首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A simpler UV-vis spectrophotometric method was investigated for hydroquinone (HQ) determination using KMnO4 as oxidizing agent for conversion of HQ to p-benzoquinone (BQ) as well as signal enhancer. Various parameters such as analytical wavelength, stability time, temperature, pH, solvent effect and interference of chemicals were checked and parameters optimized by using 1 μg ml−1 standard solution of HQ. Beer's Law was applicable in the range of 0.07-2 μg ml−1 and 0.005-0.05 μg ml−1 at 245.5 nm and at 262 nm for aqueous standard solutions of HQ with linear regression coefficient value of 0.9978 and 0.9843 and detection limit of 0.021 μg ml−1 and 0.0016 μg ml−1 HQ, respectively. Standard deviation of 1.7% and 2.4% was true for 1 μg ml−1 and 0.03 μg ml−1 HQ solution (n = 11) run at respective wavelengths. The method was successfully applied to dilute waste photographic developer samples for free HQ determination.  相似文献   

2.
Nanometer-sized fluorescent particles have been successfully synthesized. A synchronous fluorescence method, with high sensitivity and selectivity, has been developed for rapid determination of protein with functionalized CdS as a fluorescence probe. When Δλ=260 nm, maximum synchronous fluorescence is produced at 274 nm at pH 7.0. Under optimal conditions, the calibration graphs are linear over the range 0.1-3.0 μg ml−1 for bovine serum albumin (BSA), 0.1-11.0 μg ml−1 for γ-globulin (γ-G) and 0.1-1.4 μg ml−1 for human serum albumin (HSA), respectively. Limits of determination were 0.01 μg ml−1 for BSA, 0.019 μg ml−1 for γ-G and 0.021 μg ml−1 for HSA, respectively. The relative standard deviations of seven replicate measurements were 1.8% for 1.0 μg ml−1 BSA, 2.2% for 1.0 μg ml−1 γ-G and 2.3% for 1.0 μg ml−1 HSA.  相似文献   

3.
A novel flow-injection chemiluminescence method for the determination of DNA at ultra-trace level has been established. In 0.8 M sulfuric acid media, the chemiluminescence of the rhodamine B-cerium (IV) or Ce(IV) system is enhanced by DNA, activated previously by imidazole-HCl buffer solution (pH 7.0). The enhanced intensity of chemiluminescence is in proportion to log DNA concentration 1.0×10−8 to 0.1 μg ml−1 for herring sperm DNA and 2.0×10−6 to 0.2 μg ml−1 for calf thymus DNA with 3σ detection limits of 8.3×10−9 μg ml−1 for herring sperm DNA and 3.5×10−7 μg ml−1 for calf thymus DNA, respectively. The relative standard deviation for 1.0×10−4 μg ml−1 herring sperm DNA was 0.99% and 2.0×10−3 μg ml−1 for calf thymus DNA was 1.1% (n=11). Using the optimized system, DNA contents in six synthetic samples has been determined with recoveries of 99.5-109.0%. The possible mechanism has also been studied in this paper.  相似文献   

4.
A new capillary electrophoresis (CE) method for the determination of quinolizidine alkaloids in Sophora medicinal plants was developed. A total of seven alkaloid components (cytisine, sophocarpine, matrine, lehmannine, sophoranol, oxymatrine and oxysophocarpine) were separated within 15 min. The running buffer was a 50 mM phosphate buffer containing 1%HP-β-CD and 3.3% isopropanol. The linear calibration ranges were 5.50-88.0 μg ml−1 for cytisine and lehmannine, 5.00-88.0 μg ml−1 for sophocarpine and sophoranol, 5.60-89.6 μg ml−1 for matrine and oxysophocarpine, and 24.0-384 μg ml−1 for oxymatrine. The recoveries of the seven alkaloids were 96.0-102.9% with relative standard deviations from 1.50 to 3.00% (n = 5). The method was successfully applied to different Sophora medicinal plants including Sophora flavescens, Sophora tonkinensis and Sophora alopecuroides.  相似文献   

5.
A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6×10−5 to 0.26 μg ml−1 for calf thymus DNA and 5.0×10−8 to 5.0×10−5 μg ml−1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5×10−6 μg ml−1 for calf thymus DNA and 4.3×10−8 μg ml−1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.  相似文献   

