首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Due to the importance of B1 and B6 vitamins for human health it is useful to develop new cheap and rapid methods for their determination. Voltammetric behavior of these vitamins on a pencil graphite electrode was investigated using cyclic voltammetry in different media. Direct quantitative determination of the two vitamins, one in the presence of the other, was done by differential pulse voltammetry. Vitamin B1 was electroactive only in a NaOH solution generating two irreversible oxidation peaks; the first peak obtained at 250 mV is well-defined and was used in quantitative determinations. In case of vitamin B6, a well-defined oxidation peak was observed in all investigated supporting electrolytes except for HCl. The linear concentration ranges were 10?5–10?3 M for vitamin B1 in a NaOH solution and 5 × 10?6–10?3 M for vitamin B6 in an acetate buffer solution. The obtained detection limits were 5.34 × 10?6 M and 2.81 × 10?6 M for vitamin B1 and vitamin B6, respectively. The developed method is simple and rapid and it was successfully applied in the determination of the two vitamins in pharmaceuticals.  相似文献   

2.
Conditions convenient for the determination of traces of seIenium(IV) by cathodic stripping technique are described. Several electrolytes were tested. Three procedures are given in which the troublesome splitting of the stripping peak is eliminated. Suitable conditions include perchloric acid solution at elevated temperature, hydrochloric acid solution after preconcentration at zero current, and perchloric acid solution containing a small amount of iodide. The detection limits are 5 × 10-9, 2 × 10-9 and 5 × 10-10 mol dm-3, respectively. The time required for the entire procedure is about 30 min starting with a soluble seIenium(IV) sample.  相似文献   

3.
《Electroanalysis》2006,18(12):1193-1201
A chemically modified carbon paste electrode with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one (2,7‐BFEFMCPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The diffusion coefficient (D=1.89×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient, α (=0.42) of ascorbic acid oxidation at the surface of 2,7‐BFEFMCPE was determined using electrochemical approaches. It has been found that under an optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 300 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak currents show a linear dependence on the ascorbic acid concentration and linear analytical curves were obtained in the ranges of 8.0×10?5 M–2.0×10?3 M and 3.1×10?5 M–3.3×10?3 M of ascorbic acid with correlation coefficients of 0.9980 and 0.9976 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2δ) were determined to be 2.9×10?5 M and 9.0×10?6 M with cyclic voltammetry and differential pulse voltammetry, respectively. This method was also examined for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

4.
《Analytical letters》2012,45(1):93-109
ABSTRACT

A second derivative spectrophotometric method has been developed for the determination of palladium and platinum in mixtures. The method is based on the formation of the platinum and palladium complexes with 3-(2-thiazolylazo)-2, 6-diaminopyridine, (2, 6-TADAP), in the presence of 1.7 M perchloric acid solution, upon heating at 90° C for 30 min and on the subsequent direct derivative spectrophotometric measurement. The zero-crossing approach and the graphic method were used for determination of platinum and palladium, respectively. Each analyte was determinated in the presence of one another in the ranges 8.9×10-7 -3.1×10-5 M for platinum and 4.6×10-7 - 6.8×10-5 M, for palladium. The detection limits achieved (3a) were found to be 2.7×10-7 M of platinum and 1.4×10-7 M of palladium. The relative standard deviations were in all instances less than 1.0%. In this work is included a study of effect of interferents and the application of the proposed method in synthetic mixtures.  相似文献   

5.
A novel voltammetric method using the Ppyox/NFR/Au (poly pyrrole – nuclear fast red – gold) modified electrode was developed for simultaneous measurement of various combinations of ascorbic acid (AA) and methyldopa (MDA). Polypyrrole film was prepared by incorporation of nuclear fast red (NFR) as doping anion, during the electropolymerization of pyrrole onto a gold (Au) electrode in aqueous solution using cyclic voltammetric (CV) method, and then it was overoxidized at constant potential. Differential pulse voltammetry was utilized for the measurement of both analytes using modified electrode. Well‐separated voltammetric peaks were observed for ascorbic acid (AA) and methyldopa at the Ppyox/NFR/Au modified electrodes with peak separation of 0.210 V. It has been found that under optimum condition (pH 3.0), the oxidation of AA and MDA at the surface of the electrode occurs at a potential about 260 and 50 mV less positive than unmodified Au electrode respectively. The current catalytic oxidation peaks showed a linear dependent on the concentration of AA and MDA in the range of 9.0×10?6 to 1.0×10?3 and 1.0×10?7 to 2.0×10?5 mol L?1 respectively. The detection limit of 5.8×10?6 and 5.0×10?8 mol L?1 (S/N=3) were obtained for AA and MDA respectively. The modified electrode was used for determination of AA and MDA in some real samples such as human serum and tablet.  相似文献   

