首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two polar benzo[c]phenanthridine alkaloids, chelerythrine (CHE) and dihydrochelerythrine (DHCHE), were extracted at 35 °C and 10 MPa (15 MPa for real samples) from real and spiked plasma samples with acceptable recoveries (95.1% and 81.0%, respectively) using near-critical CO2 modified with aqueous (1:1, v/v) methanol. The alkaloids were quantified by a liquid chromatographic/electrospray mass spectrometric (LC/ESI-MS) method on a Zorbax SB-CN column (75 mm × 4.6 mm, 3.5 μm particle size) using methanol (organic phase) and 50 mM ammonium formiate (aqueous phase) as a mobile phase. A linear gradient 0-1 min, isocratic at 60% organic phase (v/v); from 1.0 to 7.0 min, 60-71% organic phase (v/v); from 7.0 to 18.0 min, 71-60% organic phase (v/v) was applied. The limit of detection was 1.22 ng (3.50 pmol) for CHE and 0.95 ng (2.72 pmol) for DHCHE per 1 ml of the sample. The linearity of the calibration curves was satisfactory as indicated by coefficients of determination 0.9979 and 0.9995 for CHE and DHCHE, respectively. Repeatability and intermediate precision (average R.S.D.s) were 1.0-1.5%, accuracy was in the range 99.7-100.3%. Average recovery was 100.1% for both, standard solutions and spiked plasma extracts. Three samples of real rat plasma were extracted and analysed to test the method.  相似文献   

2.
A Kaddoumi  M Mori  K Nanashima  M Kono  K Nakashima 《The Analyst》2001,126(11):1963-1968
A simple and convenient high performance liquid chromatographic method with UV detection is described for the determination of mazindol [5-(p-chlorophenyl)-2,5-dihydro-3H-imidazo[2,1-a]isoindol-5-ol] and its major metabolite, 2-(2-aminoethyl)-3-(p-chlorophenyl)-3-hydroxyphthalimidine (Met), in human plasma. The analytes were extracted with ethyl acetate from plasma samples and separated on a C18 column using acetonitrile-0.067 mol dm(-3) phosphate buffer (pH 3.5) (24 + 76 v/v) as a mobile phase. The eluates were monitored at 220 nm. Following complete validation and stability studies, the proposed method proved to be sensitive and precise. The limits of detection were 0.07 and 0.08 ng ml(-1) of plasma for mazindol and Met, respectively. The accuracy and recovery were in the ranges 94-102% and 91-102%, respectively, for both compounds. The intra- and inter-assay precisions were less than 7.6 and 9.2%, respectively, for both compounds. The stability of mazindol under different storage conditions, i.e., at room temperature (rt) and 4 degrees C and with freeze-thaw cycles, was also examined. Mazindol was unstable in plasma samples left at rt and 4 degrees C. The method was applied to the determination of mazindol and Met in the plasma of a patient treated for obesity with mazindol.  相似文献   

3.
A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL−1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

4.
Zhifeng Tu  Lijun Zhang  Qun He  Jianping Shi  Ru Gao 《Talanta》2010,80(3):1205-1747
A new method that utilizes 1-(2-aminoethyl)-3-phenylurea-modified silica gel as a solid-phase extractant has been developed for preconcentration of trace Sc(III) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace level of Sc(III) were optimized using batch and column procedures in detail. The optimum pH value for the separation of Sc(III) on the new sorbent was 4 and complete elution of Sc(III) from the sorbent surface was carried out using 1.0 mL of 0.1 mol L−1 HCl. Common coexisting ions did not interfere with the separation and determination of the analyte. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 32.5 mg g−1 while the time of 95% adsorption was less than 2 min. The detection limit of present method was found to be 0.091 μg g−1, and the relative standard deviation (RSD) was lower than 3.0% (n = 8). The method was successfully applied for the preconcentration of trace Sc(III) in the environmental samples with satisfactory results.  相似文献   