6.
A new, accurate, sensitive and fast reversed-phase high-performance liquid chromatography (RP-HPLC) as an analytical method for the quantitative determination of 11 drugs in human urine was worked out, optimized and validated. The objects of analysis were imipenem (IMP), paracetamol (PAR), dipyrone (DPR), vancomycin (VCM), amikacin (AMK), fluconazole (FZ), cefazolin (CFZ), prednisolone (PRE), dexamethasone (DEX), furosemide (FUR) and ketoprofen (KET) belonging to four different groups (antibiotics, analgesic, demulcent and diuretic). For HPLC analysis, diode array (DAD) and fluorescence (FL) detectors were used. The separation of analyzed compounds was conducted by means of a LiChroCART® Purospher® C18e (125 mm × 3 mm, particle size 5 μm) analytical column with LiChroCART® LiChrospher® C18 (4 mm × 4 mm, particle size 5 μm) pre-column with gradient elution. Analyzed drugs were determined within 20 min. The mobile phase was comprised of various proportions of methanol, acetonitrile and 0.05% trifluoroacetic acid in water. AMK was separated and determined from human urine using ortho-phthaldialdehyde-3-mercaptopropionic acid (OPA-3-MPA) as a fluorescent reagent by RP-HPLC-FL. The following retention times for drugs IMP, PAR, DPR, VCM, AMK, FZ, CFZ, PRE, DEX, FUR and KET in human urine were found: 4.01 min, 4.86 min, 6.71 min, 8.14 min, 9.46 min, 10.01 min, 10.90 min, 13.34 min, 14.06 min, 16.03 min and 18.98 min, respectively. Excellent linearity was obtained for compounds in the range of concentration: 0.35-42 μg ml−1, 0.5-45 μg ml−1, 4.5-38 μg ml−1, 0.25-25 μg ml−1, 0.5-35 μg ml−1, 0.25-22 μg ml−1, 0.03-52 μg ml−1, 0.15-25 μg ml−1, 0.25-28 μg ml−1, 0.05-18 μg ml−1 and 0.15-35 μg ml−1 for IMP, PAR, DPR, VCM, AMK, FZ, CFZ, PRE, DEX, FUR and KET, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for analyzed drugs were calculated in all cases and recovery studies were also performed. Ten human urine samples obtained from patients treated in hospital have been tested. In analyzed samples, one or more drugs from the 11 examined drugs were detected. The concentrations of examined drugs in urine samples ranged between: 1.5-12 μg ml−1 of PAR, 5.2-11.5 μg ml−1 of DPR, 0.13-9.5 μg ml−1 of CFZ and 0.1-8 μg ml−1 of FUR. This method can be successfully applied to routine determination of all these drugs in human urine samples.  相似文献   

7.
Al-Arfaj NA 《Talanta》2004,62(2):255-263
A flow-injection (FI) methodology using (2,2′-dipyridyl) ruthenium(II) [Ru(dipy)32+] chemiluminescence (CL) was developed for the rapid and sensitive determination of metoclopramide hydrochloride. The method is based on the CL reaction of metoclopramide with Ru(dipy)32+ and KMnO4 in a sulfuric acid medium. Under the optimum conditions, a calibration graph was obtained over the concentration range 0.005-3.5 μg ml−1 with a limit of detection (S/N=2) of 1 ng ml−1. The correlation coefficient was 0.99993 (n=8) with a relative standard deviation of 0.48% for 10 determinations of 1 μg ml−1 of drug. The method was successfully applied to the determination of metoclopramide in pharmaceutical preparations and biological fluids after IP administration of 25 mg kg−1 dose to rats. The elimination half-life was 2.5±0.4 h.  相似文献   

8.
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil™ TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l−1 hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l−1 in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l−1 thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019 ± 0.001 μg g−1 (n = 3); provisional value: 0.0212 μg g−1] and SRM 2556 used auto catalyst certified reference material [315 ± 4 μg g−1 (n = 4); certified value: 326 μg g−1]. The detection limit (3σ) of 0.28 ng ml−1 was obtained for 5 ml of sample solution. The sample throughputs for 5 ml and 100 μl of the sample solutions were 10 and 15 h−1, respectively.  相似文献   

