首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development and evaluation of a flow injection inductively coupled plasma mass spectrometric (FI-ICP-MS) method for the determination of copper and iodine in milk and milk powder has been described. The sample preparation is based simply on the dilution of the sample by an alkaline solution containing 0.05 mol/l potassium hydroxide and 0.07 mol/l tetramethylammonium hydroxide. Possible matrix interferences on the determination of copper were alleviated by the use of standard addition calibration. Detection limits (3s) were 0.94 microg l(-1) and 0.45 microg l(-1) for copper and iodine, respectively. Four different certified milk powder reference materials were analysed and the concentrations found were in a good agreement with the certified values indicating that the method is unbiased. Due to the simplicity of the method a high sample throughput is possible, approximately 90 samples can be analysed in one day. More than 100 samples of Danish raw milk were analysed and median values of 0.050 mg kg(-1) of Cu and 0.084 mg kg(-1) of I were found.  相似文献   

2.
A high-performance liquid chromatographic method was optimized and validated for the determination of desacetyl nitazoxanide (tizoxanide), the main active metabolite of nitazoxanide in human plasma, urine and breast milk. The proposed method used a CN column with mobile phase consisting of acetonitrile-12mM ammonium acetate-diethylamine in the ratio of 30:70:0.1 (v/v/v) and buffered at pH 4.0 with acetic acid, with a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 260 nm using nifuroxazide as internal standard. A simplified direct injection of urine samples without extraction in addition to the urinary excretion pattern were calculated using the proposed method. Also, the effectiveness of protein precipitation and a clean-up procedure were investigated for biological plasma and human breast milk samples. The validation study of the proposed method was successfully carried out in an assay range between 0.2 and 20 μg/mL.  相似文献   

3.
A novel method based on column-switching high-performance liquid chromatography-electrospray mass spectrometry (LC-MS) coupled with an on-line extraction column containing conjugated avidin has been developed for direct injection analysis of di(2-ethylhexyl) phthalate (DEHP) and its metabolite, mono(2-ethylhexyl) phthalate (MEHP), in blood samples. The sample preparation for on-line extraction involved the mixing of blood samples with internal standards, DEHP-d(4) and MEHP-d(4), in LC glass vials. A linear response was found for column-switching LC-MS when tests were conducted within the validated range of 25 to 1000 ng mL(-1) for DEHP and 5 to 1000 ng mL(-1) for MEHP, with correlation coefficients (r) greater than 0.999. In addition, the recoveries of DEHP and MEHP from human plasma were calculated by using this method with on-line extraction, yielding recoveries of up to 91.2% (RSD<5%). We measured the background levels of DEHP and MEHP in six human plasma samples from healthy volunteers and three fetal bovine serum samples for cell-line culture. DEHP and MEHP were not detected in all human plasma samples (N.D. is <25 ng mL(-1) for DEHP, and N.D. is <5.0 ng mL(-1) for MEHP). In contrast, high DEHP contamination of commercially available fetal bovine serum samples was found by this method.  相似文献   

4.
A newly developed large-volume injection (LVI) technique that employs a unique stomach-shaped inlet liner (SSIL) inside of a programmable temperature vaporizer was used for the determination of trace amounts of dioxins in human milk and plasma. The initial temperature and the initial dwelling time of the inlet and the kind of solvent used were found to be critical in determining the analytical sensitivity of dioxins due to the loss of these relatively volatile compounds during solvent vaporization. Human milk and plasma were purified and fractionated by pre-packed multi-layered silica-gel chromatography and activated carbon silica-gel column chromatography. A 20-microL aliquot of the fraction collected from the chromatography with toluene was directly applied to the LVI system in high-resolution gas chromatography/high-resolution mass spectrometry. Excellent correlation (r > 0.97) between the values obtained by the LVI method using the SSIL device and those by the conventional regular-volume splitless injection method was obtained for PCDDs, PCDFs and non-ortho PCBs in human milk and plasma samples.  相似文献   

