首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Phenolic compounds are a sort of common pollutants in water. Phenol index becomes an expedite indicator for the evaluation of the contamination level of water samples, in spite of the knowledge of the individual phenol and its derivatives are also important.In this work, an environmental friendly method for the determination of phenols, using a segmented flow system based on the conventional method's reactions without the liquid-liquid extraction step, was validated.Three linear dynamic ranges using C6H5OH: 1-10 μg l−1, 10-200 μg l−1 and 0.2-2.5 mg l−1, with a coefficient of variation lower than 2%, were obtained. Several method's performance parameters were determined: limits of detection, limits of quantification, precision through duplicate analysis and trueness using the reference materials purchased from LGC Promochem, RTC no. QCI-043-2 Lot:P1. Measurement uncertainty was evaluated using an interlaboratory approach based on proficiency testing data. Relative combined uncertainty for phenols in water samples, , of 0.054 were obtained, in according to those imposed by the Portuguese Legislation: target for 1 μg l−1 of phenol (surface waters) and target for 500 μg l−1 of phenol (wastewaters).A high efficiency reduction and elimination of reagents and wastes, reduction of analysis time and exposition of the analyst were also obtained.  相似文献   

2.
We describe a multifunctional flow analysis instrument that is portable ( cm, 2.3 kg) for facile field deployment. Using a 50 cm long Teflon® AF tubing as final reaction and optical measurement conduit, we combine a liquid-core waveguide (LCW) based fluorescence detector that is transversely illuminated by an addressable light emitting diode array, a chemiluminescence (CL) detector and an absorbance detector with a solid-state broadband (400-700 nm) source. Several illustrative experiments have been carried out to test the performance of the instrument in different detection modes. A S/N=3 limit of detection (LOD) of 0.25 μg l−1 for chromium(VI) was established using the diphenylcarbazide chemistry, and an LOD of 5 μg l−1 was similarly established for Al(III), using Pyrocatechol Violet (PCV) as the chelating chromogenic dye, in both cases using long path absorption detection. The LOD for aqueous hydrogen peroxide was 16 nM using a fluorescence method based on the formation of thiochrome from thiamine and 4 nM by a luminol chemiluminescence method. With a Nafion membrane diffusion scrubber (DS), the LOD was 8.0 pptv for gaseous hydrogen peroxide by the fluorescence method.  相似文献   

3.
A novel on-line coupled capillary electrophoresis (CE) cold vapor generation (CVG) with electrothermal quartz tube furnace atomic absorption spectrometry (EQTF-AAS) system for mercury speciation has been developed. The mercury species (inorganic mercury and methylmercury) were completely separated by CE in a 80 cm length × 100 μm i.d. fused-silica capillary at 20 kV and using a buffer of 100 mM boric acid and 10% (v/v) methanol (pH 8.30). The effects of the inner diameter of quartz tube, the acidity of HCl, the NaBH4 concentration and N2 flow rate on Hg signal intensity were investigated. Speciation of mercury was highlighted using CE-CVG-EQTF-AAS. The detection limits of methylmercury and mercury were 0.035 and 0.027 μg mL−1, respectively. The precisions (RSDs) of peak height for six replicate injections of a mixture of 10 μg mL−1 (as Hg) were better than 4%. The interface was used for speciation analysis of mercury in dry goldfish muscle.  相似文献   

4.
Lu C  Lin JM  Huie CW 《Talanta》2004,63(2):333-337
Peroxynitrous acid (ONOOH) was produced by the on-line reaction of acidified hydrogen peroxide with nitrite in a flow system, and peroxynitrite (ONOO) was generated from ONOOH in NaOH solution. A weak chemiluminescent (CL) emission was observed due to the production of singlet oxygen ( ) during the decomposition of ONOO. Bilirubin and its conjugate were found to enhance the CL emission of in a suitable micellar medium. For the first time, the feasibility of employing the present CL system for the sensitive and selective determination of total bilirubin contents in human serum was demonstrated and the results were compared with certified values. The present method showed a great improvement on overcoming bis(2,4,6-trichlorophenyl)oxalate CL highly insolubility in aqueous solution and exhibiting higher tolerance towards interferences than redox reaction of bilirubin with various oxidizing agents such as sodium hypochlorite and iodine. The recoveries of bilirubin were found to fall in the range between 95 and 108%. The detection limits (S/N=3) for bilirubin and its conjugate were determined to be 10 and 8 ng ml−1, respectively. The relative standard deviations (R.S.D.) for the consecutive CL detection of a series of bilirubin (30 μg l−1) and bilirubin ditaurite (25 μg l−1) were 3.2 and 2.9% (n=11), respectively.  相似文献   