9.
A chemiluminescence (CL) flow system for determination of thyroxine (Thy) is presented. It is based on the catalytic effect of cobalt(II) on the CL reaction between luminol and hydrogen peroxide. The iodinated chemical structure of Thy causes a heavy atom effect. The luminol CL signals show significant quenching by Thy. The calibration graph for Thy is linear for 15-70 μg ml−1 and the 3σ detection limits are 27 μg ml−1 for d-Thy and 23 μg ml−1 for l-Thy.  相似文献   

10.
The inhibitory effects of five hydroxyanthraquinones (HAQs) from root and rhizoma of Rheum officinale Baill, a traditional Chinese medicinal (TCM) herb, on Staphylococcus aureus growth were investigated by calorimetry. The power-time curves of S.aureus with and without HAQ were acquired and the extent and duration of inhibitory effects on the metabolism evaluated by growth rate constants (k1, k2), half inhibitory ratio (IC50), maximum heat output (Pmax) and peak time (tp). The value of k1 and k2 of S. aureus in the presence of the five HAQs decreased with the increasing concentrations of HAQs. Moreover, Pmax was reduced and the value of tp increased with increasing concentrations of the five drugs. The inhibitory activity varied for different drugs. IC50 of the five HAQs was 4 μg ml−1 for emodin, 3.5 μg ml−1 for rhein, 10 μg ml−1 for aloe-emodin, 1000 μg ml−1 for chrysophanol, 1600 μg ml−1 for physcion. The sequence of antimicrobial activity of the five HAQs: rhein > emodin > aloe-emodin > chrysophanol > physicion.  相似文献   

11.
《Analytica chimica acta》2003,476(1):141-148
A flow injection (FI) system combined with two photochemical processes is developed for the sensitive and rapid determination of carbaryl. It is based on the on-line photo-conversion of carbaryl into methylamine which subsequently reacts with Ru(bpy)33+ generated through the on-line photo-oxidation of Ru(bpy)32+ with peroxydisulphate. The linear concentration range of application was 0.04-4.0 μg ml−1 of carbaryl, with an R.S.D. of 1.2% (for a level of 0.50 μg ml−1) and a detection limit of 0.012 μg ml−1. The sample throughput was 200 injections per hour. The applicability of the method was demonstrated by determining carbaryl in commercial formulations, water, soil, grain and blood serum.  相似文献   

12.
Fan J  Wang A  Feng S  Wang J 《Talanta》2005,66(1):236-243
A new sequential injection spectrophotometric method was proposed for the determination of metoclopramide and tetracaine hydrochloride. The method was based on the detection of an unstable red intermediate compound resulting from the reaction of metoclopramide or tetracaine hydrochloride with potassium dichromate, in the presence of sodium oxalate, in sulfuric acid solution. The related reaction mechanisms of this new method have been studied. The experimental conditions were optimized for the stopped-flow and continuous-flow sequential injection models. For continuous flow, the linear range for determination of metoclopramide, the detection limit and the sampling frequency were 13-130 μg ml−1, 9.4 μg ml−1 and 40 samples per hour, respectively. For stopped flow, they were 3-42 μg ml−1, 1.0 μg ml−1 and 18 h−1, respectively. Adopting the continuous-flow model for tetracaine hydrochloride, the linear range was 25-300 μg ml−1, and the detection limit was 18.0 μg ml−1 with sampling frequency of 40 h−1. This method has been used to determine metoclopramide and tetracaine hydrochloride in pharmaceutical preparations, and the results are compared with those determined by the pharmacopoeia method. Statistical analysis reveals that there was no evidence of significant difference between the methods.  相似文献   