5.
A column-switching high-performance liquid chromatographic method with UV detection for the determination of cocaine (COC) and benzoylecgonine (BZE) in human blood plasma samples is described. The method uses an alkyl-diol-silica ADS-C18 extraction precolumn. A 50- micro L plasma sample was introduced to the ADS precolumn in order to separate the analytes from proteins and endogenous compounds. The fraction containing COC and BZE was back-flushed and transferred to an Alltech mixed-mode C(18)/cation-exchange analytical column for final separation. The validation of the method revealed quantitative recoveries from 95.0 to 99.0% for COC at three different concentrations (0.5, 1.0 and 2.0 micro g mL(-1)), and from 96.0 to 99.0% for BZE at the same concentration levels with coefficients of variation <4.00% (n=5). The detection limit (signal to noise ratio (S/N)>3) was 0.03 micro g mL(-1) for all the compounds with an injection volume of 50 micro L. However, it was possible to enhance the sensitivity further by injecting larger plasma volumes, up to 200 micro L, at the same optimal conditions. The overlap of sample preparation, analysis and reconditioning of the extraction column, increase the overall sample throughput to 5 samples h(-1). The developed method has been applied to human blood plasma samples from subjects suspected of cocaine abuse.  相似文献   

6.
Using triacontyl bonded silica (C30) as on-line solid-phase extraction (SPE) material and a specially designed on-line analytical system which allowed large sample volume injection, a high speed and robust on-line SPE-HPLC–MS method was established for the analysis of five estrogens and bisphenol A (BPA) in milk samples. The milk sample is pretreated with acetonitrile for protein precipitation and then treated with primary secondary amine for the removal of polar impurities in the matrix. Then the pretreated sample can be automatically loaded by a LC pump. For effective extraction, an offshoot with NH4Ac solution of high-flow rate was employed to dilute the loaded sample by a mixing tee before sample was loaded onto the C30 extraction column. In this way, large volume injection (1 mL in this experiment) could be achieved. Some important parameters such as sample loading flow rate, sample dilution ratio and injection volume were optimized. Under the optimized conditions, the recoveries for all analytes range from 71.4 to 97.1% and reproducibility represented as RSDs are less than 15.0% (n = 5) with milk samples spiked at 0.6 and 15 ng/mL of each analyte. To the authors’ knowledge, it constitutes the first work describing a C30 on-line SPE-LC–MS analytical method for the screen and monitoring of these estrogens and BPA in milk.  相似文献   

7.
A sensitive high‐performance CZE combining on‐column field‐amplified sample injection (FASI) has been developed for simultaneous determination of aripiprazole and its active metabolite, dehydroaripiprazole, in human plasma. A sample pretreatment by means of liquid–liquid extraction (LLE) (diethyl ether) with subsequent quantitation by FASI‐CZE was used. The separation of aripiprazole and dehydroaripiprazole was performed using a BGE containing 150 mM phosphate buffer (pH 3.5) with 40% methanol and 0.02% PVA as a dynamic coating to reduce interaction of analytes with the capillary wall. Before sample loading, a methanol plug (0.3 psi, 6 s) was injected to permit FASI for stacking. The samples were injected electrokinetically (10 kV, 30 s) to introduce sample cations and the applied voltage was 20 kV with on‐column detection at 214 nm. Several parameters affecting the separation and sensitivity of the drug and its active metabolite were studied, including reconstitution solvent, organic modifier, pH and concentration of phosphate buffer. The linear ranges of the method for test drug and its active metabolite, in plasma using amlodipine as an internal standard, were over the range 5.0–100.0 ng/mL. One female volunteer (25 years old) was orally administered a single dose of 10 mg aripiprazole (Abilify®, Otsuka) and blood samples were drawn over a 60 h period for pharmacokinetic study. The method was also applied to monitor the concentration of aripiprazole and dehydroaripiprazole in plasma collected after oral administration of 20 or 30 mg aripiprazole (Abilify®, Otsuka) daily at steady state in one schizophrenic patient.  相似文献   

