首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Won JI  Meagher RJ  Barron AE 《Electrophoresis》2005,26(11):2138-2148
We demonstrate the feasibility of end-labeled free-solution electrophoresis (ELFSE) separation of DNA using genetically engineered protein polymers as drag-tags. Protein polymers are promising candidates for ELFSE drag-tags because their sequences and lengths are controllable not only to generate monodisperse polymers with high frictional drag, but also to meet other drag-tag requirements for high-resolution separations by microchannel electrophoresis. A series of repetitive polypeptides was designed, expressed in Escherichia coli, and purified. By performing an end-on conjugation of the protein polymers to a fluorescently labeled DNA oligomer (22 bases) and analyzing the electrophoretic mobilities of the conjugate molecules by free-solution capillary electrophoresis (CE), effects of the size and charge of the protein polymer drag-tags were investigated. In addition, the electrophoretic behavior of bioconjugates comprising relatively long DNA fragments (108 and 208 bases) and attached to uncharged drag-tags was observed, by conjugating fluorescently labeled polymerase chain reaction (PCR) products to charge-neutral protein polymers, and analyzing via CE. We calculated the amount of friction generated by the various drag-tags, and estimated the potential read-lengths that could be obtained if these drag-tags were used for DNA sequencing in our current system. The results of these studies indicate that larger and uncharged drag-tags will have the best DNA-resolving capability for ELFSE separations, and that theoretically, up to 233 DNA bases could be sequenced using one of the protein polymer drag-tags we produced, which is electrostatically neutral with a chain length of 337 amino acids. We also show that denatured (unfolded) polypeptide chains impose much greater frictional drag per unit molecular weight than folded proteins, such as streptavidin, which has been used as a drag-tag before.  相似文献   

2.
Buchholz BA  Barron AE 《Electrophoresis》2001,22(19):4118-4128
The ability of a polymer matrix to separate DNA by capillary electrophoresis (CE) is strongly dependent upon polymer physical properties. In particular, recent results have shown that DNA sequencing performance is very sensitive to both the average molar mass and the average coil radius of the separation matrix polymers, which are affected by both polymer structure and polymer-solvent affinity. Large polymers with high average molar mass provide the best DNA sequencing separations for CE, but are also the most challenging to characterize with accuracy. The methods most commonly used for the characterization of water-soluble polymers with application in microchannel electrophoresis have been gel permeation chromatography (GPC) and intrinsic viscosity measurements, but the limitations and potential inaccuracies of these approaches, particularly for large or novel polymers and copolymers, press the need for a more universally accurate method of polymer molar mass profiling for advanced DNA separation matrices. Here, we show that multi-angle laser light scattering (MALLS) measurements, carried out either alone or in tandem with prior on-line sample fractionation by GPC, can provide accurate molar mass and coil radius information for polymer samples that are useful for DNA sequencing by CE. Wider employment of MALLS for characterization of novel polymers designed as DNA separation matrices for microchannel electrophoresis should enable more rapid optimization of matrix properties and formulation, and assist in the development of novel classes of polymer matrices.  相似文献   

3.
A number of significant improvements in the electrophoretic performance and design of DNA sequencing devices have culminated in the introduction of truly industrial grade production scale instruments. These instruments have been the workhorses behind the massive increase in genomic sequencing data available in public and private databases. We highlight the recent progress in aspects of capillary electrophoresis (CE) that has enabled these achievements. In addition, we summarize recent developments in the use of microfabricated devices for DNA sequencing that promise to bring the next leap in productivity.  相似文献   

4.
Coope RJ  Marziali A 《Electrophoresis》2005,26(11):2128-2137
High-throughput capillary array electrophoresis (CAE) instruments for DNA sequencing suffer to varying degrees from read length degradation associated with electrophoretic current decline and inhibition or delay in the arrival of fragments at the detector. This effect is known to be associated with residual amounts of large, slow-moving fragments of template or genomic DNA carried through from sample preparation and sequencing reactions. Here, we investigate the creation and expansion of an ionic depletion region induced by overloading the capillary with low-mobility DNA fragments, and the effect of growth of this region on electrophoresis run failure. Slow-moving fragments are analytically and experimentally shown to reduce the ionic concentration of the downstream electrolyte. With injection of large fragments beyond a threshold quantity, the anode-side boundary of the nascent depletion region begins to propagate toward the anode at a rate faster than the contaminant DNA migration. Under such conditions, the depletion region expands, the capillary current declines dramatically, and the electrophoresis run yields a short read length or fails completely.  相似文献   

