首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
The retention and complexation mechanisms of a herbicide series were studied from a chromatographic approach using a novel column called “Nautilus®”. The effects of water fraction and the hydroxy-propyl-β-cyclodextrin (HP-β-CD) concentration in the mobile phase were analysed in relation to the column temperature. Two retention models of phenoxy-propionic acid (PPA) derivatives were investigated. It was shown that the retention mechanism was led by free PPA herbicide for low HP-β-CD concentrations and by the PPA/HP-β-CD complex for the highest ones. In addition, an enthalpy-entropy compensation study revealed that both the solute retention and complexation mechanisms were independent of the number of chlorine atoms in the structure. Also the thermodynamic results showed that (1) the retention process depended on the water fraction (X) in the mobile phase and (2) the PPA/HP-β-CD complexation mechanism was shown to be entropically controlled.  相似文献   

2.
Herein a simple analytical method is presented for the characterization of biomolecule adsorption on cyclo olefin polymer (COP, trade name: Zeonor®) substrates which are widely used in microfluidic lab-on-a-chip devices. These Zeonor® substrates do not possess native functional groups for specific reactions with biomolecules. Therefore, depending on the application, such substrates must be functionalized by surface chemistry methods to either enhance or suppress biomolecular adsorption. This work demonstrates a microfluidic method for evaluating the adsorption of antibodies and oligonucleotides surfaces. The method uses centrifugal microfluidic flow-through chips and can easily be implemented using common equipment such as a spin coater. The working principle is very simple. The user adds 40 L of the solution containing the sample to the starting side of a microfluidic channel, where it is moved through by centrifugal force. Some molecules are adsorbed in the channel. The sample is then collected at the other end in a small reservoir and the biomolecule concentration is measured. As a pilot application, we characterized the adsorption of goat anti-human IgG and a 20-mer DNA on Zeonor®, and on three types of functionalized Zeonor: 3-aminopropyltriethoxysilane (APTES) modified surface with mainly positive charge, negatively charged surface with immobilized bovine serum albumin (BSA), and neutral, hydrogel-like film with polyethylene glycol (PEG) characteristics. This simple analytical approach adds to the fundamental understanding of the interaction forces in real, microfluidic systems. This method provides a straightforward and rapid way to screen surface compositions and chemistry, and relate these to their effects on the sensitivity and resistance to non-specific binding of bioassays using them. In an additional set of experiments, the surface area of the channels in this universal microfluidic chip was increased by precision milling of microscale trenches. This modified surface was then coated with APTES and tested for its potential to serve as a unique protein dilution feature.  相似文献   

3.
4.
Often there are several chromatographic systems, i.e., combinations of mobile and stationary phases, available to solve a certain separation problem. Essential differences of these chromatographic systems are the separation factors and the efficiencies. For preparative applications in addition also the column saturation capacities and solubility limits are of importance. The impact of all these parameters appears to be rather well understood for conventional overloaded elution chromatography using a single column. In the last years the continuous simulated moving bed (SMB) process was increasingly used as a powerful alternative to batch elution since increased productivities and reduced solvent consumptions could be realised. However, the selection of suitable chromatographic systems is more sophisticated for this process. In this paper five different chromatographic systems capable of separating the enantiomers of mandelic acid are compared based on the achievable productivities using SMB chromatography. For these five systems the adsorption isotherms have been determined experimentally. Subsequently, an analysis of the SMB process was performed numerically using a well-established model.  相似文献   

5.
Here we report a strand-specific fluorescent homogeneous assay format for rapid polymerase chain reaction (PCR). A number of similar assays are commonly used for research applications and are an ideal solution for a closed tube quantitative PCR. These assays use fluorescent resonant energy transfer (FRET) between donor and acceptor fluorescent moieties as the reporting mechanism. However, for different reasons these assays do not report amplification when very rapid cycling times are used. This is because current assays, such as TaqMan®, are limited, in terms of assay speed, by the 5′-3′ exonuclease activity of Taq DNA polymerase. Other assays based on hybridisation require either a complex de-conformational event to occur, or require more than one probe to report amplification. Reducing the complexity of the experiment reduces costs in terms of design, optimisation and manufacture. Here, we describe ResonSense® chemistries that use a simple linear fluorescent-labelled probe and a DNA minor-groove binding dye as either donor or acceptor moieties in a homogeneous assay format on the LightCycler®. This assay format will provide for rapid analysis of samples and so it is particularly well suited to point-of-use testing.  相似文献   

6.
The chromatographic performance of a Hypercarb column was studied using some five-membered heterocyclic compounds. Significant retention of these molecules was observed with water/acetonitrile eluents. The influence of the organic modifier on retention was studied and interpreted on the basis of intermolecular interactions. The order of retention of solutes on Hypercarb does follow their polarity order. Dispersion interactions undoubtedly have an influence, but do not determine the elution order of solutes. From the results obtained, it appears that the retention of the investigated substances is defined by interaction of polarized or polarizable functional groups in the samples with the graphite surface of the Hypercarb.  相似文献   

