首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Poly(vinyl chloride) polymeric membranes plasticized with o-NPOE (o-nitrophenyl octyl ether) or DOS (dibutyl sebacate) and containing Zr(IV)-octaethyl(OEP)- or Zr(IV)-tetraphenylporphyrins (TPP) along with lipophilic cationic additives (tridodecylmethylammonium chloride; TDMACl) are examined potentiometrically and optically with respect to their response toward fluoride. It is shown that these zirconium porphyrins can function as neutral anion carriers within the organic membranes of the electrodes. Spectrophotometric measurements of thin polymeric films indicate that the presence of lipophilic cationic sites in the form of TDMA+ and use of lower dielectric constant plasticizer (DOS) prevents formation of metalloporphyrin dimers in the organic polymer phase, which have been observed previously in polymeric membranes formulated with the same Zr(IV) porphyrins but with lipophilic anion site additives. By preventing dimer formation, rapid and Nernstian potentiometric response of the corresponding membrane electrodes toward fluoride ion is observed. Indeed, electrodes prepared with PVC/DOS membranes containing Zr(IV)-OEP and 15 mol% of TDMACl (relative to the ionophore) exhibit fast (t95<15 s) and reversible response toward fluoride. The slope of calibration plots are near-Nernstian (−59.9 mV per decade). Such electrodes display the following selectivity pattern: ClO4>SCN>F>NO3>Br>Cl, which differs significantly from the classical Hofmeister series, with greatly enhanced potentiometric selectivity toward fluoride. The data presented herein, coupled with results from a previous study, confirm that Zr(IV) porphyrins can serve as either charged or neutral type anion carriers with respect to their enhanced interactions with fluoride when used as ionophores to prepare liquid-polymeric membrane electrodes, and that the nature of membrane additives and plasticizer dictates the response mechanism at play for given membrane formulations.  相似文献   

2.
The feasibility of using Tecoflex polyurethane as a polymeric matrix for fluoride-selective membranes doped with Zr(IV)-octaethyl-(OEP) or Zr(IV)-tetraphenylporphyrins (TPP) is examined. Membranes containing cationic or anionic additives were prepared, with ionophore working according to neutral or charged carrier mechanism, respectively. Results are compared to those found previously using conventional poly(vinyl chloride) (PVC) as the membrane matrix. It was found that this polymer does not affect significantly the properties of these porphyrins, compared to poly(vinyl chloride) matrix. A dimer-monomer equilibrium determined recently to occur for Zr(IV)-porphyrins in PVC/o-NPOE membranes containing lipophilic anionic additives is also observed to occur (via UV-vis spectrophotometry) in the PU matrix. However, the equilibrium constants for dimer-monomer reactions appear to be lower in PU membranes compared to PVC films, as determined from the degree of super-Nernstian responses towards fluoride as well as the anion concentration ranges required to break the dimer as determined spectroscopically. Due to reduced dimerization of Zr(IV)[OEP]Cl2 it was possible to obtain electrodes with PU/o-NPOE/KTFPB membranes exhibiting only slightly super-Nernstian (−64.6 mV/dec) response towards fluoride and response time (t95 < 120 s) faster than observed for PVC-based membranes. Good working parameters were also obtained for this metalloporphyrin in PU membrane that forces neutral carrier mechanism (PU/DOS/TDMACl): F calibration slope −58.3 mV/dec and response time t95 < 12 s. Tested membranes were subsequently applied for construction of miniaturized silicon-based sensors. Better fluoride selectivity was observed for sensors with Zr(IV)[OEP]Cl2/PU/o-NPOE/KTFPB membranes (: ClO4 0.7; Br −1.9; NO3 −1.9; Cl −3.1), compared to Zr(IV)[OEP]Cl2/PU/DOS/TDMACl matrix (: ClO4 −0.8; Br −1.3; NO3 −1.5; Cl −2.1). However, latter composition was chosen to be better for flow measurement mode, as dimer formation can be totally prevented within this membrane. Sensors with Zr(IV)[OEP]Cl2/PU/DOS/TDMACl maintained their characteristics at least for 2 months.  相似文献   