5.
Bromberg A  Mathies RA 《Electrophoresis》2004,25(12):1895-1900
A high-throughput homogeneous immunoassay for the sensitive detection of 2,4,6-trinitrotoluene (TNT) has been developed using radial capillary array electrophoresis microdevices. Samples consisting of equilibrium mixtures of anti-TNT antibody (Ab), fluorescein-labeled TNT, and various concentrations of unlabeled TNT were electrokinetically injected into 48 channels of a radial capillary array electrophoresis microchannel plate. The rapid electrophoretic separation allows us to analyze the equilibrium ratio formed by the competition between the labeled and the unlabeled TNT for Ab binding. The simultaneous parallel TNT separations facilitate determination of a calibration curve for the TNT assay, which has high sensitivity (LOD, 1 ng/mL) and a wide dynamic range (1-300 ng/mL).  相似文献   

6.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

7.
This review focuses on some recent advances in realizing microfabricated capillary array electrophoresis (microCAE). In particular, the development of a novel rotary scanning confocal fluorescence detector has facilitated the high-speed collection of sequencing and genotyping data from radially formatted microCAE devices. The concomitant development of a convenient energy-transfer cassette labeling chemistry allows sensitive multicolor labeling of any DNA genotyping or sequencing analyte. High-performance hereditary haemochromatosis and short tandem repeat genotyping assays are demonstrated on these devices along with rapid mitochondrial DNA sequence polymorphism analysis. Progress in supporting technology such as robotic fluid dispensing and batched data analysis is also presented. The ultimate goal is to develop a parallel analysis platform capable of integrated sample preparation and automated electrophoretic analysis with a throughput 10-100 times that of current technology.  相似文献   

8.
The present review covers papers published in the years 1997 and 1998 on DNA sequencing by capillary and microdevice electrophoresis. The article does not include other electrophoretic DNA applications such as analysis of oligonucleotides, genotyping, and mutational analysis. Capillary gel electrophoresis (CGE) is starting to become a viable competitor to slab gel electrophoresis for DNA sequencing. Commercially available multicapillary array sequencers are now entering sequencing facilities which to date have totally relied on traditional slab gel technology. CGE research on DNA sequencing therefore becomes increasingly concerned with the critical task of fine-tuning the operational parameters to create robust sequencing systems. Electrophoretic microdevices are being considered the next technological step in DNA sequencing by electrophoresis.  相似文献   

9.
21世纪毛细管电泳技术及应用发展趋势   总被引:8,自引:0,他引:8  
在21世纪,毛细管电泳技术面临着新的挑战和机遇,在其检测手段,仪器的小型化和集成化,以及分离模式上都存在着极大的发展空间,文中针对这三方面的发展趋势和毛细管电泳的应用进行了讨论。  相似文献   

10.
Capillary electrophoresis of inorganic anions   总被引:1,自引:0,他引:1  
This review deals with the separation mechanisms applied to the separation of inorganic anions by capillary electrophoresis (CE) techniques. It covers various CE techniques that are suitable for the separation and/or determination of inorganic anions in various matrices, including capillary zone electrophoresis, micellar electrokinetic chromatography, electrochromatography and capillary isotachophoresis. Detection and sample preparation techniques used in CE separations are also reviewed. An extensive part of this review deals with applications of CE techniques in various fields (environmental, food and plant materials, biological and biomedical, technical materials and industrial processes). Attention is paid to speciations of anions of arsenic, selenium, chromium, phosphorus, sulfur and halogen elements by CE.  相似文献   

11.
We review the wide range of polymeric materials that have been employed for DNA sequencing separations by capillary electrophoresis. Intensive research in the area has converged in showing that highly entangled solutions of hydrophilic, high molar mass polymers are required to achieve high DNA separation efficiency and long read length, system attributes that are particularly important for genomic sequencing. The extent of DNA-polymer interactions, as well as the robustness of the entangled polymer network, greatly influence the performance of a given polymer matrix for DNA separation. Further fundamental research in the field of polymer physics and chemistry is needed to elucidate the specific mechanisms by which DNA is separated in dynamic, uncross-linked polymer networks.  相似文献   

