首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Quantitation of urinary tetranor PGDM or tetranor PGEM (tPGDM and tPGEM) in the past was performed separately using off-line SPE LC-MS/MS methods. The manual SPE procedure is generally time-consuming and cost-ineffective. In addition, simultaneous quantitation of tPGDM and tPGEM is favorable yet very challenging because of the similar chemical structures and identical MRM transitions. This work describes the development and validation of a high-throughput online SPE-LC-MS/MS method, allowing simultaneous and high-throughput measurement of tPGDM and tPGEM in human urine. The reportable range of the assay was 0.2-40 ng/ml for tPGDM and 0.5-100 ng/ml for tPGEM. Intra- and inter-assay precision and accuracy determined using quality control samples were all within acceptable ranges (% CV and % Bias < 15%). Tetranor PGDM was stable under all tested conditions while tPGEM was stable at 4 °C and after three F/T cycles but not stable at room temperature for 24 h (recovery below 80%). The assay was applied to measure urinary tPGDM and tPGEM among healthy volunteers, smokers and COPD patients. Significantly higher urinary levels of both tPGDM and tPGEM were observed in COPD patients than those of non-smoking healthy volunteers. These results demonstrated that the high-throughput online SPE-LC-MS/MS assay provides sensitive, reproducible and accurate measurement of urinary tPGDM and tPGEM as biomarkers for assessing inflammatory diseases such as COPD.  相似文献   

2.
建立了同时检测水稻中6种内源性植物激素脱落酸( Abscisic acid,ABA)、吲哚-3-乙酸( Indole-3-acetic acid, IAA)、水杨酸( Salicylic acid,SA)、茉莉酸( Jasmonic acid,JA)、吲哚-3-丙酸( Indole-3-propionic acid, IPA)和吲哚-3-丁酸( Indole-3-butyric acid,IBA)的全自动在线固相萃取-液相色谱-串联质谱方法。植物样品经过甲醇提取,采用C18固相萃取柱富集净化,流动相将待测物洗脱至C18分析色谱柱进行分离,最终使用串联四极杆质谱进行检测。方法的线性范围为8~320μg/L,相关系数为R2≥0.99;方法的检出限(S/N=3)范围为0.1~0.8μg/kg;实际样品中方法回收率范围为71.2%~126%,RSD<13%。应用本方法快速、准确地检测了水稻幼穗中多种内源性植物激素的含量,并与目前植物学领域内常用的检测方法进行了比较。同时,本方法对水稻受伤叶片的内源植物激素含量变化进行了定量分析,其含量随受伤时间的变化趋势与其生物背景的实验结果相吻合。  相似文献   

3.
An automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) system was developed for the determination of macrolide antibiotics including erythromycin (ETM), roxithromycin (RTM), tylosin (TLS) and tilmicosin (TMC) in environmental water samples. A Capcell Pak MF Ph-1 column packed with restricted access material (RAM) was used as SPE column for the concentration of the analytes and clean-up of the sample. One milliliter water sample was injected into the conditioned SPE column and the matrix was washed out with 3 mL high purity water. By rotation of the switching valve, macrolides (MLs) were eluted in the back-flush mode and transferred to the analytical column by the chromatographic mobile phase. The matrix effect was evaluated by the directly injection LC-MS and on-line SPE-LC-MS methods. The limits of detection (LODs) and limits of quantification (LOQs) obtained are in the range of 2-6 and 7-20 ng L−1, respectively, which means that the proposed method is suitable for trace analysis of MLs at low level concentration. The intra- and inter-day precisions are in the range of 2.9-7.2% and 3.3-8.9%, respectively. In the three fortified levels (20, 200 and 2000 ng L−1), recoveries of MLs ranging from 86.5% to 98.3% are obtained.  相似文献   

4.
On-line solid phase extraction (SPE) coupled to liquid chromatography-mass spectrometry (LC-MS) offers an easy and fast strategy to analyze the organic contaminants in environmental samples with high sensitivity and selectivity. This paper described an in-house designed on-line SPE system and an on-line SPE-LC-MS method for the determination of pesticides at trace levels in water samples. The system was assembled from an eight-position valve, a piston pump, a six-port valve and a C18 SPE column, and significantly reduced analysis time by achieving full automation. Moreover, the use of a large enrichment volume (50?mL) significantly enhanced method sensitivity. Using this on-line SPE system, an on-line SPE-LC-MS method was developed for the determination of nine pesticides at trace levels in lake water and seawater sample. Under optimized conditions, method detection limits (MDLs) were 1.00–10.0?ng?L?1.  相似文献   