3.
Al(III)- and Zr(IV)-salophens of novel structures were tested as anion-selective ionophores. It was shown that these compounds are highly selective to fluoride and give selectivity greatly deviating from classical Hofmeister pattern, when doped into the polymeric membrane of ion-selective electrode (ISE). The following selectivity sequence has been recorded for both ionophores: F > ClO4 > SCN > NO3 ≈ Br ≈ Cl. The results of potentiometric and spectrophotometric measurements allow to conclude that the nature and structure of salophen ligands influence stability of ISE working parameters. An increase in salophen ligands lipophilicity results in prolongation of the ISE lifetime, most likely due to slower ionophore decomposition caused by the hydrolysis of imine bonds in salophen structure. Ion-selective electrodes (ISEs) with the most successful Al(III)-salophen exhibited a stable, fast and near-Nernstian fluoride response and a functional lifetime near 3 weeks and selectivity coefficients with as follows: −2.8 (Y = Br), −2.7 (Cl), −2.8 (NO3), −1.5 (SCN), −1.3 (ClO4), which is better than for other ones based on Zr(IV)- and Al(III)-salophens and salens described to date.  相似文献   

4.
In this work, complexes of Zr(IV) and Al(III) cations with 2,7,12,17-tetra-tert-butyl-5,10,15,20-tetraazaporphine (TAP) were tested as ionophores in plasticized PVC membranes of ion-selective electrodes. It was found that both tested ionophores show enhanced affinity towards fluoride anion. High fluoride selectivity was observed in the presence of anionic or cationic additives in the membrane, which indicates that proposed compounds work according to charged or neutral carrier mechanism, depending on membrane composition and pretreatment.tert-Butyl substituents, present in the structure of tested compounds, were supposed to prevent formation of ionophore dimers within the membrane phase. This process was found to be responsible for some unfavorable potentiometric properties of electrodes based on complexes of Zr(IV) and Al(III) cations with porphyrins (compounds closely related to tetra-tert-butyl-5,10,15,20-tetraazaporphine). As it was shown using spectrophotometrical measurements, Al(III)-TAP was not susceptible to dimerization, while dimer formation was observed for Zr(IV)-TAP. In full agreement with these observations, electrodes with membranes containing Al(III)-TAP responded in near-Nernstian and fast manner towards fluoride anion, while the employment of Zr(IV)-TAP as ionophore resulted in super-Nernstian and sluggish response. Plasticized PVC membranes doped with Al(III)-TAP and 20 mol% of lipophilic anionic additives shown remarkable F selectivity, with selectivity coefficients, , as follows: −4.4 (YBr), −4.3 (Cl), −4.2 (NO3), −3.6 (SCN), −2.9 (ClO4).  相似文献   

5.
《Electroanalysis》2006,18(6):551-557
Aluminum(III) porphyrins are examined as potential fluoride selective ionophores in polymeric membrane type ion‐selective electrodes. Membranes formulated with Al(III) tetraphenyl (TPP) or octaethyl (OEP) porphyrins are shown to exhibit enhanced potentiometric selectivity for fluoride over more lipophilic anions, including perchlorate and thiocyanate. However, such membrane electrodes display undesirable super‐Nernstian behavior, with concomitant slow response and recovery times. By employing a sterically hindered Al(III) picket fence porphyrin (PFP) complex as the membrane active species, fully reversible and Nernstian response toward fluoride is achieved. This finding suggests that the super‐Nernstian behavior observed with the nonpicket fence metalloporphyrins is due to the formation of aggregate porphyrin species (likely dimers) within the membrane phase. The steric hindrance of the PFP ligand structure eliminates such chemistry, thus leading to theoretical response slopes toward fluoride. Addition of lipophilic anionic sites into the organic membranes enhances response and selectivity, indicating that the Al(III) porphyrin ionophores function as charged carrier type ionophores. Optimized membranes formulated with Al(III)‐PFP in an o‐nitrophenyloctyl ether plasticized PVC film exhibit fast response to fluoride down to 40 μM, with very high selectivity over SCN?, ClO4?, Cl?, Br? and NO3? (kpot<10?3 for all anions tested). With further refinements in the membrane chemistry, it is anticipated that Al(III) porphyrin‐based membrane electrodes can exhibit potentiometric fluoride response and selectivity that approaches that of the classical solid‐state LaF3 crystal‐based fluoride sensor.  相似文献   