5.
Dongling L  Xiaoyan H  Haizhou W 《Talanta》2004,63(2):233-237
A method for the simultaneous determination of Nb and Ta in steel and alloy by reversed-phase high-performance liquid chromatography (RP-HPLC) was proposed. 2-(5-Bromo-2-pyridylazo)-5-diethylamino phenol (5-Br-PADAP) was used as a pre-column chelating agent to form a ternary complex with Nb(V) and Ta(V) and tartaric acid. The ternary complexes of Nb(V) and Ta(V) were eluted within 8 min on a C18 column with a mobile phase of methanol-water (55:45, v/v) containing 10 mmol l−1 acetate buffer (pH3.5) and determined with spectrophotometric detection at 598 nm. The detection limits for Nb(V) and Ta(V) were 0.60 and 0.72 μg l−1, respectively, when the ratio of signal-to-noise is 3. The proposed method was used to analyze Nb and Ta in cast iron, alloy and stainless steel.  相似文献   

6.
Khuhawar MY  Arain GM 《Talanta》2005,66(1):34-39
Spectrophotometric and high performance liquid chromatographic (HPLC) methods have been developed for the determination of cis-platin and carboplatin based on the pre-column derivatization of platinum(II) with 2-acetylpyridine-4-phenyl-3-thiosemicarbazone. The complex was extracted in chloroform with molar absorptivity of 2.2 × 104 L mol−1 cm−1 at 380 nm. The complex eluted from a Phenomenex C-18 (150 mm × 4.6 mm i.d.) column with methanol:water:acetonitrile:tetrabutyl ammonium bromide (1 mM) (44:30:25:1, v/v/v/v) with a flow rate of 1 ml/min and UV detection at 260 nm. Ruthenium(IV) and selenium(IV) also separated completely. The linear calibration curve was with 0.5-12.5 μg/ml and detection limit of 10 ng/ml platinum(II).The analysis of cis-platin and carboplatin injections by spectrophotometric and HPLC methods indicated relative standard deviation (R.S.D.) of 0.66-2.1%. The method was used for the determinations of cis-platin in serum and urine of cancer patients after chemotherapy and platinum contents were found 148-444 and 50-90 ng/ml with R.S.D. of 0.3-3.0 and 0.6-2.4% for the serum and urine, respectively. The recovery of platinum(II) from serum was 97% with R.S.D. 2.2%.  相似文献   

7.
Wei Li 《Talanta》2007,71(1):385-390
A novel high-performance liquid chromatographic (HPLC) method using pre-column derivatization and UV detection at 275 nm for the determination of clarithromycin in rat plasma has been validated. Clarithromycin was extracted from plasma sample spiked with internal standard (erythromycin) under alkaline condition with ethyl ether and derivatizated with trimethylbromosilane. The analyses were run on a C18 column, maintained at 40 °C during elution, using a mobile phase comprised of potassium dihydrogen phosphate (50 mM, pH 6.8, contained 0.7% triethylamine), acetonitrile, and methanol (30:45:25, v/v/v). The standard calibration curve for clarithromycin was linear (r2 = 0.9998) over the concentration range of 0.1-10 μg ml−1 in rat plasma. The limit of detection (LOD) and limit of quantitation (LOQ) was 30 ng ml−1 and 0.1 μg ml−1 respectively. The intra- and inter-day assay variability range was 2.6-7.4% and 3.3-8.5%, respectively. This method has been successfully applied to a pharmacokinetic study of clarithromycin in rats.  相似文献   

8.
We developed a method for simultaneously determining naltrexone, an opioid antagonist, and its major metabolite (6-β-naltrexol) in plasma using LC/MS/MS. Three compounds, and naloxone as an internal standard, were extracted from plasma using a mixture of methyl-tertiary-butyl ether. After drying the organic layer, the residue was reconstituted in a mobile phase (0.1% formic acid-acetonitrile:0.1% formic acid buffer, 95:5, v/v) and injected onto a reversed-phase C18 column. The isocratic mobile phase was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring modes were m/z 342 → 324, 344 → 326, and 328 → 310 for naltrexone, 6-β-naltrexol, and naloxone, respectively. The coefficient of variation of the assay precision was less than 11.520%, and the accuracy exceeded 93.465%. The limit of quantification was 2 ng/ml for naltrexone and 7.2 ng/ml for 6-β-naltrexol. And the limit of detection was 0.1 ng/ml for naltrexone and 0.36 ng/ml for 6-β-naltrexol. This method was used to measure the plasma concentration of naltrexone and 6-β-naltrexol in healthy subjects after a single oral 50 mg dose of naltrexone. This analytical method is a simple, sensitive, and accurate way of determining the pharmacokinetic profiles of naltrexone and its metabolites. The pharmacokinetic parameters were analyzed using both non-compartmental analysis performed for each subject according to standard methods and compartmental analysis with a parent-metabolite pharmacokinetic model that was fitted to the data, simultaneously, using the program ADAPT II. The tested parent-metabolite pharmacokinetic model successfully described the relationship between the plasma concentration of naltrexone and one of its major metabolites, 6-β-naltrexol.  相似文献   