5.
Capillary electrophoresis dynamic reaction cell™ inductively coupled plasma mass spectrometry (CE-DRC-ICP-MS) for the determination of sulfur-containing amino acids is described. The sulfur-containing amino acids studied include l-cysteine, l-cystine, dl-homocystine and l-methionine. The species studied were well separated using a 70 cm length×75 μm i.d. fused silica capillary while the applied voltage was set at +22 kV and a 10 mmol l−1 disodium tetraborate buffer (pH 9.8) containing 0.1 mmol l−1 EDTA and 0.5 mmol l−1 Triton X-100 was used as the electrophoretic buffer. The sulfur-selective electropherogram was determined at m/z 48 as by using its reaction with O2 in the reaction cell. The method avoided the effect of polyatomic isobaric interferences at m/z 32 caused by and on by detecting as the oxide ion at m/z 48, which is less interfered. The detection limit of various species studied was in the range of 0.047-0.058 μg S ml−1, which corresponded to the absolute detection limit of 1.3-1.6 pg S based on the injection volume of 27 nl. We determined the concentrations of selected sulfur-containing amino acids in urine and nutritive complement samples. The recovery was in the range of 92-128% for various species.  相似文献   

6.
7.
Inductively coupled plasma mass spectrometry (ICP-MS) with a time-of-flight (TOF) analyser was used for the determination of chromium, cadmium and lead in six food-packaging materials (paper and paper board). The samples (0.20-0.25 g) were digested in concentrated nitric acid in a high pressure microwave oven at 180 °C within 15 min. Two different plasma conditions were applied: cool plasma conditions (0.76 kW; 0.85, 0.89 and 15.5 l min−1 nebuliser, auxiliary and plasma gas flow rate, respectively) for the determination of chromium and normal plasma conditions (1.21 kW; 0.66, 0.68 and 13.6 l min−1 nebuliser, auxiliary and plasma gas flow rate, respectively) for the determination of cadmium and lead. External calibration was used in combination with rhodium (40 ng g−1) as an internal standard. The detection limits (DL = 3S.D./sensitivity) under the conditions used corresponded to 0.01 ng g−1 (), 0.06 ng g−1 (), 0.07 ng g−1 (), 0.03 ng g−1 () and 0.02 ng g−1 ( and ). The precision (R.S.D.) for six replicate determinations (10 s integration time) of 1 and 10 ng g−1 of each analyte varied from 0.72% () to 4.43% (). The contents of chromium, cadmium and lead in the examined materials were evaluated using the signals of , and . They were in the range: 0.25-0.50 μg g−1 for Cr, not detected (nd) to 0.12 μg g−1 for Cd and 0.28-0.35 μg g−1 for Pb in paper and 0.50-0.64 μg g−1 for Cr, nd to 0.09 μg g−1 for Cd and 0.67-0.99 μg g−1 for Pb in paper board.  相似文献   

8.
A method for on-line preconcentration of palladium at ultra-trace level on alumina microcolumns and determination by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. A sampling time of 10 min (30 ml) and an eluent (KCN) volume of 300 μl provides a limit of detection of 1 ng l−1. The precision was 4% at the 25 ng l−1 level. The proposed system allows the on-line removal of the primary interferents (Cu and Y) providing the credible accuracy of the results. The proposed method is suitable for palladium determination in urban water samples. Platinum concentration in the analysed urban water samples was also determined.  相似文献   

