首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two patterns of signal amplification lateral flow immunoassay (LFIA), which used anti-mouse secondary antibody-linked gold nanoparticle (AuNP) for dual AuNP-LFIA were developed. Escherichia coli O157:H7 was selected as the model analyte. In the signal amplification direct LFIA method, anti-mouse secondary antibody-linked AuNP (anti-mouse-Ab-AuNP) was mixed with sample solution in an ELISA well, after which it was added to LFIA, which already contained anti-E. coli O157:H7 monoclonal antibody-AuNP (anti-E. coli O157:H7-mAb-AuNP) dispersed in the conjugate pad. Polyclonal antibody was the test line, and anti-mouse secondary antibody was the control line in nitrocellulose (NC) membrane. In the signal amplification indirect LFIA method, anti-mouse-Ab-AuNP was mixed with sample solution and anti-E. coli O157:H7-mAb-AuNP complex in ELISA well, creating a dual AuNP complex. This complex was added to LFIA, which had a polyclonal antibody as the test line and secondary antibody as the control line in NC membrane. The detection sensitivity of both LFIAs improved 100-fold and reached 1.14 × 103 CFU mL−1. The 28 nm and 45 nm AuNPs were demonstrated to be the optimal dual AuNP pairs. Signal amplification LFIA was perfectly applied to the detection of milk samples with E. coli O157:H7 via naked eye observation.  相似文献   

2.
3.
Food poisoning causes untold discomfort to many people each year. One of the primary culprits in food poisoning is Escherichia coli O157:H7. While most cases cause intestinal discomfort, up to 7% of the incidences lead to a severe complication called hemolytic uremic syndrome which may be fatal. The traditional method for detection of E. coli O157:H7 in cases of food poisoning is to culture the food matrices and/or human stool. Additional performance-based antibody methods are also being used. The NRL array biosensor was developed to detect multiple antigens in multiple samples with little sample pretreatment in under 30 min. An assay for the specific detection of E. coli O157:H7 was developed, optimized and tested with a variety of spiked food matrices in this study. With no sample pre-enrichment, 5 × 103 cells mL−1 were detected in buffer in less than 30 min. Slight losses of sensitivity (1-5 × 10−4 cell mL−1) but not specificity occur in the presence of high levels of extraneous bacteria and in various food matrices (ground beef, turkey sausage, carcass wash, and apple juice). No significant difference was observed in the detection of E. coli O157:H7 in typical culture media (Luria Broth and Tryptic Soy Broth).  相似文献   

4.
A fluorescent quantum dot-based antibody array, used in sandwich format, has been developed to detect Escherichia coli O157:H7. Numerous parameters such as solid support, optimal concentration of immunoreagents, blocking reagents, and assay time were optimized for array construction. Quantum dot-conjugated anti-IgG was used as the detecting system. The array allows the detection of E. coli O157:H7 at concentrations below 10 CFU mL−1 without sample enrichment, exhibiting an increase of three orders of magnitude in the limit of detection compared to ELISA. The interference caused by Gram (+) and Gram (−) bacteria was negligible at low concentrations of bacteria.  相似文献   

5.
Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H2O2) and H2O2-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H2O2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H2O2, as well as the incubation time between H2O2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 102 CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 103 CFU/mL to 1.18 × 106 CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control.  相似文献   

6.
Foodborne diseases caused by pathogens are one of the major problems in food safety. Convenient and sensitive point-of-care rapid diagnostic tests for food-borne pathogens have been a long-felt need of clinicians. Commonly used methods for pathogen detection rely on conventional culture-based tests, antibody-based assays and polymerase chain reaction (PCR)-based techniques. These methods are costly, laborious and time-consuming. Herein, we present a simple and sensitive aptamer based biosensor for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7). In this assay, two different aptamers specific for the outmembrane of E. coli O157:H7 were used. One of the aptamers was used for magnetic bead enrichment, and the other was used as a signal reporter for this pathogen, which was amplified by isothermal strand displacement amplification (SDA) and further detected by a lateral flow biosensor. Only the captured aptamers on cell membrane were amplified, limitations of conventional DNA amplification based method such as false-positive can be largely reduced. The generated signals (red bands on the test zone of a lateral flow strip) can be unambiguously read out by the naked eye. As low as 10 colony forming units (CFU) of E. coli O157:H7 were detected in this study. Without DNA extraction, the reduced handling and simpler equipment requirement render this assay a simple and rapid alternative to conventional methods.  相似文献   

