首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Chuang JC  Emon JM  Durnford J  Thomas K 《Talanta》2005,67(3):658-666
An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within ±20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30 ng/mL by ELISA and 0.2 ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10 mL of urine converted into 1 mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.  相似文献   

2.
A novel application of second-order calibration method based on an alternating penalty trilinear decomposition (APTLD) algorithm is presented to treat the data from high performance liquid chromatography-diode array detection (HPLC-DAD). The method makes it possible to accurately and reliably analyze atrazine (ATR), ametryn (AME) and prometryne (PRO) contents in soil, river sediment and wastewater samples. Satisfactory results are obtained although the elution and spectral profiles of the analytes are heavily overlapped with the background in environmental samples. The obtained average recoveries for ATR, AME and PRO are 99.7 ± 1.5, 98.4 ± 4.7 and 97.0 ± 4.4% in soil samples, 100.1 ± 3.2, 100.7 ± 3.4 and 96.4 ± 3.8% in river sediment samples, and 100.1 ± 3.5, 101.8 ± 4.2 and 101.4 ± 3.6% in wastewater samples, respectively. Furthermore, the accuracy and precision of the proposed method are evaluated with the elliptical joint confidence region (EJCR) test. It lights a new avenue to determine quantitatively herbicides in environmental samples with a simple pretreatment procedure and provides the scientific basis for an improved environment management through a better understanding of the wastewater-soil-river sediment system as a whole.  相似文献   

3.
A polyclonal antibody (Ab) for the progestin levonorgestrel (LNG) was generated, and immunochemical assays for its detection, clean-up and concentration were developed. A highly specific microplate diagnostic assay for the detection of LNG was developed that used the enzyme linked immunosorbent assay (ELISA) method. The LNG ELISA developed was sensitive and reproducible; it exhibited I50 and I20 values of 3.3 ± 1.8 ng mL−1 and 0.6 ± 0.4 ng mL−1, respectively, and the Abs did not cross react with any of the tested steroid hormones. The above Abs were used to develop a sol-gel-based immunoaffinity purification (IAP) method for concentration and clean-up of LNG that is compatible with subsequent immunochemical or instrumental chemical analytical procedures, such as liquid chromatography followed by mass spectrometry (LC-MS/MS). Development of the columns included successful entrapment of Abs within a tetramethoxysilane (TMOS)-based SiO2 polymer network. The Abs could bind the free analyte from solution, and the bound analyte could be easily eluted from the sol-gel matrix at high recoveries. The Ab selectivity towards the antigen was high, in both ELISA and the sol-gel columns, but the entrapped Abs cross-reacted with two other steroid hormones - ethynylestradiol (EE2) and nortestosterone (NT) - which share similar epitopes with LNG, despite the lack of cross reactivity in the ELISA. The validity of the method was investigated by LC-MS/MS and a good analytical correlation was obtained.  相似文献   

4.
Ali I  Naim L  Ghanem A  Aboul-Enein HY 《Talanta》2006,69(4):1013-1017
Recently, two new immobilized polysaccharides based CSPs, namely tris-(3,5-dimethylphenylcarbamate) derivatives of amylose and cellulose known as Chiralpak IA and Chiralpak IB were introduced, which may be used with a wide range of solvents including standard and prohibited ones. Several racemic piperidine-2,6-dione analogues [aminoglutethimide, p-nitro-glutethimide, p-nitro-5-aminoglutethimide, cyclohexylaminoglutethimide, phenglutarimide and thalidomide] have been resolved on Chiralpak IA and Chiralpak IB columns (25 cm × 0.46 cm). The non-conventional mobile phases used were methyl-tert-butyl ether-THF (90:10, v/v) [I], 100% dichloromethane [II] and 100% acetonitrile [III] separately at a flow rate of 1.0 mL/min using a UV detector at 254 nm. The resolution factors for Chiralpak IA and Chiralpak IB columns were 1.00-5.33 and 0.33-0.67, respectively. Chiralpak IA column gave better results than Chiralpak IB column for the reported molecules using the developed HPLC conditions. Experimental conditions and the possible chiral recognition mechanisms have been discussed.  相似文献   