9.
Three sample preparation methods (dilution, microwave digestion and ethanol addition) were evaluated for the determination of Se in human plasma using magnetic sector inductively coupled plasma mass spectrometry (ICP-MS). A number of instrumental parameters were also considered, namely the choice of internal standard (Sc, Rh, In) and pre-defined spectral resolution (mm ∼300 (low resolution, LR) and ∼7500 (high resolution, HR)). The isotopes and were selected for analysis avoiding the major and unresolvable Ar dimer interferences associated with other Se isotopes.Ethanol addition was found to be the most suitable and reliable sample preparation method. The optimum ethanol concentration for a 1+9 dilution of the plasma sample was 0.5% (v/v). Indium or Sc were selected over Rh as internal standards as Seronorm™ Level 1 target values were achieved at lower concentrations of ethanol modifier. Representative ICP-MS detection limits for this method using (HR) and (HR), were 0.1 and 0.2 μg l−1.Accurate analysis of Se in Seronorm™ Level 1 (MI0181) was found using either or and HR (86±5 and 83±5 μg l−1 respectively, n=5, In internal standard, target value=83±6 μg l−1). Although offering improved precision (e.g. LR: 0-3% versus HR: 1-6%), accurate results were only obtained with LR for the Seronorm™ Level 1 sample when using (86±1 μg l−1). The major interference precluded accurate Se analysis using and LR for all samples considered. Reliable Se concentrations were only found for a “real” pooled sample when using (HR), in part a result of non-negligible and unresolved interference when using LR. Consistently elevated Se concentrations were found under all conditions when Seronorm™ Level 2 (NO0371) was analysed. These results were confirmed by independent GF-AAS analysis.Magnetic sector ICP-MS with (HR), in combination with the ethanol addition sample preparation method, was used for the analysis of Se in human plasma samples as part of a small pilot study. Average measured selenium concentrations were 102±18 μg l−1 (n=18).  相似文献   

10.
A determining technique of sulfonamides (SAs) (sulfamonomethoxine (SMM), sulfadimethoxine (SDM), and sulfaquinoxaline (SQ)) in eggs, without use of organic solvents, is developed utilizing a high-performance liquid chromatography (HPLC) interfaced with a photo-diode array detector. The sample preparation was performed by homogenizing with perchloric acid solution using a handy ultrasonic-homogenizer followed by a centrifugal ultra-filtration unit. An analytical column and an isocratic mobile phase for HPLC are a reversed-phase C4 column ( mm i.d.) and 0.18 mol l−1 citric acid solution, respectively. The proposed technique was shown to be linear (r>0.998) over the concentration range 0.1-2.0 μg g−1. Average recoveries of three SAs (spiked 0.05, 0.1, 0.15, and 0.2 μg g−1) ranged from 80.3 to 88.4%, with relative standard deviations (R.S.D.s) between 3.4 and 5.8%. The practical detection limits and total time required for the analysis of one sample were < 0.05 μg g−1 and <30 min, respectively. In all the processes, no organic solvents were used at all.  相似文献   

11.
12.
《Analytica chimica acta》2004,512(2):287-295
The potential of non-aqueous capillary electrophoresis (NACE) was investigated for the simultaneous separation of paroxetine, tamoxifen, and their main metabolites. Baseline separation of the studied solutes was obtained on a  μm capillary using a non-aqueous buffer composed of 18 mM ammonium acetate and 1.1% acetic acid in 80:20 (v/v) methanol-acetonitrile, with a temperature and voltage of 22 °C and 15 kV, respectively. Clomipramine was used as internal standard. Aspects such as stability of the solutions, linearity, accuracy, precision and ruggedness were examined in order to validate the proposed method. Detection limits obtained for all the studied compounds ranged between 3.0 and 7.1 μg l−1. The developed method is sensitive and robust and was used to determine paroxetine, tamoxifen, and their metabolites at clinically relevant levels in human urine. Before NACE determination, the samples were purified and enriched by means of an extraction-pre-concentration step with a pre-conditioned C18 cartridge. Determination of these analytes in the urine of four females urines was demonstrated.  相似文献   