7.
E. coli O157:H7 is a pathogenic bacterium producing verotoxins that could lead to serious complications such as hemolytic uremia syndrome. Fast detection of such pathogens is important. For rapid detection, aptamers are quickly gaining traction as alternative biorecognition molecules besides conventional antibodies. Several DNA aptamers have been selected for E. coli O157:H7. Nonetheless, there has not been a comparative study of the binding characteristics of these aptamers. In this work, we present a comprehensive analysis of binding characteristics including binding affinity (Kd) and binding capacity (Bmax) of DNA-based aptamers for E. coli O157:H7 using qPCR. Our results show that aptamer E18R has the highest binding capacity to E. coli 157:H7 and the highest specificity over non-pathogenic E. coli strains K12 and DH5α. Our study also finds that the common biotin-tag modification at 5′ end typically changes the binding capacity significantly. For most of the selected aptamers, the binding capacity after a biotin-tag modification decreases. There exists a discrepancy in the binding capability between the selected aptamer and the aptamer used for detection. Our study also shows that a lower concentration of Mg2+ ions in the binding buffer leads to a decrease in the binding capacity of E17F and E18R, while it does not affect the binding capacity of S1 and EcoR1.  相似文献   

8.
Chemiluminescence multichannel immunosensor for biodetection   总被引:1,自引:0,他引:1  
An improved portable detector for biological compounds, the chemiluminescence multichannel immunosensor (CL-MADAG), has been developed and characterised. The device is based on a capillary ELISA technique in combination with a miniaturised fluidics system and uses chemiluminescence as the detection principle. The fluidics system construction allows three chemiluminescence immunoassays to be performed simultaneously within three fused silica capillaries (FSC). The CL-MADAG was characterised in a series of experiments with staphylococcal enterotoxin B (SEB) as a model toxin, the bacterial phage virus M13 as a virus simulant, and a pathogenic strain of Escherichia coli as simulant for bacteria. It was shown that the CL-MADAG can assay liquid samples for these substances within 24 min. The detection limits were 5 ng/ml for SEB, 105 cfu/ml for E. coli O157:H7 and 107 pfu/ml for M13.  相似文献   

9.
The development and characterization of a magnetic bead (MB)-quantum dot (QD) nanoparticles based assay capable of quantifying pathogenic bacteria is presented here. The MB-QD assay operates by having a capturing probe DNA selectively linked to the signaling probe DNA via the target genomic DNA (gDNA) during DNA hybridization. The signaling probe DNA is labeled with fluorescent QD565 which serves as a reporter. The capturing probe DNA is conjugated simultaneously to a MB and another QD655, which serve as a carrier and an internal standard, respectively. Successfully captured target gDNA is separated using a magnetic field and is quantified via a spectrofluorometer. The use of QDs (i.e., QD565/QD655) as both a fluorescence label and an internal standard increased the sensitivity of the assay. The passivation effect and the molar ratio between QD and DNA were optimized. The MB-QD assay demonstrated a detection limit of 890 zeptomolar (i.e., 10−21 mol L−1) concentration for the linear single stranded DNA (ssDNA). It also demonstrated a detection limit of 87 gene copies for double stranded DNA (dsDNA) eaeA gene extracted from pure Escherichia coli (E. coli) O157:H7 culture. Its corresponding dynamic range, sensitivity, and selectivity were also presented. Finally, the bacterial gDNA of E. coli O157:H7 was used to highlight the MB-QD assay's ability to detect below the minimum infective dose (i.e., 100 organisms) of E. coli O157:H7 in water environment.  相似文献   