13.
In the present work, a rapid and sensitive method for simultaneous determination of penicillin G (PG), benzathine (BE) and procaine (PR) in drug and serum media is introduced. The polar hydro-organic (55/45) mobile phases containing an aqueous solution adjusted to pH = 3.7 and an organic solvent (MeOH) including triethylamine (TEA) and trifluroacetic acid (TFA) are used. The flow rate of 1 ml min−1, a C8 column (150 mm × 46 mm) with 5 μm i.d. and wavelength at 215 nm are selected for optimal separation condition. The limit of detection (LOD), linear concentration range and relative standard deviation (R.S.D.) of this method for the PG are 1.1 μg ml−1, 10-2400 μg ml−1 and 1.7% and for the BE are 1.2 μg ml−1, 12-2100 μg ml−1 and 1.8% and for the PR are 1.5 μg ml−1, 20-2000 μg ml−1 and 2%, respectively. The factorial design is used for the determination of main and interaction effects of pH, flow rate and concentration of MeOH, TEA and TFA in the separation at two levels. Also, the analysis of variance (ANOVA) table is obtained. The results show that TFA and TEA have higher effect than concentration of MeOH, pH and flow rate factors.  相似文献   

14.
Chen X  Wang J 《Talanta》2006,69(3):681-685
A sensitive procedure for the quantification of total protein bovine serum albumen (BSA) in human serum was presented with sequential injection sampling and fluorometric detection. A few microliters of sample and fluorescamine solutions were aspirated into the holding coil to facilitate the reaction of protein with fluorescamine by giving rise to a blue-green-fluorescent derivative. The derivative was afterwards excited by a 400 nm radiation from a UV radiator, and the emitted fluorescence was monitored at the wavelength of 470 nm. By loading 5.0 μl of sample and 4.0 μl of fluorescamine solution 0.075% (m/v), a linear calibration graph was obtained within 0.3-12.5 μg ml−1, and a detection limit (3σ) of 0.1 μg ml−1 was achieved, along with a sampling frequency of 40 h−1 and a R.S.D. value of 2.1% at the 5.0 μg ml−1 levels. Protein contents in human serums were analyzed by using the present procedure, and reasonable agreements were obtained with those obtained by a documented spectrophotometric (Biuret) method.  相似文献   

15.
Ruhela R  Sharma JN  B S Tomar  Hubli RC  Suri AK 《Talanta》2011,85(2):1217-1220
A precise, sensitive and selective method for the spectrophotometric determination of palladium (II) using N,N,N′,N′-tetra(2-ethylhexyl) thiodiglycolamide T(2EH)TDGA as an extractant is described. Palladium (II) forms yellow colored complex with T(2EH)TDGA which exhibits an absorption maximum at ∼300 nm. The colored complex obeys Beer's law in the concentration range 1.0-15.0 μg ml−1 of palladium with a molar absorptivity of 1.29 × 105 M−1 cm−1. The effects of various experimental parameters have been studied to establish the optimum conditions for the extraction and determination of palladium. The precision of the method has been evaluated and the relative standard deviation has been found to be less than 0.5%. The method has been successfully applied to the determination of palladium in simulated high level liquid waste (SHLW) solution.  相似文献   

16.
A simple flow injection colourimetric procedure for determining andrographolide was proposed. It is based on the reaction between andrographolide with 3,5-dinitrobenzoic acid, resulting in an intense purplish red complex with a suitable absorption at 536 nm. A standard or sample solution was injected into the 3,5-dinitrobenzoic acid stream (flow rate of 1.0 ml min−1) which was then merged with potassium hydroxide stream with the same flow rate. Optimum conditions for determining andrographolide were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 5.0-150.0 μg ml−1 and the detection limit was 1.50 μg ml−1 (3σ). The relatives standard deviation of the proposed method calculated from 10 replicate injections of 10.0 and 80.0 μg ml−1 andrographolide were 0.66% and 1.64%, respectively. The sample throughput was 50 h−1. The proposed method has been satisfactorily applied to the determination of andrographolide in herb plant samples.  相似文献   