13.
A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ng l−1 levels of analytes retained on the silica C18 solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C18 amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3 min by the use of sonication stirring instead of magnetic stirring. The use of 1 mol dm−3 hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5 mol dm−3 hydrochloric acid and 10−4% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25 ng l−1, respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.  相似文献   

14.
Erdem A  Eroğlu AE 《Talanta》2005,68(1):86-92
A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l−1) and the certified value (13.79 ± 0.42 μg l−1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l−1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l−1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l−1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.  相似文献   

15.
A high-pressure microwave digestion was applied for microwave-assisted extraction (MAE) of mercury species from sediments and zoobenthos samples. A mixture containing 3 mol L−1 HCl, 50% aqueous methanol and 0.2 mol L−1 citric acid (for masking co-extracted Fe3+) was selected as the most suitable extraction agent. The efficiency of proposed extraction method was better than 95% with R.S.D. below 6%. A preconcentration method utilizing a “homemade” C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the mercury species determination using on-column complex formation of mercury-2-mercaptophenol complexes. Methanol was chosen for counter-current elution of the retained mercury complexes achieving a preconcentration factor as much as 1000. The preconcentration method was applied for the speciation analysis of mercury in river water samples. The high-performance liquid chromatography-cold vapour atomic fluorescence spectrometric (HPLC/CV-AFS) method was used for the speciation analysis of mercury. The complete separation of four mercury species was achieved by an isocratic elution of aqueous methanol (65%/35%) on a Zorbax SB-C18 column (4.6 mm × 150 mm, 5 μm) using the same complexation reagent (2-mercaptophenol). The limits of detection were 4.3 μg L−1 for methylmercury (MeHg+), 1.4 μg L−1 for ethylmercury (EtHg+), 0.8 μg L−1 for inorganic mercury (Hg2+), 0.8 μg L−1 for phenylmercury (PhHg+).  相似文献   

16.
C. March  Y. Jiménez  A. Montoya 《Talanta》2009,78(3):827-1971
A quartz crystal microbalance (QCM) immunosensor was developed for the determination of the insecticide carbaryl and 3,5,6-trichloro-2-pyridinol (TCP), the main metabolite of the insecticide chlorpyrifos and of the herbicide triclopyr. The detection was based on a competitive conjugate-immobilized immunoassay format using monoclonal antibodies (MAbs). Hapten conjugates were covalently immobilized, via thioctic acid self-assembled monolayer (SAM), onto the gold electrode sensitive surface of the quartz crystal. This covalent immobilization allowed the reusability of the modified electrode surface for at least one hundred and fifty assays without significant loss of sensitivity. The piezoimmunosensor showed detection limits (analyte concentrations producing 10% inhibition of the maximum signal) of 11 and 7 μg l−1 for carbaryl and TCP, respectively. The sensitivity attained (I50 value) was around 30 μg l−1 for both compounds. Linear working ranges were 15-53 μg l−1 for carbaryl and 13-83 μg l−1 for TCP. Each complete assay cycle took 20 min. The good sensitivity, specificity, and reusability achieved, together with the short response time, allowed the application of this immunosensor to the determination of carbaryl and TCP in fruits and vegetables at European regulatory levels, with high precision and accuracy.  相似文献   

17.
Several derivatization procedures with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) were compared for a rapid analysis of primary aliphatic short-chain monoamines in water samples by HPLC using a LiChorospher analytical separation column (100RP18 mm i.d., 5 μm). Both the solution and the solid-support assisted off-line derivatization on C18 SPE cartridges were inadequate options because of beginning degradation processes of the instable isoindol derivatives during their transfer to the analytical column. This problem was precluded with the on-column or solid-support assisted on-line derivatization. In the last mentioned procedure, the derivatization took place in a Hypersil C18 precolumn ( mm i.d., 30 μm) connected with an additional preconcentration step resulting in better detection limits (0.002-0.040 μg ml−1 requiring only 150 μl of water sample) than in the on-column procedure (0.08-0.16 μg ml−1). The improved sample handling, the better control of parameters affecting reaction rates, the fully automation of this method with only 10 min analysis time for each sample are further advantageous. The potential of the solid-support assisted on-line derivatization was outlined and applied to water samples from several sources. Recovery values near 100% were obtained.  相似文献   

