首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The hyphenation of capillary electrophoresis (CE) with mass spectrometry (MS) is a powerful method to obtain high efficient, sensitive, and selective analyses. The successful coupling with electrospray ionization (ESI) source requires closed electric circuits for both the CE separation and the ESI processes. A wide range of interfaces has been proposed to satisfy this requirement. Among them, the new high sensitivity porous sprayer based on a porous tip achieves the electric connection by inserting the capillary outlet made of a porous material into an ESI needle filled with a conductive liquid and independently grounded. This device is compatible with the minute flow rates exhibited in CE and therefore makes possible the use of a nano-electrospray behavior. In this work, this interface was evaluated for hyphenating a CE with a single quadrupole MS instrument for low molecular weight analytes. Investigations aimed at highlighting the most influent parameters thanks to a design of experiments, reaching the best performance in terms of sensitivity and stability. MS signal intensities of various pharmaceutical compounds (e.g. amphetamines, β-blockers) emphasized high sensitivity and efficiency, while repeatability, expressed as relative standard deviation of corrected heights and areas, was suitable for quantitative purposes (<5%).  相似文献   

2.
《Electrophoresis》2018,39(11):1382-1389
A sheath‐flow interface is the most common ionization technique in CE‐ESI‐MS. However, this interface dilutes the analytes with the sheath liquid and decreases the sensitivity. In this study, we developed a sheathless CE‐MS interface to improve sensitivity. The interface was fabricated by making a small crack approximately 2 cm from the end of a capillary column fixed on a plastic plate, and then covering the crack with a dialysis membrane to prevent metabolite loss during separation. A voltage for CE separation was applied between the capillary inlet and the buffer reservoir. Under optimum conditions, 52 cationic metabolite standards were separated and selectively detected using MS. With a pressure injection of 5 kPa for 15 s (ca. 1.4 nL), the detection limits for the tested compounds were between 0.06 and 1.7 μmol/L (S/N = 3). The method was applied to analysis of cationic metabolites extracted from a small number (12 000) of cancer cells, and the number of peaks detected was about 2.5 times higher than when using conventional sheath‐flow CE‐MS. Because the interface is easy to construct, it is cost‐effective and can be adapted to any commercially available capillaries. This method is a powerful new tool for highly sensitive CE‐MS‐based metabolomic analysis.  相似文献   

3.
A nonaqueous CE‐IT MS with a nanospray ionization interface method was developed for the identification and quantification of tetrandrine (TET), fangchinoline (FAN), and sinomenine (SIN) using berberine as internal standard. The TET, FAN, and SIN standard solutions were directly infused into IT‐MS for collecting MS1–3 spectra. The major fragment ions of analytes were confirmed and possible main cleavage pathways of fragment ions were studied. A bare fused‐silica capillary was used for separation of the analytes. A sheath liquid (50% aqueous methanol containing 0.2% acetic acid) to the capillary effluent with a nanoelectrospray ionization interface was added. Separation buffer comprised 80 mM solution of ammonium acetate, in a mixture of 70% methanol, 20% ACN, and 10% water, which also contained 1% acetic acid. The CE‐MS method was validated for linearity, sensitivity, accuracy, and precision, and then used to determine the content of the above components. The detection limits of TET, FAN, and SIN are 0.05, 0.08, and 0.15μg/mL, respectively. The precision was no more than 4.67% and the mean recovery of the analytes were 95.36–99.24%. This method was successfully applied to determine TET, FAN, and SIN in real samples radix Stephaniae tetrandrae and rhizomes of Menispermum dauricum.  相似文献   

