavy metal ions and could be used in the pH range of 3.5–6.8. It was used as an indicator electrode in potentiometric titration of lead ions with chromate and oxalate, and in indirect determination of lead in spring water samples.  相似文献   

6.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions.  相似文献   

7.
《Electroanalysis》2004,16(12):1009-1013
A novel ion‐selective polymeric membrane sensor based on pyrylium‐4,4‐(1,4‐phenylen) bis[2,6‐bis(2‐naphthyl)]‐bis[tetrafluoroborate] (PBGNB) as an excellent sensing material is successfully developed. The electrode possesses the advantages of a very low detection limit (5.0×10?8 M), a wide working concentration range (1.0×10?8?1.0×10?1 M) and specially, a high sulfate selectivity over most common organic and inorganic anions. The sensor displays Nernstian behavior (slope of 29.5±0.5 mV per decade) in a wide pH range (3.0–8.5). It shows a short response time in the whole concentration range (ca. 10 s). The electrode was used as an indicator electrode in the potentiometric titration of sulfate ions with barium ions. The proposed sensor was successfully applied to the direct determination of salbutamol sulfate and paromomycin sulfate.  相似文献   

8.
《Analytical letters》2012,45(13):2611-2629
ABSTRACT

New potentiometric membranesensorsresponsive to Pb(II) have been developed. The membrane sensors are based on three different 9, 10-anthraquinone derivatives. The electrode based on 1, 4-bis (prop-21-enyloxy)-9, 10-anthraquinone exhibits a good Nernstian response for Pb(II) ions over a wide concentration range (2.5×10?6 - 1.0×10?2 M) with a slope of 29.8 mV decade?1. Detection limit is 1.5×10?6 M. The response time of the sensor is 15s and the useful working pH range is 4.7-6.8. The membrane can be used for more than 4 months without any considerable divergence in potentials. The electrodes revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of lead ions (with sulfate and oxalate ions), and for the determination of lead in waste waters.  相似文献   

9.
《Electroanalysis》2004,16(16):1330-1335
A poly(vinyl chloride) membrane sensor based on oxalic acid bis (cyclohexylidene hydrazide) as membrane carrier was prepared and investigated as a Cr(III)‐selective electrode. The electrode reveals a Nernstian behavior (slope 19.8±0.4 mV decade?1) over a wide Cr(III) ion concentration range 1.0×10?7–1.0×10?2 mol dm?3 with a very low limit of detection (i.e., down to 6.3×10?8 mol dm?3). The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 1.7–6.5. The electrode possesses advantage of very fast response, relatively long lifetime and especially good selectivity to wide variety of other cations. The sensor was used as an indicator electrode, in the potentiometric titration of chromium ion and in the determination of Cr(III) in waste water and alloy samples.  相似文献   

10.
A novel potentiometric sensor based on screen‐printed carbon electrode covered with electropolymerized polyaniline (PANI) and unsubstituted pillar[5]arene as ionophore has been developed and tested in potentiometric measurements of pH and metal ions. The introduction of pillar[5]arene improved the reversibility of the pH response in the range from 2.0 to 9.0 with the slope of 45 mV/pH. Among metal cations, the response to Fe3+ and Ag+ ions was referred to PANI redox conversion whereas the signal toward Cu2+ in the range from 1.0×10?6 to 1.0×10?2 M (limit of detection (LOD) 3.0×10?7 M) to specific interaction with the macrocycle.  相似文献   

11.
《Electroanalysis》2005,17(20):1828-1834
A recently synthesized azao‐containing Schiff's base N,N′‐adipylbis(5‐phenylazo salicylaldehyde hydrazone) was used as a suitable neutral ion carrier in construction of a highly selective La3+‐PVC membrane electrode. The electrode exhibits a Nernstian response with a slope of 19.4 mV decade?1 over a wide concentration range (1.0×10?6–1.0×10?2 M) and a limit of detection of 4.0×10?7 M (0.05 ppm). The electrode possesses a fast response time of ca. 10 s and can be used for at least 3 months without observing any deviation. The proposed electrode revealed excellent selectivity for La3+ over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–8.0. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of La3+ ions with EDTA and in determination of F? ion in some pharmaceutical preparations.  相似文献   

12.
《Analytical letters》2012,45(11):2169-2181
ABSTRACT

A new PVC membrane for zinc ions based on DBDA15C4 as membrane carrier was prepared. The electrode shows a linear stable response over a wide concentration range (5.0 × 10?5-1.0 × 10?1 M) with a slope of 22 mV/decade and a limit of detection of 3.0 × 10?5 M (2.0 μg/ml). It has a very short response time of less than 5 s and can be use for at least 11 months without any divergence in potential. The zinc ion-selective electrode exhibited very good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions and could be used in a pH range 1.5-7.0. It was successfully applied for the direct determination of zinc in a pharmaceutical sample and, as an indicator electrode, in potentiometric titration of Zn2+ ions.  相似文献   

