首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional matrix-assisted laser desorption/ionization mass spectrometry is limited to analyses of higher molecular weight compounds due to high background noise generated by the matrix in the lower mass region. Surface-assisted laser desorption/ionization (SALDI) mass spectrometry is an alternative solution to this problem. Nanoparticles, structured silicon surfaces and carbon allotropes are commonly used as SALDI surfaces. Here, for the first time, we demonstrate the application of silicon nitride nanoparticles as a suitable medium for laser desorption/ionization of small drug molecules.  相似文献   

2.
Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique which can be used in mass spectrometry to produce ions from biomolecules without inducing the fragmentation associated with traditional methods of ionization. When used with small molecules, the lack of fragmentation allows identification of specific molecules against a background of alternative signals; thus, for example, the presence of drug molecules and metabolites can be distinguished from a range of alternative biomolecules present within a tissue sample. Using highly collimated lasers in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) allows imaging of a tissue sample whereby the laser is rastered across the sample and individual mass spectra are collected in a serial manner. Thus, the distribution of the molecules within the tissue sample can be presented in the form of a 2D image. While the detection of specific drug molecules and metabolites within biological samples has its uses, quantification of those same molecules would be of greater benefit in a clinical setting. However, accurate quantification presents additional challenges. We present an overview of the MALDI-MS technique followed by recent progress in profiling drugs and their metabolites through imaging drug distributions within tissues and finish with recent developments in the quantification of drugs in tissues by MALDI-MSI.  相似文献   

3.
Abstract

Mass spectrometry (MS) has progressed to become a powerful analytical tool for both quantitative and qualitative applications. The first mass spectrometer was constructed in 1912 and since then it has developed from only analyzing small inorganic molecules to biological macromolecules, practically with no mass limitations. Proteomics research, in particular, increasingly depends on MS technologies. The ability of mass spectrometry analyzing proteins and other biological extracts is due to the advances gained through the development of soft ionization techniques such as electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) that can transform biomolecules into ions. ESI can efficiently be interfaced with separation techniques enhancing its role in the life and health sciences. MALDI, however, has the advantage of producing singly charges ions of peptides and proteins, minimizing spectral complexity. Regardless of the ionization source, the sensitivity of a mass spectrometer is related to the mass analyzer where ion separation occurs. Both quadrupole and time of flight (ToF) mass analyzers are commonly used and they can be configured together as QToF tandem mass spectrometric instruments. Tandem mass spectrometry (MS/MS), as the name indicates, is the result of performing two or more sequential separations of ions usually coupling two or more mass analyzers. Coupling a quadrupole and time of flight resulted in the production of high-resolution mass spectrometers (i.e., Q-ToF). This article will historically introduce mass spectrometry and summarizes the advantages and disadvantages of ESI and MALDI along with quadrupole and ToF mass analyzers, including the technical marriage between the two analyzers. This article is educational in nature and intended for graduate students and senior biochemistry students as well as chemists and biochemists who are not familiar with mass spectrometry and would like to learn the basics; it is not intended for mass spectrometry experts.  相似文献   

4.
The response of polycyclic aromatic hydrocarbons (PAHs) to different desorption and ionization fluences has been investigated in a laser desorption/multiphoton ionization/time-of-flight mass spectrometry scheme. The results evidence an intricate relationship between the desorption and ionization steps, tentatively attributed to the amount of internal energy acquired by the desorbed molecules. Different behaviors have been found for the various PAHs considered, leading to a parametric “signature” for each species. Moreover, some insights on the fragmentation mechanism of the desorbed PAHs have been obtained, with possible interpretation in the frame of a “ladder-switching” model.  相似文献   

5.
Direct mass spectrometric analysis of complex biological samples is very important and challenging. In this paper, nanodiamonds have been successfully used in matrix-assisted laser desorption/ionization mass spectrometric analysis of human serum and urine. As a practical tool and platform, it can be widely used in the field of humoral proteomics, and it plays a very promising role in clinical diagnosis, including identification of novel disease-associated biomarkers.  相似文献   

