1.
The separation of anionic, cationic and neutral drugs in microemulsion electrokinetic chromatography (MEEKC) was studied with a statistical experimental design. The concentration of sodium dodecyl sulfate (SDS, surfactant), 1-butanol (co-surfactant) and borate buffer and the factors Brij 35 (surfactant), 2-propanol (organic solvent) and cassette temperature were varied simultaneously, while the parameters pH (9.2), the concentration of octane (oil, 0.8% w/w), the voltage (10 kV) and the dimension of the fused-silica capillary, were kept constant. Eight different model substances were chosen with different hydrophobicities. Two of the analytes were positively charged, two were negatively charged, and the remaining four were neutral or close to neutral at the pH explored. The importance of each parameter on the separation window, the plate height and the retention factor for each of the analytes was studied by means of multiple linear regression (MLR) models. A new response was evaluated for anions, the quotient between the effective mobility in the microemulsion and the effective mobility in the corresponding buffer. Factors affecting selectivity changes were also explored, and it was found that SDS and 2-propanol had the largest effect on selectivity.  相似文献   

2.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some UV filters (Eusolex 4360, Eusolex 6300, Eusolex OCR, Eusolex 2292, Eusolex 6007, Eusolex 9020, Eusolex HMS, Eusolex OS, and Eusolex 232) commonly found in suntan lotions. The composition of the microemulsion employed was optimized with respect to the best possible separation of the selected analytes using artificial neural networks (ANNs). Two parameters namely the composition of the mixed surfactant system comprising the anionic sodium dodecyl sulfate (SDS) and neutral Brij 35 and the amount of organic modifier (2-propanol) present in the aqueous phase of the microemulsion were modeled. Using an optimized MEEKC buffer consisting of 2.25 g SDS, 0.75 g Brij 35, 6.6 g 1-butanol, 0.8 g n-octane, 17.5 g 2-propanol, and 72.1 g of 10 mM borate buffer (pH 9.2), eight target analytes could be separated in under 25 min employing a diode-array detector to segregate the overlapping signals obtained for Eusolex 9020 and Eusolex HMS. Detection limits from 0.8 to 6.0 nug/mL were obtained and the calibration plots were linear over at least one order of magnitude. The optimized method could be applied to the determination of Eusolex 6300 and Eusolex 9020 in a commercial suntan lotion.  相似文献   

3.
A microemulsion electrokinetic chromatographic (MEEKC) method was developed for the separation of six catechins, specific marker phytochemicals of Cistus species. The MEEKC method involved the use of sodium dodecyl sulfate (SDS) as surfactant, heptane as organic solvent and butan-1-ol as co-solvent. In order to have a better stability of the studied catechins, the separation was performed under acidic conditions (pH 2.5 phosphate buffer). The effects of SDS concentration and of the amount of organic solvent and co-solvent on the analyte resolution were evaluated. The optimized conditions (heptane 1.36% (w/v), SDS 2.31% (w/v), butan-1-ol 9.72% (w/v) and 50 mM sodium phosphate buffer (pH 2.5) 86.61% (w/v)) allowed a useful and reproducible separation of the studied analytes to be achieved. These conditions provided a different separation profile compared to that obtained under conventional micellar electrokinetic chromatography (MECK) using SDS. The method was validated and applied to the determination of catechin and gallocatechin in lyophilized extracts of Cistus incanus and Cistus monspeliensis.  相似文献   