6.
The adsorption of benzotriazole (BTA) on commercial copper surfaces in hydrochloric (HCl) acid concentrations from 1 × 10?3 to 5 × 10?1 M was investigated using gravimetric measurements. BTA in bulk solution was tested in concentrations from 1 × 10?5 to 1 × 10?1 M at temperatures from 298 to 328 K. The adsorption mechanism is discussed using the objective function (OF) and in terms of applicability of the conventional isotherm models. The best fit was obtained using the Frumkin equation. The projected molecular area of BTA was calculated to elucidate inhibitor orientation in the adsorption process. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

7.
Zirconium was quantitatively extracted with 2.5 × 10?2 M dicyclohexyl-18-crown-6 in dichloromethane from 8.5 M hydrochloric acid. It was stripped with 0.5 M hydrochloric acid and was determined spectrophotometrically as its complex with Arsenazo III. Hafnium was not extracted under these conditions, but from the residual aqueous phase it was extracted with 7.0 × 10?2 M dicyclohexyl-18-crown-6 in dichloromethane from 9.0 M hydrochloric acid. It was stripped with 0.1 M perchloric acid and determined spectrophotometrically at 540 nm as its complex with xylenol orange. The separation of zirconium and hafnium from other metals is also described.  相似文献   

8.
Electrochemical reduction and determination of montelukast (MKS) was studied in methanol – 0.1 M HCl solution (1 : 1, v/v) by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at chitosan modified carbon paste electrode. The linear range was 1.70×10?7–1.83×10?5 M for DPV analysis. Limit of detection (LOD) and limit of quantification (LOQ) were 5.32×10?8 M and 1.61×10?7 M, respectively. The developed method was successfully applied to the determination of MKS in tablets and spiked human plasma. The results obtained were in good agreement with those obtained using a reported spectrofluorimetric technique.  相似文献   

9.
In this study, a Tosflex (a perfluoro‐anion‐exchange membrane) modified glassy carbon electrode has been used to detect 2‐naphthalenol (2‐naphthol) in aqueous solutions in order to demonstrate the electroanalytical application of Tosflex. 2‐naphthol polymerizes upon electrochemical oxidation at a glassy carbon electrode; however, the current related to this oxidation is too small for analytical purpose at low concentration level. A Tosflex polymer modified glassy carbon electrode (TFGCE) was found of having capability to improve the detection limit because 2‐naphthol molecules deprotonated in basic solutions to form 2‐naphtholate anions that were accumulated to TFGCE by the anion‐exchange characteristic of Tosflex. The accumulated 2‐naphtholate anions were determined with the following differential pulse voltammetry. With 3 minutes accumulation at +0.05 V, the dependence of oxidation current versus concentration was linear from 8×10?7 M to 1×10?5 M with a regression coefficient of 0.999 and a detection limit of 2×10?7 M. Unlike many other anion‐exchange polymer modified electrodes, the TFGCE is stable at highly basic condition.  相似文献   

10.
《Analytical letters》2012,45(12):1913-1931
Abstract

A voltammetric study of the oxidation of fexofenadine HCl (FEXO) has been carried out at the glassy carbon electrode. The electrochemical oxidation of FEXO was investigated by cyclic, linear sweep, differential pulse (DPV), and square wave (SWV) voltammetry using glassy carbon electrode. The oxidation of FEXO was irreversible and exhibited diffusion‐controlled process depending on pH. The dependence of intensities of currents and potentials on pH, concentration, scan rate, nature of the buffer was investigated. Different parameters were tested to optimize the conditions for the determination of FEXO. For analytical purposes, a very well resolved diffusion‐controlled voltammetric peak was obtained in Britton‐Robinson buffer at pH 7.0 with 20% constant amount of methanol for DPV and SWV techniques. The linear response was obtained in supporting electrolyte in the ranges of 1.0×10?6–2.0×10?4 M with a detection limit of 6.6×10?9 M and 5.76×10?8 M and in serum samples in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 8.08×10?8 M and 4.97×10?8 M for differential pulse and square wave voltammetric techniques, respectively. Only square wave voltammetric technique can be applied to the urine samples, and the linearity was obtained in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 2.00×10?7 M. Based on this study, simple, rapid, selective and sensitive two voltammetric methods were developed for the determination of FEXO in dosage forms and biological fluids. For the precision and accuracy of the developed methods, recovery studies were used. The standard addition method was used for the recovery studies. No electroactive interferences were found in biological fluids from the endogenous substances and additives present in tablets.  相似文献   

