首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A previously elaborated capillary electrophoresis (CE) method used for the determination of glyphosate and aminomethylphosphonic acid (AMPA) was slightly modified in order to improve the sensitivity. However, detection limits attained (5 μg mL−1 for glyphosate and 4 μg mL−1 for AMPA) were still not satisfactory for analytical purposes, thus the addition of a preconcentration step before the CE analysis was proposed. AMBERLITE®IRA-900, a strong anion-exchange resin, was used to preconcentrate both analytes in environmental aqueous samples. The experimental conditions optimised in a previous work were readapted, by decreasing the eluent concentration due to CE limitations. Satisfactory results were attained when spiked ultrapure water was applied, with recoveries from 84 to 87% for glyphosate (R.S.D. < 6%) and from 85 to 98% for AMPA (R.S.D. < 5%). Enrichment factors up to 65 were achieved with this system, allowing the determination of 85 ng mL−1 of glyphosate and 60 ng mL−1 of AMPA. The extraction efficiency varied when four different natural water samples of varying conductivity were applied. Especially the strong dependence on ion concentration in samples on AMPA recovery was found. For glyphosate, good recoveries (86-99%) were obtained for samples of low and medium conductivity (0-800 μS). The effect of sample salt content on extraction efficiency was studied and a linear relationship could be established for AMPA (r2 = 0.996). An important improvement on recoveries was observed when lower volumes of sample were treated.A HPLC method with UV-vis detection and pre-column derivatisation with p-toluensulphonyl chloride was compared to the CE method. No significant differences in results were found when t- and F-statistical tests were applied.  相似文献   

2.
This paper presents the application of ion chromatography with electrolytic eluent generation and mobile phase suppression for the direct conductimetric detection of glyphosate and its degradation product aminomethylphosphonic acid (AMPA). The compounds were separated on a Dionex AS18 anion exchange column with a 12–40 mM KOH step gradient from 9 to 9.5 min. The effect of the suppressor current intensity on the electrostatic interaction of these amphoteric compounds with the suppressor cation exchange membranes was evaluated. A suppressor current gradient technique was proposed for the limitation of peak broadening and baseline noise, in order to improve method sensitivity and detectability. It was observed that residual sample carbonates co-eluted with AMPA when a large injection loop was installed for the low level determination of both compounds in natural waters. For this reason, glyphosate was isocratically eluted using 33 mM KOH in order to decrease analysis time within 10 min and a column clean up step using 100 mM KOH was used to ensure retention time reproducibility. The developed method was applied to the analysis of drinking and natural water and it was further successfully applied to orange samples with slight modifications. Instrumental LOD for glyphosate was 0.24 μg/L, while method LOD was 0.54 μg/L for spring waters and 0.01 mg/kg for oranges using a 1000 μL direct loop injection of the sample. Intra-day and inter-day precision (as %RSD) for water samples was 4.6% and 12% at a spiking level of 2 μg/L, and the recovery ranged from 64% to 88% depending on sample conductivity. For orange samples, the inter-day precision was 1.4% at a spiking level of 4.4 mg/kg, while overall recovery was 103%. The developed method is direct, fast, sensitive and relatively inexpensive, and could be used as an ideal fast screening tool for the monitoring of glyphosate residues in water and fruit samples.  相似文献   

3.
The herbicides amitrole and glyphosate, and its metabolite aminomethyl-phosphonic acid (AMPA), in water samples have been directly analysed by high-performance liquid chromatography using an electrochemical (EC) detector. Limits of detection of 0.3 μg mL−1 for glyphosate, 0.05 μg mL−1 for AMPA and 0.03 μg mL−1 for amitrole were comparable to those obtained by other authors using EC and also by liquid chromatography coupled to mass spectrometry, but the latter method requires derivatisation and pre-concentration of the sample whereas EC methods show similar sensitivity without the need of any derivatisation. The method was specifically designed to analyse extracts from passive samplers used for monitoring of polar herbicide residues in waters. To this purpose, three types of Empore® disks were tested for their ability to adsorb and desorb these ionic, polar analytes. A procedure for their extraction from the membranes and reducing the interferences from other substances present in natural waters (i.e. humic acids) is described. The method is simple, does not require sophisticated equipment and is valid for the analysis and monitoring of herbicides residues using passive samplers.  相似文献   

