首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
The purpose of this study was to determine the prevalence of bone marrow edema in the greater tuberosity of the humerus on MR imaging, the association with other findings at MR imaging and the injury mechanism which can lead to this finding.Subjects and methods: MR reports from 863 patients referred for shoulder MRI over 74 months were reviewed to identify patients with marrow edema in the greater tuberosity. The MR images from patients with greater tuberosity marrow edema were reviewed by consensus of two radiologists for the extent of marrow edema and for associated injuries. Marrow edema in the greater tuberosity was seen in 11 of 863 patients (1.3%). Nine patients (82%) had associated rotator cuff tear by MR imaging (four full thickness and five partial thickness), one patient had avulsion of the greater tuberosity from the humerus, and one had no rotator cuff abnormality. History of trauma was reported by eight patients including fall without direct blow to the shoulder (6), car accident (1) and direct blow to the top of the shoulder (1). Marrow edema in the greater tuberosity is an infrequent finding. Marrow edema most often is associated with a history of trauma and with rotator cuff abnormalities including full thickness tears. The history of trauma without direct blow to the shoulder and the location of the edema indicates that marrow edema often results from avulsion injury by the supraspinatus tendon.  相似文献   

2.
MRI-negative rotator cuff tears   总被引:2,自引:0,他引:2  
We report two cases of rotator cuff tear in which the T(2)-weighted MRI signal was negative at the first examination, but positive by the second examination without any changes in symptoms. Many authors have reported on correlations between the MRI and operative findings of rotator cuff tears. However, MRI findings, history of symptoms and operative findings in our patients suggest that there was a discrepancy between symptoms and MRI findings dependent on the period from the injury. Operative findings also indicate that intratendinous tears might have occurred first in these patients then progressed to partial or full thickness tears over time. We concluded that physicians should keep rotator cuff pathology in mind even in patients whose MRI findings are negative but symptoms of rotator cuff tear persist.  相似文献   

3.
Magnetic resonance elastography (MRE) and ultrasound shear wave elastography (SWE) are imaging techniques to measure stiffness of the soft tissue using magnetic resonance imaging (MRI) and ultrasound images, respectively. The purpose of this study was to explore the feasibility of the MRE measurement to evaluate the change in supraspinatus (SSP) muscle stiffness before and after rotator cuff tear, and to compare the result with those of SWE. Six swine shoulders were used. The skin and subcutaneous fat were removed, and the stiffness value of the SSP muscle was measured by MRE and SWE. The MRE measurement was performed with 0.3 T open MRI and the vibration from a pneumatic driver system with active driver to a passive driver to create the shear wave in the tissue. The passive driver was placed on the center of the SSP muscle. The stiffness was estimated from the wave images using local frequency estimation methods. In the SWE measurement, the probe of the ultrasound was placed on the center of the SSP muscle. The shear wave propagation speed was measured at a depth of 1 cm from the surface, and the stiffness was calculated. After those measurements, the rotator cuff tendon was detached from the greater tuberosity, and MRE and SWE measurements were then performed in the same manner again. The differences in the stiffness values were compared between before and after the rotator cuff tendon tear on both the MRE and SWE measurements. The results indicated that stiffness values on MRE and SWE were 9.3 ± 1.8 and 10.0 ± 1.2 kPa respectively before the rotator cuff tear, and 7.3 ± 1.3 and 8.0 ± 0.8 kPa respectively after the tendon detachment. Stiffness values were significantly lower after the tendon detachment on both the MRE and SWE measurements (p < 0.05). Our results demonstrated that stiffness values of the SSP muscle on MRE and SWE were lower after rotator cuff detachment. From this result, MRE may be a feasible method for quantification of the change in rotator cuff muscle stiffness.  相似文献   

4.

Purpose

The purpose of the study was to validate the diagnostic performance of high-resolution isovolumetric magnetic resonance arthrography (MRA) for intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist as compared to conventional MR imaging (MRI).

Materials and methods

Forty-eight patients with traumatic TFCC tears at arthroscopy were enrolled. All patients had underwent proton-density- and T2-weighted MRI before arthrography and three-dimensional T1 high-resolution isovolumetric examination (3D-THRIVE) MRA on a 3-T MR. We assessed the presence of scapholunate interosseous ligament (SLIL)/lunotriquetral interosseous ligament (LTIL) or TFCC tears using the arthroscopy as a gold standard.