11.
《Analytical letters》2012,45(12):1869-1885
Abstract

A glassy carbon electrode surface was modified with an electropolymerized film made of pyrrole and β‐cyclodextrin 1∶1, in a 0.1 M LiClO4 solution using cyclic voltammetry. The resulting modified electrode (Ppy/β‐CD) exhibits interesting electrocatalytic activity toward the electrochemical oxidation of neurotransmitters such as dopamine (DA) and norepinephrine (NE). Well‐resolved and reversible cyclic voltammograms (CVs) were obtained for these organic compounds in a 0.1 M H2SO4 solution. The effect of the pH on the voltammetric response of DA and NE was also investigated inside the range of pH 2.8–8.4. The oxidation current of norepinephrine increase linearly with the concentration inside the range of 4×10?7 M–2×10?6 M. The oxidation current of dopamine also followed the same trend range of 2×10?6 M–10?5 M. The detection limit was 6×10?6 M for (DA) and 8×10?7 M for (NE). As an example, the relative standard deviation for 1×10?5 M of DA was 2.056%. The diffusion coefficients D for the molecules studied were determined by means of the measurement of the effect of the scan rate on the CVs of the neurotransmitters. All the results showed that the electron transfer was predominantly diffusion controlled at the conducting polymer/solution interface.

Interference phenomenon due to ascorbic acid (AA) toward the neurotransmitters was also investigated. The novel modified electrodes presented capability to resolve perfectly the AA and neurotransmitters oxidation peaks. This performance could be achieved even at a concentration 20 times higher than the neurotransmitters.

Finally, the newly fabricated Ppy/β‐CD film exhibits interesting analytical performances compared with other systems in the literature, such as higher sensitivity, rapid response, good mechanical stability and reproducibility.  相似文献   

12.
The nitrite-selective PVC membrane electrodes prepared with lipophilic long-chain tetraalkyltin compounds as neutral carrier show selectivity patterns significantly different from those obtained with classical anion-exchangers. The potentiometric selectivity coefficient for nitrite ion with respect to nitrate ion has been improved by about four orders of magnitude. The linear response range of the electrode based on tetralauryltin (TLT) is from 1 × 10?1M down to 2×10?5M with a detection limit of 5 × 10?6M. The Nernstian response of the electrode in the medium of pH≥7 gradually changes to a doubled super-Nernstian response when the solution turns slightly acidic. The change of the response slope has a closely relation with the stepwise complex-formation equilibrium of the carrier with the anion involved, which was experimentally studied by using ultraviolet spectroscopy. An explanation of the anomalous response behavior as well as the curve form of the potential-pH plot is given.  相似文献   

13.
《Electroanalysis》2005,17(19):1740-1745
A p‐chloranil modified carbon paste electrode was constructed and the electrochemical behavior of this electrode was studied in the aqueous solution with different pH. From the E1/2–pH diagram for this compound the values of formal potential E0' and pKa of some different redox and acid‐base couples depending on the solution pH were estimated. The diffusion coefficient, D, value for p‐chloranil was estimated 1.5×10?7 cm2 s?1. It has been shown by direct current cyclic voltammetry and double potential step chronoamperometry, that this p‐chloranil incorporated carbon paste electrode, can catalyze the oxidation of ascorbic acid in the aqueous buffered solution. Under the optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 325 mV less positive than that at an unmodified carbon past electrode. The catalytic oxidation peak currents was linearly dependent on the ascorbic acid concentration and a linear calibration curve was obtained in the range of 7×10?5 M–4×10?3 M of ascorbic acid with a correlation coefficient of 0.9998. The limit of detection (3σ) was determined as 3.5×10 ?5 M. This method was used as simple, selective and precise voltammetric method for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

14.
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of sodium humate(NaA). Palladium(II) was selectively accumulated in a solution of Britton-Robinson(B-R) buffer (pH 2.8) onto the electrode surface in open circuit mode. The subsequent electrochemical measurement was carried out by cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) in a supporting electrolyte of 1.0 M HCl. The obtained oxidation currents (Ipa1 and Lpa2) were proportional to the Pd(II) concentration in the range of 4.7 × 10–6 - 9.4 × 10–8 M. The developed method was applied to the quantitative determination of palladium in real samples.  相似文献   