9.
Baytak S  Zereen F  Arslan Z 《Talanta》2011,84(2):319-323
A trace element preconcentration procedure is described utilizing a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination of Cr, Cu, Fe, Mn, Ni and Zn from water samples by inductively coupled plasma atomic emission spectrometry. The elements were quantitatively retained on the column between pH 6 and 8. Elution was made with 5% (v/v) HNO3 solution. Recoveries ranged from 98 ± 2 (Cr) to 100 ± 4 (Zn) for preconcentration of 50 mL multielement solution (50 μg L−1). The column made up of 100 mg sorbent (yeast immobilized TiO2 NP) offers a capacity to preconcentrate up to 500 mL of sample solution to achieve an enrichment factor of 250 with 2 mL of 5% (v/v) HNO3 eluent. The detection limits obtained from preconcentration of 50 mL blank solutions (5%, v/v, HNO3, n = 11) were 0.17, 0.45, 0.25, 0.15, 0.33 and 0.10 μg L−1 for Cr, Cu, Fe, Mn, Ni and Zn, respectively. Relative standard deviation (RSD) for five replicate analyses was better than 5%. The retention of the elements was not affected from up to 500 μg L−1 Na+ and K+ (as chlorides), 100 μg L−1 Ca2+ (as nitrate) and 50 μg L−1 Mg2+ (as sulfate). The method was validated by analysis of freshwater standard reference material (SRM 1643e) and applied to the determination of the elements from tap water and lake water samples.  相似文献   

10.
Li G  Ji Z  Wu K 《Analytica chimica acta》2006,565(2):178-182
In the study, we developed a simple, rapid and sensitive method for the determination of tiopronin (TP) in human plasma, which was based on derivatization with p-bromophenacyl bromide (p-BPB) followed by liquid-liquid extraction and reverse-phase HPLC-UV detection. For the first time, the p-BPB was introduced into the derivatization of TP. The thiol group of TP was trapped with p-BPB to form a TP-p-BPB adduct, which can be very suitable for UV detection. From acidified plasma samples, the derivatized TP was extracted with 5 mL dichloromethane. Effective chromatographic separation was achieved using a C18 column (DIAMONSIL 150 mm × 4 mm i.d., 5 μm) based on an acetonitrile-water-trifluoroacetic acid (40:59.88:0.12, v/v/v) elution at a flow-rate of 1 mL/min. The IS and the derivatized TP were detected at 263 nm. No endogenous substances were found to interfere. The limit of quantification for derivatized TP (TP-p-BPB) in plasma was 40 ng/mL. The calibration curve for the derivatized TP showed linearity in the range 0.04-4 μg/mL with a regression coefficient corresponding to 0.9991 and the coefficient of the variation of the points of the calibration curve being lower than 10%. Extraction recoveries of the derivatized TP in plasma were greater than 72%. The method was suitably validated and successfully applied to determination of TP in human plasma samples.  相似文献   

11.
Cylindrospermopsin (CYN) was determined by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS) using 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES) as the internal standard. In the selected ion monitoring of LC/ESI-MS, m/z 414 for CYN and 237 for HEPES were monitored using the negative mode; the retention times of CYN and HEPES were 12.41 and 14.21 min, respectively. CYN was determined from peak area ratios of m/z 414/237. By the treatment of an anion exchange cartridge using a buffer at pH 10.5, CYN was isolated and condensed. No interfering peak was observed. Linearity of this method was observed at the range of 0.10-31.12 ng. Total coefficients of variation were 5.1 and 2.9% at 104 and 1038 μg CYN L−1. The quantitative limit at a signal-to-noise (S/N) ratio of 10 was 0.16 ng.CYN concentration in natural waters is low. CYN in waters should be condensed for determination. This method including the treatment for isolation and condensation of CYN is useful for determination of CYN in environmental and/or drinking waters.  相似文献   