5.
陈静  刘召金  戴振宇  安保超  许群  张祥民 《色谱》2013,31(9):894-897
建立了一个简单、快速、有效的适用于质谱或液相色谱-质谱联用的在线固相萃取(SPE)高通量除盐方法。方法分为单柱和双柱模式,借助于包含双梯度泵(上样泵/分析泵)、自动进样器和配有十通切换阀的柱温箱的高效液相色谱系统,完成样品的自动化在线除盐。单柱模式通过上样泵实现在SPE柱上进样和除盐,被分析物则保留在SPE柱上;除盐完成后,通过阀切换利用分析泵洗脱富集在SPE柱上的被分析物。双柱模式则在单柱模式基础上增加了1根SPE柱,在色谱管理软件控制下2根SPE柱轮流工作,高效率完成样品的在线除盐。该方法在结合质谱分析蛋白质、多肽等领域具有较好的应用前景。  相似文献   

6.
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L−1.This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L−1).  相似文献   

7.
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC–MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122 ng L−1 while the limit of quantification ranged from 90 to 370 ng L−1. Calibration curves in the wastewater matrix showed good linearity (R2 ≥ 0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision.  相似文献   

8.
This article describes the use of monolithic material as extraction support in simultaneous LC-MS/MS quantitation of a highly hydrophobic pharmaceutical compound and its hydroxylated metabolite in urinary matrix. DMSO was added to urine samples to aid the solubilization of analytes during storage and transfer. Samples were then diluted and injected onto an online extraction system for high-throughput analysis in an automated fashion. A linear range of 1.03-103 ng/mL was validated for the parent compound and 7.02-1400 ng/mL for the metabolite. The accuracy (%bias) at the lower LOQ (LLOQ) for the parent compound was -2.9% and the precision (%CV) at the LLOQ was 5.4%, while the accuracy at LLOQ for the metabolite was 6.3% and the precision at LLOQ was 5.5%. The results show that quantitative LC-MS/MS analysis by online extraction using the monolithic support is reproducible, sensitive, and accurate enough to satisfy bioanalytical testing requirements in a good laboratory practice (GLP) regulated environment. Monolithic phase based online extraction provided efficient sample cleanup, which was evidenced in matrix effect testing against multiple lots of urinary matrix. The method described within can be a generic approach for quantitative analysis of analytes with poor solubility in aqueous matrix.  相似文献   

9.
An effective analytical protocol using graphene‐based SPE coupled with HPLC‐MS/MS for determination of chloramphenicol (CAP) in aquatic products has been developed. In the present work, graphene was evaluated as SPE sorbents for the analytes enrichment and clean up. The target analytes were quantified by a triple‐quadrupole linear ion trap MS in multiple‐reaction monitoring mode. In addition, the proposed method was validated according to Commission Decision 2002/657/EC. The calibration curve was linear over the range of 0.5–100 ng/mL. The mean values of RSD of intra‐ and interday ranging from 1.48 to 4.29% and from 3.25 to 7.42% were obtained, respectively. In the three fortified levels, the recoveries of CAP ranging from 92.3 to 103.4% with RSDs ≤ 5.58% were obtained. The proposed method has been successfully applied to the analysis of CAP in several aquatic product samples, indicating that graphene was a potential SPE sorbent for the enrichment of trace residues in food samples.  相似文献   

10.
An ion exchange solid phase extraction (SPE) strategy is developed for application with liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) for characterization of central carbon metabolites involved in methane assimilation and adjacent pathways in natural mixtures. For this purpose, short-time microcosm samples were obtained from lake sediment known to consume methane. Three SPE procedures were developed for the recovery of 51 targeted metabolites from five compound classes (amino acids, carboxylic acids, sugar phosphates, nucleotides and acyl-CoAs). The three SPE procedures employed were mixed mode (i) strong cation exchange, (ii) strong anion exchange and (iii) weak anion exchange. By spiking stable isotopic labeled standards, validation of the SPE procedures for the sediment extracts demonstrated that a 3 cm(3), 60 mg SPE sorbent bed provided effective loading capacity for targeted metabolites with an analytical variation of 16% RSD. We readily analyzed 32 of the targeted 51 metabolites using LC-MS/MS after sediment sample extraction, cleanup and pre-concentration. The remaining 19 targeted metabolites were either at, or below, the limit of detection. The current approach provides a good workflow for absolute quantification of intermediates in C(1)-carbon metabolism in natural microbial communities.  相似文献   