8.
A fast and reliable procedure for the determination of total and free calcium in milk is described. The method is based on the flow injection (Fl) technique. Total calcium is determined by atomic absorption spectrometry (AAS) (422.7 nm) and free calcium by spectrophotometry (580 nm). Interference in the determination of free calcium is eliminated by using a dialyser, which also separates the total and free calcium. Interference from phosphates in milk in the determination of total calcium by AAS is overcome by using a dinitrogen oxide-acetylene flame with the necessary suppression with K+. With 30-microliters samples the Fl system covers a standard working range of 100-1500 mg dm-3 of Ca2+. The system is suitable for the simultaneous determination of total calcium (relative standard deviation less than 1.30% for 1300-1500 mg dm-3 of total calcium) and free calcium (relative standard deviation less than 0.85% for 120-170 mg dm-3 of free calcium) in milk at a sampling frequency of about 60 samples h-1. The results obtained agree reasonably well with results from the AAS method.  相似文献   

9.
A capillary zone electrophoretic assay has been developed and validated for analysis of magnesium, calcium, sodium, and potassium in blood plasma samples. Optimum results were obtained with 20 mmol L−1 imidazole (pH 2.8) and 0.5 mmol L−1 oxalic acid containing 5% methanol, capillary temperature 25°C, applied voltage 30 kV, hydrodynamic injection time 3 s, and a poly(vinyl alcohol)-coated capillary (i.d. 50 μm, total length 64.5 cm and effective length 56 cm). Indirect detection was performed at 214 nm. Cadmium was used as internal standard. The migration times of magnesium, calcium, sodium, and potassium were 4.25, 3.79, 3.96, and 2.79 min, respectively. The method was applied to the determination of magnesium, calcium, sodium, and potassium in blood plasma samples. The results were compared with those from atomic absorption spectrophotometry and no statistically significant difference was found (P>0.05). This study was supported by the Turkish Republic, Prime Ministry State Planning Organization (Project Number: 98K121730)  相似文献   

10.
TY Ma  TW Vickroy  JH Shien  CC Chou 《Electrophoresis》2012,33(11):1679-1682
A NACE method with laser-induced fluorescence detection was modified for sensitive detection of 4 tetracyclines (TCs) in biological samples and feeds. The changes in injection mode, injection times, id of capillary, excitation wavelength, and the use of surfactant and sample stacking technique all contributed to improved LODs of TCs to sub-ng/mL level. With the optimized conditions, the instrumental LODs could reach 1.33 ng/mL for chlorotetracycline (CTC) and 13.3 ng/mL for TC, oxytetracycline (OTC), and doxycycline (DC), an improvement of 10-100-fold over past studies. A simple SPE procedure was further developed for the extraction and concentration of TCs in plasma, urine, feed, and milk. Taken together, the instrumental LOD and feasible SPE concentration factors the overall LODs for CTC could reach 65 pg/mL in feed and milk and 260 pg/mL in plasma and urine. Detection limits for TC, OTC, and DC at sub-ng/mL level were also achieved. The modified CE-LIF method was found to be less complicated and more sensitive than the best current methods using UV or LIF detection, and has been applied successfully to assess oral absorption of DC in swine and chickens and to confirm suspected TC-positive bovine serum samples.  相似文献   

11.
Inositol is a six‐carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo‐inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo‐inositol (MI), D ‐chiro‐inositol (DCI) and 1,5‐anhydro‐ D ‐sorbitol (ADS) in very small‐volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple‐column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above‐mentioned performance measures were within acceptable limits described in the Food and Drug Administration's Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma, milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
An analytical system based on a sensor array with ion-selective field effect transistors (ISFETs) monolithically integrated in one chip covered with photocured polymer membranes containing copolymerised plasticizer and a sequential injection analysis (SIA) is shown to offer an automation of the analysis of blood serum components. For sequential injection system a custom made dual channel flow cell for the sensor array was developed. Optimisation of ion-sensitive membrane characteristics and calibration solution compositions were carried out. The system was used to analyze sodium, potassium, chloride ion contents in blood serum samples. The precision of the ion determination in samples was typical for potentiometic method with standard deviation of about 3-5%.  相似文献   