12.
The chiral separation of 10 β-adrenergic blockers (acebutalol, alprenolol, bufuralol, bisoprolol, celiprolol, carazolol, indenolol, metoprolol, oxprenolol and propranolol) was achieved on CelluCoat column (250 mm × 4.6 mm, 5 μm particle size). The mobile phases used were (90:10:0.2, v/v/v) and (95:5:0.2, v/v/v) combinations of n-heptane-ethanol-diethylamine, respectively. The flow rates were 0.5, 1.0 and 2.0 mL min−1 with detection at 225 nm. The capacity (k), selectivity (α) and resolution (Rs) factors were 0.44-12.91, 1.12-2.19 and 1.00-9.50, respectively. The proposed supra-molecular models indicated that the chiral resolution were governed by π-π interactions, hydrogen bondings and steric effect.  相似文献   

13.
A new simple, sensitive and selective liquid chromatography coupled with mass spectrometry (LC/MS) method for quantification of captopril after precolumn derivatization with p-bromo-phenacyl-bromide in human plasma was validated. Plasma samples were analysed on a monolithic column (Cromolith Performance-RP 18e, 100 mm × 4.6 mm I.D., 3 μm) under isocratic conditions using a mobile phase of a 40:60 (v/v) mixture of acetonitrile and 0.1% (v/v) formic acid in water. The flow rate was 1 mL/min at the column temperature of 30 °C. In these chromatographic conditions, the retention time was 4.4 min for captopril derivative. The detection of the analyte was in MRM mode using an ion trap mass spectrometer with electrospray positive ionisation. The monitored ions were 216, 253, 255, 268, 270 m/z derived from 415 m/z for derivatized captopril. The sample preparation was very simple and consisted in plasma protein precipitation from 0.2 mL plasma using 0.3 mL methanol after the derivatization reaction was completed. Calibration curves were generated over the range of 10-3000 ng/mL with values for coefficient of correlation greater than 0.993 and by using a weighted (1/y2) quadratic regression. The values for precision (CV %) and accuracy (relative error %) at quantification limit were less than 9.9% and 3.9%, for within- and between-run, respectively. The mean recovery of the analyte was 99%. Derivatized samples demonstrated good short-term, long-term, post-preparative and freeze-thaw stability. This is the first reported LC-MS/MS method for analysis of captopril in human plasma that uses protein precipitation as sample processing procedure. The method is very simple and allows obtaining a very good recovery of the analyte. The validated LC-MS/MS method has been applied to a pharmacokinetic study of 50 mg captopril tablets on healthy volunteers.  相似文献   

