1.
Cationic polysaccharides containing N-hydroxypropyl-N,N,N-trimethylammonium substituents are widely used as conditioning agents for hair-care products. A sensitive method has been developed for the quantitation of these polymers. After acidic extraction from hair the polysaccharides are hydrolyzed using trifluoroacetic acid. The cationic monoglycosides are determined using liquid chromatography–tandem mass spectrometry (LC–MS–MS). The developed method is independent of hair treatment. Even hair cut from test persons after customary hair wash can be analyzed. After treatment of natural and bleached hair tresses using a real-life treatment procedure 180 g and 300 g of polymer per gram hair were quantified, respectively. Additionally the fragmentation mechanism of the cationic N-hydroxypropyl-N,N,N-trimethylammonium group during electrospray ionization was investigated. A mass loss of 60 Da in combination with loss of a single charge is observed and associated with cleavage of trimethylamine and a proton. It is assumed that this process is promoted by the anionic counter-ion which might be hydroxide in an aqueous environment.  相似文献   

2.
A sensitive LC–MS–MS method with electrospray ionization has been developed for determination of nikethamide in human plasma. After addition of atropine as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 mm × 2.1 mm, 5 μm particle, Agilent Zorbax SB-C18 column, with 45:55 (v/v) methanol–water containing 0.1% formic acid as mobile phase. LC–MS–MS was performed in multiple reaction monitoring mode using target fragment ions m/z 178.8 → 107.8 for nikethamide and m/z 289.9 → 123.8 for the internal standard. Calibration plots were linear over the range of 20.0–2,000 ng mL?1. The lower limit of quantification was 20.0 ng mL?1. Intra-day and inter-day precisions were better than 4.2 and 6.1%, respectively. Mean recovery of nikethamide from human plasma was in the range 65.3–71.1%.  相似文献   

3.
A simple and rapid LC–MS–MS assay was developed and validated for the quantitative determination of pitavastatin in human plasma. Sample pretreatment involved simple protein precipitation by addition of acetonitrile. Separation was on an Agilent 1.8 μm Zorbax SB-C18 column (150 mm × 4.6 mm) at 25 °C using isocratic elution with methanol–0.1% formic acid in water (85:15, v/v) at a flow rate of 0.4 mL min?1. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 422.0 → 290.1 for pitavastatin, and m/z 330.1 → 192.1 for paroxetine (IS). LC–MS–MS was found to improve the quantitation of pitavastatin in plasma and was successfully applied in pharmacokinetic studies.  相似文献   

4.
A new, rapid, and efficient method, multiple reaction monitoring liquid chromatography–tandem mass spectrometry, has been developed for analysis of nanafrocin in foodstuffs of animal origin. The researchers used a C18 stationary phase coupled with triple-quadrupole tandem mass spectrometry in negative-electrospray mode. The limits of detection (LOD) and quantification (LOQ) were 0.005 and 0.01 mg kg?1, respectively, in the matrixes. Detector response was found to be a linear function of concentration over the range 0.005–0.1 mg kg?1 in each matrix. Mean overall recovery (n = 10) of nanafrocin varied from 71 to 101%. The results show that identification and quantification of nanafrocin residues in foodstuffs of animal origin can be successfully achieved by use of the proposed LC–MS–MS method.  相似文献   

5.
A stability indicating RP-HPLC method for cephalexin has been developed and validated to identify and characterize potential degradation products. Drug was subjected to hydrolytic (acidic, basic, and neutral), oxidative, thermal, and photolytic stresses as per ICH guidelines Q1A (R2) and Q1B. Chromatographic separation was achieved on C8 column with mixture of ammonium acetate buffer pH 4.5 and acetonitrile in gradient mode as a mobile phase with PDA detection. Specificity of the method was established by peak purity studies. Method was validated as per ICH guideline Q2 (R1) for accuracy, precision, linearity, sensitivity, and robustness. Kinetics for each degradation condition was studied with respect to order of reaction and rate constant. Method was found to comply with acceptance criteria of validation parameters with respect to specificity (peak purity greater than 0.999) linearity (r 2 greater than 0.99), accuracy (% recovery in the range of 98–102%), and precision (% RSD not more than 2). A total of six degradation products were generated in different stress conditions; these were identified and structures were proposed using LC–MS/MS. Cephalexin undergoes degradation in almost all the conditions. The developed stability indicating method is suitable for analysis of stability samples as it adequately separates all degradation products. Degradation products generated in photolytic and oxidative conditions are reported for the first time.  相似文献   