10.
《Analytical letters》2012,45(17):2690-2704
A disposable immunosensor for the detection of Escherichia coli O157:H7 based on a multiwalled carbon nanotube–sodium alginate nanocomposite film was constructed. The nanocomposite was placed on a screen-printed carbon electrode, and horseradish peroxidase-labeled antibodies were immobilized to E. coli O157:H7 on the modified electrode to construct the immunosensor. The modification procedure was characterized by atomic force microscopy and cyclic voltammetry. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to E. coli O157:H7 in a concentration range of 103–1010 cfu/mL, with a relatively low detection limit of 2.94 × 102 cfu/mL (S/N = 3). This immunosensor exhibited satisfactory specificity, reproducibility, stability, and accuracy, making it a potential alternative tool for early assessment of E. coli O157:H7.  相似文献   

11.
A label-free capacitive immunosensor based on quartz crystal Au electrode was developed for rapid and sensitive detection of Escherichia coli O157:H7. The immunosensor was fabricated by immobilizing affinity-purified anti-E. coli O157:H7 antibodies onto self-assembled monolayers (SAMs) of 3-mercaptopropionic acid (MPA) on the surface of a quartz crystal Au electrode. Bacteria suspended in solution became attached to the immobilized antibodies when the immunosensor was tested in liquid samples. The change in capacitance caused by the bacteria was directly measured by an electrochemical detector. An equivalent circuit was introduced to simulate the capacitive immunosensor. The immunosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The experimental results indicated that the capacitance change was linearly correlated with the cell concentration of E. coli O157:H7. The immunosensor was able to discriminate between cellular concentrations of 102–105 cfu mL−1 and has applications in detecting pathogens in food samples. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were also employed to characterize the stepwise assembly of the immunosensor.  相似文献   

12.
A novel biosensor based on single-stranded DNA (ssDNA) probe functionalized aluminum anodized oxide (AAO) nanopore membranes was demonstrated for Escherichia coli O157:H7 DNA detection. An original and dynamic polymerase-extending (PE) DNA hybridization procedure is proposed, where hybridization happens in the existence of Taq DNA polymerase and dNTPs under controlled reaction temperature. The probe strand would be extended as long as the target DNA strand, then the capability to block the ionic flow in the pores has been prominently enhanced by the double strand complex. We have investigated the variation of ionic conductivity during the fabrication of the film and the hybridization using cyclic voltammetry and impedance spectroscopy. The present approach provides low detection limit for DNA (a few hundreds of pmol), rapid label-free and easy-to-use bacteria detection, which holds the potential for future use in various ss-DNA analyses by integrated into a self-contained biochip.  相似文献   

13.
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 × 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays. Received: 13 October 2000 / Revised: 13 November 2000 / Accepted: 13 November 2000  相似文献   

14.
Escherichia coli O157:H7 remains a continuous public health threat, appearing in meats, water, fruit juices, milk, cheese, and vegetables, where its ingestion at concentrations of perhaps as low as 10 to 100 organisms can result in potent toxin exposure and severe damage to the lining of the intestine. Abdominal pain and diarrhea develop, which in the very young or elderly can progress towards hemolytic uremic syndrome and kidney failure. To assist in the detection of E. coli O157:H7, a recombinant bacteriophage reporter was developed that uses quorum sensing (luxI/luxR) signaling and luxCDABE-based bioluminescent bioreporter sensing to specifically and autonomously respond to O157:H7 serotype E. coli. The bacteriophage reporter, derived from phage PP01, was tested in artificially contaminated foodstuffs including apple juice, tap water, ground beef, and spinach leaf rinsates. In apple juice, detection of E. coli O157:H7 at original inoculums of 1 CFU mL−1 occurred within approximately 16 h after a 6-h pre-incubation, detection of 1 CFU mL−1 in tap water occurred within approximately 6.5 h after a 6-h pre-incubation, and detection in spinach leaf rinsates using a real-time Xenogen IVIS imaging system resulted in detection of 1 CFU mL−1 within approximately 4 h after a 2-h pre-incubation. Detection in ground beef was not successful, however, presumably due to the natural occurrence of quorum sensing autoinducer (N-3-(oxohexanoyl)-l-homoserine lactone; OHHL), which generated false-positive bioreporter signals in the ground beef samples.  相似文献   