6.
《Electroanalysis》2005,17(21):1945-1951
Tin(IV) porphyrins derivatives were used as ionophores for phthalate selective electrodes preparation. The influence of ionophore structure and membrane composition (amount of incorporated ionic sites) on the electrode response, selectivity and long‐term stability were studied. Poly(vinyl chloride) polymeric membranes plasticized with o‐NPOE (o‐nitrophenyloctylether) and containing Sn(IV)‐tetraphenylporphyrin (TPP) dichloride (Sn(IV)[TPP]Cl2) or Sn(IV)‐octaethylporphyrin (OEP) dichloride (Sn(IV)[OEP]Cl2), and in some cases incorporating lipophilic cationic (tetraocthylammonium bromide ‐ TOABr) and anionic (sodium tetraphenylborate – NaTPB and potassium tetrakis[3,5‐bis(trifluoromethyl)phenyl]borate‐KTFPB) additives, were prepared and their potentiometric characteristics compared. Both ionophores are shown to operate via a neutral mechanism, and the addition of 10 mol % of lipophilic quaternary ammonium salt derivative to the membrane is required to achieve optimal electrode performance. The potentiometric units prepared, with Sn(IV)[TPP]Cl2 (Type A) or Sn(IV)[OEP]Cl2 (Type B) without additives, presented a slope of ?52.8 mV dec?1 and ?58.8 mV dec?1 and LLLR of 9.9×10?5 mol L?1 and 9.9×10?6 mol L?1, respectively. The units prepared using the same metalloporphyrins and incorporating 10% mol TOABr presented a slope of ?55.0 mV dec?1 and ?57.8 mV dec?1 and LLLR of 5.0×10?7 mol L?1 and 3.0×10?7 mol L?1. Their analytical usefulness was assessed by potentiometric determinations of phthalate in water and industrial products providing results that presented recoveries of about 100%.  相似文献   

7.
Ion-selective properties were established for membrane electrodes prepared by using organotin compounds of type (LCNRSnF2)n, (R = n-Bu (I), = Ph (II)) and (LCNSnF3)n (III) (LCN = C6H4(CH2NMe2)-2). Electrodes formulated with the optimized membranes containing the organotin compounds I-III as ionophores and sodium tetraphenylborate (10-30%) exhibited high selectivity for fluoride over other anions. An electrode prepared with ionophore II using dibutyl phthalate as the plasticizer and 15% sodium tetraphenylborate (NaTPB) as anion additive, possesses the best potentiometric response characteristics. It shows a detection limit of 7.9 × 10−7 M with a slope of 62.7 mV decade−1 of activity in buffer solutions of pH 5.5. The interference from other anions is suppressed under this optimized measurement conditions. An entirely non-Hofmeister selectivity sequence (F > CH3COO > Cl > I ∼ Br >ClO4 > NO2 > NO3 > SCN) with remarkable preference towards fluoride is obtained. The influence on the electrode performances by anion additive was studied, and the possible response mechanism was investigated by UV-vis spectra. The electrode has been used for direct determination of fluoride in drinking mineral water with satisfactory results.  相似文献   