Results

Arthroscopy revealed 37 TFCC central tears, 15 TFCC peripheral tears, 20 SLIL tears and 13 LTIL tears. Sensitivities of MRI and MRA were 70.3% and 94.6% for detection of TFCC central tears, 60.0% and 93.3% for detection of TFCC peripheral tears, 65.0% and 85.0% for SLIL tears, and 61.5% and 84.6% for LTIL tears. The specificity of the MRI was 100% for the detection of ligaments and TFCC tears. The specificities of the MRA for detection of TFCC central tears, TFCC peripheral tears, SLIL tears and LTIL tears were 100%, 97%, 96.4% and 100%, respectively.

Conclusion

Isovolumetric 3D-THRIVE wrist MRA provided better results for depiction of intrinsic ligament and TFCC tears than wrist MRI.  相似文献   

5.
This study assessed the diagnostic test accuracy of magnetic resonance imaging (MRI) in the detection of partial- and full-thickness rotator cuff tears in the adult population. A systematic review was conducted of the following electronic databases: Cochrane Central Register of Controlled Trials, Medline, Embase, CINAHL, AMED, ISI Web of Science, Current Controlled Trials, National Technical Information Service, the National Institute for Health Research Portfolio, the UK National Research Register Archive and WHO International Clinical Trials Registry Platform database and reference lists of articles. All studies assessing the sensitivity and/or specificity of MRI for adult patients with suspected rotator cuff tear where surgical procedures were the reference standard were included in the study. A meta-analysis was performed to calculate pooled sensitivity, specificity, likelihood and diagnostic odds ratio values, and summary receiver operating characteristic plots were constructed. Forty-four studies were included. These included 2751 shoulders in 2710 patients. For partial-thickness rotator cuff tears, the pooled sensitivity and specificity values were 0.80 [95% confidence interval (CI): 0.79-0.84] and 0.95 (95% CI: 0.94-0.97), respectively. For full-thickness tears, the sensitivity and specificity values were 0.91 (95% CI: 0.86-0.94) and 0.97 (95% CI: 0.96-0.98), respectively. While there was no substantial difference in diagnostic test accuracy between MRIs reviewed by general radiologists and those reviewed by musculoskeletal radiologists, higher-field-strength (3.0 T) MRI systems provided the greatest diagnostic test accuracy.  相似文献   

6.
The aim of this study was to determine the value of a fat suppressed 3D gradient-echo sequence (GRE) data set in comparison to a 2D GRE sequence in direct MR arthrography of the shoulder. For this purpose we examined 50 consecutive patients with subacute or chronic disorders of the shoulder using a 1.5 T scanner: Transverse T1-weighted 2D (slice thickness 4 mm) and 3D GRE (slice thickness 1.5 mm reconstructed from 3 mm), oblique coronal T2- and T1-weighted turbo spin-echo (TSE) and sagittal T1-weighted TSE with fat saturation were applied. Visual image analysis of anatomical and pathological structures was performed by two independent observers. A correlation to surgical results was available in 21 patients. Transverse GRE sequences were well suited for analysis of the anterior/posterior labrum, the middle glenohumeral ligament, and cartilage. 3D GRE with fat suppression was slightly superior to 2D GRE without fat suppression in the evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament, whereas for cartilage no significant differences were found between both sequences. Concerning pathological findings, in most of the cases 2D delivered the same results as 3D. In conclusion, a T1-weighted 3D GRE data set with fat saturation in transverse orientation may be useful for evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament. However, similar measured slice thickness of 3 mm-even if interpolated to 1.5 mm-compared to a 2D sequence with 4 mm does not provide significant diagnostic advantages.  相似文献   

7.

Purpose

The long-term goal of our research is to develop a patient-specific biomechanical model of the supraspinatus muscle and tendon for analyzing the effects of fatty infiltration and pennation angle changes. One input of the model will be the amount and distribution of fat within the muscle. Therefore, the objective of this project was to adapt and validate a novel magnetic resonance imaging pulse sequence for quantifying the extent of fatty infiltration for the supraspinatus muscle.