6.
Five adrenolytic drugs have been analyzed by liquid chromatography–mass spectrometry (LC–MS). Samples were prepared by solid-phase microextraction (SPME) using polypyrrole fibers coated on stainless steel support as an adsorbent for the drugs. Adsorption efficiencies were 95% and were close for all the drugs investigated. Relative standard deviations (RSD), calculated for samples prepared in standard solutions, were in the range 2.5–13%, however RSD values for the drugs in human plasma were 2.5–4.5%. Using LC–MS the limit of detection (LOD) and the limit of quantification (LOQ) were in the ranges 0.11–0.18 and 0.39–0.54 ng mL−1, respectively, for the five drugs.  相似文献   

7.
Blazics  Balazs  Ludanyi  Krisztina  Szarka  Szabolcs  Kery  Agnes 《Chromatographia》2008,68(1):119-124
Gas and liquid chromatography coupled with mass spectrometry was applied to solve difficulties and reinvestigate the serious matrix problems affecting analysis of the active compounds in Euphrasia rostkoviana Hayne. The main groups of compounds were obtained by extracting the herb stepwise with n-hexane, chloroform, ethyl acetate and methanol. Polyamide column chromatography facilitated further separation. Phenolic/flavonoid- and terpenoid-type molecules were studied by GC–MS, HPLC and LC–MS–MS. The β-sitosterol content of the herb was determined by gas chromatography with flame ionisation detection (GC-FID). Caffeic acid, chlorogenic acid, coumaric acid and flavonoid glycosides of apigenin, luteolin, rhamnetine (hexoside), kaempferol (both hexoside and rutinoside) and quercetin (rutinoside) were identified in the fractions of the methanolic extract.  相似文献   

8.
The contribution of explosive trace detection in samples from the hands of suspects has been fundamental in several forensic cases involving terrorists. This paper describes a method for the rapid extraction and unequivocal confirmation of some high potential explosives (trinitrotoluene, cyclotrimethylenetrinitramine, pentaerythritol tetranitrate, nitroglycerin) and two stabilizer (diphenylamine and ethylcentralite) residues in hand-swabs using liquid chromatography–tandem mass spectrometry. The extraction procedure of the analytes from the swabs is realized by solvent elution and the extracts are directly analyzed. Recoveries from spiked swabs range from 78 to 96%; the limits of quantification are between 0.04 and 1.8 ng injected and the inter-day method precision is less than 15%. The developed procedure was applied to the detection of explosives traces in samples after handling tests.  相似文献   

9.
Arafat  Tawfiq  Arafat  Basil  Abu Awwad  Ahmad  Schmitz  Oliver J. 《Chromatographia》2016,79(11):685-692

A sensitive, high-throughput and economic liquid chromatographic method for determination of fenofibric acid in human plasma was developed and validated by ultraviolet detection and tandem mass spectrometry, then applied in pharmacokinetic study to investigate Lipanthyl™ 200 mg MC bioavailability under food and fasting conditions. Fenofibric acid with 2-chloro fenofibric acid-d6 (internal standard) was extracted from 100 µL of human plasma by acetonitrile in a single extraction step. 25 and 2 µL from supernatant were injected onto ACE column, 50 mm, 5 micron with 4.6 mm inner diameter for LC–UV and 2.1 mm for LC–MS/MS, and both systems were eluted isocratically by water:methanol:formic acid (35:65:0.1, v/v/v), with a constant flow rate of 1 mL min−1. The established calibration curve was linear between 0.05–20 µg mL−1, and the within- and between-day precisions were all below 13 % in both LC–MS/MS and LC–UV systems during validation, and accuracies ranged between 91 and 112 %. Twenty-eight healthy adult subjects participated in this clinical study, and the pharmacokinetic parameters including coefficient of variation were calculated and discussed. A dramatic decrease in C max and AUC0-72 (3.63- and 1.85-fold, respectively) were observed for Lipanthyl™ MC under fasting conditions with more variable inter subject measurements comparing to the fed state.