12.
Planar microfluidic devices have emerged as effective tools for the electrophoretic separation of a variety of different DNA inputs. The advancement of this miniaturized platform was inspired initially by demands placed on electrophoretic performance metrics by the human genome project and has provided a viable alternative to slab gel and even capillary formats due to its ability to offer high resolution separations of nucleic acid materials in a fraction of the time associated with its predecessors, consumption of substantially less sample and reagents while maintaining the ability to perform many separations in parallel for realizing ultra-high throughputs. Another compelling advantage of this separation platform is that it offers the potential for integrating front-end sample preprocessing steps onto the separation device eliminating the need for manual sample handling. This review aims to compile a recent survey of various electrophoretic separations using either glass or polymer-based microchips in the areas of genotyping and DNA sequencing as well as those involving the growing field of DNA-based forensics.  相似文献   

13.
Huang MF  Huang CC  Chang HT 《Electrophoresis》2003,24(17):2896-2902
The analysis of double-stranded (ds) DNA fragments by capillary electrophoresis (CE) using poly(ethylene oxide) (PEO) solution containing gold nanoparticles (GNPs) is presented, focusing on evaluating size dependence of the GNPs and PEO on resolution and speed. To prevent the interaction of the capillary wall with DNA, the capillary was dynamically coated with polyvinylpyrrolidone. Using different PEO solutions containing GNPs ranging in diameter from 3.5 to 56 nm, we have achieved reproducible, rapid, and high-resolution DNA separations. The results indicate that the sizes of PEO and GNPs as well as the concentration of PEO affect resolution. The separation of DNA ranging in size from 8 to 2176 base pairs (bp) was accomplished in 5 min using 0.2% PEO (8 MDa) containing 56 nm GNPs. We have also demonstrated the separations of the DNA fragments ranging from 5 to 40 kbp using 0.05% PEO (2 MDa) containing 13 nm GNPs or 0.05% PEO (4 MDa) containing 32 nm GNPs. With very low viscosity (< 15 cP), automatic replacement of the sieving matrices is easy, indicating a great potential for high-throughput DNA analysis using capillary array electrophoresis systems.  相似文献   

14.
This review focuses on capillary electrophoretic separations performed on capillary electrophoresis chips (CE chips) with hydrodynamically closed separation systems in a context with transport processes (electroosmotic flow (EOF)) and hydrodynamic flow (HDF)) that may accompany the separations in these devices. It also reflects some relevant works dealing with conventional CE operating under such hydrodynamic conditions. The use of zone electrophoresis (ZE), isotachophoresis (ITP) and their on-line combination (ITP-ZE) on the single-column and column-coupling CE chips with the closed separation systems and related problems are key topics of the review. Some attention is paid to sample pretreatment in the separations performed on the CE chips. Here, mainly potentialities of the ITP-ZE combination in trace analysis applications of the miniaturized systems are discussed in a broader extent. Links between the ZE separation and detection provide a frame for the discussion of current status of the detection on the CE chips. Analytical applications illustrate potentialities of the CE chips operating with the closed separation systems (suppressed HDF and EOF) to the determination of small ions present in various matrices by ZE, ITP and ITP-ZE.  相似文献   

15.
Li Q  Liu Z  Monroe H  Culiat CT 《Electrophoresis》2002,23(10):1499-1511
We have developed a highly versatile platform that performs temperature gradient capillary electrophoresis (TGCE) for mutation/single-nucleotide polymorphism (SNP) detection, sequencing and mutation/SNP genotyping for identification of sequence variants on an automated 24-, 96- or 192-capillary array instrument. In the first mode, multiple DNA samples consisting of homoduplexes and heteroduplexes are separated by CE, during which a temperature gradient is applied that covers all possible temperatures of 50% melting equilibrium (Tms) for the samples. The differences in Tms result in separation of homoduplexes from heteroduplexes, thereby identifying the presence of DNA variants. The sequencing mode is then used to determine the exact location of the mutation/SNPs in the DNA variants. The first two modes allow the rapid identification of variants from the screening of a large number of samples. Only the variants need to be sequenced. The third mode utilizes multiplexed single-base extensions (SBEs) to survey mutations and SNPs at the known sites of DNA sequence. The TGCE approach combined with sequencing and SBE is fast and cost-effective for high-throughput mutation/SNP detection.  相似文献   