6.
We have used analytical laser induced liquid beam desorption in combination with high resolution mass spectrometry ( mm≥ 1000) for the study of protonated amino acids (ornithine, citrulline, lysine, arginine) and their non-covalently bound complexes in the gas phase desorbed from water solutions. We report studies in which the desorption mechanism has been investigated. The results imply that biomolecule desorption at our conditions is a single step process involving laser heating of the solvent above its supercritical temperature, a rapid expansion, ion recombination and finally isolation and desorption of only a small fraction of preformed ions and charged aggregates. In addition, we report an investigation of the aqueous solution concentration and pH-dependence of the laser induced desorption of protonated species (monomers and dimers). The experimental findings suggest that the desorption process depends critically upon the proton affinity of the molecules, the concentration of other ions, and of the pH value of the solution. Therefore the ion concentrations measured in the gas phase very likely reflect solution properties (equilibrium concentrations). Arginine self-assembles large non-covalent singly protonated multimers (n = 1...8) when sampled by IR laser induced water beam desorption mass spectrometry. The structures of these aggregates may resemble those of the solid state and may be preformed in solution prior to desorption. A desorption of mixtures of amino acids in water solution enabled us to study (mixed) protonated dimers, one of the various applications of the present technique. Reasons for preferred dimerization - leading to simple cases of molecular recognition - as well as less preferred binding is discussed in terms of the number of specific H-bonds that can be established in the clusters.  相似文献   

7.
We examined the application of mass spectrometric methods using resonant ionization by a tunable laser and proposed its use for analyzing hydrogen isotopes. We conducted resonance ionization mass spectrometry (RIMS) to detect gas-phase hydrogen isotope atoms. The ionization efficiency was increased by more than 1000 times that obtained with conventional methods using nonresonant ionization. Resonant laser ablation mass spectrometry (RLAMS) was applied for deuterium detection in solid samples. A graphite substrate implanted with deuterium was used for ordinary laser ablation mass spectrometry (LAMS) and RLAMS. The deuterium signal was observed very clearly by RLAMS, in contrast to LAMS. Mass spectrometry combined with resonance ionization was very useful for hydrogen isotope detection, because components with equal mass numbers were resolved and the method demonstrated higher ionization efficiency. Received: 4 November 1998 / Revised version: 12 January 1999 / Published online: 7 April 1999  相似文献   

8.
Silver nanoparticle synthesized from chemical reduction has been successfully utilized as a matrix in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) of peptides. Acting as a substrate to adsorb analytes, as well as a transmission medium for UV laser, silver nanoparticle was found to assist in the desorption/ionization of peptides with little or no induced fragmentation. The size of the nanoparticle was typically in the range of 160 ± 20 nm. One of the key advantages of silver nanoparticle for peptides analysis is its simple step for on-probe sample preparation. In addition, it also minimizes the interferences of sodium dodecyl sulfate (SDS) surfactant background signal, resulting in cleaner mass spectra and more sensitive signal, when compared to α–cyano-4-hydroxycinnamic acid (CCA) matrix.  相似文献   

9.
Alcohol ethoxylates (AEs) are nonionic surfactants. They are industrially important compounds that have historically been difficult to analyze, with the best results to date achieved through derivatization (e.g., silylation) followed by analysis by gas chromatography/mass spectrometry (GC/MS). Recently, mass spectrometric techniques such as field desorption (FD), time-of-flight secondary ion mass spectrometry (TOF-SIMS), fast atom bombardment (FAB), electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) have been employed to analyze surfynol(R) 4xx. In an effort to produce low-cost alkyl-capped AEs and anionic detergents from AEs, a fast and reliable measure of the product yields and conversions from AEs is required in research. We found that the product yields and conversions from reactions of AEs, obtained by the employment of atmospheric pressure chemical ionization (APCI), were in good agreement with those obtained from proton nuclear magnetic resonance spectroscopy ((1)H-NMR). Therefore, APCI can be used as a validated tool for studying AE reactions. Mixtures that contain either silylated or unsilylated ethoxylates and/or carboxylates yield the same APCI mass spectra. Copyright -Copyright 1999 John Wiley & Sons, Ltd.  相似文献   

10.
During the control of a multistep organic synthesis on a soluble polymer (PEG) by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, a chemical reactivity was encountered when the matrix was acidic, for the samples where the amino moiety of the anchored compounds was protected as a Schiff base. Such imine hydrolysis was proven to be solely mediated by the acidic matrix during analyses since the expected protected structures were detected when the experiments were duplicated with a non-acidic matrix. Even if MALDI mass spectrometry was found to be more convenient than electrospray ionization mass spectrometry for the monitoring of liquid phase organic syntheses, the chemical reactivity imparted by the use of a matrix must be taken into account to avoid erroneous spectra interpretations. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   

