首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new method is proposed for simultaneous determination of traces of arsenic (As) and selenium (Se) in biological samples by hydride-generation double-channel non-dispersive atomic-fluorescence spectrometry (HG-AFS) from tartaric acid media. The effects of analytical conditions on fluorescence signal intensity were investigated and optimized. Interferences from coexisting ions were evaluated. Under optimum conditions linear response ranges above 20 g L–1 for As and 32 g L–1 for Se were obtained with detection limits of 0.13 and 0.12 g L–1, respectively. The precision for elevenfold determination of As at the 4 g L–1 level and of Se at the 8 g L–1 level were 2.7 and 1.9% (RSD), respectively. Recoveries of 92.5–95.5% for As and 101.2–108.4% for Se were obtained for four biological samples and two certified biological reference materials. The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for simultaneous determination of As and Se in biological samples.  相似文献   

2.
A selective and sensitive method for the extraction and microgram determination of molybdenum (VI) with hydroxamic acid as yellow molybdenum-hydroxamate complex from acidic medium is described. The molybdenum-PCPPSAHA complex has max 388 nm, molar absorptivity 5.0 × 103l mol–1 cm–1. The system obeys Beer's law in the range of 1–28 g/ml of molybdenum(VI). Sandell's sensitivity is 0.0192 g cm2 and stoichiometry of the complex is 12, molybdenum: PCPPSAHA while mixed complex molybdenum-PCPPSAHA-morin has max 400 nm and molar absorptivity 5.9 × 103lmo1–1 cm–1 and stoichiometry of the complex is 121.The molybdenum is determined by graphite furnace atomic absorption spectrophotometry after directly pipetted the extract into the furnace which increases the sensitivity 20 fold.  相似文献   

3.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

4.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

5.
Summary The high activity of the radionuclides 65Ni (t1/2=2.52 h) and 58Co (t1/2=70.8 d) imposes severe limitations on the performance of direct instrumental neutron activation analysis of nickel. The extent of the interference of the 58Co depends on the ratio of the fluxes of the fast and thermal neutrons. A method of selective removal of cobalt, based on extraction with -nitroso--naphthol has been developed for the purpose of radiochemical NAA. Separation yields have been determined for 36 elements. The detection limits obtainable with both the instrumental and the radiochemical method are <10–4 g/g for the elements Au, Eu, Ir, La, Sc and Sm, between 10–4 and 10–3 g/g for Cr, Cs, Hf, Hg, Lu, Re, Sb, Ta, Th, Tm and Yb, between 10–3 and 10–2 g/g for As, Ag, Br, Ce, Ga, Na, Ru, Se, W and Zn, and in the range 0.01–1 g/g for Ba, Cd, Co, Fe, In, K, Mo, Nd, Pd, Rb, Sn, U and Zr.  相似文献   

6.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

7.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

8.
    
Summary Optimum for the generation of arsine from As(III) and (V) in a generating system without carrier gas and with atomization in an air-acetylene flame were established. A 3% solution of NaBH4 was used as reducer. The effect of 26 different species on the determination of arsenic was studied. The method has been applied to determine arsenic in copper.A linear relationship exists between 0.5 and 3 g for As(III) and between 1 and 4 total g of As(V). The sensitivity, expressed as the slope of the calibration curve is 0.067 g–1 for As(III) and 0.054 g–1 for As(V); the characteristic masses are 1.22 g and 0.44 g, and the limits of detection 0.27 g and 0.33 g, respectively.
Direkte Flammen-AAS — Erzeugung flüchtiger kovalenter HydrideStörungen durch das Verhältnis der As(III/V)-Valenzstufen und Arsenbestimmung in Kupfer
Zusammenfassung Optimale Bedingungen wurden ausgearbeitet für die Arsinerzeugung aus As(III) und As(V) in einem System ohne Trägergas mit Atomisierung in einer Luft-Acetylen-Flamme. Zur Reduktion dient eine 3%ige NaBH4-Lösung. Der Einfluß von 26 Fremdionen wurde geprüft und das Verfahren zur Arsenbestimmung in Kupfer angewendet. Eine lineare Beziehung ergab sich für 0,5–3 g As(III) und 1–4 g As(V). Die Empfindlichkeit (als Neigung der Eichkurve) beträgt 0,067 g–1 für As(III) und 0,054 g–1 für As(V). Die charakteristischen Massen sind 1,22 g bzw. 0,44 g und die Nachweisgrenzen 0,27 g bzw. 0,33 g.