18.
Jairo L. Rodrigues 《Talanta》2010,80(3):1158-162
Despite the necessity to differentiate chemical species of mercury in clinical specimens, there are a limited number of methods for this purpose. Then, this paper describes a simple method for the determination of methylmercury and inorganic mercury in blood by using liquid chromatography with inductively coupled mass spectrometry (LC-ICP-MS) and a fast sample preparation procedure. Prior to analysis, blood (250 μL) is accurately weighed into 15-mL conical tubes. Then, an extractant solution containing mercaptoethanol, l-cysteine and HCl was added to the samples following sonication for 15 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of mercury species was accomplished in less than 5 min on a C18 reverse-phase column with a mobile phase containing 0.05% (v/v) mercaptoethanol, 0.4% (m/v) l-cysteine, 0.06 mol L−1 ammonium acetate and 5% (v/v) methanol. The method detection limits were found to be 0.25 μg L−1 and 0.1 μg L−1 for inorganic mercury and methylmercury, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). The proposed method was also applied to the speciation of mercury in blood samples collected from fish-eating communities and from rats exposed to thimerosal. With the proposed method there is a considerable reduction of the time of sample preparation prior to speciation of Hg by LC-ICP-MS. Finally, after the application of the proposed method, we demonstrated an interesting in vivo ethylmercury conversion to inorganic mercury.  相似文献   

19.
A simple and robust time-based on-line sequential injection system for trace mercury determination via cold vapour atomic absorption spectrometry (CVAAS), employing a new integrated gas-liquid separator (GLS), which in parallel operates as reactor, was developed. Sample and reductant are sequentially loaded into the GLS while an argon flow delivers the released mercury vapour through the atomic absorption cell. The proposed method is characterized by the ability of successfully managing variable sample volume up to 30 ml in order to achieve high sensitivity. For 20 ml sample volume, the sampling frequency is 25 h−1. The calibration curve is linear over the concentration range 0.05-5.0 μg l−1 of Hg(II), the detection limit is cL = 0.02 μg l−1, and the relative standard deviation is sr = 2.6% at 1.0 μg l−1 Hg(II) level. The performance of the proposed method was evaluated by analyzing certified reference material and applied to the analysis of natural waters and biological samples.  相似文献   

20.
A procedure involving bead-injection concept and sequential determination of copper and mercury ions in river-water samples is proposed. The method is based on the solid-phase extraction of both metal ions on the same beads surface (Chelex 100 resin) and in their subsequent reaction with the colorimetric reagents (APDC and Dithizone for copper and mercury ions, respectively). For this task, a resin mini-column is established in the optical path by the selection, introduction and trapping of a defined volume of the Chelex-100 resin beads suspension in the flow system. The passage of the sample solution through the resin mini-column promotes the sorption of Cu(II) ions and, making the APDC colorimetric reagent flows through the beads, the formation of the coloured complex on the solid phase surface occurs. The absorbance of the formed APDC-Cu complex is then monitored at 436 nm and the spent beads are discarded. Packing another resin mini-column in the flow cell and repeating the concentration step it is possible to carried out the mercury determination by using Dithizone as reagent. The absorbance of the Dithizone-Hg complex is monitored at 500 nm. After each measurement, the spent beads are wasted and a new portion of fresh one is trapped in the system, letting it ready for the next measurement. The bead injection system is versatile and can be used to concentrate different sample volumes, which permits the determination of a wide range of copper and mercury ions concentrations. When the sample-selected volumes are 100 and 1000 μl the analytical ranges were 5.0 up to 500.0 μg l−1 and 2.5 up to 30.0 μg l−1 for Cu(II) and Hg(II) ions, respectively. Under these conditions, the detection limit was estimated as 0.63 and 0.25 μg l−1 for copper and mercury ions determination. The system consumes 2 mg of Chelex 100 resin beads, 0.20 mg of APDC or 1.25 mg of Dithizone per determination and the traditional organic solvent extraction methodology, normally used in connection with APDC and Dithizone reagents, is not used here which permits to classify the present method as green.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号