13.
Wei J  Guo Z  Shen A  Zhang F  Liang X 《色谱》2011,29(7):687-690
应用QuEChERS前处理技术,并结合弱阳离子交换色谱,建立了牛奶和奶粉中三聚氰胺的快速检测方法。样品使用医用酒精(乙醇含量75%)和一种新型脂肪吸附(LAS)材料超声振荡处理,在沉淀(吸附)蛋白质和脂肪的同时提取三聚氰胺,然后经8000 r/min离心,上清液过膜直接分析。色谱分析在弱阳离子交换色谱柱(WCX)上进行,采用2 mmol/L pH为3.8的磷酸二氢钾水溶液为流动相,在5 min内实现分离分析。结果表明,该方法在0.02~20 mg/L内线性相关系数大于0.9999。在1~50 mg/kg添加浓度范围内,牛奶的平均回收率为98.9%~105.2%,相对标准偏差(RSD)为0.9%~3.4%;奶粉的平均回收率为86.4%~102.9%, RSD为1.5%~6.7%。本方法的检出限为0.05 mg/kg(牛奶)和0.1 mg/kg(奶粉)。整个分析检测过程没有使用有毒有害有机溶剂,是一种绿色的分析方法。  相似文献   

14.
A simple, selective and very sensitive assay is described for the quantification of physostigmine in blood, plasma and urine. The most appropriate solid phase column was selected after a systematic investigation of nine types of phase. The conditions for solid phase extraction were optimized using [3H]physostigmine so that the overall recoveries were greater than 90%. Physostigmine was retained on alkaline treated cyanopropyl columns and eluted into the minimum volume of methanol, obviating the need for an evaporation step. Extracted samples were quantified by HPLC with a three electrode coulometric detection system. The limit of detection was 50 pg/mL for a 0.5 mL plasma sample. The precision (CV) for 0.5 mL plasma samples containing 50 pg was 8.1%. Application of the method to plasma, blood and urine samples is presented.  相似文献   

15.
A high performance liquid chromatographic method is described for monitoring forphenicinol, a possible therapeutic drug for cancer and muscular dystrophy, in human plasma and erythrocytes. Forphenicinol in the deproteinized samples was separated from interfering biogenic substances on an aminopropyl-bonded silica (Unicil NH2) column within 10 minutes with isocratic elution, and determined with fluorescence detection. The detection limits for forphenicinol in plasma and erythrocytes are 65 pmol (12.8 ng)/ml and 160 pmol (31.5 ng)/ml, respectively, corresponding to 2 pmol each in a 100 microliters injection volume. The method is very simple, and sensitive enough to permit the quantification of forphenicinol in the blood samples from man dosed with forphenicinol.  相似文献   

16.
A new calibration method for high-performance liquid chromatography was validated. The method was called single-injection calibration approach (SICA) because it allowed to obtain a complete calibration curve by means of a single injection of a standard solution containing several non-volatile and semi-volatile organic compounds at different concentration levels. The compounds studied included carboxylic acids, polyalcohols, carbohydrates and water-soluble vitamins. This method allowed a 1-7-fold reduction in the analysis time with regard to conventional calibration methods. The method was applied to three different chromatographic detection methods: refractive index (RI) detection, diode array detection (DAD) and inductively coupled plasma atomic emission detection (ICP-AED). Good linearity was achieved (r(2)>0.999) for the three detection methods but signal correction was required for RI detection and DAD. This fact demonstrated that ICP-AES was the most universal because the signal obtained for non-volatile and semi-volatile organic compounds was not a function of the chemical nature of the compound and only depended on the mass content of carbon. The method was validated by analyzing a reference non-fat milk powder sample as well as several real food samples (three fruit juices, four wines, three candies and a multivitamin complex).  相似文献   