7.
8.
The anti-influenza drug Tamiflu® is synthesized from enzymatically derived, enantiomerically pure, and readily available cis-1,2-dihydrocatechol.  相似文献   

9.
A robust optical composite thin film dissolved oxygen sensor was fabricated by ionically trapping the dye ruthenium(II) tris(4,7-diphenyl-1,10-phenanthroline) dichloride in a blended fluoropolymer matrix consisting of Nafion® and Aflas®. Strong phosphorescence, which was strongly quenched by dissolved oxygen (DO), was observed when the sensor was immersed in water. The sensor was robust, optically transparent, with good mechanical properties. Fast response, of a few seconds, coupled with sensitivity of about 0.1 mg L−1 (DO) over the range 0-30 mg L−1 and resistance to leaching, were also exhibited by this system. The Stern-Volmer (SV) plot exhibited slight downward turning at all oxygen concentrations. A linear plot was obtained when the SV equation was modified to account for the varying sensitivity of dye molecules in the matrix to the quencher. Good long term stability was observed.  相似文献   

10.
Summary {\rtf1\ansi\ansicpg1250\deff0\deflang1038\deflangfe1038\deftab708{\fonttbl{\f0\froman\fprq2\fcharset238{\*\fname Times New Roman;}Times New Roman CE;}} \viewkind4\uc1\pard\f0\fs24 We have developed a method for analyzing neutron activated sample data by using Microsoft Excel as the analysis engine. A simple technique for inputting data is based on report files generated by Canberra’s Genie-2000 spectroscopy system but could be easily modified to support other vendors having report formats with consistent text placement. A batch program handles operating an automatic sample changer, acquiring the data, and analyzing the spectrum to create a report of the peak locations and net area. The entire report is then transferred to within an Excel spreadsheet as the source data for neutron activation analysis. Unique Excel templates have been designed, for example, to accommodate short-lived and long-lived isotopes. This process provides us with a largely integrated solution to NAA while providing the results in an industry standard spreadsheet format. This software is ideally suited for teaching and training purposes. \par }  相似文献   

11.
Summary A liquid-solid chromatographic pre-fractionation of naturally occurring phthalides has been developed. The LSC was carried out on a column of silica applying a 1–50% gradient elution of diethyl ether (containing 2% methanol) in pentane. The enrichment in the fractions led to better possibilities for a gas chromatographic separation and isolation allowing further studies by spectroscopic methods. Ligustilide may easily isomerize during GC as a result of ageing of the column.  相似文献   

12.
Design and development of a dynamic interfacial pressure detector (DIPD) is reported. The DIPD measures the differential pressure as a function of time across the liquid-liquid interface of organic liquid drops (i.e., n-hexane) that repeatedly grow in water at the end of a capillary tip. Using a calibration technique based on the Young-Laplace equation, the differential pressure signal is converted, in real-time, to a relative interfacial pressure. This allows the DIPD to monitor the interfacial tension of surface active species at liquid-liquid interfaces in flow-based analytical techniques, such as flow injection analysis (FIA), sequential injection analysis (SIA) and high performance liquid chromatography (HPLC). The DIPD is similar in principle to the dynamic surface tension detector (DSTD), which monitors the surface tension at the air-liquid interface. In this report, the interfacial pressure at the hexane-water interface was monitored as analytes in the hexane phase diffused to and arranged at the hexane-water interface. The DIPD was combined with FIA to analytically measure the interfacial properties of cholesterol and Brij®30 at the hexane-water interface. Results show that both cholesterol and Brij®30 exhibit a dynamic interfacial pressure signal during hexane drop growth. A calibration curve demonstrates that the relative interfacial pressure of cholesterol in hexane increases as the cholesterol concentration increases from 100 to 10,000 μg ml−1. An example of the utility of the DIPD as a selective detector for a chromatographic separation of interface-active species is also presented in the analysis of cholesterol in egg yolk by normal-phase HPLC-DIPD.  相似文献   

13.
Abstract

Unmodified standard gas chromatographs are reported to be useful for the determination of a large number of ambient hydrocarbons. Packing of standard injector glass liners with an adsorbent permits thermal desorption in the injector on to the chromatographic column. Coupling to a personal sampling pump permits exposure-related sampling. The potential of the technique is illustrated by applications with the Tenax GC adsorbent. Precautions required to avoid artifacts when working in the subnanogram range are described.  相似文献   

