首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a simple method to change the hydrophilic nature of the glass surface in a poly(dimethylsiloxane) (PDMS)-glass hybrid microfluidic device to hydrophobic by an extra-heating step during the fabrication process. Glass substrates bonded to a native or oxygen plasma-treated PDMS chip having microchambers (12.5 mm diameter, 110 μm height) were heated at 200°C for 3 h, and then the hydrophobicity of the glass surfaces on the substrate was evaluated by measuring the contact angle of water. By the extra-heating process, the glass surfaces became hydrophobic, and its contact angle was around 109°, which is nearly the same as native PDMS surfaces. To demonstrate the usefulness of this surface modification method, a PDMS-glass hybrid microfluidic device equipped with microcapillary vent structures for pneumatic manipulation of droplets was fabricated. The feasibility of the microcapillary vent structures on the device with the hydrophobic glass surfaces are confirmed in practical use through leakage tests of the vent structures and liquid handling for the electrophoretic separation of DNA molecules.  相似文献   

2.
We report the development of a magnetically controlled drug delivery device for on-demand drug release to treat chronic diseases. The devices consist of drug-loaded micro-reservoirs (6 mm in diameter and ~550 μm in depth), sealed by magnetic PDMS (polydimethylsiloxane) membranes (? 6 mm × 40 μm) with laser-drilled apertures and actuated by an external magnetic field. We present a detailed analysis of the magnetic actuation forces and provide an estimate of the resulting membrane deflections. The reservoirs are fabricated by PDMS molding and loaded with drugs using solvent evaporation methods. Post-processing procedures using bovine serum albumin (BSA) adsorption on magnetic PDMS surfaces are carried out to modify the surface wettability and to allow water filling and dissolution of the drugs in the reservoirs. Detailed surface modification processes are described and characterized. The device demonstrates on-demand delivery of methylene blue (MB) as a model drug. Intermittent magnetic actuations of the device in a ~200 mT magnetic field show 10-fold increase in MB release compared to background release when the device is not actuated.  相似文献   

3.
A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 μW (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N=3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.  相似文献   

4.
This work describes a novel and cost-effective method of polydimethylsiloxane (PDMS) microchips fabrication by using a printing plate photopolymer called Flexcel as a master mold (Fmold). This method has demonstrated the ability to generate multiple devices from a single master, reaching a minimum channel size of 25 μm, structures height ranging from 53 to 1500 μm and achieving dimensions of 1270 × 2062 mm2, which are larger than those obtained by the known techniques to date. Scanning electron microscopy, atomic force microscopy, and profilometry techniques have been employed to characterize the Fmold and PDMS replicas. The results showed high replication fidelity of Fmold to the PDMS replica. Furthermore, it was proved the reusability of the Fmold. In our study, up to 50 PDMS replicas have been fabricated without apparent degradation of the mold. The feasibility of the resulting PDMS replica was effectively demonstrated using a microfluidic device for enhanced oil recovery analysis. © 2018 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2018 , 56, 1433–1442  相似文献   

5.
P Zellner  M Agah 《Electrophoresis》2012,33(16):2498-2507
Concentration of biological specimens that are extremely dilute in a solution is of paramount importance for their detection. Microfluidic chips based on insulator-based DEP (iDEP) have been used to selectively concentrate bacteria and viruses. iDEP biochips are currently fabricated with glass or polymer substrates to allow for high electric fields within the channels. Joule heating is a well-known problem in these substrates and can lead to decreased throughput and even device failure. In this work, we present, for the first time, highly efficient trapping and separation of particles in DC iDEP devices that are fabricated on silicon using a single-etch-step three-dimensional microfabrication process with greatly improved heat dissipation properties. Fabrication in silicon allows for greater heat dissipation for identical geometries and operating conditions. The 3D fabrication allows for higher performance at lower applied potentials. Thermal measurements were performed on both the presented silicon chips and previously published PDMS devices comprised of microposts. Trapping and separation of 1 and 2 μm polystyrene particles was demonstrated. These results demonstrate the feasibility of high-performance silicon iDEP devices for the next generation of sorting and concentration microsystems.  相似文献   