5.
Valve-based comprehensive two-dimensional gas chromatography (GC × GC) is one of the most compact, robust, and inexpensive GC × GC instrument designs. The major drawback of a valve-based modulation configuration lies in diminished detection sensitivity. This loss in sensitivity is because under typical operating conditions the fraction of the first column (i.e., column 1) effluent transferred to the second column (i.e., column 2) is likely to be ∼5-10%. To address this loss in sensitivity, we report the development of a unique total-transfer (i.e., 100%) valve-based GC × GC, without adding complexity to the instrumentation. The new instrument design relies upon simply blocking one of the appropriate ports of the high-speed six-port diaphragm valve that is used as the modulator between columns 1 and 2. The modulation period and difference in head pressure between columns 1 and 2 are found to be the two primary variables that are controlled to provide good detection sensitivity and 100% mass transfer from column 1 to column 2. The detection sensitivity is better with a longer the modulation period. A limit of detection of 0.03 ng/μl was obtained for octane. This sensitive GC × GC configuration is also shown to provide acceptable separation peak capacity, with good separations achieved for real complex samples: gasoline and Eucalyptus oil, where compounds were spread out over much of the two-dimensional separation space. In principle, this total-transfer, valve-based GC × GC is more portable and less expensive than currently available GC × GC instrumentation.  相似文献   

6.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration.  相似文献   

7.
Petroleum hydrocarbons (oil) are common environmental contaminants. For risk assessment purposes, their concentrations in environmental matrixes, such as biota and soils/sediments are frequently determined by solvent extraction and subsequent analysis with gas chromatography (GC) equipped with flame ionization detection (FID) or mass spectrometry (MS). Because the total GC detector response is labeled as total petroleum hydrocarbon (TPH) concentration and matrix compounds (lipids, organic matter) will contribute to this response, proper extract clean-up is crucial. Still, the choice for a specific clean-up material during open column chromatography often seems arbitrary, since no comparative study on clean-up agents for TPH analysis is available. Here, such a study is described and it is demonstrated that none of the commonly used agents fulfills the requirements of complete matrix compound removal and TPH recovery. A novel column filled with (top-down) 1 g of 33% (w/w) 1 M NaOH-impregnated and 2.2 g of 7% (w/w) H2SO4-impregnated silica gel is recommended for cleaning-up biota extracts, as it fully removes extracted lipids and yields acceptable TPH recoveries of around 90%, based on a certified oil reference standard. For sediment extracts, most columns tested resulted in a negligibly low contribution of matrix compounds to the overall detector response, but 5% deactivated Florisil or 10% deactivated aluminum oxide are preferable, because these materials yield the highest (∼95%) TPH recoveries.  相似文献   

8.
Hydrodynamic chromatography (HDC) was used as a size classification and purification method for porous bridged ethyl hybrid (BEH) packing materials (particles) in the micron to sub-micron range. Using packed column HDC, a batch of particles with size 0.76 ± 0.26 μm was fractionated to yield classified material of 1.05 ± 0.16 μm, reducing the relative standard deviation from 33% to 15%. Subsequent chromatographic evaluation of this packing material showed significant improvement in column performance and decrease in flow resistance over the unclassified material. Comparing a column packed with the classified versus non-classified material, the effective flow resistance of the two columns was decreased by 58% and the minimum HETP for the packing material was improved from 4 to 2.5 μm.  相似文献   

9.
The three forms of enterostatin (Ala-Pro-Gly-Pro-Arg, Val-Pro-Gly-Pro-Arg, and Val-Pro-Asp-Pro-Arg), pentapeptides known to inhibit fat-intake, were resolved on a C18 reversed-phase column using a ternary mobile phase consisting of methanol, acetonitrile, and water. Coupled with MS/MS detection, the method has been applied to identify enterostatin sequences in human cerebrospinal fluid and rat brain tissue. Ala-Pro-Gly-Pro-Arg (APGPR) was found to be the predominant enterostatin sequence in both cases. The levels of APGPR were 98.3±16.3 ng/ml in human cerebrospinal fluid and 30.1±12.6 ng/g wet tissue in rat brain, respectively.  相似文献   

10.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7 ± 4.2% and 75.0 ± 1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL−1 and 1-300 ng mL−1, respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL−1 and 0.21 ng mL−1 for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g−1 and 1.3 mg g−1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.  相似文献   