8.
Novel aluminum(III)- and zirconium(IV)-tetraphenylporhyrin (TPP) derivatives are examined as fluoride-selective ionophores for preparing polymer membrane-based ion-selective electrodes (ISEs). The influence of t-butyl- or dichloro-phenyl ring substituents as well as the nature of the metal ion center (Al(III) versus Zr(IV)) on the anion complexation constants of TPP derivative ionophores are reported. The anion binding stability constants of the ionophores are characterized by the so-called “sandwich membrane” method. All of the metalloporphyrins examined form their strongest anion complexes with fluoride. The influence of plasticizer as well as the type of lipophilic ionic site additive and their amounts in the sensing membrane are discussed. It is shown that membrane electrodes formulated with the metalloporphyrin derivatives and appropriate anionic or cationic additives exhibit enhanced potentiometric response toward fluoride over all other anions tested. Since selectivity toward fluoride is enhanced in the presence of both anionic and cationic additives, the metalloporphyrins can function as either charged or neutral carriers within the organic membrane phase. In contrast to previously reported fluoride-selective polymeric membrane electrodes based on metalloporphyrins, nernstian or near-nernstian (−51.2 to −60.1 mV decade−1) as well as rapid (t < 80 s) and fully reversible potentiometric fluoride responses are observed. Moreover, use of aluminum(III)-t-butyltetraphenylporphyrin as the ionophore provides fluoride sensors with prolonged (7 months) functional lifetime.  相似文献   

9.
Selectivity coefficients of liquid-membrane electrodes for common inorganic anions were measured in electrodes containing tris(l,10-phenanthroline)iron(II), tris(4,7-diphenyl-1,10-phenanthroline)iron(II) or tetraheptylammonium ion in nitrobenzene, and tris(4,7-diphenyl-1,10-phenanthroline)iron(II) ion in nitrobenzene, chloroform or n-amyl alcohol as the liquid membrane. With the exception of the amyl alcohol electrode, selectivity coefficients were relatively independent of membrane composition and followed a common sequence of decreasing selectivity: PF6?> ClO4?>SCN?~I?~BF4?>NO3?>Br?>Cl?. This sequence parallels the order of increasing anion hydration energy, suggesting that aqueous phase solvation energies play a predominant role in determining electrode selectivity for these ions. Time-dependent behavior of liquid-membrane electrodes on transfer between solutions containing different ions also is described. Instantaneous e.m.f. readings were used to determine selectivity coefficients.  相似文献   

10.
《Electroanalysis》2005,17(11):1003-1007
A novel PVC membrane ion‐selective electrode based on tribenzyltin(IV) dithiocarbamate [Sn(IV)–TBDTB] as neutral carrier was developed for thiocyanate (SCN?) determination. The electrode exhibits a near‐Nernstian response for SCN? with a slope of 62.8±2.0 mV per decade over a wide concentration range 1.0×10?1–2.0×10?6 mol L?1 and a detection limit of 1.0×10?6 mol L?1 in MES–NaOH buffer, pH 6.0, at 25 °C. The electrode prepared with 1.5 wt.% Sn(IV)–TBDTB, 32.5 wt.% PVC and 66.0 wt.% 2‐nitrophenyloctyl ether (o‐NPOE) shows optimal response characteristics. Anti‐Hofmeister selectivity sequence for a series of anions shown by the electrode was as follows: SCN?>Sal?>I?>ClO >phCOO?>CH3COO?>Br?>Cl?>NO >NO >Citrate>SO42?. The useful pH range for the electrode was found to be 3–7 with a response time 30–40 s. The electrode has been used for direct determination of thiocyanate in wastewater with satisfactory results.  相似文献   

11.
《Analytical letters》2012,45(5):890-901
Abstract

A highly selective polyvinyl chloride (PVC) membrane electrode, based on N,N′‐(aminoethyl)ethylenediamide bis(2‐benzoideneimine) binuclear copper(II) complex [Cu(II)‐AEBB] as neutral carrier, was prepared for thiocyanate (SCN?) determination, which displays an anti‐Hofmeister selectivity sequence for a series of anions in the following order: SCN?>ClO4 ?>Sal? > I?>NO3 ?>Br?> Cl?>NO2 ?>SO3 2?>F?>H2PO4 ?>SO4 2?. The electrode exhibited near‐Nernst response for SCN? with a slope of –59.0 mV/decade over a wide concentration range (8.5×10?7~6.8×10?1 mol/L) with a detection limit of –5.0×10?7 mol/L in pH 5.0 phosphate buffer solution at 25°C. Alternating current (AC) impedance and equivalent circuits were used to investigate the thiocyanate response mechanism of the membrane doped with [Cu(II)‐AEBB].  相似文献   