4.
One of the challenging instrumental aspects in coupling an automated CE instrument with ESI mass spectrometry (CE‐MS) is finding the balance between the stability, reproducibility and sensitivity of the analysis and compatibility with the standard CE instrumentation. Here, we present a development of a new liquid junction based electrospray interface for automated CE‐MS, with a focus on the technical design followed by computer modeling of transport conditions as well as characterization of basic performance of the interface. This hybrid arrangement designed as a microfabricated unit attachable to the automated CE instrument allows using of a wide range of separation capillaries with respect to their diameter, length or internal coating (e.g., for suppressed electroosmotic flow). Different compositions of the ESI liquid and background electrolyte solutions can be used if needed. The microfabricated part, prepared by laser machining from polyimide, includes a self‐aligning liquid junction, a short transport channel, and a pointed sprayer for the electrospray ionization. This microfabricated part is positioned in a plastic connection block securing the separation capillary and flushing ports. Transport conditions were modelled using computer simulation and the real life performance of the interface was compared to that of a commercial sheath liquid interface. The basic performance of the interface was demonstrated by separations of peptides, proteins, and oligosaccharides.  相似文献   

5.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

6.
The present work illustrates potentialities of CE hyphenated with MS/MS for the simultaneous determination and identification of a mixture of simultaneously acting drugs in pharmaceutical and biological matrices. Here, the hyphenation was provided by ESI interface, while the MS/MS technique was based on the triple quadrupole configuration. Three drugs, namely pheniramine, phenylephrine, and paracetamol were determined and identified with high reliability due to their characterization in three different dimensions, i.e. electrophoresis and MS/MS, that prevented practically any interference. Appropriately selected transitions of the analytes (parent ion‐quantifier product ion‐qualifier product ion) provided their selective determination at maximum S/N. The proposed CE‐MS/MS method was validated (LOD/LOQ, linearity, precision, recovery, accuracy) and applied for (i) the multidrug composition pharmaceuticals, namely Theraflu®, and (ii) human urine taken after per‐oral administration of the same pharmaceutical preparation. The method was applied also for the investigation of potential weak associates of the drugs and monitoring of predicted (bio)degradation products of the drugs. Successful validation and application of the proposed method suggest its routine use in highly effective and reliable advanced drug control and biomedical research.  相似文献   

7.
Here, we present a miniaturized version of the flowing atmospheric-pressure afterglow (miniFAPA) ion source and use it for sheathless coupling of CE with MS. The simple design of the CE-miniFAPA-MS interface makes it easy to separate the electric potentials used for CE and for ionization. A pneumatically assisted nebulization of the CE effluent transfers the analytes from the liquid phase into the gas phase before they are ionized by interacting with reactive species produced by the FAPA. An important advantage of this interface is its high stability during operation: optimization of five different parameters indicated that the interface is not sensitive to minor deviations from the optimum values. Other advantages include ease of construction and maintenance, as well as relatively low cost. Samples with complex matrices, such as yeast extract, soil extract and urine, spiked with the test compounds, were successfully analyzed using the CE-miniFAPA-MS setup.  相似文献   

8.
Non‐aqueous capillary electrophoresis–mass spectrometry (NACE‐MS) was developed for trace analyses of β‐agonists (i.e. clenbuterol, salbutamol and terbutaline) in pork. The NACE was in 18 mM ammonium acetate in methanol–acetonitrile–glacial acetic acid (66 : 33 : 1, v/v/v) using a voltage of 28 kV. The hyphenation of CE with a time‐of‐flight MS was performed by electrospray ionization interface employing 5 mM ammonium acetate in methanol–water (80 : 20, v/v) as the sheath liquid at a flow rate of 2 μL/min. Method sensitivity was enhanced by a co‐injection technique (combination of hydrodynamic and electrokinetic injection) using a pressure of 50 mbar and a voltage of 10 kV for 12 s. The method was validated in comparison with HPLC–MS‐MS. The NACE‐MS procedure provided excellent detection limits of 0.3 ppb for all analytes. Method linearity was good (r2 > 0.999, in a range of 0.8–1000 ppb for all analytes). Precision showed %RSDs of <17.7%. Sample pre‐treatment was carried out by solid‐phase extraction using mixed mode reversed phase/cation exchange cartridges yielding recoveries between 69 and 80%. The NACE‐MS could be successfully used for the analysis of β‐agonists in pork samples and results showed no statistical differences from the values reported by the Ministry of Public Health, Thailand using HPLC‐MS‐MS method. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
毛细管电泳-电感耦合等离子质谱联用的接口设计   总被引:1,自引:0,他引:1  
描述了毛细管电泳电感耦合等离子体质谱(CE-ICP-MS)联用技术的单T型接口,自行设计了双T型接口,并对两接口的分析性能作了比较。解决了接口中的常见问题,使用节流阀减小自吸作用并降低了CE分离物的稀释倍数,排气阀使提升量保持稳定。经考察得知,采用自吸作用提升液流流量稳定,其重现性RSD小于5%;双T型接口较单T型接口对CE分离更有利。采用双T型接口联用时,CE分离La、Ce、Nd混合离子迁移时间RSD小于2%,MS信号RSD小于15%,且不同浓度样品经CE分离后其MS信号基本呈线性关系。  相似文献   