This work has been sponsored by the CAICYT (project 3378/83) of the Spanish Education and Science Department.  相似文献   

9.
Kinetic equations were formulated, which describe coagulation–fragmentation process in a low concentrated suspension flow at a low shear rate. In such a system dispersed phase divided into fine and coarse fractions as the system is brought to equilibrium. Kinetic equations of two-fraction model were formulated. An approximate solution and, in one particular case, the exact solution of these equations were obtained for the equilibrium state. Detailed analysis of equilibrium particle distribution over the mass m was performed for an exponential coagulation kernel = 0 m and an degenerated disintegration kernel = 12, in which the disintegration frequency is an exponential function of aggregate mass 1 = 0 m + , and the probability of the fragment detachment from an aggregate is independent ofm and decreases exponentially with an increase in mass of a fragment: 2 = 0 –1exp(–/0). The equilibrium distribution was shown to exist only at > 0, and in particular, it is described at = = 1 by the f() = 00 –1exp(–/0) and F(m) = Cx –1(x + 1)2 – 1 e x functions for the particles of fine and coarse fractions (x = m/m 0, = m 0/0, m 0 and 0 are the characteristic masses of coarse and fine fractions, respectively). The particle distribution for the fine fraction at 1 is well approximated by the Gaussian distribution exp[–(mm 0)2/(4–1 m 00)].  相似文献   

10.
Summary HPLC procedures for analyses of the fusariotoxins zearalenone and vomitoxin in individual food- and feedstuffs as well as in mixed feed are described. Zearalenone is separated on a column with polar stationary phase (25 cm × 4.6 mm i.d., particle size 7 m), eluted with a chloroform-isooctane (75/25, v/v)+1.5% methanol mixture and detected fluorometrically. The quantitative determination was possible in all analyzed samples with a detection limit of 2g/kg with 70–80% recovery. Vomitoxin is fractionated by HPLC (C 18 1 column, 25 cm×4 mm i.d., 5 m particle size) with water-methanol (60/40, v/v) mobile phase and determined by combining GLC or TLC with UV detection. The detection limit in mixed feed with interfering substances was 25 g/kg (recovery 25–35%). The separation by HPLC makes preparation of pure vomitoxin possible. The described methods are fast, simple and low cost and are suitable for routine analyses.  相似文献   

11.
    
Zusammenfassung Es werden Erfahrungen mit der Kombination von automatischem Aminosäurenanalysator und Szintillations-Durchflußzelle zur Bestimmung der spezifischen Radioaktivität 14C-markierter Aminosäuren im Gehirn mitgeteilt. Die Erfassungsgrenze beträgt 3 · 10–4 Ci/ml Eluat, die Reproduzierbarkeit 5–1% vom Mittelwert im Meßbereich von 1 · 10–3 bis 5 · 10–2 Ci.
A method for the determination of the specific radioactivity of free amino-acids in tissue extracts of mammals
Some experiences are given with a measuring device for the determination of the specific radioactivity of 14C-labelled brain amino-acids. The apparatus consists of an automatic amino-acid analyzer combined with a flow cell filled with anthracene. The reproducibility of the method is ±5% to ±1% m.e. in the range of 1×10–3 Ci to 5×10–2 Ci. A quantitative determination of 3×10–4 Ci/ml eluant is still possible.
  相似文献   

12.
Some modifications of the stannous chloride reduction method for the estimation of inorganic phosphate reported by Berenblum-Chain are suggested. By this method, it is possible to measure 25 g l–1 of phosphorus /P/ as inorganic phosphate in the presence of macromolecules like deoxyribonucleic acid /100 g ml–1/, as compared to 200 g l–1 of P by the original method. If a larger sample volume /30 ml/ is used, even 5 g l–1 of P can be measured.  相似文献   

13.
A simple, sensitive and selective method for the extraction and trace determination of molybdenum(VI) has been developed; it is based on its reaction with 3-hydroxy-2-(2-thienyl)-4H-chromen-4-one (HTC) in sulphuric acid medium. The 1:2 Mo (VI)-HTC yellow complex is quantitatively extractable into chloroform (max 420 nm) and is stable for more than 4 h. The procedure eliminates the interference of a large number of metal ions and complexing agents. Beer's law is obeyed in the range of 0–2.85 g Mo/mL with a molar absorptivity, Sandell's sensitivity and standard deviation of 5.28×104 L mol–1 cm–1, 0.0018 g Mo/cm2 and ±0.0054, respectively. The method has successfully been used for the spectrophotometric determination of molybdenum in steel samples.  相似文献   

14.
Cerium can be determined spectrofluorimetrically (em 350 nm, ex 260 nm) based on the relatively intense native fluorescence of the cerium(III) aquo-ion. The main potential interference in the analysis of steel from iron(III), cerium(IV) and chromium(VI) are removed by use of a carrier solution containing 2.5% w/v hydroxylammonium chloride. The slight residual interference from iron(II) can be corrected by a matrix matching factor linearly related to the amount of iron present. The calibration graphs are linear over the range 0–7 g ml–1 based on 250 l injection volumes. The sampling rate was 30 h–1. The relative standard deviation was 2.0% (n=5) at 3 g ml–1 cerium. The system has been applied to the determination of cerium in carbon or low alloy steels.  相似文献   