17.
A simple and rapid spectrophotometric method is proposed for the determination of transparent exopolymer particles (TEP) in freshwater samples. In this method, TEP reacts with excess of alcian blue solution yielding a low solubility dye-TEP complex. After centrifugation, the concentration of the remaining dye in the supernatant was determined at 602 nm and its concentration was related to the concentration of TEP in freshwater. The effect of alcian blue concentration from 1.5×10−3 to 9.0×10−3% (m/v), solution pH from 2.5 to 6.9 and stirring time from 20 to 120 s on the analytical curve was investigated. Under the optimum conditions established, such as alcian blue concentration of 3.0×10−3% (m/v); pH of 4.0 (0.2 mol l−1 acetate buffer solution) and stirring time of 1 min, the analytical curve was linear from 0.50 to 10 μg ml−1 (A=0.34−0.037[GX]; r2=0.9999; where A is the absorbance and [GX] the gum xanthan concentration in μg ml−1) with a detection limit of 0.10 μg ml−1. The recovery of TEP (as gum xanthan) for two samples ranged from 95.3 to 108 and the relative standard deviations (R.S.D.s) were lower than 0.8% for gum xanthan solutions at concentrations of 1.0 and 1.5 μg ml−1 (n=8). The results obtained for TEP in freshwater samples using the proposed spectrophotometric method and those obtained using a literature method are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

18.
A flow system was coupled to a graphite furnace with a platform coated with tungsten-rhodium permanent chemical modifier for in-line separation and preconcentration of copper by employing a minicolumn loaded with 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18-bonded silica fixed in the tip of the autosampler arm. Elution was made by sampling 35 μl of 0.50 mol l−1 HCl with further delivering into a coated platform. Remarkable improvements in both selectivity and sensitivity were observed. Copper(II) was effectively separated from solutions containing up to 20 g l−1 Na+; 10 g l−1 K+, Ca2+ and Mg2+; 1.0 g l−1 Fe3+ and Zn2+. For a sample flowing at 3.0 ml min−1 and a loading of 60 s, the detection limit was estimated as 5 ng l−1 Cu(II) at the 99.7% confidence level, and an enrichment factor of 33 was calculated. Coefficient of variation was estimated as 4% for a 0.30 μg l−1 copper solution (n=20). The W-Rh permanent chemical modifier was used to improve system stability, analytical performance and atomizer lifetime. More than 1500 firings were carried out with the same atomizer without significant variations in sensitivity and precision. On account of the reagent immobilization, its consumption was lower than 0.2 μg per determination. In addition, TAN purification was unnecessary.  相似文献   

19.
Yongqiang Cheng  Yuqin Su 《Talanta》2007,71(4):1757-1761
A novel assay of DNA has been proposed by using ferric nanoparticles as probes coupled with resonance light scattering (RLS) detection. At pH 7.40, the RLS intensity of ferric nanoparticles can be greatly enhanced by the aggregation of positively charged ferric nanoparticles through electrostatic interaction with negatively charged DNA. The enhanced intensity of RLS at 452 nm is proportional to the concentration of DNA in the range of 0.01-0.8 μg ml−1 for calf thymus and salmon sperm DNA and in the range of 0.005-0.3 μg ml−1 for E. coli K12 genomic DNA. Detection limits are 3.6 ng ml−1 for calf thymus DNA, 4.4 ng ml−1 for salmon sperm DNA, and 1.9 ng ml−1 for E. coli K12 genomic DNA, respectively. Compared with the chromophores previously used in RLS assay, the ferric nanoparticles have offered several advantages in easy preparation, good photostability and high sensitivity without being modified or functionalized.  相似文献   

20.
Tagitinin C, an antiplasmodial compound, identified as one major compound of the subtropical medicinal plant, Tithonia diversifolia, was determined by FT-IR spectroscopy method. The crude ether extracts from aerial parts of the plant were evaporated to dryness and re-dissolved in tetrachloroethylene (C2Cl4) before analysis.The magnitude of the absorbance of the very specific CO stretching vibration (νCO) at 1664.8 cm−1 was exploited in order to quantify tagitinin C. The determination coefficient (r2) of the calibration scale was 0.9994, the detection limit was lower than 3 μg ml−1 and the quantification limit was lower than 10 μg ml−1.Recovery values from 100.5 to 101.7% were found for spiked concentration levels from 19.91 to 89.95 μg ml−1. The main characteristics of the curves obtained from the calibration standards and from the standard addition technique were not statistically different (Student t-test) suggesting that matrix effects were negligible.The results obtained for the determination of tagitinin C in the crude ether extract from aerial parts of T. diversifolia by LC and FT-IR spectroscopic method agreed well: 0.76±0.02 and 0.773±0.009, of tagitinin C in dried plant respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号