  相似文献   

10.
A sensitive and reliable method by liquid chromatography–tandem mass spectrometry was developed for the simultaneous determination of carbadox, mequindox, olaquindox and quinocetone in swine feed. The analytes were extracted from swine feed with acetonitrile/water (60:40, v/v), and then further purified by solid-phase extraction using Oasis HLB cartridges. The mean recovery values ranged from 83–108%, and intra-day and inter-day variation were <10.8 and 9.6%, respectively. The limits of quantification for the four compounds were <20 μg kg?1. This procedure is applicable for detecting the four quinoxaline-1,4-dioxides in swine feed.  相似文献   

11.
A simple, specific and sensitive column liquid chromatography–tandem mass spectrometry method has been developed for the determination of amphotericin B in human cerebrospinal fluid. Samples were prepared by dilution with methanol and quantitated by MS–MS detection in the positive mode. The determination was validated in the concentration range of 0.5–100 ng mL?1 using 100 μL of human cerebrospinal fluid. The method was successfully used to support routine therapeutic drug monitoring.  相似文献   

12.
Flupentixol and an internal standard, loperamide were extracted from human plasma by liquid–liquid extraction and analyzed on a Thermo Hypersil HyPURITY C18 column, with 10 mM ammonium acetate–acetonitrile–methanol (26:62:12, v/v/v) as mobile phase, coupled with electrospray ionization mass spectrometry (ESI–MS). The protonated analyte was quantified by selected-ion monitoring (SIM) with a quadrupole mass spectrometer in a positive-ion mode. The calibration curve was linear (r = 0.9990) over the concentration range: 0.039–2.5 ng mL?1. Intra-day and inter-day precision (RSD%) were less than 13.05%. The established method was successfully applied for the determination of pharmacokinetics of flupentixol in human plasma.  相似文献   

13.
Simple and specific analytical methods for the quantitative determination of sesquiterpenoids from various species of Artemisia plant samples were developed. By LC–UV, LC–ELSD, the separation was achieved by reversed-phase chromatography on a C18 column with water and acetonitrile both containing 0.025% trifluoroacetic acid as the mobile phase. In the LC–MS system, trifluoroacetic acid was replaced by 0.1% formic acid. The wavelength used for quantification of sesquiterpenoids with a diode array detector was 205 nm. The limits of detection by LC–MS was found to be 5, 10, 25, 50, 50 ng mL?1. The limits of detection by LC–UV and LC–ELSD were found to be 5.0, 3.0, 100, 100, 7.5 μg mL?1, by LC–UV and 50, 25, 30, 100 and 75 μg mL?1 by LC–ELSD. LC–mass spectrometry coupled with electrospray ionization (ESI) interface is described for the identification and quantification of sesquiterpenoids in various plant samples. This method involved the use of the [M + H]+ ions of sesquiterpenoids in the positive ion mode with extractive ion monitoring.  相似文献   