Methods

Samples of incremental combinations of muscle and fat from a cow were prepared and scanned with our quantitative MR technique. The MR results were compared to actual fat measurements taken using a Soxtec extraction analyzer.

Results

The MR fat quantification results closely match those values determined by Soxtec analysis (R2=.98, root mean square deviation=4.9).

Conclusions

Our MR fat quantification protocol can be used to accurately quantify fatty infiltration in skeletal muscle. This ability to evaluate skeletal muscle tissue noninvasively will improve the efficacy of evaluation of fatty degeneration in assessing tissue quality preoperatively. This can be important in surgical planning of any musculoskeletal repairs, particularly rotator cuff tears.  相似文献   

8.
To evaluate changes in capsular mechanisms and the labroligamentous complex with magnetic resonance arthrography (MRA) after shoulder surgery and to establish possible criteria for the expected post-operative appearance of the shoulder. MRA of the shoulder was performed in 16 patients, before and 6 months after undergoing arthroscopic surgery for recurrent unidirectional dislocation. MR studies were performed after application of a constant amount of contrast solution (2 mmol Gd-DTPA). Axial and coronal oblique T1-weighted images were obtained with and without fat suppression techniques. Anterior (a) and posterior (p) capsular distances were measured, and the p/a ratio was established. Capsule thickness, capsular leaking, estimation of the volume of the axillary recess, appearance of the glenohumeral ligaments, and evidence of labral lesions were compared on pre- and postoperative images. Mean anterior capsular distance (a) decreased from 9.73 +/- 1.03 mm preoperatively to 5.27 +/- 2.49 mm postoperatively, whereas dorsal capsular distance (p) increased from 6.13 +/- 2.36 to 8.93 +/- 2.37. The p/a ratio increased from 0.64 +/- 0.25 to 2.36 +/- 2.54 (p = 0.007). Capsular leaking was suspected preoperatively in seven patients, but was not evident postoperatively. Capsular thickness and the estimated volume in the axillary recess did not change significantly. Contrast extension into pre-existent labral tears (nine patients) decreased or were not evident postoperatively. Changes in the appearance of the glenohumeral ligaments were found in six patients. Changes in capsular distances might be indicative of a decreased capsular laxity and could be a valuable criterion in the evaluation of the postoperative shoulder. Postoperative follow-up of labral tears is demonstrated by a decrease in contrast extension into or under a tear. Reactive capsular thickening or scar tissue formation can be reactive or preexistent. Changes in ligaments might be secondary to surgery. MRA may be helpful in the reevaluation of patients with suspected recurrent instability.  相似文献   

9.
The purpose of this study was to describe the magnetic resonance imaging findings of granulomatous hepatitis on T1-weighted, T2-weighted and postgadolinium images. Eight patients with histopathological diagnosis of granulomatous hepatitis were evaluated in this study. MRI examinations included precontrast T1-weighted breath-hold spoiled gradient echo, breathing independent STIR sequences, and T1-weighted breath-hold spoiled gradient-echo sequence following after i.v. gadolinium administration in arterial, intermediate and late phases. Diffuse nodular liver involvement was visualized in all patients. Nodules were consistent with granulomas and were 0.5-4.5 cm in diameter. Caseating granulomas were intermediate and high signal on T2-weighted, low signal on T1-weighted images. They revealed no enhancement in two patients, and enhanced in one patient. Noncaseating granulomas revealed intermediate signal on T1, and T2-weighted images and increased enhancement on arterial phase images with persisting enhancement in late phase images. Portal lymph nodes were visible in five patients. Splenomegaly was present in five patients. Granulomatous hepatitis has spectrum of MRI features, to be considered in differential diagnosis with other diffuse nodular liver pathologies.  相似文献   