11.
We optimised the simultaneous analysis of four analytes, namely three anti-influenza drugs (oseltamivir (OS), zanamivir (ZAN) and amantadine (AMN)) and one metabolite of OS (oseltamivir carboxylate (OC)), in sewage treatment plant (STP) influent and effluent by verifying the types and conditions of solid phase extraction (SPE) appropriate for LC-MS/MS analysis. In summary, these target analytes were extracted from aqueous samples (30–50 mL) by using strong cation-exchange SPE cartridges (500 mg adsorbent) under acidic conditions (pH 3–4). After washing of the cartridges with acidified water (pH 3.0, 3 mL) and methanol (3 mL), the analytes were eluted with a mixed solvent (2 mL) of 10% (v/v) triethylamine in a 1:1 (v/v) mixture of acetone and water. Application of this technique to the target compounds should yield a comprehensive understanding of the occurrence and fate of anti-influenza drugs in the water environment.  相似文献   

12.
徐小民  张京顺  蔡增轩  孟真  黄百芬  陈苘 《色谱》2020,38(11):1281-1287
建立了在线固相萃取-液相色谱-串联质谱(online SPE-LC-MS/MS)测定蘑菇中毒患者尿液中痕量α -鹅膏毒肽的分析方法。样品经甲酸酸化的乙腈-甲醇(5:1,v/v)沉淀蛋白质,反相液液微萃取去除样品提取液中的有机溶剂,毒素经ODS微柱(5 mm×2.1 mm,5 μm)在线SPE净化,XBridgeTM BEH C18 色谱柱(150 mm×3.0 mm,2.5 μm)分离,MS/MS测定。采用基于定量环的快速阀切换技术作为在线SPE和LC-MS/MS模块的接口,使得两个分离模块互相独立,无论是流动相还是压力,都不会互相干扰,保证了系统的稳定性;在线系统的精准净化,有效消除了后续质谱检测的基质效应,确保了尿液中痕量水平α -鹅膏毒肽的定性定量检测。尿液中α -鹅膏毒肽在0.1~50 μg/L范围内线性关系良好,相关系数(r 2 )为0.9983;检出限(LOD)为0.03 μg/L;α -鹅膏毒肽的加标(0.1、2.0和20 μg/L)平均回收率为84.3%~91.7%,相对标准偏差(RSD)为3.8%~7.2%。体内鹅膏毒肽代谢迅速,生物基质中痕量水平毒素的检测是其中毒实验室鉴定的主要难题,通过实际样品检测,证明该法操作简单,准确、灵敏;溶剂沉淀蛋白质和反相液液微萃取去除有机相和脂溶性基质的简单操作,可以作为水溶性毒素在线SPE-LC-MS/MS检测时快速且有效的配套前处理方法;基于在线SPE精准净化技术,可以实现尿液中α -鹅膏毒肽的高灵敏度测定(LOD为0.03 μg/L),解决了中毒时患者体内痕量水平α -鹅膏毒肽定性确证的难题,部分患者α -鹅膏毒肽中毒实验室鉴定的时间可以扩展到90 h以上;同时,痕量水平的定量检测技术,可以为中毒后迅速代谢的α -鹅膏毒肽在体内的剂量反应关系研究提供可靠的技术支撑。  相似文献   

13.
An environmentally friendly method for extracting sulfonamides(SAs) residues from animal feed was described and applied. The method used online microwave-assisted steam extraction coupled with solid phase extraction(MASE-SPE), which was followed by the analysis using high performance liquid chromatography-mass spectrometry(HPLC-MS/MS). The SAs residues were extracted successively with water steam under microwave irradiation, and thus directly introduced into an SPE column containing cation-exchange resin. The SAs were then eluted with methanol-ammonia(90:10, volume ratio) from the SPE column and followed by HPLC-MS/MS. The limits of detection(LODs) for the analytes ranged from 0.24 ng/g to 0.49 ng/g. The limits of quantification(LOQs) ranged from 0.82 ng/g to 1.63 ng/g. Average recoveries of SAs were 76.3%-92.1%. The developed method was a reliable and environmentally friendly alternative to previous methods with respect to time, solvent and labor consumption for the analysis of SAs in animal foodstuffs.  相似文献   

14.
Endosulfan, the last remaining organochlorine pesticide, has been the subject of a number of international regulations and restriction/banning action plans worldwide. Occurrence of endosulfan residues in South Florida environments has been widely described in the literature for more than two decades. This work describes a selective, sensitive, and fast online solid-phase extraction (SPE) method coupled with liquid chromatography separation and tandem mass spectrometry (LC-MS/MS) for the determination of endosulfan isomers and endosulfan sulfate in water samples at low part per trillion levels with very little sample preparation. A negative atmospheric pressure chemical ionization source was carefully optimized to produce reproducible spectra of the target compounds with no adduct ion formation. Selected reaction monitoring transitions were monitored and quantitation was performed against a per-deuterated internal standard β-endosulfan (d4). The automated online SPE clean-up was performed using only 20 mL of untreated water sample prior to LC-MS/MS analysis. The method was capable of separating and quantifying endosulfan within a 24-min run using acetonitrile and water as mobile phases and presenting statistically calculated method detection limits of 3, 10, and 7 ng/L for endosulfan sulfate, α-endosulfan, and β-endosulfan, respectively. In addition, a QuEChERS method was successfully developed and applied for endosulfan determination in sediments/soils, floating and submerged algal mats, and small fish. Minimal matrix effects were observed in all matrices analyzed and recoveries for all analytes ranged from 50–144 %. The developed methodology was applied to monitor the occurrence and to assess the potential transport of endosulfan in the Loveland Slough watershed, an area adjacent to Everglades National Park showing long-term contamination with endosulfans.  相似文献   