14.
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma.  相似文献   

15.
A procedure for the extraction and determination of methyl mercury and mercury (II) in fish muscle tissues and sediment samples is presented. The procedure involves extraction with 5% (v/v) 2-mercaptoethanol, separation and determination of mercury species by HPLC-ICPMS using a Perkin-Elmer 3 μm C8 (33 mm × 3 mm) column and a mobile phase 3 containing 0.5% (v/v) 2-mercaptoethanol and 5% (v/v) CH3OH (pH 5.5) at a flow rate 1.5 ml min−1 and a temperature of 25 °C. Calibration curves for methyl mercury (I) and mercury (II) standards were linear in the range of 0-100 μg l−1 (r2 = 0.9990 and r2 = 0.9995 respectively). The lowest measurable mercury was 0.4 μg l−1 which corresponds to 0.01 μg g−1 in fish tissues and sediments. Methyl mercury concentrations measured in biological certified reference materials, NRCC DORM - 2 Dogfish muscle (4.4 ± 0.8 μg g−1), NRCC Dolt - 3 Dogfish liver (1.55 ± 0.09 μg g−1), NIST RM 50 Albacore Tuna (0.89 ± 0.08 μg g−1) and IRMM IMEP-20 Tuna fish (3.6 ± 0.6 μg g−1) were in agreement with the certified value (4.47 ± 0.32 μg g−1, 1.59 ± 0.12 μg g−1, 0.87 ± 0.03 μg g−1, 4.24 ± 0.27 μg g−1 respectively). For the sediment reference material ERM CC 580, a methyl mercury concentration of 0.070 ± 0.002 μg g−1 was measured which corresponds to an extraction efficiency of 92 ± 3% of certified values (0.076 ± 0.04 μg g−1) but within the range of published values (0.040-0.084 μg g−1; mean ± s.d.: 0.073 ± 0.05 μg g−1, n = 40) for this material. The extraction procedure for the fish tissues was also compared against an enzymatic extraction using Protease type XIV that has been previously published and similar results were obtained. The use of HPLC-HGAAS with a Phenomenox 5 μm Luna C18 (250 mm × 4.6 mm) column and a mobile phase containing 0.06 mol l−1 ammonium acetate (Merck Pty Limited, Australia) in 5% (v/v) methanol and 0.1% (w/v) l-cysteine at 25 °C was evaluated as a complementary alternative to HPLC-ICPMS for the measurement of mercury species in fish tissues. The lowest measurable mercury concentration was 2 μg l−1 and this corresponds to 0.1 μg g−1 in fish tissues. Analysis of enzymatic extracts analysed by HPLC-HGAAS and HPLC-ICPMS gave equivalent results.  相似文献   

16.
Kishida K  Furusawa N 《Talanta》2005,67(1):54-58
A simultaneous determination of sulfamonomethoxine, sulfadimethoxine, and their hydroxy/N4-acetyl metabolites in chicken plasma, muscle, liver, and eggs using gradient high-performance liquid chromatography (HPLC) with a photo-diode array detector is developed. All the compounds are extracted by a handheld ultrasonic homogenizer with ethanol followed by centrifugation. The separation is performed by a reversed-phase C4 column with a gradient elution (ethanol:1% (v/v) acetic acid, v/v; 10:90 → 20:80). Average recoveries from samples spiked at 0.1-1.0 μg g−1 or μg ml−1 for each drug were >90% with relative standard deviations within 4%. The limits of quantitation were <30 ng g−1 or ng ml−1.  相似文献   

17.
Khuhawar MY  Arain GM 《Talanta》2006,68(3):535-541
Liquid chromatographic method has been developed, based on precolumn derivatization of vanadium(V) with 2-acetylpyridine-4-phenyl-3-thiosemicarbazone (APPT). The complex is extracted in chloroform together with palladium(II), tin(II) and iron(III) and eluted and separated completely from Kromasil 100 C-18, 10 μm (25 cm × 4.6 mm i.d.) column with methanol:water:acetonitrile (60:30:10, v/v/v) with a flow rate of 1 ml/min. UV detection was at 260 nm. Linear calibration curve was obtained with 1-12.5 μg/ml vanadium(V) with detection limit of 8 ng/injection (20 μl). A number of metal ions tested did not affect the determination of vanadium. The test mixtures were analyzed for vanadium(IV) and vanadium(V) contents and relative% error was obtained ±1-8%. The method was applied for the determination of vanadium in petroleum oils and mineral ore samples with vanadium contents of 0.32-2.3 and 121.7-717.3 μg/g with R.S.D. of 1.5-4.5 and 0.38-4.7%, respectively. The results correlated with reported values and by atomic absorption spectrophotometry.  相似文献   