4.
The separation of neutral hydrophobic corticosteroids (cortisone, cortisone acetate, hydrocortisone, hydrocortisone acetate, prednisolone and prednisolone acetate) by microemulsion electrokinetic chromatography (MEEKC) was studied. In the preparation of microemulsion, heptane was the solvent, n-butanol the co-surfactant and, as anionic surfactants, sodium dodecyl sulfate (SDS) or taurodeoxycholic acid sodium salt (STDC) were employed. Using an acidic running buffer, (phosphate pH 2.5) a strong suppression of the electroosmotic flow (EOF) was observed; this resulted in a fast anodic migration of the analytes partitioned into the negatively charged microemulsion droplets. Under these conditions, STDC showed better separation of corticosteroids than the conventional SDS; however, the use of a single anionic surfactant did not provide the required selectivity. The addition of the neutral surfactant polyoxyethylene glycol octadecyl ether (Brij 76) significantly altered the migration of each analytes allowing a better tuning of separation; however, in order to obtain adequate resolution between couples of adjacent critical peaks, the addition of neutral cyclodextrins (CDs) was found to be essential. This apparently complex system (CD-MEEKC), was optimized by studying the effect of the most important parameters affecting separation: STDC concentration, Brij 76 concentration, nature and concentration of cyclodextrins. Following a rational step-by-step approach, the optimised conditions providing the complete separation of the analytes were found to be: 4.0% STDC, 2.5% Brij 76, 6.6% n-butanol, 1.36% heptane and 85.54% of a solution 5 mM beta-CD in 50 mM phosphate buffer (pH 2.5). The optimized system was preliminary applied to the detection of corticosteroids related substances at impurity level and it could be considered a useful orthogonal alternative to HPLC methods.  相似文献   

5.
Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some UV filters (Eusolex 4360, Eusolex 6300, Eusolex OCR, Eusolex 2292, Eusolex 6007, Eusolex 9020, Eusolex HMS, Eusolex OS, and Eusolex 232) commonly used in sunscreen lotions. Use of a MEEKC buffer with a mixed surfactant system to stabilize the oil droplets and an organic modifier in the aqueous phase allowed separation of most of the selected analytes in a single run in a system fitted with a diode array detector recording three wavelengths (240 nm, 300 nm, and 380 nm) simultaneously. The microemulsion employed consisted of 2.25 g of SDS, 0.75 g of Brij 35, 6.6 g 1‐butanol, 0.8 g n‐octane, 17.5 g 2‐propanol, and 72.1 g of 10 mM borate buffer (pH 9.2). Detection limits from 0.65 to 6.0 μg/mL were obtained and the calibration plots were linear over at least one order of magnitude for all analytes. The developed method could be applied to the determination of UV filters in several sun protection products including lotions, milks, and oils. Comparison of the obtained data with those from an HPLC method described in the literature showed acceptable agreement.  相似文献   

6.
建立了微乳液毛细管电动色谱同时分析消炎利胆片中穿心莲内酯和脱水穿心莲内酯的方法。考察了缓冲溶液的浓度、pH值、十二烷基硫酸钠(SDS)以及助表面活性剂的含量对分离测定的影响。在由乙酸乙酯-SDS-正丁醇-30 mmol/L硼砂缓冲液(pH 9.5)(质量比为0.5∶0.6∶6.0∶92.9)组成的微乳液体系中,两种内酯在6 min内完成分离。该法简便、快速、选择性好,用于实际样品中穿心莲内酯和脱水穿心莲内酯的分析,获得了满意的结果。  相似文献   

7.
A microemulsion electrokinetic chromatographic (MEEKC) method was developed for the separation of six catechins, specific marker phytochemicals of Cistus species. The MEEKC method involved the use of sodium dodecyl sulfate (SDS) as surfactant, heptane as organic solvent and butan-1-ol as co-solvent. In order to have a better stability of the studied catechins, the separation was performed under acidic conditions (pH 2.5 phosphate buffer). The effects of SDS concentration and of the amount of organic solvent and co-solvent on the analyte resolution were evaluated. The optimized conditions (heptane 1.36% (w/v), SDS 2.31% (w/v), butan-1-ol 9.72% (w/v) and 50 mM sodium phosphate buffer (pH 2.5) 86.61% (w/v)) allowed a useful and reproducible separation of the studied analytes to be achieved. These conditions provided a different separation profile compared to that obtained under conventional micellar electrokinetic chromatography (MECK) using SDS. The method was validated and applied to the determination of catechin and gallocatechin in lyophilized extracts of Cistus incanus and Cistus monspeliensis.  相似文献   