4.
An isocratic HPLC method for the determination with screening purposes of anabolic androgenic steroids (AASs: fluoxymesterone, boldenone, nortestosterone, metandrostenolone, norethindrone, methyltestosterone and bolasterone), used as growth promoting agents, in finishing pig feed samples has been developed and validated. The separation was achieved by using a reversed-phase Chromolith RP-18e column at controlled temperature, UV-detection at 245 nm and epitestosterone as internal standard. The method development involved optimization of different aqueous-organic mobile phases using methanol or acetonitrile as organic modifiers, flow-rate and temperature. The optimum separation for these compounds was achieved at 40 °C using ultrapure water:acetonitrile (71:29, v/v) as mobile phase and 3 mL min−1 flow-rate, allowing the separation of AASs with baseline resolution in about 15 min. The optimized method was applied to the analysis of AASs in finishing pig feed samples. Prior to HPLC, sample preparation procedure was used by leaching using acetonitrile, saponification in a basic medium and solid-phase extraction using polymeric Abselut Nexus cartridges. Method validation has been carried out according to the European Commission Decision 2002/657/EC. The extraction efficiencies, decision limits (CCα) and detection capabilities (CCβ) for these compounds were in the range 83-96%, 27-37 and 32-47 μg kg−1 range, respectively. The within-laboratory reproducibility at 1, 1.5 and 2 CCβ concentration levels were smaller than 13, 10 and 8%, respectively. Finally, the proposed method was successfully applied to nine different kinds of animal feed.  相似文献   

5.
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of triptolide. Triptolide was separated from skin endogenous and blank matrices on a 5 μm LiChrospher RP-C18 column by a mobile phase of methanol-water (65:35, v/v). The permeation samples were injected directly without pretreatment. The limit of quantitation (LOQ) and detection (LOD) for triptolide in permeation samples were far below (0.01 and 0.005 μg/mL, respectively). The method was linear over the range of 0.1-104.2 μg/mL with r2 = 0.9999. This HPLC assay is promising for measuring in vitro percutaneous penetration of triptolide through mice skins and also can be performed in the triptolide-loaded microemulsions formulation screening.  相似文献   

6.
A simple and rapid analytical method was developed for the determination of phthalates, usually employed in nail cosmetic products. The method is based on an ultrasonic extraction of the sample with ethanol-water (90:10, v/v) followed by HPLC separation and quantitation. HPLC was carried out using a C18 column and spectrophotometric detection at 254 nm. A linear gradient elution was performed with ethanol-water starting from 50 to 95% ethanol in 30 min. Standard calibration curves were linear for all the analytes over the concentration range 5-200 μg ml−1 with LOD values of about 0.5 μg ml−1.The proposed green analytical method has been successfully applied for the analysis of commercial samples in order to check the presence of phthalates and to determine their concentration.  相似文献   

7.
A novel reversed-phase HPLC method for the simultaneous determination of active component terbinafine, its one impurity 1-methylaminomethylnaphtalene and three degradation products, β-terbinafine, Z-terbinafine and 4-methyl-terbinafine occurring in pharmaceutical formulations after long-term stability tests, was developed and validated using propylparaben as an internal standard.The chromatographic separation was performed on a NUCLEOSIL 100-5-CN column, mobile phase for separation of all compounds consisted of a mixture of tetrahydrofurane, acetonitrile and citrate buffer pH 4.50 (10:20:70, v/v/v). The analysis time was less than 32 min at flow-rate of 0.8 ml min−1. UV detection was performed at 226 nm. The method was validated and system suitability parameters were investigated. Method robustness and short-term standard solution stability were verified. Limits of detection for terbinafine degradation products/impurity were from 0.023 to 0.098 μg ml−1, limits of quantitation were from 0.078 to 0.327 μg ml−1. The method was applicable for routine determination of terbinafine and all its found impurities of similar structure with sufficient selectivity, precision and accuracy.  相似文献   