10.
The purpose of this study was to assess the effect of chemical shift artifacts and fat suppression between contrast-enhanced T1-weighted fast spin-echo (FSE) sequence with fat suppression and contrast-enhanced T1-weighted fluid attenuated inversion recovery (FLAIR) sequence with fat suppression in magnetic resonance imaging (MRI) of the thoracic spine at 3.0T. Forty patients, who underwent MRI examination, were recruited and analyzed both qualitatively and quantitatively. Due to chemical shift artifacts in the T1-weighted FSE, 14 of the patients were found to be of non-diagnostic value. On the contrary, in 11 of those 14 patients, no chemical shift artifacts were observed in the T1-weighted FLAIR sequence. Regarding the efficiency of fat suppression, both sequences achieved successful fat suppression. Consequently, the use of T1-weighted FLAIR fat suppression after contrast administration sequence seems to eliminate or significantly reduce image quality deterioration stemming from chemical shift artifacts in thoracic spine examinations.  相似文献   

11.
MR evaluation of giant cell tumors of the tendon sheath   总被引:1,自引:0,他引:1  
Giant cell tumor of the tendon sheath (GCTTS) is a benign condition that involves the synovium of the tendon sheaths. Histologically, GCTTS is similar to pigmented villonodular synovitis. The MRI findings in two cases of GCTTS are reported. In both cases, predominantly low signal is seen on T1-weighted, proton density weighted, and T2-weighted images. This information may be useful in distinguishing GCTTS from other mass lesions involving the tendon sheaths.  相似文献   

12.
Superparamagnetic iron oxide (SPIO)-enhanced MRI was performed in twenty-one patients undergoing proton-beam radiotherapy for hepatocellular carcinomas. Patients were divided into two groups: early and late phase hepatic injuries. Each group was investigated 3 to 9 weeks and 4 to 65 months after the start of irradiation, respectively. T(1)-weighted, T(2)-weighted, and T(2)*-weighted images were obtained before and after SPIO administration. In all postcontrast sequences in the early phase, irradiated livers demonstrated relatively higher intensity than nonirradiated livers and the radiation-to-liver contrast-to-noise ratio (C/N) was improved. Postcontrast T(2)*-weighted images showed the highest C/N. In the late phase, the irradiated areas showed high intensity on T(2)-weighted images and low intensity on T(1)-weighted images without SPIO, while high intensity on T(1)-weighted images with SPIO. The C/N increased with SPIO in all sequences and postcontrast T(2)-weighted images showed the highest C/N in the late phase. SPIO-enhanced MRI is useful to evaluate this entity both in the early and late phase of clinical studies.  相似文献   

13.
We report a case of multiple hemorrhagic cerebral metastases from papillary thyroid cancer, with reference to T(2)*-weighted gradient echo (GRE) magnetic resonance imaging (MRI). Small metastatic nodules were recognized as round nodules with signal loss on T(2)*-weighted GRE MRI, and were more pronounced compared with other sequences. Lesions were later confirmed as hemorrhagic on T(1)- and T(2)-weighted MRI. T(2)*-weighted GRE MRI was a sensitive tool for early detection of metastases displaying hemorrhagic changes.  相似文献   

14.
The purpose of this study was to describe the magnetic resonance imaging (MRI) appearance of hepatic alveolar echinococcosis (HAE) on T(1)-weighted, T(2)-weighted and postgadolinium images. A total of 13 lesions were demonstrated in 13 patients. All patients underwent MR examination at 1 T imager. MR examinations included precontrast T(1)-weighted breathing averaged spin echo (SE), breath-hold spoiled gradient echo, T(2)-weighted TSE sequences with and without fat suppression, and T(1)-weighted breath-hold spoiled gradient echo (SGE) sequence following i.v. after gadolinium administration. All lesions were confirmed with histopathology. HAE hepatic lesions revealed geographic patterns of variable signal intensities on noncontrast T(1)- and T(2)-weighted images. Slightly hyperintense, iso- and hypointense signal on T(1)-weighted images corresponded to calcified regions, which appeared hypo-isointense signal on T(2)-weighted images. Necrotic areas were hypointense signal on T(1)-weighted and hyperintense signal on T(2)-weighted images. On postgadolinium images, lesions did not reveal enhancement. Dilatation of intrahepatic bile ducts distal to HAE abscesses were observed in five patients and portal vein invasion or compression was observed in four patients, lobar atrophy of the liver was coexistent finding in cases with portal vein compression. The MRI appearance of HAE abscesses included large irregularly marginated masses with heterogenous signal on T(1)- and T(2)-weighted images and lack of enhancement with gadolinium.  相似文献   