8.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(17):3349-3359
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters - six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring - were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle-like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n-heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1-butanol (cosurfactant), and 30% v/v 2-propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.  相似文献   

9.
A novel microemulsion electrokinetic chromatography (MEEKC) method for separating and determining two sesquoterpene lactones, alantolactone (AL) and isoalantolactone (IAL), in Radix inulae and Liuwei Anxian San has been developed. The effects of several important factors such as internal organic phases, concentration of microemulsion, concentration of acetonitrile, injection time and running voltage were systematically investigated to determine the optimum conditions. The optimum microemulsion system was composed of n-hexane (0.32% w/w), SDS (1.24% w/w), 1-butanol (2.64% w/w), acetonitrile (10% w/w) and 10 mm sodium tetraborate buffer (85.80% w/w, pH 9.2). The applied voltage was 20 kV. The analytes were detected at 214 nm. Regression equations revealed linear relationships (correlation coefficients 0.9950 for AL and 0.9946 for IAL) between the peak area of each analyte and the concentration. The limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 0.45 microg/mL for AL and 0.56 microg/mL for IAL. The levels of the analytes were successfully determined with recoveries ranging from 98.2 to 104.3%. Furthermore, a simple and effective extraction method, with methanol in an ultrasonic water bath for 60 min, was used for sample preparing. Also, MEEKC was compared with micellar electrokinetic chromatography (MEKC) and shown better separation results.  相似文献   

10.
Microemulsion electrokinetic chromatography (MEEKC) was carried out in a pH 2.5 phosphate buffer to effectively suppress the electroosmotic flow (EOF). With 66.6% (w/w) 25 mM phosphate buffer pH 2.5, 20.0% (w/w) 2-propanol, 6.6% (w/w) 1-butanol, 6.0% (w/w) sodium lauryl sulphate (SDS), and 0.8% (w/w) n-octane as the separation medium, the fat-soluble vitamins A palmitate, E acetate, and D3 were baseline separated within 11 min. With strongly suppressed EOF, the polarity of the separation voltage was reversed (positive electrode at the outlet); the n-octane micro droplets surrounded by negatively charged SDS molecules migrated towards the detector. The aqueous part of the microemulsion was modified with 20% (w/w) 2-propanol to improve partition between the n-octane phase and the surrounding aqueous medium. The fat-soluble vitamins were separated in order of decreasing hydrophobicity with a high migration time stability (repeatable within 0.1% RSD). Excellent accuracy and precision were obtained when the system was applied for the determination of vitamin E acetate in commercial vitamin tablets; quantitative data corresponded to 97.0% of label claim, intra-day results varied within 1.72% RSD (n=6), and inter-day results varied within 3.22% RSD (n=5).  相似文献   

11.
A simple solid phase extraction (SPE) method coupled with high performance liquid chromatography (HPLC) using UV detector and microemulsion electrokinetic chromatography (MEEKC) has been developed and compared for the quantitative determination of miconazole nitrate in pharmaceutical formulation. For HPLC method, two parameters were optimized, namely, the wavelength and the mobile phases. The optimized condition was at the 225 nm wavelength and the mobile phase of ACN:MeOH (90:10 v/v). There are seven MEEKC parameters that were optimized, in this research, which were applied to voltage, temperature, wavelength, sodium dodecyl sulfate (SDS) concentration, buffer pH, buffer concentration and butan-1-ol concentration. The optimum MEEKC condition was obtained using 86.35 % (w/w) 2.5 mM borate buffer pH 9, 0.25 % (w/w) SDS, 0.8 % (w/w) ethyl acetate, 6.6 % w/w butan-1-ol and 6.0 % (w/w) acetonitrile. The combination of SPE using a diol column with HPLC–UV and the MEEKC methods were successfully applied for the determination of miconazole nitrate in a pharmaceutical formulation with the recovery percentage of 98.35 and 92.50 %, respectively.  相似文献   

12.