15.
Chen CS  Durst RA 《Talanta》2006,69(1):232-238
A novel universal reagent for immunoassays, protein G-liposomal nanovesicles has been developed and successfully used in an immunomagnetic bead sandwich assay for the detection of Escherichia coli O157:H7 [C.-S. Chen, A.J. Baeumner, R.A. Durst, Talanta 67 (2005) 205]. To demonstrate the universal capability of protein G-liposomal nanovesicles, this reagent was used to develop an array-based immunosorbent assay for the simultaneous detection of E. coli O157:H7, Salmonella, and Listeria monocytogenes. Both direct and competitive immunoassay formats were used to demonstrate the feasibility of detecting multiple analytes in a single test by using universal protein G-liposomal nanovesicles. Both pure and mixed cultures were examined in the direct immunoassay format. Results indicate that the limits of detection (LODs) of the direct assay for E. coli O157:H7, Salmonella enterica serovar Typhimurium and L. monocytogenes in pure cultures were approximately 100, 500 and 1.5 × 104 CFU/ml, respectively. In mixed cultures, the LODs were approximately 3.1 × 103, 7.8 × 104, and 7.9 × 105 CFU/ml. In the competitive assay format, the LODs for E. coli O157:H7, S. enterica serovar Typhimurium, and L. monocytogenes were approximately 1.5 × 104, 5 × 104, and 1.2 × 105 CFU/ml for the pure cultures. These results showed that protein G-liposomal nanovesicles can be successfully used in a simultaneous immunoassay for several food-borne pathogens, thereby demonstrating that they are effective universal reagents for use in immunoassays.  相似文献   

16.
Shiga toxin Escherichia coli (STEC), also called verotoxin-producing E. coli, is a major cause of food-borne illness, capable of causing hemorrhagic colitis and hemolytic–uremic syndrome (HUS). This study was carried out to evaluate the presence of (STEC) and E. coli O157:H7 in shellfish and Mediterranean coastal environments of Morocco. The contamination of shellfish and marine environment with Shiga toxin-producing E. coli (STEC) and E. coli O157:H7, was investigated during 2007 and 2008. A total of 619 samples were analyzed and 151 strains of E. coli were isolated. The presence of the stx1, stx2, and eae genes was tested in E. coli isolates strains using a triplex polymerase chain reaction. STEC was detected in three positives samples (1.9%), corresponding to the serotype O157:H7, the others Shiga toxin-producing E. coli non-O157 were also detected.  相似文献   

17.
In previous studies we have developed a simple electrokinetically-controlled lab-on-a-chip for heterogeneous immunoassay. In that method, all the sequential operations in an immunoassay, such as reagent loading and washing, were performed automatically by electrokinetically controlling the flow in an H-shaped microchannel. Here, we demonstrated further development of a high-throughput immunoassay microfluidic chip, and the application of the new immunoassay microfluidic chip in assaying human serum. The microfluidic immunoassay analyzed ten samples in parallel in 22 min. Bacterial antibodies in samples were captured by antigens pre-patterned on the bottom wall of a microchannel and then bound with TRITC-labeled detection antibodies to generate fluorescent signals. With optimized surface concentration of antigen, the assay detected Escherichia coli O157:H7 antibody and Helicobacter pylori antibody from buffer solutions in concentration ranges of 0.02-10 μg mL−1 and 0.1-50 μg mL−1, respectively. Human sera that were E. coli-positive or H. pylori-positive were accurately distinguished from respective negative controls. Moreover, the two antibodies, anti-E. coli and anti- H. pylori antibodies, could be simultaneously detected from human serum. This electrokinetically-controlled immunoassay shows an excellent potential for efficiently detecting multiple pathogenic infections in clinical environments.  相似文献   