10.
Graphene has great potentials for the use in sample preparation due to its ultra high specific surface area, superior chemical stability, and excellent thermal stability. In our work, a novel graphene‐based SPE disk was developed for separation and preconcentration of trace polycyclic aromatic hydrocarbons from environmental water samples. Based on the strong π–π stacking interaction between the analytes and graphene, the analytes extracted by graphene were eluted by cyclohexane and then determined by GC‐MS. Under the optimized conditions, high flow rate (30 mL/min) and sensitivity (0.84–13 ng/L) were achieved. The proposed method was successfully applied to the analysis of real environmental water samples with recoveries ranging from 72.8 to 106.2%. Furthermore, the property of anticlogging and reusability was also improved. This work reveals great potentials of graphene‐based SPE disk in environmental analytical.  相似文献   

11.
mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product‐ and time‐consuming. CE‐MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off‐line CE‐UV/MALDI‐MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI‐MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI‐MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE‐UV/MALDI‐MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization.  相似文献   

12.
Capillary electrophoresis (CE) is a powerful separation method based on the migration of charged species under the influence of electric field. The main merits of CE are high separation efficiency, short analysis time and small consumption of solvents and samples. However, the main drawbacks of CE are generally lower sensitivity compared to classical column-chromatographic methods.Selectivity and/or sensitivity of CE separation can be improved by forming complexes between analytes and a complex-forming reagent present as an additive in the background electrolyte (BGE). We focus this review primarily on the application of inorganic complex-forming reagents added to the BGE to separate organic ligands. We briefly mention common CE separations of inorganic analytes (mainly metal ions) using BGEs with organic ligands (e.g., hydroxycarboxylic or aminopolycarboxylic acids) as selectors.The review involves brief theoretical consideration of the significance of the effect of complex formation on separation selectivity and/or sensitivity in CE, but the major topic is critical evaluation of different inorganic complex-forming reagents used recently in the CE analysis of organic compounds, including:
(i)
borate, tungstate and molybdate in separating organic compounds possessing vicinal -OH groups;
(ii)
ligand-exchange CE and capillary electrochromatography in chiral analysis; and,
(iii)
the role of metal ions as central ions employed for selectivity enhancement of CE separation of various classes of organic compounds, including biopolymers.
  相似文献   

13.
Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.  相似文献   

14.
A new approach to the selective comparative metabolite profiling of carboxylic acids in rat urine was established using CE‐MS and a method for positively pre‐charged and 2H‐coded derivatization. Novel derivatizing reagents, N‐alkyl‐4‐aminomethyl‐pyridinum iodide (alkyl=butyl, butyl‐d9 or hexyl), containing quaternary amine and stable‐isotope atoms (deuterium), were introduced for the derivatization of carboxylic acids. CE separation in positive polarity showed high reproducibility (0.99–1.32% RSD of migration time) and eliminated problems with capillary coating known in CE‐MS anion analyses. Essentially complete ionization and increased hydrophobicity after the derivatization also enhanced MS detection sensitivity (e.g. formic acid was detected at 0.5 pg). Simultaneous derivatization of one sample using two structurally similar reagents, N‐butyl‐4‐aminomethyl‐pyridinum iodide (BAMP) and N‐hexyl‐4‐aminomethyl‐pyridinum iodide, provided additional information for recognizing a carboxylic acid in an unknown sample. Moreover, characteristic fragmentation acquired by online CE‐MS/MS allowed for identification and categorization of carboxylic acids. Applying this method on rat urine, we found 59 ions matching the characteristic patterns of carboxylic acids. From these 59, 32 ions were positively identified and confirmed with standards. For comparative analysis, 24 standard carboxylic acids were derivatized by chemically identical but isotopically distinct BAMP and N‐butyl‐d9‐4‐aminomethyl‐pyridinium iodide, and their derivatization limits and linearity ranges were determined. Comparative analysis was also performed on two individual urine samples derivatized with BAMP and N‐butyl‐d9‐4‐aminomethyl‐pyridinium iodide. The metabolite profiling variation between these two samples was clearly visualized.  相似文献   