12.
The synthesis and characterization of a new tetra (triphenylphosphonium) p-tert-butylcalix[4]arene 2 is presented. Its interactions with anions were studied by 1H and 31P NMR and UV absorption spectrophotometry, showing the biggest interaction with ClO4 , I and SCN. Anion selectivity in ion-selective PVC-membrane electrodes (ISEs) plasticized with o-NPOE containing ionophore 2 was also investigated. Compound 2 shows a potentiometric response for various anions with the following selectivity pattern: ClO4 > SCN > I > Cr2O7 2 ?  > NO3 > Br > Cl.  相似文献   

13.
The iron(III) and cobalt(III) complexes of 2,3,7,8,12,13,17,18-octakis(benzylthio)-5,10,15,20-tetraazaporphyrin, (OBTAP) were synthesized and incorporated into PVC matrix as ionophores to fabricate anion selective membrane electrodes that exhibit selective potentiometric response to azide and nitrite ions, respectively. The membrane of [Fe(OBTAP)]+ (III) with a composition of 6:190:200 (III:DBP:PVC) (w/w), and of [Co(OBTAP)]+ (IV) with a composition of 10:148:200 (IV:DOP:PVC) (w/w), i.e. 1a and 2b, respectively (where DBP:dibutylphthalate and DOP=dioctylphthalate) gave the best performance. The membrane 1a showed a slope of 29.2±0.2 mV per decade of activity for N3 in the working concentration range of 8.9×10−6 to 1.0×10−1 M. The membrane 2b showed a slope of 30.0±0.2 mV per decade of activity for NO2 in the working concentration range of 1.1×10−5 to 1.0×10−1 M. The membranes worked satisfactorily in the pH range of 4.3-10.5 (1a) and 2.8-6.4 (2b) and had fast response time of 12±2 and 13±2 s, respectively. Electrodes exhibited a high degree of selectivity for N3 and NO2, respectively, over several other monovalent and bivalent anions. Only SCN and S2− (at >1.0×10−4 M) cause moderate interference for electrode 1a and Cl and S2− (at >1.0×10−5 M) for electrode 2b. They gave reproducible results with the relative standard deviation in the observed values of potentials (σ) of 1.96 and 1.80 mV for electrodes 1a and 2b, respectively, from the least-squares fit line. The 90% confidence limit lies within ±0.2 mV per decade of activity. Reproducible results were obtained over a period of 5 months. Their performance in non-aqueous solvent mixtures having up to 50% (v/v) methanol, ethanol and acetone were evaluated and were found satisfactory. The proposed sensors are superior in terms of detection limit and response time in comparison to the reported ones.  相似文献   

14.
The feasibility of a newly synthesized Rh(III) complex, Rh[(trpy)(bpy)Cl](PF6)2, as a novel ionophore for the preparation of anion-selective polymeric membrane electrodes was tested. The ionophore exhibited anti-Hofmeister behavior with enhanced potentiometric selectivity toward thiocyanate ion compared to other anions. The influence of some experimental parameters such as membrane composition, nature and amount of plasticizer and additive and concentration of internal solution on the potential response of the SCN sensor were investigated. The electrode exhibits a Nernstian response for SCN over a wide concentration range (1.0 × 10−5 to 1.0 × 10−1 M) with a slope −58.7 ± 0.5 mV per decade and a detection limit of 4.0 × 10−6 M (0.23 ppm). It could be used in a pH range of 3.0-8.0 and has a fast response time of about 15 s. The proposed sensor was used for the determination of thiocyanate ions in real samples such as urine and saliva of smokers and nonsmokers and, as an indicator electrode, in potentiometric titrations of SCN ion.  相似文献   