6.
We report the development of a magnetically controlled MEMS device capable of on-demand release of defined quantities of an antiproliferative drug, docetaxel (DTX). Controlled release of DTX with a dosage suitable for the treatment of diabetic retinopathy has been achieved for 35 days. The device consists of a drug-loaded microreservoir (?6 mm ×~550 μm), sealed by an elastic magnetic PDMS (polydimethylsiloxane) membrane (?6 mm × 40 μm) with a laser-drilled aperture (~100 × 100 μm(2)). By applying a magnetic field, the magnetic PDMS membrane deforms, causing the discharge of the drug solution from the device. Controlled DTX release at a rate of 171 ± 16.7 ng per actuation interval has been achieved for 35 days using a 255 mT magnetic field. The background leakage of drug solution through the aperture was negligible at 0.053 ± 0.014 ng min(-1). The biological activity of the released drug was investigated using a cytotoxicity assay (cell apoptosis) for two cell lines, HUVEC (human umbilical vein endothelial cells) and PC3 (prostate cancer) cells. Reproducible release rates have been achieved and DTX within the PDMS MEMS reservoir maintains full pharmacological efficacy for more than two months. This device is a proof-of-concept development for targeted delivery of hydrophobic drugs such as DTX and other taxane-based agents that require accurate delivery in nanomolar concentrations.  相似文献   

7.
In a single step photolithography, muhi-level microfluidic device is fabricated by printing novel architectures on a film photomasks. The whole fabrication process is executed by classical PCB technology without the need to access clean room facilities. Different levels of protruding features on PCB master are produced by exposing a photomask with specifically arranged "windows and rims" architectures, followed by chemical wet etching. Poly(dimethylsiloxane)(PDMS) is then molded against the positive relief master to generate microfluidic device featured with multi-level sandbag structure and peripheral microchannels. This sandbag structure is an analog to traditional dam or weir for particle entrapment. The microstructure does not collapse when subjected to applied pressure, which is suitable for operation on elastic PDMS substrate.Typical immunocytochemcial staining assays were performed in the microdevice to demonstrate the applicability of the sandbag structure for cellular analysis. This simplified microfabrication process employs low-cost materials and minimal specialized equipment and can reproducibly produce mask lines with about 20 μm in width, which is sufficient for most microfluidic applications.  相似文献   

8.
Araci IE  Quake SR 《Lab on a chip》2012,12(16):2803-2806
Microfluidic chips with a high density of control elements are required to improve device performance parameters, such as throughput, sensitivity and dynamic range. In order to realize robust and accessible high-density microfluidic chips, we have fabricated a monolithic PDMS valve architecture with three layers, replacing the commonly used two-layer design. The design is realized through multi-layer soft lithography techniques, making it low cost and easy to fabricate. By carefully determining the process conditions of PDMS, we have demonstrated that 8 × 8 and 6 × 6 μm(2) valve sizes can be operated at around 180 and 280 kPa differential pressure, respectively. We have shown that these valves can be fabricated at densities approaching 1 million valves per cm(2), substantially exceeding the current state of the art of microfluidic large-scale integration (mLSI) (thousands of valves per cm(2)). Because the density increase is greater than two orders of magnitude, we describe this technology as microfluidic very large scale integration (mVLSI), analogous to its electronic counterpart. We have captured and tracked fluorescent beads, and changed the electrical resistance of a fluidic channel by using these miniaturized valves in two different experiments, demonstrating that the valves are leakproof. We have also demonstrated that these valves can be addressed through multiplexing.  相似文献   

9.
液滴数字聚合酶链式反应芯片及其在致病菌检测中的应用   总被引:1,自引:0,他引:1  
设计与制作了一种基于聚二甲基硅氧烷-玻璃(PDMS-Glass)的多功能集成式液滴数字聚合酶链式反应(ddPCR)芯片,该芯片由产生液滴的PDMS模块和收集液滴的玻璃腔体模块组成。PDMS模块采用双通道的T形结构设计,液滴产生速度快且通量高,在30 min内可生成2×10~6个直径约为20μm的微液滴。玻璃腔体模块中存储的液滴在整个实验过程中无需转移,可直接在原位PCR仪上进行扩增,每个液滴均是一个微反应器,经过多次热循环后,液滴仍能保持良好的稳定性。选用副溶血性弧菌(VP)作为食源性致病菌的研究模型,考察了ddPCR芯片对其基因组DNA的绝对定量能力,结果表明,该ddPCR芯片对VP基因组DNA绝对定量的线性范围宽,可跨越5个数量级(10~1~10~6 copies/μL),定量结果与DNA理论参考浓度间有很好的相关性。  相似文献   