17.
One CE method was established for detecting deferoxamine (DFO) and deferiprone (DFR) in plasma. For β‐thalassemia patients, DFO and DFR are major medicines to treat the iron overload caused by blood transfusion. Field‐amplified sample injection combined with sweeping was used for sensitivity enhancement in CE. This method was performed on an uncoated fused‐silica capillary. After liquid–liquid extraction, the plasma samples were electrokinetically injected into capillary at +10 kV for 180 s. The phosphate buffer (100 mM) containing 50 mM triethanolamine was used as the BGE (pH 6.6). Separation buffer was phosphate buffer (100 mM, pH 3.0) containing 150 mM SDS. This method showed good linearity (r ≥ 0.9960). Precision and accuracy were evaluated by the results of RSD and relative error of intrabatch and interbatch analyses, and all of the absolute values were less than 6.12%. The LODs (S/N = 3) were 200 ng/mL for DFO, and 25 ng/mL for DFR. The LOQ (S/N = 10) of DFO and DFR were 600 and 75 ng/mL, respectively. This method was applied for clinical applications of five β‐thalassemia patients.  相似文献   

18.
高效液相色谱法测定强化奶及食品中维生素D含量   总被引:6,自引:1,他引:5  
吴怀春  程华  田嘉荣  王喜生 《色谱》1997,15(1):43-45
介绍用反相高效液相色谱法(HPLC)测定食品中VD含量,样品经皂化、正己烷提取、正相HPLC净化,用反相HPLC定量分析。回收率为94.88%~99.70%,批内和批间CV分别为1.62%和2.12%。分析了奶粉、要素膳、肉松、儿保饮料等8种食品中VD含量,亦可用于各种食品中VD分析。  相似文献   

19.
A simple and sensitive analytical method for four isomers of glycopyrrolate in rat plasma was developed using cation‐selective exhaustive injection‐sweeping cyclodextrin‐modified electrokinetic chromatography (CSEI‐Sweeping‐CDEKC) for online enrichment combined with dispersive micro‐solid‐phase extraction pretreatment. The CSEI‐Sweeping‐CDEKC was conducted on an uncoated fused silica capillary (40.2 cm × 75 μm) with an applied voltage of –20 kV. The electrophoretic analysis was carried out in 30 mM phosphate solution at pH 2.0 containing 20 mg/mL sulfated‐β‐cyclodextrin and 5% acetonitrile. Under these optimized conditions, the detection limit for racemic glycopyrrolate was found to be 2.0 ng/mL and this method could increase 495‐fold detection sensitivity compared with the traditional injection method. Additionally, the parameters that affected the extraction efficiency of dispersive micro‐solid‐phase extraction were also examined systematically. The glycopyrrolate isomers in rat plasma samples as low as 0.0625 μg/mL were able to be separated and detected by capillary electrophoresis with the aid of CSEI‐sweeping. The findings of this study show that the dispersive micro‐solid‐phase extraction pretreatment coupled with CSEI‐Sweeping‐CDEKC is a rapid and convenient method for analyzing glycopyrrolate isomers in rat plasma.  相似文献   

20.
An interlaboratory study, with the participation of 8 laboratories, was conducted to evaluate a sodium dodecyl sulfate-capillary gel electrophoresis method for determination of adulteration of milk powder with soy and pea proteins. Calibration standards (0-8%, w/w, soy and pea protein in total protein) and adulterated skim milk powders (0-5%, w/w, soy and pea proteins in total protein) were produced. Vegetal proteins were determined after removal of milk proteins by pretreatment of the samples with tetraborate-EDTA buffer, pH 8.3. Repeatability standard deviations ranged from 9 to 15% and reproducibility standard deviations ranged from 25 to 30% in the samples containing 5% vegetal protein in total protein.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号