15.
In the present work, a new supported liquid membrane (SLM) has been developed for on‐chip electromembrane extraction of acidic drugs combined with HPLC or CE, providing significantly higher stability than those reported up to date. The target analytes are five widely used non‐steroidal anti‐inflammatory drugs (NSAIDs): ibuprofen (IBU), diclofenac (DIC), naproxen (NAX), ketoprofen (KTP) and salicylic acid (SAL). Two different microchip devices were used, both consisted basically of two poly(methyl methacrylate) (PMMA) plates with individual channels for acceptor and sample solutions, respectively, and a 25 µm thick porous polypropylene membrane impregnated with the organic solvent in between. The SLM consisting of a mixture of 1‐undecanol and 2‐nitrophenyl octyl ether (NPOE) in a ratio 1:3 was found to be the most suitable liquid membrane for the extraction of these acidic drugs under dynamic conditions. It showed a long‐term stability of at least 8 hours, a low system current around 20 µA, and recoveries over 94% for the target analytes. NPOE was included in the SLM to significantly decrease the extraction current compared to pure 1‐undecanol, while the extraction properties was almost unaffected. Moreover, it has been successfully applied to the determination of the target analytes in human urine samples, providing high extraction efficiency.  相似文献   

16.
This study was focused on examining the influence of gas flow parameters on capillary electrophoresis/mass spectrometry (CE /MS) performance using sheath-liquid CE /MS interfaces. The effects of nebulizing and drying gas velocity and drying gas temperature on CE separation and MS detection sensitivity were systematically determined. Nebulizing gas velocity was observed to be a critical parameter in the optimization of CE /MS method, since it affected both MS detection sensitivity, and also CE separation efficiency for one interface design tested. Better detection sensitivity was obtained when the nebulizing gas velocity was increased. However, high velocity of the nebulizing gas flow can cause a hydrodynamic bulk flow inside the CE capillary, thus clearly increasing the apparent mobility and decreasing the resolution obtained for the compounds studied. Increasing the drying gas velocity or temperature did not affect the apparent mobility or the separation efficiency and the temperature could be increased to achieve the optimal detection sensitivity in the CE /MS analysis. For comparison, the effects of nebulizing gas flow were studied using a different design of the coaxial sheath-liquid CE /MS interface, and in this case better detection sensitivity but no effect on CE separation efficiency was observed with increased nebulizing gas velocity. These different effects of nebulizing gas flow on the CE bulk flow were concluded to result from pressure differences at the tip of the CE capillaries for the different CE /MS interface arrangements. It is therefore recommended that the cross-sectional dimensions of the fused-silica and steel capillaries, and the gas streamlines, should be optimized when CE /MS interfaces are built. Moreover, the effect of gas flow on CE separation should be studied when optimizing the CE /MS operation parameters.  相似文献   