13.
A PVC membrane electrode for copper(II) ion based on a recently synthesized Schiff base as a suitable ion carrier was constructed. The electrode exhibits a Nernstian slope of 28.3 ± 0.6 mV per decade of Cu2+ over a wide concentration range of 7.0 × 10?6‐2.6 × 10?2 M with a detection limit of 5.0 × 10?6M in the pH range of 4.2–5.8. The response time is about 10s and it can be used for at least 1 month without any considerable divergence in potential. It was successfully applied as an indicator electrode in the potentiometric titration of copper ions.  相似文献   

14.
《Electroanalysis》2002,14(23):1621-1628
Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near‐Nernestian slope for iodide was observed over a wide linear range of five decades of concentration (5×10?6?1×10?1 M). The electrode has a fast response time, and micro‐molar detection limit (ca. 1×10?6 M iodide) and could be used over a wide pH range of 3.0–8.0. Application of the electrode to the potentiometric titration of iodide ion with silver nitrate is reported. This sensor is used for determination of the minute amounts of iodide in lake water samples.  相似文献   

15.
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade?1, and a detection limit of 4.0 × 10?7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.  相似文献   

16.
《Analytical letters》2012,45(10):1861-1873
Abstract

A plasticized PVC membrane containing the lipophilic salt papaverinium-tetraphenylborate was used to construct an ion-selective electrode for papaverine hydrochloride (Pv+Cl?). The electrode shows near Nernstian response over the concentration range 1.6 × 10?5 1.3C × 10?2M PvCl in solutions of pH 1.0–6.2 at 25[ddot]C. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The electrode showed very good selectivity for Pv with respect to a large number of inorganic and organic cations. The potentiometric titration and standard addition methods were used to determine Pv in pure solutions and in pharmaceutical preparations.  相似文献   

17.
A new PVC membrane electrode for the determination of phenylephrine hydrochloride based on the formation of an ionassociation complex of phenylephrine hydrochloride with the phosphotungstate counter anion as an electroactive material dispersed in a PVC matrix is described. The sensor shows a fast, stable, near-Nernstian response for 1.0 × 10?5 to 1.0 × 10?1 M phenylephrine hydrochloride at 25 °C over the pH range of 3.5–8.0 with a cationic slope of 58.1 ± 0.6 mV decade?1. The electrode was successfully used for potentiometric determination of phenylephrine hydrochloride in some pharmaceutical drugs.  相似文献   

18.
《Electroanalysis》2006,18(22):2174-2179
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand of Ethyl‐2‐(benzoylamino)‐3‐(2‐hydroxy‐4‐methoxyphenyl)‐2‐propenoate (EBHMP) as a suitable carrier for Hg2+ ion was described. The electrode exhibit a super Nernstian slope of 48.5±1.0 mV per decade for Hg2+ ion over a wide concentration range from 3.0×10?7–3.1×10?2 M. The lower detection limits are 1.0×10?7 M Hg2+. The electrode has a fast response time (ca. 5 s), a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward Hg2+ ion in comparison to other common cations. The potentiometric responses are independent of the pH of the test solution in the pH range 1.0–4.0. The proposed electrode was used as an indicator electrode in potentiometric titration of mercuric ion with standard solution of EDTA. The direct determination of mercury in spiked wastewater and an amalgam sample gave results that compare favorably with those obtained by the cold vapor atomic absorption spectrometric method.  相似文献   

19.
《Electroanalysis》2004,16(21):1771-1776
In this work a dysprosium [Dy(III)]‐selective solvent polymeric membrane sensor based on N,N‐bis(pyrrolidene) benzne‐1,2‐diamine, poly(vinyl chloride)(PVC), the plasticizer benzylacetate (BA), and anionic site is described. This sensor responds to Dy(III) activity in a linear range from 1.0×10?5 to 1.0×10?1 M, with a slope of 20.6±0.2 mV per decade and a detection limit of 6.0×10?6 M at the pH range of 3.5–8.0. It has a fast response time of<20 s in the entire concentration range, and can be used for at least 2 months without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in the potentiometric titration of fluoride ions and in determination of concentration of F ions in some mouth washing solutions.  相似文献   

20.
In this study, a potentiometric sensor based on a pencil graphite electrode (PGE) coated with polypyrrole doped with Titan yellow dye (PPy/TY) was prepared for potentiometric determination of magnesium ion in aqueous solutions. The structural characteristics of magnesium sensor electrode (PGE/PPy/TYMg) were studied using scanning electron microscopy and Fourier transform infrared along with energy-dispersive spectroscopy. Under the optimal conditions, the electrode reveals a good Nernstian behavior with slope of 28.27 ± 0.40 mV per decade over the concentration range of 1.0 × 10?5–5.0 × 10?2 M and a detection limit of 6.28 × 10?6 M. The potentiometric response of fabricated electrode toward magnesium ion was found to be independent of the pH of the test solution in the pH range of 4.5–8.0. The electrode showed fast response time (<10 s) and good shelf lifetime (>2 months). The prepared magnesium sensor electrode can also be used as an indicator electrode in potentiometric titration of Mg2+ with EDTA with distinguished end point. The electrode revealed good selectivity with respect to many cations including alkali, alkaline earth, transition and heavy metal ions. The introduced magnesium electrode was used for measurement of Mg2+ ion in real samples without any serious interferences from other ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号