18.
Nasr Y. Khalil 《Talanta》2010,80(3):1251-1256
A fully automated, rapid and highly sensitive HPLC method with automated sample pre-treatment by column-switching system and fluorescence detection has been developed for the trace quantitative determination of the new antidepressant reboxetine (RBX) in human plasma. A simple pre-column derivatization procedure with 7-flouro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) reagent was employed. Paroxetine (PXT) was used as an internal standard. Plasma samples containing both RBX and PXT, after filtration, were derivatized by heating with NBD-F in borate buffer of pH 8 at 70 °C for 30 min. The derivatized plasma samples were injected into the HPLC system where an on-line sample clean up was achieved on the pre-treatment column (Co-sense Shim-pack MAYI-ODS) with a washing mobile phase (acetonitrile:2% acetic acid; 40:60, v/v) at a flow rate of 5 mL min−1 for 1 min. After an automated on-line column switching to the analytical Hypersil phenyl 120A column (250 mm × 4.6 mm, 5 μm), the separation of the derivatized RBX and PXT was performed using a mobile phase consisting of sodium acetate buffer (pH 3.5):tetrahydrofuran:acetonitrile (55:35:10, v/v/v) at a flow rate of 2.0 mL min−1. The eluted derivatives were monitored by a fluorescence detector set at an excitation wavelength of 470 nm and an emission wavelength of 530 nm. Under the optimum chromatographic conditions, a linear relationship with good correlation coefficient (r = 0.9995, n = 5) was found between the peak area ratio of RBX to PXT and RBX concentration in the range of 2-500 ng mL−1, with limits of detection and quantification of 0.5 and 1.7 ng mL−1, respectively. The intra- and inter-day precisions were satisfactory; the relative standard deviations were 2.25 and 3.01% for the intra- and inter-day precisions, respectively. The accuracy of the method proved as the mean recovery values were 100.11 ± 2.24% and 100.99 ± 2.98% for the intra- and inter-day assay runs, respectively. The proposed method involved simple and minimum sample preparation procedure and short run-time (<12 min) and therefore it can be applied to the routine therapeutic monitoring and pharmacokinetic studies of RBX.  相似文献   

19.
A fast high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of mianserin (MIAN) and its metabolites desmethylmianserin (DMM), 8-hydroxymianserin (HM) and mianserin-N-oxide (MNO) in human plasma. Each compound, together with internal standard (propranolol) was extracted from the plasma matrix using solid phase extraction. Chromatographic resolution of the analytes was performed on a Chromolith Speed Rod monolithic silica column ( mm i.d.) under isocratic conditions using a mobile phase of 74:26 (v/v) 25 mM phosphate buffer (pH 5.3 adjusted with phosphoric acid): acetonitrile. The elution of the analytes were monitored at 292 mm and conducted at ambient temperature. Because of high column efficiency the mobile phase was pumped at a flow rate of 3.5 ml/min. The total run time of the assay was 5 min. The method was validated over the range of 10-200 ng/ml for MIAN, 10-150 ng/ml for DMM, 20-300 ng/ml for HM and 25-500 ng/ml for MNO. The method proved to be precise (within-run precision ranging from 1.6 to 6.9% R.S.D. and between-run precision ranging from 1.3 to 7.2% R.S.D.) and accurate (within-run accuracies ranged from 1.4 to 6.4% and between-run accuracies ranging from 1.5 to 4.5%). The mean absolute recoveries were 95.7, 94.8, 99.6, and 102.6% for MIAN, DMM, HM and MNO, respectively. The limit of quantitation (LOQ) for MIAN and DMM was 10 ng/ml and for HM and MNO were 20 and 25 ng/ml in human plasma, respectively. The limit of detection (LOD) for MIAN, DMM, HM and MNO was 5, 2.5, 10 and 15 ng/ml, respectively. The described method demonstrates the feasibility for employing monolithic columns to effect rapid bioanalytical HPLC analysis for the quantitative determination of MIAN and its major metabolites in human plasma.  相似文献   

20.
A simple and sensitive high-performance liquid chromatographic (HPLC) method was developed for quantification of aceclofenac in rat plasma. Ibuprofen was used as an internal standard (IS). The present method used protein precipitation for extraction of aceclofenac from rat plasma. Separation was carried out on reversed-phase C18 column (250 mm × 4.6 mm, 5 μ) and the column effluent was monitored by UV detector at 282 nm. The mobile phase used was methanol-triethylamine (pH 7.0; 0.3% v/v in Milli-Q water) (60:40%, v/v) at a flow rate of 1.0 mL min−1. This method was linear over the range of 50.0-3500.0 ng mL−1 with regression coefficient greater than 0.99. The mean recovery of aceclofenac and IS were 84.62 ± 3.23 and 89.19 ± 1.57%, respectively and the method was found to be precise, accurate, and specific during the study. The method was successfully applied for pharmacokinetic study of aceclofenac in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号