11.
Triclocarban is an antimicrobial and antibacterial agent found in personal care products and subsequently is a prevalent wastewater contaminant. A quantitative method was developed for the analysis of triclocarban in wastewater effluents using stir bar sorptive extraction–liquid desorption (SBSE–LD) followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) by means of an electrospray interface. A stir bar coated with polydimethylsiloxane (PDMS) is placed within a vial containing wastewater effluent and is stirred for an hour at room temperature. The PDMS stir bar is then placed in a LC vial containing methanol and is desorbed in a sonicator bath. The methanol is evaporated to dryness and reconstituted in 75% methanol. Spike and recovery experiments in groundwater that did not contain native concentrations of triclocarban were performed at 0.5 μg/L and were 93 ± 8%. Recoveries in wastewater effluent that were corrected for the background levels of triclocarban were 92 ± 2% and 96 ± 5%, respectively, when spiked with 0.5 and 5 μg/L of triclocarban. The precision of the method as indicated by the relative standard error was 2%. The limit of quantitation was 10 ng/L. The SBSE–LD–LC/MS/MS method was applied to wastewater effluent samples collected from northeast Ohio. Triclocarban was quantitated in all five effluent samples, and its concentration ranged from 50 to 330 ng/L. The described method demonstrates a simple, green, low-sample volume, yet, sensitive method to measure triclocarban in aqueous matrices.  相似文献   

12.
Chuang JC  Van Emon JM  Trejo RM  Durnford J 《Talanta》2011,83(5):658-1323
An enzyme-linked immunosorbent assay (ELISA) method was employed for determination of the pyrethroid biomarker, 3-phenoxybenzoic acid (3-PBA) in human urine samples. The optimized coating antigen concentration was 0.5 ng/mL with a dilution of 1:4000 for the 3-PBA antibody and 1:6000 for the enzyme conjugate. Urine samples were hydrolyzed with concentrated hydrochloric acid; extracted with dichloromethane and solvent-exchanged into a methanol/buffer solution, prior to analysis in a 96-microwell plate immunoassay. Quantitative recoveries of 3-PBA were obtained for fortified urine samples by ELISA (92 ± 18%) as well as by gas chromatography/mass spectrometry (GC/MS) (90 ± 13%). The overall method precision of these samples was within ±20% for both the ELISA and GC/MS methods. Analytical results from over one hundred urine samples showed that the ELISA and GC/MS data were highly correlated, with a correlation coefficient of 0.95. At the 10 ng/mL comparative concentration level, the false positive rate was 0% and the false negative rate was 0.8% for ELISA when using GC/MS as the reference method. The ELISA method has a suitable low detection limit for 3-PBA to assess pyrethroid exposures in non-occupational settings.  相似文献   

13.
Book Reviews     
A gas chromatography/ion trap mass spectrometry method was used for the trace analysis of atrazine and its deethylated degradation product deethylatrazine in environmental water and sediment samples. The isotope dilution technique was applied for the quantitative analysis of atrazine at parts-per-trillion levels. Water samples were pre-concentrated by solid-phase extraction using a C18 cartridge while the sediment samples were extracted by sonication with methanol. The concentrated extracts were analysed by a GC/ion trap MS operated in the MS/MS method. The extraction recoveries for the analytes were better than 83% when 1 L of water or 10 g of sediment was analysed. The method detection limits were 0.75 ng/L and 0.13 ng/g for atrazine and deethylatrazine detected in water and sediment, respectively. The precisions of the method represented by the relative standard deviation were in the range of 3.2-16.1%. The method was successfully applied to analyse surface water and sediment samples collected from Beijing Guanting reservoir. Trace levels of atrazine at 35.9-217.3 ng/L and 2.4-8.4 ng/g were detected in the water and sediment samples, respectively. The levels of deethylatrazine were five to 20 times lower that those of atrazine.  相似文献   

14.
An immunoaffinity (IA) sorbent with antibody fragments was prepared for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis–mass spectrometry (IA-SPE-CE–MS). The antibody fragmentation was evaluated by MALDI-TOF-MS. Fab′ fragments obtained from a polyclonal IgG antibody against Endomorphins 1 and 2 (End1 and End2) were covalently attached to succinimidyl silica particles to prepare the IA sorbent. An IA-SPE-CE–MS methodology was established analyzing standard solutions of End1 and End2 and acceptable repeatability, linearity ranges and LODs (0.5 and 5 ng mL−1, respectively) were obtained. The LOD of End1 was slightly better than that previously obtained using an IA sorbent with intact antibodies (1 ng mL−1). In human plasma samples, End1 and End2 could be detected at 1 and 50 ng mL−1, respectively, which meant an improvement of 100 and 2-fold with regard to the LODs using an IA sorbent with intact antibodies (100 ng mL−1).  相似文献   