8.
Ahmed S  Atia NN  Mohamed NA 《Talanta》2011,84(3):666-672
A simple, reproducible and efficient dual separation mode high performance liquid chromatographic (HPLC) method was developed for simultaneous determination of antihypertensive drug combinations including; hydrochlorothiazide (HCTZ), valsartan (VAL), amiloride (AML) and captopril (CAP). The newly developed Platinum™ column, which provides a dual-mode separation with its polar and non-polar sites, was used for rapid separation of these co-administered drugs. Good resolution was obtained when Platinum™ column was used compared with C18 column. Additionally, simple isocratic mode with mobile phase containing methanol and 0.02 mole L−1 phosphate buffer adjusted to pH 3.0 (45:55, v/v) was used for separation. The flow rate was 0.5 mL min−1 and effluent was monitored at 270 nm. All the investigated drugs were completely separated within less than 6 min. The linearity range obtained for the developed HPLC method was 0.5-100 μg mL−1 with detection limits of 0.13-1.2 μg mL−1 for all the studied drugs. The method was validated in accordance with the requirements of ICH guidelines and shown to be suitable for intended applications. The method was successfully used for determination of the studied drugs in pure form and pharmaceutical dosage forms without prior need for separation. The method is valuable for quality control laboratories for simultaneous determination of these co-administered antihypertensive drugs in binary, ternary and quaternary mixtures.  相似文献   

9.
Manuela Kim 《Talanta》2007,72(3):1054-1058
A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50 mm × 4.00 mm i.d., 15 μm particle size, functional group: quaternary ammonium salt) with Na2SO4 0.0075 M (pH 11.5) (flow rate: 1.0 mL min−1) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5 M in a thermostatized bath at 95 °C. Detection was performed at 546 nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k = 3) calculated for 10 blank replicates was 0.04 mg L−1 (0.8 mg kg−1) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.  相似文献   

10.
Wei Li 《Talanta》2007,71(1):385-390
A novel high-performance liquid chromatographic (HPLC) method using pre-column derivatization and UV detection at 275 nm for the determination of clarithromycin in rat plasma has been validated. Clarithromycin was extracted from plasma sample spiked with internal standard (erythromycin) under alkaline condition with ethyl ether and derivatizated with trimethylbromosilane. The analyses were run on a C18 column, maintained at 40 °C during elution, using a mobile phase comprised of potassium dihydrogen phosphate (50 mM, pH 6.8, contained 0.7% triethylamine), acetonitrile, and methanol (30:45:25, v/v/v). The standard calibration curve for clarithromycin was linear (r2 = 0.9998) over the concentration range of 0.1-10 μg ml−1 in rat plasma. The limit of detection (LOD) and limit of quantitation (LOQ) was 30 ng ml−1 and 0.1 μg ml−1 respectively. The intra- and inter-day assay variability range was 2.6-7.4% and 3.3-8.5%, respectively. This method has been successfully applied to a pharmacokinetic study of clarithromycin in rats.  相似文献   

11.
Three methods are presented for the simultaneous determination of lamivudine and zidovudine. The first method depends on first derivative UV spectrophotometry, with zero-crossing and peak-to-base measurement. The first derivative amplitudes at 265.6 and 271.6 nm were selected for the assay of lamivudine and zidovudine, respectively. The second method depends on first derivative of the ratio-spectra by measurements of the amplitudes at 239.5 and 245.3 nm for lamivudine and 225.1 and 251.5 nm for zidovudine. Calibration graphs were established for 1-50 μg/ml for lamivudine and 2-100 μg/ml for zidovudine. In the third method (HPLC), a reversed-phase column with a mobile phase of methanol:water:acetonitrile (70:20:10 (v/v/v)) at 0.9 ml/min flow rate was used to separate both compounds with a detection of 265.0 nm. Linearity was obtained in the concentration range of 0.025-50 μg/ml for lamivudine and 0.15-50 μg/ml for zidovudine. All of the proposed methods have been extensively validated. These methods allow a number of cost and time saving benefits. The described methods can be readily utilized for analysis of pharmaceutical formulations. There was no significant difference between the performance of all of the proposed methods regarding the mean values and standard deviations. The described HPLC method showed to be appropriate for simultaneous determination of lamivudine and zidovudine in human serum samples.  相似文献   

12.
A simple, precise, accurate and validated, acetonitrile-free, reverse phase high performance liquid chromatography (HPLC) method is developed for the determination of melamine in dry and liquid infant formula. The separation is performed on a Kromasil C18 column (150 mm × 3.2 mm I.D., 5 μm particle size) at room temperature. The mobile phase (0.1% TFA/methanol 90:10) is pumped at a flow rate of 0.3 mL min−1 with detection at 240 nm. Melamine elutes at 3.7 min. A linear response (r > 0.999) is observed for samples ranging from 1.0 to 80 μg mL−1. The method provides recoveries of 97.2-101.2% in the concentration range of 5-40 μg mL−1, intra- and inter-day variation in <1.0% R.S.D. The limit of detection (LOD) and limit of quantification (LOQ) values are 0.1 μg mL−1 and 0.2 μg mL−1, respectively.  相似文献   