10.
Insulator‐based dielectrophoresis (iDEP) is a well‐known technique that harnesses electric fields for separating, moving, and trapping biological particle samples. Recent work has shown that utilizing DC‐biased AC electric fields can enhance the performance of iDEP devices. In this study, an iDEP device with 3D varying insulating structures analyzed in combination with DC biased AC fields is presented for the first time. Using our unique reactive ion etch lag, the mold for the 3D microfluidic chip is created with a photolithographic mask. The 3D iDEP devices, whose largest dimensions are 1 cm long, 0.18 cm wide, and 90 μm deep are then rapidly fabricated by curing a PDMS polymer in the glass mold. The 3D nature of the insulating microstructures allows for high trapping efficiency at potentials as low as 200 Vpp. In this work, separation of Escherichia coli from 1 μm beads and selective trapping of live Staphylococcus aureus cells from dead S. aureus cells is demonstrated. This is the first reported use of DC‐biased AC fields to selectively trap bacteria in 3D iDEP microfluidic device and to efficiently separate particles where selectivity of DC iDEP is limited.  相似文献   

11.
A screen-printed dissolved oxygen sensor was fabricated using cerium oxide-supported silver catalyst and polydimethylsiloxane (PDMS) film. A PDMS film of 3 μm thickness showed good permeability for oxygen and impermeability for hydrogen peroxide. The calibration curve has shown a linear relationship with a correlation coefficient of 0.996 for the dissolved oxygen concentration. The sensitivity and detection limit of the present sensor were calculated at -158 μA mM(-1) and 8.4 μM, respectively.  相似文献   

12.
This study develops a sheathless CE‐MS interface using a robust PDMS membrane emitter and liquid‐film electric conduction. A 3D mold was constructed for casting the device by using a one‐step casting procedure. The interface consisted of a 125 μm‐thick triangular emitter with a 50 μm‐diameter microchannel, a conducting reservoir, and a 375 μm‐diameter channel for assembling the separation capillary. The separation capillary was inserted into the 375 μm channel and connected to the emitter through the conducting reservoir. The electric contact for the CE outlet was established through a conductive liquid film in the space between the capillary terminus and the 375 μm channel. The one‐step casting procedure and using a membrane emitter instead of a tapered emitter produced an easily fabricated and robust interface. A stable electrospray was obtained from 30 to 350 nL/min. Analyzing a five‐peptide mixture in low‐EOF (60 nL/min) and high‐EOF (210 nL/min) conditions demonstrated the utility of the interface.  相似文献   

13.
Zhuang G  Jensen TG  Kutter JP 《Electrophoresis》2012,33(12):1715-1722
In this paper, we describe a microfluidic device composed of integrated microoptical elements and a two-layer microchannel structure for highly sensitive light scattering detection of micro/submicrometer-sized particles. In the two-layer microfluidic system, a sample flow stream is first constrained in the out-of-plane direction into a narrow sheet, and then focused in-plane into a small core region, obtaining on-chip three-dimensional (3D) hydrodynamic focusing. All the microoptical elements, including waveguides, microlens, and fiber-to-waveguide couplers, and the in-plane focusing channels are fabricated in one SU-8 layer by standard photolithography. The channels for out-of-plane focusing are made in a polydimethylsiloxane (PDMS) layer by a single cast using a SU-8 master. Numerical and experimental results indicate that the device can realize 3D hydrodynamic focusing reliably over a wide range of Reynolds numbers (0.5 < Re < 20). Polystyrene particles of three sizes (2, 1, and 0.5 μm) were measured in the microfluidic device with integrated optics, demonstrating the feasibility of this approach to detect particles in the low micrometer size range by light scattering detection.  相似文献   

14.
The desorption of atomic and molecular species from surfaces bombarded by fast heavy ions (Z ? 20; E ? 0.5 MeV/amu) is attractive for surface and microscopic characterization. Only a low-intensity probe beam is needed, the escape depth of desorbed species is shallow (ca. 10 Å), and desorbed ions are efficiently detected with a time-of-flight mass spectrometer. Thus, particle-induced desorption mass spectrometry (PDMS) maintains sample integrity and charging effects are avoided. PDMS is useful for surface analysis of glasses and plastics by using californium-252 fission fragments for bombardment. Inorganic and organic surface constituents can be detected simultaneously; mass resolution is good. For lithium in glass, the detection limit is about 1 pg (ca. 100 μg g?1. The PDMS technique can be combined with sequential ion etching for depth profiling. The feasibility of PDMS for microscopic analysis with a collimated 84-MeV Kr7+ beam (target diameter ca. 11 μm) is discussed.  相似文献   

15.
Chung BG  Lin F  Jeon NL 《Lab on a chip》2006,6(6):764-768
This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.  相似文献   

16.
Hwang KY  Kwon SH  Jung SO  Lim HK  Jung WJ  Park CS  Kim JH  Suh KY  Huh N 《Lab on a chip》2011,11(21):3649-3655
We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system.  相似文献   