15.
The new ligand 7-methyl-7,13-di-octyl-1,4,10-trioxa-13-aza-7-azonia-cyclopentadecane (L1) has been designed, synthesised and used as ionophore in the development ion-selective electrodes for anionic surfactants. Different PVC-membrane anionic-surfactants-selective electrodes were prepared by using L1 as ionophore and bis(2-ethylhexyl)sebacate (BEHS), dibutyl phthalate (DBP) and nitrophenyl octyl ether (NPOE) as plasticizers. The PVC-membrane electrode containing L1 and NPOE (electrode E1) showed a Nernstian response to lauryl sulfate with a slope of −59.5 mV per decade in a range of concentrations from 1.3 × 10−6 to 6.8 × 10−3 M and a detection limit of 6.0 × 10−7 M. The electrode E1 also showed a reasonable response to other alkyl sulfates and alkylbenzene sulfonates, whereas it does not respond to carboxylates and to cationic and non-ionic surfactants. A similar electrode to E1 but additionally containing the cationic additive n-octylammonium bromide was also prepared (electrode E2) and compared with the response of E1. Selectivity coefficients for different anions with respect to lauryl sulfate were determined by means of the fixed interference method considering lauryl sulfate as the principal anion and using a concentration of 1.0 × 10−2 mol dm−3 for the corresponding interfering anion. The selectivity sequence found for the electrode E1 was: LS > SCN > ClO4 > CH3COO > I > HCO3 > Br > NO3 > NO2 > Cl > IO3 > phosphate > SO32− > C2O42− > SO42−. Electrode E1 showed remarkably better selectivity coefficients than electrode E2.  相似文献   

16.
A new highly selective thiocyanate electrode based on N,N-bis-(furaldehyde)-1,2-phenylenediamine-dipicolyl copper(II) complex [Cu(II)-BFPD] as neutral carrier is described. The electrode has an anti-Hofmeister selectivity sequence: SCN>I>Sal>ClO4 >Br>NO2 >Cl>NO3 >SO4 2–>SO3 2–>H2PO4 and a near-Nernstian potential linear range for thiocyanate from 1.0×10–1 to 5.0×10–6 mol L–1 with a detection limit 2.0×10–6 mol L–1 and a slope of 57.5 mV decade–1 in pH 5.0 of phosphate buffer solution at 20 °C. The response mechanism is discussed on the basis of results from A.C. impedance measurement and UV spectroscopy. The anti-Hofmeister behavior of the electrode results from a direct interaction between the central metal and the analyte ion and a steric effect associated with the structure of the carrier. The electrode has the advantages of simplicity, fast response, fair stability and reproducibility, and low detection limit. The selectivity of electrodes based on [Cu(II)-BFPD] exceeds that of classical anion-sensitive membrane electrodes based on ion exchangers such as lipophilic quaternary ammonium or phosphonium salts. Application of the electrode for determination of thiocyanate in waste water samples from a laboratory and a gas factory, and in human urine samples, is reported. The results obtained were fair agreement with the results obtained by HPLC.  相似文献   

17.
The synthesis of a new compound, amide‐linked manganese diporphyrin xanthene (Mn2Cl2ADPX), and its application for preparation of thiocyanate selective electrodes was described. The electrode was prepared with a PVC membrane combining Mn2Cl2ADPX as an electro active material, 2‐nitrophenyl octyl ether (o‐NPOE) as a plasticizer in the percentage ratio of 3 : 65 : 32 (Mn2Cl2ADPX: o‐NPOE: PVC, w : w : w). The electrode exhibited linear response within the concentration range of 2.4×10?6 to 1.0×10?1 M SCN?, with a working pH range from 3.0 to 8.0 and a fast response time of less than 60 s. Several electroactive materials and solvent mediators have been compared and the experimental conditions were optimized. The Mn2Cl2ADPX based electrode shows obviously better response characteristics than that of monoporphyrin manganese in terms of working concentration range and slope. Selectivity coefficients for SCN? relative to a number of interfering ions were investigated. The electrode exhibits anti‐Hofmeister selectivity toward SCN? with respect to common coexisting anions. The electrode was applied to the determination of SCN? in body urine with satisfactory results.  相似文献   