15.
The purpose of this study was to evaluate the appearance of infectious cholangitis on MRI. The MR images of 13 patients (9 women, 4 men; age range, 14-79 years) with clinically confirmed infectious cholangitis, who represent our complete 9.5 year experience with this entity, were retrospectively evaluated. All MR studies were performed at 1.5 T and included: in-phase and out-of-phase T(1)-weighted spoiled gradient echo (SGE), T(2)-weighted fat-suppressed echo train spin echo, single shot T(2)-weighted sequences, and serial postgadolinium T(1)-weighted SGE sequences without and with fat-suppression. The biliary ductal system was evaluated regarding presence of dilatation, stenosis, wall irregularities, wall thickening, and gadolinium enhancement of duct walls. The liver parenchyma was evaluated regarding focal signal abnormalities on precontrast and serial postgadolinium images. Biliary ductal dilatation was observed in 100% of patients. Mild to moderate thickening of bile duct walls combined with increased enhancement on postgadolinium images was observed in 92% of patients. The liver parenchyma showed periportal or wedge-shaped areas of hyperintense signal on T(2)-weighted images in 69% of patients. On T(1)-weighted images, 54% of patients showed areas of hypointense signal and 15% of patients showed wedge-shaped hyperintense areas. Areas with increased enhancement on immediate postgadolinium SGE were observed in 58% of patients, and in 42% of patients increased enhancement persisted on 2 min postgadolinium fat-suppressed images. Distinctive MRI findings on pre- and postgadolinium images are appreciated for infectious cholangitis.  相似文献   

16.
PurposeTo implement a fast (~ 15 min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3 Tesla MRI scanner.Materials and methods7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences.ResultsAverage examination time of the proposed protocol was 14.6 min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R = 0.96 for T1-weighted and 0.98 for T2-weighted, p < 0.001) regarding vessel wall thickness measurements.ConclusionThe proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.  相似文献   

17.
Sonographic evaluation of subacromial space   总被引:2,自引:0,他引:2  
Azzoni R  Cabitza P  Parrini M 《Ultrasonics》2004,42(1-9):683-687
GOAL OF THE STUDY: The purpose of this study is to compare the accuracy of sonographic to radiographic measurements of subacromial space, and verify its variations in relation to acromial morphology, age, sex and rotator cuff pathologies. MATERIALS AND METHODS: As a result, we have compared a radiographic examination to sonographic examination, each measuring the subacromial space in 200 random shoulders, with a personal method. The sonographic examination was performed by using a HDI 5000 ultrasound scanner Sono-CT with 7.5 MHz linear array transducer. No stand-off pad was utilized. RESULTS: The statistical analysis of the data derived from the two measurements was not sufficient to conclude that the two techniques are different (p>0.8). They also correspond with the radiographic morphology of the acromion. The size of subacromial space was related to the acromial morphology, female gender, and rotator cuff pathology, however, it was not related to age. DISCUSSION AND CONCLUSIONS: Our results clearly show that sonographic measurements are very close to those obtained by X-ray (p>0.8). The Bland-Altman analysis showed that for all groups, the were small enough to give us confidence that the sonographic technique may be used in place of the radiographic one for clinical purposes. One-way ANOVA showed that sonographic measurements were statistically different among the four groups (p<0.05). The sonography demonstrated precision, accuracy and carefulness in the measurement of the subacromial space.  相似文献   

18.
We retrospectively reviewed MR studies on 10 patients with renal-related perinephric fluid collections who underwent MRI in three institutions between January 2001 and August 2004. All patients underwent MRI of the abdomen and T1-weighted, T2-weighted and serial contrast-enhanced images, including delayed-phase contrast-enhanced images 10-12 min after contrast injection, were obtained. Perinephric fluid collections in 5 patients revealed MRI findings of simple fluid content (i.e., hypointense on T1-weighted images and hyperintense on T2-weighted images). In another 5 patients, a complex perinephric fluid content (i.e., mixed hyper/hypointense on T1-weighted images and mixed hypo/hyperintense on T2-weighted images compatible with blood breakdown products and pus) was observed. In 5 patients, contrast extravasation on late-phase images that was compatible with urine leak was demonstrated. Our results suggest that MRI may determine the content of perinephric fluid collections on noncontrast T1-weighted and T2-weighted images and that contrast extravasation on late-phase images is associated with urine extravasation from renal collecting systems.  相似文献   