14.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

15.
A simple and specific method for the simultaneous determination of eleutherosides B and E in powdered rhizomes of Eleutherococcus senticosus extract and in solid and liquid dietary supplements was developed and validated. E. senticosus extracts, often mixed with other plants or herbal extracts, are widely used in food supplements because of the tonic and adaptogenic activities referred to the eleutherosides B and E. In this study, samples were analyzed by a liquid chromatography-electrospray tandem mass spectrometry (LC–ESI-MS/MS) method operated in single reaction monitoring (SRM). Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values were fixed at 3 μg L?1 and 10 μg L?1, respectively, whereas linearity was established within 10–1,000 μg L?1 range for both compounds. Good precision was obtained for both eleutherosides in terms of intra-day precision (RSD % lower than 4 %) and inter-day precision (RSD % lower than 6 %). Good percentage recoveries were obtained for both eleutherosides (91.5–103.6 %). Finally, the developed method was successfully applied to analyze a number of solid and liquid commercial dietary supplements containing E. senticosus extracts, also mixed with other herbal extracts.  相似文献   

16.
Current role of LC–MS(/MS) in doping control   总被引:1,自引:0,他引:1  
Liquid chromatography–(tandem) mass spectrometry (LC–MS/MS) has revolutionized the detection assays used in doping control analysis over the last decade. New methods have enabled the determination of drugs that were formerly difficult to detect or undetectable at preceding sample concentrations, and complex and/or time-consuming procedures based on alternative chromatographic–mass spectrometric or immunochemical principles have been replaced by faster, more comprehensive and robust assays. A critical overview of the contributions of LC–MS(/MS) to sports drug testing is provided, including recent developments regarding low and high molecular weight drugs.  相似文献   

17.
A rapid, precise, and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed for the characterization of stressed degradation products of mirabegron. It is used in the treatment of overactive bladder and administered to treat urinary symptoms such as urgency or frequency and incontinence. It also works by relaxing the muscles around bladder.

Mirabegron was subjected to hydrolysis (acidic, alkaline, and neutral) and peroxidation, as per ICH-specified conditions. The drug showed degradation under stress conditions. However, it was stable to neutral conditions. A total of seven degradation products were observed and the chromatographic separation of the drug and its degradation products was achieved on X-TerraRP-8 (250 mm × 4.6 mm, i.d., 5 µm) column using 0.01 M ammonium acetate as mobile phase-A and 60:40 ratio of acetonitrile (ACN):water as mobile phase-B. The degradation products were characterized by LC–MS/MS and its fragmentation pathways were proposed. Probable possible structures were drawn based on parent and daughter molecular ions. One peroxide degradant impurity was isolated using preparative LC and characterized using liquid chromatography–mass spectrometry and NMR data.  相似文献   

18.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

19.
An LC–MS–MS-based procedure for determination in hair of 14 different drugs of abuse belonging to the classes cocaine, amphetamine-like compounds, opiates, and hallucinogens has been developed. A pressurized-liquid extraction procedure was used and proved useful for quantitative recovery of all the analytes tested. This procedure, in conjunction with a simple decontamination step, performed to avoid false-positive samples, enabled the detection of all the analytes with LOQ ranging from 1.8 to 16 pg mg?1 and accuracy varying from 85 to 111 %. The procedure was validated in accordance with the SOFT/AAFS guidelines and seems to be suitable for routine determination of the drugs tested in hair.  相似文献   

20.
Alberti  Agnes  Blazics  Balazs  Kery  Agnes 《Chromatographia》2008,67(1):107-111

A reversed-phase high-performance liquid chromatography method with UV detection was developed for determination of [(N-morpholine)methylene]daunorubicin hydrochloride (DD-M) during studies of its stability. In this LC method the following were used: an RP-column, the mobile phase—acetonitrile:methanol:solution A (9:1:10 v/v/v) [solution A contains 2.88 g of sodium laurilsulfate and 1.6 mL of phosphoric acid(V)] with a flow rate of 1.4 mol L−1 and quinine hydrochloride as an internal standard. The detection wavelength was 254 nm. The method was validated with regard to linearity, limit of detection, limit of quantitation, selectivity and precision. Hydrolysis of the DD-M catalyzed by hydrogen ions in hydrochloric acid and a spontaneous reaction of the DD-M degradation under the influence of the water in sodium hydroxide took place. The thermodynamic parameters of these reactions—energy, enthalpy and entropy of activation—were calculated. It was observed that a positive salt effect occurred in hydrochloric acid.