13.
A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2 min at 70 °C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25 °C and the surfactant rich phase was desorbed with 400 μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066 mg L−1 curcumin and a linear range of 0.22–100 mg L−1 with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples.  相似文献   

14.
Ning Sun  Guocai Lu  Mei Lin  Yutian Wu 《Talanta》2009,78(2):506-1470
MCC-555 is a novel thiazolidinedione which reduces plasma glucose concentrations in Type 2 diabetes mellitus models due to enhancement of insulin sensitivity. A highly sensitive and selective quantitative method to accurately determine MCC-555 in rat plasma is crucial to the success of pharmacokinetic studies of MCC-555. To this purpose we have developed and validated a high-throughput method in a 96-well plate format using ultra-fast liquid chromatography (Shimadzu Prominence UFLC™ system) for the determination of MCC-555 in rat plasma. MCC-555 along with the internal standard resveratrol was extracted from 50 μl of rat plasma by liquid-liquid extraction using ethyl acetate. Baseline separation of MCC-555 and resveratrol was achieved using UFLC technology on a C18 stationary-phase column with 2.2 μm particle size. The influences of flow rate, column temperature and mobile phase pH on chromatographic performance were investigated. Comparing to the conventional HPLC method, UFLC showed many advantages including reduced run time, less solvent consumption and increased sensitivity. The UFLC method was sensitive with a lower limit of quantification of 0.002 μg/ml, with good linearity (r > 0.999) over the linear range of 0.002-2.0 μg/ml. The intra- and inter-run precision was less than 8.6% and accuracy ranged from −6.4 to 8.2% for quality control samples. The extraction recovery from plasma was no less than 80%. The validation and sample analysis results show that the method is precise, accurate and well suited to support pharmacokinetic studies in rats involving three dose administrations.  相似文献   

15.
The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of an fast analysis method for the most relevant soy isoflavones. A step-by-step strategy was used to optimize temperature (25-50 °C), flow rate (1.2-2.7 mL/min), mobile phase composition and equilibration time (1-5 min). Optimized conditions provided a method for the separation of all isoflavones in less than 5.8 min and total analysis time (sample-to-sample) of 11.5 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity, peak symmetry and low limits of detection and quantification levels. The use of a fused-core column allows highly efficient, sensitive, accurate and reproducible determination of isoflavones with an outstanding sample throughout and resolution. The developed method was validated with different soy samples with a total isoflavone concentration ranging from 1941.53 to 2460.84 μg g−1 with the predominant isoflavones being isoflavone glucosides and malonyl derivatives.  相似文献   

16.
In the present work, a high performance liquid chromatographic method with UV detection for the separation of six organic acids including, tartaric, malic, acetic, lactic, citric and succinic is described.The separation was performed on a novel stationary phase TEKNOKROMA, Tr-010065 Mediterranea sea18 (15 cm × 0.4 cm, i.d. 3 μm) and using water with a 0.1% (v/v) of formic acid as mobile phase. The advantages of this packing over a conventional octadecylsilane (ODS2) column are reported.The method was validated with respect to linearity, limits of detection and repeatabilities within day and between days and satisfactory results were obtained.The proposed method was applied for the determination of these compounds in commercially available white wines. The samples were injected directly without previous treatment. LC-MS was used as a confirmatory technique.  相似文献   

17.
The reactions of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with glyphosate (GLY) and with its main metabolite, aminomethylphosphonic acid (AMPA), have been studied. The resolution of binary mixtures of glyphosate and aminomethylphosphonic acid has been accomplished by partial least squares (PLS) multivariate calibration. The method of determination is based on the fluorescence emission of the derivatives formed in presence of NBD-Cl at 90 °C, in methanol and in basic medium. The dynamic ranges of the methods were comprised between 10 and 150 μg l−1 for GLY and between 10 and 200 μg l−1 for AMPA, being the detection limits 2 and 5.4 μg l−1 for GLY and AMPA, respectively. The total luminiscence information of the derivatives has been used to optimize the spectral data set to perform the calibration, by analysis of the three-dimensional excitation-emission matrices. A comparison between the predictive ability of the multivariate calibration method, partial least squares type 1 (PLS-1), on two spectral data sets, emission and synchronous spectra, has been performed. The PLS-1 method, applied to the emission spectra, has been selected as optimum. The proposed method has been applied to the simultaneous determination of GLY and AMPA in river water. For concentrations ranging from 100 to 600 μg l−1 of each compound in the samples, analytical recoveries range from 83 to 94% for GLY and from 104 to 120% for AMPA.  相似文献   