19.
PURPOSE: To describe the use of 3.0-T magnetic resonance imaging (MRI) for the evaluation of chronic liver diseases. MATERIALS AND METHODS: Two groups of patients who had chronic liver diseases and underwent 3.0-T MRI for evaluation of the liver were included in the study. The first group of patients included 66 consecutive patients (33 male, 33 female; mean age+/-standard deviation, 56+/-11). The second group of patients included 30 consecutive patients (18 males, 12 females; mean age+/-standard deviation, 53+/-10) in whom Variable-Rate Selective Excitation (VERSE) pulses and improved adjustments procedure were used during the acquisitions. Imaging findings of chronic liver diseases, predetermined artifacts and image quality of all individual sequences in the first group and predetermined artifacts and image quality of T2-weighted sequences in the second group were reviewed retrospectively and independently by two reviewers. chi-Square tests were used to compare the findings between two groups of patients and individual sequences. Kappa statistics were used to determine the extent of agreement between the reviewers. RESULTS: Fifteen dysplastic nodules in 6 of 66 (9%) patients and 12 hepatocellular carcinomas in 11 of 66 (17%) patients were detected. Excluding motion artifacts, three-dimensional (3D) T1-weighted gradient-echo (GE) sequence was the least affected sequence by the artifacts. Image quality of T1-weighted 3D-GE sequences was excellent in 43 of 66 (65%) patients. In-phase and out-of-phase T1-weighted spoiled GE (SGE) images were fair in 62 of 66 (94%) and 61 of 66 (92%) patients, respectively. The image quality of short tau inversion recovery (STIR) and half-Fourier rapid acquisition with relaxation enhancement (RARE) sequences were fair in 31 of 66 (47%) and 53 of 66 (80%) patients. STIR and half-Fourier RARE sequences in the second group demonstrated significantly better image quality (P=.03 and P<.0001). CONCLUSION: 3.0-T MRI allows the acquisition of very high quality postgadolinium 3D-GE sequence, which permitted the detection and characterization of lesions in the setting of chronic liver diseases. The use of VERSE pulses and improved adjustments procedure improved the image quality of T2-weighted sequences. In-phase/out-of-phase SGE sequences are at present of fair quality.  相似文献   

20.

Purpose

This study was done to test a series of MR sequences for evaluating the sciatic nerve after total hip arthroplasty (THA).

Material and Methods

The study protocol was approved by the institutional review board. Informed consent was obtained from all patients. Twenty-five patients (11 men and 14 women mean age: 62.3±5.7 years) with THA were included in this prospective study. MRI protocol included sequences that were preliminarily tailored for nerve imaging in patients with THA: proton density (PD)-weighted turbo SE, T1-weighted turbo SE (TSE) 3 mm thickness, T1-weighted turbo SE (TSE) 6 mm thickness, T1-weighted turbo SE with high bandwidth (TSE hBW), T2- weighted TSE, T2-weighted with fat saturation and short-tau inversion recovery (STIR). For each sequence, we evaluated the visibility of the sciatic nerve using a semiquantitative score (0=total masking; 1=insufficient visibility; 2=sufficient visibility; 3=optimal visibility). The sum of the scores given to each sequence was divided by the maximal sum, obtaining a percentage visibility index. Friedman and sign tests were used for statistical analysis.

Results

MR examination time was approximately 40 min. No patients reported pain, heat or symptoms related to nerve stimulation. The visibility index ranged between 88% and 70% for the first four sequences. The T1-weighted TSE hBW sequence had the best visibility index (P<.05). The visibility indexes of the first four sequences were significantly higher (P<.004, sign test) than those of the remaining three sequences.

Conclusion

The sciatic nerve could be studied at 1.5 T in patients following THA. The nerve is better visualized with T1-weighted TSE hBW sequences. On T2-weighted sequences and STIR, the visibility of the nerve is low.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号