17.
Guo L  Qiu B  Jiang Y  You Z  Lin JM  Chen G 《Electrophoresis》2008,29(11):2348-2355
Despite its low equipment cost and simple design, as one of the sensitive detectors for CE, the chemiluminescence (CL) detector was less developed compared to the detectors of MS and LIF. The main reasons were the limitation of CL reagents, the repeatability problems and the relatively low sensitivity compared to LIF. In this paper, a highly sensitive CE-CL detection system was developed for detection of some enkephalin-related peptides labeled with acridinium ester. A new detection interface was designed for CE with CL detection of acridinium ester and its labeled analytes. The interface included two sections: one was used to acidify the capillary outflow so that the corresponding acridinium pseudo-base form can be changed into acridinium ester form by adding excess acid to the system; the other was designed to provide a suitable solution to produce the CL from acridinium ester. The effect factors, such as pH, the concentration of reaction reagents and the flow rates of the reagents, were investigated. The results showed that acridinium ester had similar CL properties in this interface when pH values of CE BGE were changed from 2.0 to 10.8. The interface was used to detect acridinium ester and three acridinium ester-labeled enkephalin-related peptides, the corresponding LODs were found to be in the attomole range. This CL detection system proved to be of high sensitivity, good repeatability, and relatively low cost.  相似文献   

18.
This paper describes the development and design of a new, efficient, simple and robust interface for coupling capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry. The interface is based on a modified microconcentric nebulizer which permits a low flow rate of about 6 μL/min in the free aspiration mode. This interface construction provides an electrical connection for stable electrophoretic separations and adapts the flow rate of the electro-osmotic flow inside the CE capillary to the flow rate of the nebulizer for efficient transport of the analytes into the plasma. By optimization of the fluid mechanical properties the interface prevents the nebulizer from causing any laminar flow in the CE capillary and thus the high resolution power of CE can be preserved. Furthermore, this new device permits independent optimization of the nebulization from the CE whereby exact positioning of the CE capillary is not necessary, thus enabling fast exchange. A low dead volume spraychamber has been constructed which circumvents any band broadening of the sharp CE signals. Peak widths down to 3.5 s comparable to CE with UV detection are possible. Received: 5 February 1999 / Revised: 21 April 1999 / Accepted: 23 April 1999  相似文献   

19.
This paper describes the development and design of a new, efficient, simple and robust interface for coupling capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry. The interface is based on a modified microconcentric nebulizer which permits a low flow rate of about 6 μL/min in the free aspiration mode. This interface construction provides an electrical connection for stable electrophoretic separations and adapts the flow rate of the electro-osmotic flow inside the CE capillary to the flow rate of the nebulizer for efficient transport of the analytes into the plasma. By optimization of the fluid mechanical properties the interface prevents the nebulizer from causing any laminar flow in the CE capillary and thus the high resolution power of CE can be preserved. Furthermore, this new device permits independent optimization of the nebulization from the CE whereby exact positioning of the CE capillary is not necessary, thus enabling fast exchange. A low dead volume spraychamber has been constructed which circumvents any band broadening of the sharp CE signals. Peak widths down to 3.5 s comparable to CE with UV detection are possible. Received: 5 February 1999 / Revised: 21 April 1999 / Accepted: 23 April 1999  相似文献   

20.
The applicability of capillary electrophoresis (CE) in combination with atmospheric pressure ionization mass spectrometry (API-MS) is demonstrated for the determination of organic acids and in particular for haloacetic acids. CE-conditions, sheath flow and MS-parameters were optimized with respect to the separation of the analytes and mass spectrometric sensitivity. CE/MS turned out to be an attractive alternative for the determination of haloacetic acids to existing methods based on GC-ECD. Employing CE/MS derivatization is not necessary which saves time and avoids possible sources of errors. In the present work the sample pre-treatment is performed by liquid-liquid extraction using methyl tert.-butyl ether as the extraction solvent. The organic phase is brought to dryness in a stream of nitrogen gas and the residue is dissolved in methanol and analyzed by CE/MS using a mixture of 2-propanol/water 80?:?20 containing triethylamine as the sheath liquid in the interface. Best results for the separation of all nine possible bromo- and chloroacetic acids together with two internal standards are obtained with a carrier electrolyte consisting of ammonium acetate/acetic acid in methanol; to resolve the strongly acidic trihaloacetic acids as well as the less acidic monohaloacetic acids, a careful optimization of the acetic acid content is necessary. The method was applied to the determination of haloacetic acids in real water samples. With optimized CE and MS conditions detection limits between 0.3 and 7.6 μg/L in the original water samples were achieved, employing a sample volume of 30 mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号