11.
Gold nanoparticles (AuNPs) were applied and optimized as matrix for matrix-assisted laser desorption/ionization mass spectrometry analysis of animal tissues, and enabled histological analysis of animal tissues at molecular level by imaging mass spectrometry (IMS). AuNPs were coated on animal tissue in a solvent-free manner via argon ion sputtering. Metabolites, including neurotransmitters, fatty acids and nucleobases, were directly detected from mouse brain tissue. Based on region-specific chemical profiles, fine histological features of mouse brain tissue and heterogeneous regions of tumor tissue were both revealed.  相似文献   

12.
介绍了一种将红外激光解吸/真空紫外光电离质谱技术应用于分析胆固醇的新方法. 由于近阈值单光子电离作用,可以在低能量下只产生纯净的胆固醇分子离子峰;增加光子能量则可以使碎片离子峰大量出现. 为了验证碎片离子的归属,利用商用高分辨电子轰击电离-飞行时间质谱仪分析并指认了胆固醇主要的碎片峰. 此外,采用量子化学从头算的方法研究了胆固醇母体离子和碎片构型,并讨论了部分主要的光解离机理  相似文献   

13.
The ionization mechanisms of several atmospheric pressure ion sources based on desorption and ionization of samples deposited on a surface were studied. Home-built desorption electrospray ionization (DESI), laserspray ionization (LSI), and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources were characterized using low-molecular-weight compounds, in particular fluorescent dyes. Detection of the desorbed and ionized species was performed by laser-induced fluorescence and ion cyclotron resonance mass spectrometry. The dependences of the signal intensities on various experimental parameters were studied. The data obtained reveals common features, such as formation of solvated species and clusters in the ionization processes, in all of the techniques considered.  相似文献   

14.
Molecular imaging by Mid-IR laser ablation mass spectrometry   总被引:1,自引:0,他引:1  
Mid-IR laser ablation at atmospheric pressure (AP) produces a mixture of ions, neutrals, clusters, and particles with a size distribution extending into the nanoparticle range. Using external electric fields the ions can be extracted and sampled by a mass spectrometer. In AP infrared (IR) matrix-assisted laser desorption ionization (MALDI) experiments, the plume was shown to contain an appreciable proportion of ionic components that reflected the composition of the ablated target and enabled mass spectrometric analysis. The detected ion intensities rapidly declined with increasing distance of sampling from the ablated surface to ∼4 mm. This was rationalized in terms of ion recombination and the stopping of the plume expansion by the background gas. In laser ablation electrospray ionization (LAESI) experiments, the ablation plume was intercepted by an electrospray. The neutral particles in the plume were ionized by the charged droplets in the spray and enabled the detection of large molecules (up to 66 kDa). Maximum ion production in LAESI was observed at large (∼15 mm) spray axis to ablated surface distance indicating a radically different ion formation mechanism compared to AP IR-MALDI. The feasibility of molecular imaging by both AP IR-MALDI and LAESI was demonstrated on targets with mock patterns. Presented at the 9-th International Conference on Laser Ablation, 2007 Tenerife, Canary Islands, Spain  相似文献   

15.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used for the characterization of a partially transesterified poly(beta-hydroxyalkanoate), PHA, polymer produced by the bacterial strain Alcaligenes eutrophus using saponified vegetable oils as the sole carbon sources. The transesterification was carried out separately under acidic and basic conditions to obtain PHA oligomers weighing less than 10 kDa. The intact oligomers were detected in their cationized [M + Na](+) and [M + K](+) forms by MALDI-TOFMS. A composition analysis, using the MALDI-TOF spectra, indicate that the oligomers obtained via acid catalysis were terminated with a methyl 3-hydroxybutyrate end group, and those obtained by base catalysis had a methyl crotonate (olefinic) termination. In addition to HB (hydroxy butyrate), the oligomers were found to contain a small percentage of HV (hydroxy valerate). This was independently confirmed using gas chromatography/mass spectrometry (GC/MS). In comparison, the analysis of a commercial PHA polymer, transesterified under identical conditions, only showed the presence of HB, i.e. a pure PHB homopolymer. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   