15.
The chemical and electrochemical properties of technetium metal were studied in 1–6 M HX and in 1 M NaX (pH 1 and 2.5), X = Cl, NO3. The chemical dissolution rates of Tc metal were higher in HNO3 than in HCl (i.e. 8.63 × 10?5 mol cm?2 h?1 in 6 M HNO3 versus 2.05 × 10?9 mol cm?2 h?1 in 6 M HCl). The electrochemical dissolution rates in HNO3 and HCl were similar and mainly depended on the electrochemical potential and the acid concentration. The optimum dissolution of Tc metal was obtained in 1 M HNO3 at 1 V/AgAgCl (1.70 × 10?3 mol cm?2 h?1). The dissolution potentials of Tc metal in nitric acid were in the range of 0.596–0.832 V/AgAgCl. Comparison of Tc behavior with Mo and Ru indicated that in HNO3, the dissolution rate followed the order: Mo > Tc > Ru, and for dissolution potential the order: E diss(Ru) > E diss(Tc) > E diss(Mo). The corrosion products of Tc metal were analyzed in HCl solution by UV–Visible spectroscopy and showed the presence of TcO4 ?. The surface of the electrode was characterized by microscopic techniques; it indicated that Tc metal preferentially corroded at the scratches formed during the polishing and no oxide layer was observed.  相似文献   

16.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

17.
《Analytical letters》2012,45(6):1057-1070
ABSTRACT

A series piezoelectric quartz crystal (SPQC) sensor has been applied to detect L-glutamic acid and L-lysine acid. The effect of formaldehyde solution on the frequency shift was studied. Two methods were discussed. For the calibration curve method, in a neutralized formaldehyde medium, the linear ranges for determining L-glutamic acid and L-lysine acid were from 7.1×10?6M to 6.5×10?4M and from 6.9×10?6 M to 7.4×10?4 M, respectively, with the detection limit being 7.1×10?6 M and 6.9×10?6 M, the recoveries were 99.2% and 100.1%, the R.S.D were 1.63% (n=6) and 1.83%(n=6), respectively. Frequencimetric tiration method was also described and the lowest titratable concentrations were 8.3×10?5M and 5.5×10?5 M, respectively.  相似文献   

18.
The inhibition behavior of 6-methyl-4,5-dihydropyridazin-3(2H)-one (MDP) on corrosion of mild steel in 1 M HCl and 0.5 M H2SO4 was investigated using weight loss, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) measurements. The results indicated that the corrosion inhibition efficiency depends on concentration, immersion time, solution temperature, and the nature of the acidic solutions. It is also noted that MDP is at its the most efficient in 1 M HCl and least in 0.5 M H2SO4. The effect is more pronounced with MDP concentration. It is found that the inhibition efficiency attains 98 % at 5 × 10?3 M in 1 M HCl and 75 % at 5 × 10?2 in 0.5 M H2SO4. Polarization measurements showed that the MDP acts as a mixed inhibitor. EIS diagrams showed that the adsorption of MDP increases the transfer resistance and decreases the capacitance of the interface metal/solution. From the temperature studies, the activation energies in the presence of MDP were found to be superior to those in uninhibited medium. Finally, a mechanism for the adsorption of MDP was proposed and discussed.  相似文献   

19.
The mixed‐valent nickel hexacyanoferrate (NiHCF) and poly(3,4‐ethylenedioxythiophene) (PEDOT) hybrid film (NiHCF‐PEDOT) was prepared on a glassy carbon electrode (GCE) by multiple scan cyclic voltammetry. The films were characterized using atomic force microscopy, field emission scanning electron microscopy, energy dispersive spectroscopy, X‐ray diffraction, and electrochemical impedance spectroscopy (AC impedance). The advantages of these films were demonstrated for the detection of ascorbic acid (AA) using cyclic voltammetry and amperometric techniques. The electrocatalytic oxidation of AA at different electrode surfaces, such as the bare GCE, the NiHCF/GCE, and the NiHCF‐PEDOT/GCE modified electrodes, was determined in phosphate buffer solution (pH 7). The AA electrochemical sensor exhibited a linear response from 5×10−6 to 1.5×10−4 M (R2=0.9973) and from 1.55×10−4 to 3×10−4 M (R2=0.9983), detection limit=1×10−6 M, with a fast response time (3 s) for AA determination. In addition, the NiHCF‐PEDOT/GCE was advantageous in terms of its simple preparation, specificity, stability and reproducibility.  相似文献   

20.
A sensitive and selective electrochemical method for the determination of dopamine (DA) was developed using a 4‐(2‐Pyridylazo)‐Resorcinol (PAR) polymer film modified glassy carbon electrode (GCE). The PAR polymer film modified electrode shows excellent electrocatalytic activity toward the oxidation of DA in a phosphate buffer solution (PBS) (pH 4.0). The linear range of 5.0×10?6–3.0×10?5 M and detection limit of 2.0×10?7 M were observed. Simultaneous detection of AA, DA and UA has also been demonstrated on the modified electrode. This work provides a simple and easy approach to selective detection of DA in the presence of AA and UA.  相似文献   