15.
郭坚  杨新磊  叶明立 《分析化学》2011,39(8):1256-1260
建立了全自动化在线固相萃取-高效液相色谱法快速、准确测定水体中3种痕量微囊藻毒素的新方法.样品用自动进样器连续注入固相萃取小柱完成富集后,通过双梯度高效液相系统中的一个泵(上样泵)实现净化,再通过阀切换将固相萃取小柱切换至分析流路中,用另一个泵(分析泵)将待测物冲洗至分析柱进行测定.方法使用Acclaim PA柱芯(1...  相似文献   

16.
Proanthocyanidins, flavonoids exhibiting cardiovascular protection, constitute a major fraction of the flavonoid ingested in the human diet. Although they are poorly absorbed, they are metabolized by the intestinal microbiota into various phenolic acids. An analytical method, based on an optimized 96-well plate solid-phase extraction (SPE) procedure and liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) for the analysis of 19 phenolic microbial metabolites and monomeric and dimeric flavanols in urine samples, was developed and validated. Human urine samples were obtained before and after ingestion of an acute consumption of 40 g of soluble cocoa powder and rat urines before and after the prolonged administration (2 weeks) of different diets composed of natural cocoa powder. The mean recovery of analytes using the new SPE-LC-MS/MS method ranged from 87% to 109%. Accuracy ranged from 87.5% to 113.8%, and precision met acceptance criteria (<15% relative standard deviation). Procyanidin B2 has been detected and quantified for the first time in human and rat urine after cocoa consumption. Changes in human and rat urinary levels of microbial phenolic acids and flavanols were in the range of 0.001–59.43 nmol/mg creatinine and of 0.004–181.56 nmol/mg creatinine, respectively. Major advantages of the method developed include reduction of laboratory work in the sample preparation step by the use of 96-well SPE plates and the sensitive measurement of a large number of metabolites in a very short run time, which makes it ideal for use in epidemiological studies. a INGENIO-CONSOLIDER Program, Fun-c-food CSD2007-063 b CIBER 06003 Physiopathology of Obesity and Nutrition (CIBEROBN), and RETICS RD06/0045/0003, Instituto de Salud Carlos III  相似文献   

17.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

18.
何建丽  彭涛  谢洁  胡雪艳  常巧英  陈辉  范春林  李存 《色谱》2016,34(7):708-714
建立了使用固相萃取-液相色谱-串联质谱(SPE-LC-MS/MS)同时检测食品包装材料中16种全氟烷基类化合物(PFAS)的方法。分别对样品前处理方法、质谱条件等进行了比较和优化,样品用甲醇超声提取,经Oasis WAX固相萃取小柱净化后,用Atlantis T3 C18色谱柱分离,以乙腈和5 mmol/L乙酸铵溶液为流动相进行梯度洗脱,多反应监测(MRM)负离子模式扫描,同位素内标法和外标法结合定量。16种PFAS在0.5~20.0 μg/L范围内线性关系良好,相关系数(r2)均大于0.99。加标回收率为68.6%~109.2%,RSD为2.5%~18.1%(n=6)。检出限为0.2~0.5 μg/kg,定量限为0.5~1.0 μg/kg。该方法简便、快速、准确,可用于食品包装材料样品中PFAS的检测。  相似文献   

19.
An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%  相似文献   

20.
Microdialysis (MD) is an in vivo sampling technique used to investigate biochemical events in the extracellular fluid of animal and human tissues. MD produces protein- and cell-free, aqueous samples which can be analyzed without further sample clean-up. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is a sensitive and selective analysis technique which is suitable to quantify low concentrated target analytes in microdialysates. This paper reviews the LC-MS/MS methods which are described for the quantification of endogenous molecules, such as neurotransmitters and peptides, and of exogenous molecules, such as drugs, in microdialysates. Since miniaturization of the LC-MS/MS methods is the key to obtain maximal sensitivity of the analytical technique, this feature is discussed in the paper. In addition, critical issues related to the quantification of low concentrated molecules in microdialysates are described such as the presence of matrix effects, the low MD efficiency and the sticking of, for instance, neuropeptides.  相似文献   