18.
An oscillatory-flow multiplex PCR method in a capillary microfluidic channel has been developed for the simultaneous determination of pre-purified DNA of multiple foodborne bacterial pathogens. The PCR solution passes three temperature zones in an oscillatory manner. The thermal stability and sample evaporation of the microfluidic device were investigated. Under controlled conditions, a highly efficient multiplex PCR was accomplished as demonstrated for the simultaneous amplifications of 278 bp, 168 bp, and 106 bp DNA fragments within 35 min after 35 cycles for simultaneous detection of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes. This is much shorter than that of a conventional PCR machine. The detection limits of bacterial genome DNA for the three species are about 399, 314, and 626 copies per μL, respectively. This is comparable to those obtained with the conventional multiplex PCR. Consequently, the oscillatory-flow multiplex PCR technology holds good potential for rapid amplification and detection of nucleic acids of microbial foodborne pathogens.
Figure
By using an oscillatory-flow multiplex PCR technology, the simultaneous amplifications of 278 bp, 168 bp, and 106 bp DNA fragments can be achieved in 35 min for detection of S. enterica, E. coli O157:H7, and L. monocytogenes. This is much shorter than that of a conventional multiplex PCR.  相似文献   

19.
Abuknesha RA  Darwish F 《Talanta》2005,65(2):343-348
A tandem technique for the detection of very low levels E. coli within about 2 h is demonstrated. The technique couples the widely employed microbial enzymatic detection methods with an immunoassay step. The bacterial marker enzyme, E. coli β-D-galactosidase, was used in conjunction with synthetic enzyme substrates to produce products that could be measured with a highly sensitive enzyme-labelled immunosorbent assay (ELISA). The commercially available 4-methylumbelliferyl-β-D-galactoside and a newly prepared substrate, 4-methylcoumarin-3-propionate-7-O-β-D-galactoside, were used with an ELISA for 7-hydroxy-4-methylcoumarin to demonstrate the detection of low levels of E. coli. The 2 h test indicates that a few viable bacteria cells could be detected by the tandem procedure. The end point of the test is an ELISA with colorimetric measurement step. The novel approach retains the essential features of the microbial enzymatic detection procedures and provides a highly sensitive detection system that can be used for rapid screening or quantification of viable microbial cells in water samples. The tandem test is generic for commonly employed glycosidases and other marker enzymes for which 4-methylumbillerone substrates are available.  相似文献   

20.
The authors report on a rapid voltammetric method for simultaneous determination of the pathogens E. coli and Salmonella typhimurium (S. typh.) by detecting the rfbE gene of E. coli O157:H7 and gyrB gene of S. typh., respectively, and by using polymerase-assisted target recycling amplification. The assay was constructed by self-assembly of the respective hairpin probes (labeled with the electrochemical probes Methylene Blue and ferrocene) on the surface of a gold electrode. After hybridization between target DNA and hairpin probes (HPs) has occurred, the primers hybridize with the open-chain HPs and initiate extension reactions in the presence of polymerase and deoxyribonucleoside triphosphates. This results in the release of the redox labels from the electrode surface and the target dissociating from the HPs. The released target will bind to other HPs to activate new cycles, which results in enhanced suppression of current, measured best at ?0.27 V and +0.36 V (vs. Ag/AgCl) for parallel detection of E. coli DNA and S. typh. DNA, respectively. The method presented here based on target recycling amplification and its integration into multiplexed electrochemical detection of pathogens was successfully applied to quantitative determination of E. coli O157:H7 and S. typh. in synthetic samples. In our perception, the strategy presented here represents a rapid and universal platform for sensitive and multiplexed quantitation of pathogens and related molecular diagnostic targets of relevance in food safety control.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号