A simple solid phase extraction (SPE) method coupled with high performance liquid chromatography (HPLC) using UV detector and microemulsion electrokinetic chromatography (MEEKC) has been developed and compared for the quantitative determination of miconazole nitrate in pharmaceutical formulation. For HPLC method, two parameters were optimized, namely, the wavelength and the mobile phases. The optimized condition was at the 225 nm wavelength and the mobile phase of ACN:MeOH (90:10 v/v). There are seven MEEKC parameters that were optimized, in this research, which were applied to voltage, temperature, wavelength, sodium dodecyl sulfate (SDS) concentration, buffer pH, buffer concentration and butan-1-ol concentration. The optimum MEEKC condition was obtained using 86.35 % (w/w) 2.5 mM borate buffer pH 9, 0.25 % (w/w) SDS, 0.8 % (w/w) ethyl acetate, 6.6 % w/w butan-1-ol and 6.0 % (w/w) acetonitrile. The combination of SPE using a diol column with HPLC–UV and the MEEKC methods were successfully applied for the determination of miconazole nitrate in a pharmaceutical formulation with the recovery percentage of 98.35 and 92.50 %, respectively.

  相似文献   

13.
A mixture of nine biphenyl nitrile compounds with high hydrophobicity and similar structures was successfully separated by microemulsion electrokinetic chromatography (MEEKC) within 30 rain. The buffer system contained 100 mmol/L sodium dodecyl sulfate (SDS), 80 mlnol/L sodium cholate (SC), 0.81% heptane, 7.5% n-butanol, 10% acetonitrile and 10 mmol/L borate. The addition of SC, organic modifiers, sample preparation and temperature all showedremarkable effect on the separation. Meanwhile, the MEEKC method was briefly compared with micellar electrokinetic chromatography (MEKC) method.  相似文献   

14.
Different forms of tocopherols, together with tocotrienols, are collectively named as vitamin E, and each possesses different degree of medical, biological and physiochemical significance. The main difficulty of separating different forms of tocopherols lay in their highly structural similarities and hydrophobicities. Microemulsion electrokinetic chromatography (MEEKC), claimed to attain high peak efficiency with great solubilization power, has not previously been applied to the separation of tocopherols. The effects that various parameters, such as buffer system, type and concentration of cyclodextrins, temperature, and sample matrix, have on the separation of tocopherols by MEEKC have been investigated. By using a buffer mixture of 4% (w/w) sodium dodecyl sulfate (SDS), 6.6% (w/w) 1-butanol, 0.8% (w/w) n-octane, 20% (w/w) 2-propanol, 68.6% (w/w) phosphate (25mM, pH 2.5), and 25mM heptakis(2,6-di-O-methyl)-beta-cyclodextrin (DM-beta-CD), the separation of alpha-, gamma-, and delta-tocopherol, alpha-tocopherol acetate, as well as the antioxidant butylated hydroxytoluene (BHT) at -26kV, 25 degrees C was completed within 35min. The practical potential of the present approach has been further validated by the determination of tocopherols in a vitamin E preparation, with the result of 132.63 (RSD 1.25%), 176.51 (RSD 0.29%), and 64.32mg (RSD 3.34%) per 500mg capsule for alpha-, gamma- and delta-tocopherol, respectively.  相似文献   

15.
The electrokinetic separation of the hydrophobic antimycotic drug itraconazole (ITC) and its major metabolite, hydroxyitraconazole (HITC), by a binary aqueous-organic solvent medium containing sodium dodecylsulfate, by microemulsion electrokinetic chromatography (MEEKC) and by micellar electrokinetic chromatography (MEKC) was studied. The results suggest that the first approach is difficult to apply and that there is no substantial difference between separations performed using MEEKC and MEKC modified with n-butanol. The simpler MEKC method is more than adequate and was thus employed for the analysis of ITC and HITC in human serum and plasma. Separation was achieved in plain fused-silica capillaries having a low-pH buffer (pH 2.2) with sodium dodecyl sulfate micelles and reversed polarity. The addition of 2-propanol and n-butanol enhanced analyte solubility and altered the selectivity of the separation by influencing the magnitude of the electrophoretic component in the separation mechanism. Under optimised conditions and using head-column field-amplified sample stacking, an internal standard, ITC and two forms of HITC could be separated in under 9 min, with detection limits less than 0.01 microg/mL. Analysis of samples from patients currently prescribed ITC revealed a different HITC peak area ratio to that of the standards, suggesting a stereoselective component of ITC metabolisation. Comparison of MEKC data with those of a HPLC method employed on a routine basis showed excellent agreement, indicating the potential of this approach for therapeutic drug monitoring of ITC.  相似文献   