16.
基于激光离子源的飞行时间质谱法作为一门新兴的成像方法,已经被广泛应用于材料、地质、环境、药物和生命科学领域中。但受限于光学衍射极限、聚焦透镜的焦距和数值孔径等因素,使其难以实现亚微米尺寸的高空间分辨率成像。近场技术的引入成功地解决了光学衍射极限的限制,将近场技术与激光电离技术相结合,可以实现对固体样品表面纳米级弹坑的剥蚀。此外,传统的质谱成像技术常常假设样品表面是平整的,忽略其表面形貌的高低起伏,但这往往会导致信号强度不稳定和成像假象。为此,不仅需要获得样品中的化学组成与空间分布,还需同时获得样品表面的形貌信息,才能实现多功能的原位表征。在自行研制的激光解吸/电离飞行时间质谱的基础上,采用近场纳米有孔针尖离子源代替传统的远场激光聚焦,以532 nm波长激光为第一束解析激光,355 nm波长激光为后电离激光,音叉式原子力显微镜控制系统针尖与样品之间的距离维持在近场范围内,对酞菁铜镀层样品表面进行了弹坑剥蚀实验,获得了直径为550~850 nm的弹坑点阵;并对7.5 μm×7.5 μm的标准酞菁铜网格样品进行了铜离子亚微米级的高分辨率成像;此外,纳米有孔针尖离子源作为原子力显微镜的一种变体,还可同时获得成像区域的表面形貌信息,这一结合优势大大拓展了质谱技术在微纳尺度下的原位表征能力。  相似文献   

17.
Abstract: Mass spectrometry (MS) has become an integral tool in life sciences. The first step in MS analysis is ion formation (ionization). Many ionization methods currently exist; electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most commonly used. ESI relies on the formation of charged droplets releasing ions from the surface (ion evaporation model) or via complete solvent evaporation (charge residual model). MALDI ionization, however, is facilitated via laser energy and the use of a matrix. Despite wide use, ESI cannot efficiently ionize nonpolar compounds. Atmospheric pressure chemical ionization (APCI) and atmospheric pressure photo ionization (APPI) are better suited for such tasks. APPI requires photon energy and a dopant, whereas APCI is similar to chemical ionization. In 2004, ambient MS was introduced in which ionization occurs at the sample in its native form. Desorption electrospray ionization (DESI) and direct analysis in real time (DART) are the most widely used methods. In this mini-review, we provide an overview of the main ionization methods and the mechanisms of ion formation. This article is educational and intended for students/researchers who are not very familiar with MS and would like to learn the basics; it is not for MS experts.  相似文献   

18.
The results of comparative analysis of laser desorption/ionization, matrix-assisted laser desorption/ ionization, and new laser-induced electron transfer desorption/ionization methods, used to detect chlorophyll A; mercury complex with thiuram; platinum complex with mercaptoquinoline; and lutetium complex with phthalocyanine, modified by crown ether, are presented. The new method is found to have a better ionization efficiency for complex compounds than the conventional laser desorption/ionization methods.  相似文献   

19.
Characterization of polycyclic aromatic hydrocarbons (PAHs) samples has been performed by laser desorption combined with multi-photon ionization technique using two different geometries of the ionization laser beam. This comparative study evidences the strong influence of ionization laser fluence on PAH fragmentation. Through a ∼103 enlargement of the ionization probe volume and 104 reduction of laser fluence over previous studies, fragment free mass spectra are obtained with higher sensitivity and selectivity. The ability to measure fragment free PAH mass spectra is a very important step in the end goal of measuring complex unknown mixtures of PAH desorbed from solid surface such as soot samples.  相似文献   

20.
《应用光谱学评论》2013,48(3):275-303
ABSTRACT

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is a technique that has attracted widespread interest since its introduction in 1988. It is primarily implemented using time-of-flight or trapped ion mass analyzers and greatly facilitates determination of molecular weights for biomolecules, polymers, and natural products. Numerous publications on these and related applications have appeared during the past ten years. The present brief MALDI review is intended to provide selected coverage of recent literature, with special emphasis on applications to proteomics, whole cells and tissues, polymers, organic and inorganic molecules. In view of the intense current interest, the choice of topics emphasizes biochemically-related applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号