18.
A dynamic supported liquid membrane tip extraction (SLMTE) procedure for the effective extraction and preconcentration of glyphosate (GLYP) and its metabolite aminomethylphosphonic acid (AMPA) in water has been investigated. The SLMTE procedure was performed in a semi-automated dynamic mode and demonstrated a greater performance against a static extraction. Several important extraction parameters such as donor phase pH, cationic carrier concentration, type of membrane solvent, type of acceptor stripping phase, agitation and extraction time were comprehensively optimized. A solution of Aliquat-336, a cationic carrier, in dihexyl ether was selected as the supported liquid incorporated into the membrane phase. Quantification of GLYP and AMPA was carried out using capillary electrophoresis with contactless conductivity detection. An electrolyte solution consisting of 12 mM histidine (His), 8 mM 2-(N-morpholino)ethanesulfonic acid (MES), 75 μM cetyltrimethylammonium bromide (CTAB), 3% methanol, pH 6.3, was used as running buffer. Under the optimum extraction conditions, the method showed good linearity in the range of 0.01–200 μg/L (GLYP) and 0.1–400 μg/L (AMPA), acceptable reproducibility (RSD 5–7%, n = 5), low limits of detection of 0.005 μg/L for GLYP and 0.06 μg/L for AMPA, and satisfactory relative recoveries (90–94%). Due to the low cost, the SLMTE device was disposed after each run which additionally eliminated the possibility of carry-over between runs. The validated method was tested for the analysis of both analytes in spiked tap water and river water with good success.  相似文献   

19.
The feasibility of a microcolumn electrophoresis technique was investigated with a 100 mm length, 2 mm I.D. fused-silica microcolumn packed with uniform quartz microncrystals prepared by hydrothermal synthesis. To evaluate the separation technique, tryptophan, phenylalanine and tyrosine were primarily separated by the microcolumn electrophoresis and detected at 216 nm without derivatization by an ordinary spectrophotometer. The separation conditions of the amino acids were optimized. With 1.5 mmol/L disodium phosphate buffer solution (pH 11.5) containing 25% (v/v) methanol and 10% (v/v) acetonitrile, the three amino acids were separated and the separation efficiency of tryptophan was 4.5 × 104 plates/m. The limits of detection were 0.035, 0.22 and 0.20 μmol/L, respectively. The sample capacity of the electrophoretic microcolumn achieved 35 μL. The proposed method was used to determine these amino acids in compound amino acid injection samples without derivatization. For the simplicity and portability of the microcolumn electrophoresis, it is studied as one of the high-performance separation techniques for an in situ and real-time electrokinetic flow analysis system. For its high detection sensitivity and large sample capacity, it can be developed for preparative electrophoresis.  相似文献   

20.
Li G  Ji Z  Wu K 《Analytica chimica acta》2006,565(2):178-182
In the study, we developed a simple, rapid and sensitive method for the determination of tiopronin (TP) in human plasma, which was based on derivatization with p-bromophenacyl bromide (p-BPB) followed by liquid-liquid extraction and reverse-phase HPLC-UV detection. For the first time, the p-BPB was introduced into the derivatization of TP. The thiol group of TP was trapped with p-BPB to form a TP-p-BPB adduct, which can be very suitable for UV detection. From acidified plasma samples, the derivatized TP was extracted with 5 mL dichloromethane. Effective chromatographic separation was achieved using a C18 column (DIAMONSIL 150 mm × 4 mm i.d., 5 μm) based on an acetonitrile-water-trifluoroacetic acid (40:59.88:0.12, v/v/v) elution at a flow-rate of 1 mL/min. The IS and the derivatized TP were detected at 263 nm. No endogenous substances were found to interfere. The limit of quantification for derivatized TP (TP-p-BPB) in plasma was 40 ng/mL. The calibration curve for the derivatized TP showed linearity in the range 0.04-4 μg/mL with a regression coefficient corresponding to 0.9991 and the coefficient of the variation of the points of the calibration curve being lower than 10%. Extraction recoveries of the derivatized TP in plasma were greater than 72%. The method was suitably validated and successfully applied to determination of TP in human plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号