18.
Solid-phase extraction (SPE) along with reversed-phase liquid chromatography (RP-LC) was used for the simultaneous determination of Zr(IV) and Hf(IV) by means of their ternary chelates with fluoride and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). The conditions of SPE sorption were examined in detail: type of SPE column, volume of the sample, volume of the eluent, concentrations of metal ions, fluoride salt, chromogenic reagent, organic phase, and pH. It was established that the sorption of Zr(IV) and Hf(IV), as their ternary chelates, on SPE Zorbax SPE C18 (EC) cartridge was the most efficient, when the sample containing metal ion (Zr(IV), Hf(IV), both, up to 2 μg), 5-Br-PADAP 1.5×10−4, NaF 7.5×10−5 mol l−1, methanol 40%, pH 4.5±1 was applied for the SPE sorption. The chelates were discarded from SPE cartridge using acetonitrile/water (99.75+0.25, v/v) eluent containing 3.8×10−4 mol l−1 sodium fluoride and subsequently separated by RP-LC method. The RP-LC separation of both chelates was optimized and Zorbax SB-C18 analytical LC column along with acetonitrile/water (65+35, v/v) eluent containing the 1.5×10−4 mol l−1 sodium fluoride was used. The established SPE/LC conditions allow Zr(IV) 0.08-2.0 μg and Hf(IV) 0.04-2.0 μg determination in a sample volume up to 150 ml. The detection limits, 0.03 μg Hf(IV) and 0.05 μg Zr(IV), were obtained. Recoveries, (94±2)% for Hf(IV) chelate and (106±2)% for Zr(IV) chelate were obtained, when 1 μg of Zr(IV) and Hf(IV) ions were determined by the present SPE/LC method from the sample volume of 100 ml. The established, pre-concentration SPE conditions, along with the LC separation and determination allow the assay of Zr(IV) and Hf(IV) in complicated matrix materials. The present SPE/LC method was applied to the determination of Zr(IV) and Hf(IV) in tap water and reference geological material (rock, NCS DC 73303; certified content: Zr, 27.7×10−3% (w/w) and Hf, 6.5×10−4% (w/w)).  相似文献   

19.
Sulfate-selective electrodes can be fabricated from commercial platinum electrodes by coating them with a mixture of Aliquat-336 and trifluoroacetyl-p-butylbenzene in polyvinyl chloride matrix. Adding a solid, sparingly soluble sulfate such as that of strontium, lead, barium, or 2-aminoperimidine (2-AP) improves the selectivity for sulfate relative to nitrate. The 2-AP electrode shows the best physical stability and is described in detail. The order ofanion interference is ClO4->Cl->NO3->H2PO4->F-. The useful pH range is 4–9. The response is Nernstian from 10-5 to 10-1 M in sodium sulfate solutions.  相似文献   

20.
Pankaj Kumar 《Talanta》2010,82(4):1107-1112
An all-solid-state electrode, containing a synthesized chiral A2B2 macrocyclic compound namely (4R,5R,15R,16R)-4,5,15,16-tetraphenyl-3,6,14,17-tetraazatricyclo [13.3.1.18,12] tetracosa-1(23),8,10,12(24)19,21-hexaene-2,7,13,18-tetrone as an ionophore in polyvinyl chloride (PVC)/polyurethane (PU) membrane matrix, has been developed for the selective quantification of monohydrogen phosphate ions. The best performing membrane contained PVC, PU, ionophore, and nitrophenyl octyl ether as a plasticizer in the ratio 32.2:2.6:65.1 (w/w, %). It exhibited a near-Nernstian slope of 31.0 ± 1.0 mV/decade of activity for HPO42− ions in the concentration range of 1.0 × 10−6 to 1.0 × 10−2 M at pH 7.4. The detection limit of the electrode was 8.4 × 10−7 M and the life time was six weeks. The electrode displayed excellent selectivity for monohydrogen phosphate over other anions and the selectivity sequence was determined as HPO42− > SO42− > Ac > NO3 > ClO4 > Cl > I. The selective electrode for the monohydrogen phosphate ions was evaluated with a standard reference material (SRM 1548) and the titration of the sample solution.  相似文献   