14.
In this paper we describe how the existing theories to describe retention and peak width in isocratic and gradient-elution liquid chromatography can be expanded to describe the retention behaviour of natural and synthetic repetitive polymers, which feature distributions of molecules with different masses (and often different structures) rather than unambiguous molecular formulas. For polydisperse samples, it is vital that the model accommodates (isocratic) elution of sample components before the onset of a gradient, elution during the gradient, and elution after the completion of the gradient. The expanded models can readily be implemented in standard spreadsheet software, such as Excel. We have created such spreadsheets based on the conventional model for retention in reversed-phase liquid chromatography (RPLC) and on two different models for retention in normal-phase liquid chromatography. The implementation allows an easy visualization of the theoretical concept. Up to three different polymeric series can be entered, with a total of up to 100 peaks being computed and displayed in isocratic or gradient-elution chromatograms. Also visualized are "retention models" (diagrams of isocratic retention vs. composition) and "calibration curves" (retention or elution composition vs. molecular mass or degree of polymerization). The coefficients in the isocratic retention model may be correlated, as has often been observed in RPLC. It is shown that under certain conditions such a correlation corresponds to the existence of so-called critical (isocratic) conditions, at which all the members of a given polymeric series (same composition and end groups, different number of repeat units) show co-elution.  相似文献   

15.
A series of 2,4-diphenylthiazole derivatives were synthesized and directly fluorinated at the 5-position by reaction with the N-F fluorinating reagent Accufluor®. Although fluorination occurred selectively at the thiazole ring, it was always incomplete and thus yields for the novel fluorinated products were low to moderate (19-43%) following purification to remove starting material. Nonetheless, the target compounds were obtained in a convenient and straightforward manner. Selectfluor® was not as effective as Accufluor® as it gave a trace amount of the 5-chlorothiazole that was difficult to remove by chromatography.  相似文献   

16.
R. Snel 《Chromatographia》1986,21(5):265-268
Summary A simple gas chromatographic system has been developed for the rapid on-line analysis of light Fischer-Tropsch products. This involves a single chromatography fitted with two columns, a porous-layer open-tubular column coated with KCl deactivated alumina and a packed Porapak-Q column. The capillary column separates the 16 most common C1−C4 hydrocarbons and permits a reasonable analysis of the hydrocarbons in the C5−C7 range. The packed column is used for the separation of methane, carbon monoxide, carbon dioxide, water and methanol. Retention characteristics for the analysis on the capillary column are presented. The total analysis cycle is 30 minutes.  相似文献   

17.
Many different strategies of reversed phase high performance liquid chromatographic (RP-HPLC) method development are used today. This paper describes a strategy for the systematic development of ultrahigh-pressure liquid chromatographic (UHPLC or UPLC) methods using 5 cm × 2.1 mm columns packed with sub-2 μm particles and computer simulation (DryLab® package). Data for the accuracy of computer modeling in the Design Space under ultrahigh-pressure conditions are reported. An acceptable accuracy for these predictions of the computer models is presented. This work illustrates a method development strategy, focusing on time reduction up to a factor 3–5, compared to the conventional HPLC method development and exhibits parts of the Design Space elaboration as requested by the FDA and ICH Q8R1. Furthermore this paper demonstrates the accuracy of retention time prediction at elevated pressure (enhanced flow-rate) and shows that the computer-assisted simulation can be applied with sufficient precision for UHPLC applications (p > 400 bar). Examples of fast and effective method development in pharmaceutical analysis, both for gradient and isocratic separations are presented.  相似文献   

18.
Summary Mutual diffusion coefficients of two gases A and B can be determined in an empty gas chromatographic column by letting component B enter at an intermediate position of the column and continuously flow through a part only of it, as a carrier gas. The other component A is injected in a small amount instantaneously at the closed end of the column with the detector placed at the other end. By repeatedly stopping and then restoring after a short time the flow of B, narrow extra peaks are produced on the chromatographic elution curve, owing to diffusion of A into B. An equation is derived giving the area under the curve of each stop-peak as a function of time of the corresponding stop. Plotting the experimental data according to this equation permits the determination of the diffusion coefficient of A into B. Some results obtained by this method show negligible variations with changes in the experimental parameters.  相似文献   

19.
1.INTRODUCTIONThechromatographicproblemistorelatetheconcentrationprofileofthebandattheoutletofthecolumntotheequilibriumisothelm,themasstransferkineticsandtheprofileoftheinjectionbandandperformtheoptimumdesignofseparationprocess['J.Togettheobjective,Itisnecessarytoidentifythesystemof.ProjectsupPOrtedbyTheNationalNaturalScienceFoundationofChinatheliquidadsorptionchromatographylinearornon-linear,andthendeterminethethermodynamicanddynamicsparametersofthesystemaccuratelysothatthecomputersim…  相似文献   

20.
An experimental and theoretical study was conducted of the column characterization technique in which plate heights determined using the conventional pulse-response method are compared with those determined using a bi-directional method where an eluite sample is introduced into one end of a chromatographic column and elution occurs at the same end after the flow direction is reversed inside the column. Experiments are presented for a micropellicular HPLC column before and after its performance has been degraded by repeated sample injections, for a low-pressure column containing nonporous glass particles, and for an HPLC column containing particles with 300 Å pores. The results obtained are interpreted in terms of several different theories which apply in various Fourier number ranges. It was shown that the transcolumn contribution to convective dispersion in a chromatographic column is largely responsible for the difference observed between conventional and bi-directional plate-height measurements and that a collocation method can be employed to develop a useful analytical expression for this contribution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