16.
17.
The significant demands for single nucleotide polymorphism detection and genotyping assays have grown. Most common assays are based on the recognition of the target sequence by the hybridization with its specific probe having the complementary sequence of the target. Herein, a simple, label‐free, and economical non‐hybridization assay was developed for single nucleotide polymorphism detection and genotyping, based on the direct discrimination of single base mutation by simple capillary electrophoresis separation for single‐stranded DNA in an acidic electrophoretic buffer solution containing urea. Capillary electrophoresis separation of single‐base sequential isomers of DNA was achieved due to charge differences resulting from the different protonation properties of the DNA bases. Single nucleotide polymorphism detection and genotyping were achieved by discriminating the electropherogram pattern change, that is, peak number in the electropherogram, obtained by the proposed method. The successful practical application of the proposed method was demonstrated through single nucleotide polymorphism detection and genotyping on a known gene region of 84‐mer, in which guanine to adenine single‐base mutation is commonly observed, using a human hair sample in combination with genomic DNA extraction, polymerase chain reaction amplification, DNA purification from polymerase chain reaction products, and capillary electrophoresis separation.  相似文献   

18.
To elucidate the impact of matrix chemical and physical properties on DNA sequencing separations by capillary electrophoresis (CE), we have synthesized, characterized and tested a controlled set of different polymer formulations for this application. Homopolymers of acrylamide and N,N-dimethylacrylamide (DMA) and copolymers of DMA and N,N-diethylacrylamide (DEA) were synthesized by free radical polymerization and purified. Polymer molar mass distributions were characterized by tandem gel permeation chromatography - laser light scattering. Polymers with different chemical compositions and similar molar mass distributions were selected and employed at the same concentration so that the variables of comparison between them were hydrophobicity and average coil size in aqueous solution. We find that the low-shear viscosities of 7% w/v polymer solutions decrease by orders of magnitude with increasing polymer hydrophobicity, while hydrophilic polymers exhibit more pronounced reductions in viscosity with increased shear. The performance of the different matrices for DNA sequencing was compared with the same sample under identical CE conditions. The longest read length was produced with linear polyacrylamide (LPA) while linear poly-N,N-dimethylacrylamide (PDMA) gave approximately 100 fewer readable bases. Read lengths with DMA/DEA copolymers were lower, and decreased with increasing DEA content. This study highlights the importance of polymer hydrophilicity for high-performance DNA sequencing matrices, through the formation of robust, highly-entangled polymer networks and the minimization of hydrophobic interactions between polymers and fluorescently-labeled DNA molecules. However, the results also show that more hydrophobic matrices offer much lower viscosities, enabling easier microchannel loading at low applied pressures.  相似文献   

19.
Timerbaev AR 《Electrophoresis》2004,25(23-24):4008-4031
This review as a sequel of three earlier similar reports gives a summary of the progress and significant methodological developments, starting from 2002, in the use of capillary electrophoresis (CE) for inorganic ion analysis. As substantiated by the illustrative number of relevant references, improvements in sensitivity achieved both in and outside a CE system, advances in manipulating the separation selectivity, novel hardware configurations, and system performance innovations are continually being reported over the review period. Specifically viewed are the recent advancements in elemental (bio)speciation analysis, which remains one of the most fertile areas of CE research, as well as in three recently booming research topics: contactless conductivity detection, separations on microchips, and transient isotachophoretic preconcentration. A state-of-the-art picture of technique's potentialities within the field of interest presented here demonstrates that CE has become recognized and is growing in acceptance as a reliable alternative to traditional analytical methods such as high-performance liquid chromatography (HPLC).  相似文献   

20.
Yang R  Shi R  Peng S  Zhou D  Liu H  Wang Y 《Electrophoresis》2008,29(7):1460-1466
We present cationized hydroxyethylcellulose (cat-HEC) synthesized in our laboratory as a novel physically adsorbed coating for CE. This capillary coating is simple and easy to obtain as it only requires flushing the capillary with polymer aqueous solution. A comparative study with and without polymers was performed. The adsorbed cat-HEC coating exhibited minimal interactions with basic proteins, providing efficient basic protein separations with excellent reproducibility. Under broad pHs, the amine groups are the main charged groups bringing about a global positive charge on the capillary wall. As a consequence, the cat-HEC coating produced an anodal EOF performance. A comparative study on the use of hydroxyethylcellulose (HEC) and cat-HEC as physically adsorbed coatings for CE are also presented. The separation efficiency and analysis reproducibility proved that the cat-HEC polymer was efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. The long-term stability of the cat-HEC coating in consecutive protein separation runs has demonstrated the suitability of the coating for high-throughput electrophoretic protein separations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