16.
《Analytica chimica acta》2004,503(2):271-278
In this work, a capillary electrophoresis (CE) method for the determination of a group of eleven triazine compounds by micellar electrokinetic capillary chromatography (MEKC) with diode array detection was developed. The eleven herbicides studied were: desethylatrazin-2-hydroxy (DEA), simazine, prometon, atrazine, simetryn, ametryn, propazine, prometryn, trietazine, terbutylazine, and terbutryn The separation of these compounds was optimised as a function of buffer concentration and pH, concentration of sodium dodecyl sulphate (SDS) and voltage applied. To increase the selectivity of the separation and the resolution of the solutes, different organic solvents were tested as buffer additives, obtaining the best results when 1-propanol was used. The optimised buffer (24 mM of sodium borate, 18 mM of disodium hydrogen phosphate, 25 mM of SDS, pH 9.5, and 5% of 1-propanol) provides the best separation in terms of resolution and migration time. This method allowed the determination of these compounds at concentrations of 0.05 μg l−1 in ground water samples pretreated using solid-phase extraction (SPE).  相似文献   

17.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

18.
A micellar electrokinetic chromatography method was optimised for the separation of the six cardiovascular drugs atenolol, nicardipine, nifedipine, diltiazem, verapamil, and amlodipine by investigating the effects of pH, sodium dodecyl sulphate (SDS) concentration, selection and concentration of organic modifier. An electrophoresis buffer of 100 mM borate pH 8.1 containing 50 mM SDS and 15% (v/v) acetone was found to provide the optimum separation with respect to resolution and migration time.  相似文献   

19.
The separation and migration behavior of pyridine and eight chloropyridines, including three monochloropyridines, four dichloropyridines, and 2,3,5-trichloropyridine were investigated by micellar electrokinetic chromatography using either sodium dodecyl sulfate (SDS) as an anionic surfactant or SDS-Brij 35 mixed micelles. Various parameters such as buffer pH, SDS concentration, Brij 35 concentration and methanol content that affect the separation were optimized. Complete separation of these chloropyridines was optimally achieved with a phosphate buffer containing SDS (30 mM) and methanol (10%, v/v) at pH 7.0. The resolution and selectivity of analytes could be considerably affected by the addition of methanol and/or Brij 35 to the background electrolyte. The migration order of these chloropyridines depends primarily on their hydrophobicity. However, electrostatic interactions may also play a significant role in the determination of the migration order of the positional isomers of chloropyridines.  相似文献   

20.
Microemulsion electrokinetic capillary chromatography (MEEKC) is a capillary electrophoresis technique in which neutral and ionized species can be resolved according to their partitioning into moving oil droplets present in the operating buffer. In this report, we present for the first time the application of MEEKC in the analysis of glycosaminoglycans. An efficient method for the separation of the variously sulfated delta-disaccharides obtained following digestion of chondroitin and dermatan sulfates with chondro/ dermato lyases and derivatization with 2-aminoacridone is described. Nonsulfated, mono-, di-, and trisulfated delta-disaccharides were completely separated using the microemulsion octane/butan-1-ol/Sodium dodecyl sulfate (SDS) in 10 mM borate buffer, pH 9.3, at 25 kV. Agreement of the obtained disaccharide composition with literature values showed that MEEKC can be used for the analysis of glycosaminoglycans.  相似文献   