15.
Summary For the trace determination of sodium alkylbenzenesulphonate (ABS) by HPLC the following conditions were employed: Shimadzu ZORBAX SIL Column (5 m, 4.6 mm i.d. x 150 mm) as stationary phase, 0.2% ammoniaethanol (v/v) as mobile phase, UV detector at 225 nm, injection volume 12 l. The chromatograms of ABS were simple and sharp (detection limit of ABS 0.02 g in 12 l of ethanol). The calibration curves of ABS were linear in a concentration range of 0.03 0.3 g in 12 l of ethanol. In the case of linear sodium dodecylbenzenesulphonate positive errors of 1 4% were caused by non-ionic surfactants or laurylsulphate (6 times excess), 10 50% positive errors were caused by 2 6 times excess of household detergents.Standard water samples containing ABS were treated with a weak base anion-exchange resin, the adsorbed ABS were eluted, and then determined either by HPLC or by the methylene blue spectrophotometric method. Recoveries of ABS in water were about 92 107% by HPLC.
Bestimmung von Spuren Natriumalkylbenzolsulfonat mit Hilfe der HPLC. Anwendung auf Wasser
Zusammenfassung Für die Spurenbestimmung von Natriumalkylbenzolsulfonat (ABS) durch HPLC werden die folgenden Bedingungen empfohlen:Shimadzu ZORBAX SIL (5 m, 4,6 mm x 150 mm) als stationäre Phase, 0,2% Ammoniak/Ethanol als mobile Phase, UV-Detektor bei 225 nm, Injektionsvolumen 12 l. Die erhaltenen Chromatogramme sind einfach und scharf (Nachweisgrenze 0,02 g in 12 ml Ethanol). Die Eichkurven sind im Konzentrationsbereich von 0,03–0,3 g in 12 l Ethanol linear. Im Falle des linearen Natriumdodecylbenzolsulfonats werden bei Anwesenheit von nicht-ionischen oberflächenaktiven Substanzen oder von Laurylsulfat in 6fachem Überschuß positiver Fehler von 1–4% erhalten; bei 2–6fachem Überschuß von Haushaltswaschmitteln ergeben sich positive Fehler von 10–50%.Standard-Wasserproben werden zunächst einer Behandlung mit einem Anionenaustauscher unterzogen, die adsorbierten ABS eluiert und durch HPLC oder nach der Methylenblaumethode analysiert. Wiederfindungsraten liegen bei 92–107%.
  相似文献   

16.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

17.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

18.
A rapid high-performance liquid chromatography (HPLC) method using a monolithic column with UV detection at 238 nm was developed for the determination of fenpropathrin, betacyfluthrin, deltamethrin, and permethrin (cis and trans isomers) in whole urine. The method is based on the use of a monolithic chromatographic column and a restricted access material (RAM) cartridge for sample preparation. The mobile phase was water/acetonitrile (42:58 v/v), the flow rate was 3 mL min–1, and chromatographic separation was carried out in 10 min. The separation of cis and trans isomers of permethrin was also possible under the above-mentioned conditions. Detection limits in reconstituted whole urine samples were between 0.9 g L–1 for betacyfluthrin and 4.4 g L–1 for fenpropathrin and trans-permethrin. Recoveries for urine samples spiked with different amounts of pyrethroids (between 19 g L–1 and 75 g L–1) were in the 70±6 to 90±7% range.  相似文献   

19.
Packed-column supercritical-fluid chromatography (pSFC) is presented as a novel method for separating and analyzing gramicidin samples. By use of methanol-modified carbon dioxide as a mobile phase the pentadecapeptides gramicidin A (gA), gramicidin B (gB), and gramicidin C (gC) are readily separated and eluted from a PRP-1 poly(styrene–divinylbenzene) column. Although optimum separation conditions are typically achieved near a column temperature of 40°C, a column pressure of 11 MPa, and 30% methanol modifier, pressure and modifier gradients around these values are also found to improve the overall separation time. Measurements indicate that the mobile phase solubility of gramicidin under these conditions is 5.0±0.4 g mL–1. Collection of individual peaks during chromatography achieved analytical-scale isolation of 2 g refined gC from 20 g injected gramicidin D. Further, supercritical-fluid extraction of 200 g gramicidin D from a Chromosorb 102 support packed into the vessel produced 57 g gA in 90% purity. The results establish that carbon dioxide-based mobile phases can be successfully used for the separation of individual gramicidin species.  相似文献   

20.
The cleavage of the di--hydroxo bridges of [Co(nta)(-OH)]2 2– by dimethylaminopyridine (dmap) and pyridine (py) has been investigated. [Co(nta)(-OH)]2 2– equilibrates rapidly in aqueous basic solutions with a mono--hydroxo bridged CoIII species [pK OH = 3.26(2)] and both these species react with the incoming ligand to form different ion associated species which react in the subsequent rate-determining steps (k 1 and k 2) to form presumably a ligand-substituted, mono-bridged species, [(nta)(OH)Co--OH-Co(nta)(L)]2–. Values for k 2, the preferred mono--hydroxo bridged substitution pathway for these reactions, vary between 6.8(2) × 10–4 s–1 (py) and 8.5(4) × 10–2 s–1 (dmap).  相似文献   