17.
Multi-step temperature control in a polymerase chain reaction (PCR) is a limiting factor in device miniaturization and portability. In this study, we propose the fabrication of a three-dimensional (3D) microdevice employing a single heater to minimize temperature control required for an on-chip continuous-flow PCR as well as the overall footprint by stacking the device in multi-layers. Two poly(dimethylsiloxane) (PDMS) layers with differing thicknesses are vertically stacked with their microchannel-engraved sides facing down. Through-holes are made in the thicker PDMS layer, which is sandwiched between a glass substrate at the bottom and the thinner PDMS layer at the top. In this way, a fluidic conduit is realized in a 3D configuration. The assembled 3D microdevice is then placed onto a heater glass-side down. The interface of the two PDMS layers displays a relatively lower temperature than that of the PDMS and glass layers due to the low thermal conductivity of the PDMS and its physical distance from the heater. The denaturation temperature can be controlled by adjusting the temperature of the heater, while the annealing/extension temperature can be controlled automatically by molding the thicker bottom PDMS layer into the appropriate thickness calculated using a numerical derivation proposed in this study. In this way, a cumbersome temperature measurement step is eliminated. DNA amplification was successfully carried out using the proposed 3D fluidic microdevice, and the intensity of the resulting amplicon was comparable to that obtained using a thermal cycler. This novel concept of adopting a single heating source greatly simplifies the temperature control issue present in an on-chip continuous-flow PCR. It also allows the use of a commercialized hot plate as a potential heat source, paving the way for device miniaturization and portability in a highly cost-effective manner. In this study, a simple and facile technique to make arrays of through-holes for the fluidic interconnection inside a 3D channel configuration is also addressed.  相似文献   

18.
In this paper, we describe a simple method for fabrication of high quality poly(dimethylsiloxane) (PDMS)/glass microchip by twofold replica molding of PDMS. This technique first served to transfer the negative microchannels from the glass template to the PDMS substrate as a master, and then this PDMS master with positive microchannels was used to replicate the PDMS replica with negative microchannels. Finally, the PDMS replica was bound to a glass sheet by UV radiation. The fabricated microchips were successfully applied for the detection of C677T mutation from the human methylenetetrahydrofolate reductase gene.  相似文献   

19.
Yuen PK  Su H  Goral VN  Fink KA 《Lab on a chip》2011,11(8):1541-1544
This technical note presents a fabrication method and applications of three-dimensional (3D) interconnected microporous poly(dimethylsiloxane) (PDMS) microfluidic devices. Based on soft lithography, the microporous PDMS microfluidic devices were fabricated by molding a mixture of PDMS pre-polymer and sugar particles in a microstructured mold. After curing and demolding, the sugar particles were dissolved and washed away from the microstructured PDMS replica revealing 3D interconnected microporous structures. Other than introducing microporous structures into the PDMS replica, different sizes of sugar particles can be used to alter the surface wettability of the microporous PDMS replica. Oxygen plasma assisted bonding was used to enclose the microstructured microporous PDMS replica using a non-porous PDMS with inlet and outlet holes. A gas absorption reaction using carbon dioxide (CO(2)) gas acidified water was used to demonstrate the advantages and potential applications of the microporous PDMS microfluidic devices. We demonstrated that the acidification rate in the microporous PDMS microfluidic device was approximately 10 times faster than the non-porous PDMS microfluidic device under similar experimental conditions. The microporous PDMS microfluidic devices can also be used in cell culture applications where gas perfusion can improve cell survival and functions.  相似文献   

20.
We present a simple method for fabricating chemically-inert Teflon microfluidic valves and pumps in glass microfluidic devices. These structures are modeled after monolithic membrane valves and pumps that utilize a featureless polydimethylsiloxane (PDMS) membrane bonded between two etched glass wafers. The limited chemical compatibility of PDMS has necessitated research into alternative materials for microfluidic devices. Previous work has shown that spin-coated amorphous fluoropolymers and Teflon-fluoropolymer laminates can be fabricated and substituted for PDMS in monolithic membrane valves and pumps for space flight applications. However, the complex process for fabricating these spin-coated Teflon films and laminates may preclude their use in many research and manufacturing contexts. As an alternative, we show that commercially-available fluorinated ethylene-propylene (FEP) Teflon films can be used to fabricate chemically-inert monolithic membrane valves and pumps in glass microfluidic devices. The FEP Teflon valves and pumps presented here are simple to fabricate, function similarly to their PDMS counterparts, maintain their performance over extended use, and are resistant to virtually all chemicals. These structures should facilitate lab-on-a-chip research involving a vast array of chemistries that are incompatible with native PDMS microfluidic devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号