15.
A multiplexed dual-secondary column comprehensive two-dimensional gas chromatography approach (GC × 2GC) designed for complex sample analysis is introduced. The approach splits the first-dimension column effluent into two second-dimension columns with different stationary phases, and recombines the two streams into one detector post-separation. The approach produces two single two-dimensional chromatograms for each injection. Careful manipulation of thermal modulator timing parameters combined with a novel contra-directional modulation regime facilitates this approach. A selection of 34 laboratory reference compounds containing n-alkanes, alcohols, aromatic hydrocarbons, ketones, esters and halogenated hydrocarbons were analysed to demonstrate the approach. The dual two-dimensional chromatogram from this single detector system provides complementary information due to the unique selectivity of the three separation columns. The results of this proof-of-principle investigation provide significant impetus for further development of GC × 2GC–MS methodology.  相似文献   

16.
In this study, a new system for analysis using a dual comprehensive two-dimensional gas chromatography/targeted multidimensional gas chromatography (switchable GC × GC/targeted MDGC) analysis was developed. The configuration of this system not only permits the independent operation of GC, GC × GC and targeted MDGC analyses in separate analyses, but also allows the mode to be switched from GC × GC to targeted MDGC any number of times through a single analysis. By incorporating a Deans switch microfluidics transfer module prior to a cryotrapping device, the flow stream from the first dimension column can be directed to either one of two second dimension columns in a classical heart-cutting operation. Both second columns pass through the cryotrap to allow solute bands to be focused and then rapidly remobilized to the respective second columns. A short second column enables GC × GC operation, whilst a longer column is used for targeted MDGC. Validation of the system was performed using a standard mixture of compounds relevant to essential oil analysis, and then using compounds present at different abundances in lavender essential oil. Reproducibility of retention times and peak area responses demonstrated that there was negligible variation in the system over the course of multiple heart-cuts, and proved the reliable operation of the system. An application of the system to lavender oil, as a more complex sample, was carried out to affirm system feasibility, and demonstrate the ability of the system to target multiple components in the oil. The system was proposed to be useful for study of aroma-impact compounds where GC × GC can be incorporated with MDGC to permit precise identification of aroma-active compounds, where heart-cut multidimensional GC-olfactometry detection (MDGC-O) is a more appropriate technology for odour assessment.  相似文献   

17.
A broad range of organic compounds is recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This method was developed to better determine the distribution of 61 compounds that are typically associated with industrial and household waste as well as some that are toxic and known (or suspected) for endocrine-disrupting potential extracted from environmental sediment samples. Pressurized liquid extraction (PLE) coupled with solid-phase extraction (SPE) was used to reduce sample preparation time, reduce solvent consumption to one-fifth of that required using dichloromethane-based Soxhlet extraction, and to minimize background interferences for full scan GC/MS analysis. Recoveries from spiked Ottawa sand, commercially available topsoil, and environmental stream sediment, fortified at 4-720 μg per compound, averaged 76 ± 13%. Initial method detection limits for single-component compounds ranged from 12.5 to 520 μg/kg, based on 25 g samples. Results from 103 environmental sediment samples show that 36 out of 61 compounds (59%) were detected in at least one sample with concentrations ranging from 20 to 100,000 μg/kg. The most frequently detected compound, beta-sitosterol, a plant sterol, was detected in 87 of the 103 (84.5%) environmental samples with a concentration range 360-100,000 μg/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction are also compared.  相似文献   

18.
For the quantitative analysis of ‘compounds lacking authentic standards or surrogates’ (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2 ± 16.1% (TOF-MS) and 28.2 ± 27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4 ± 53.3% (TOF-MS) and 61.7 ± 81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84 ± 7.28% (TOF-MS) and 16.8 ± 8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN ≥ 4 (i.e., 25 aromatics and hexachlorobutadiene).  相似文献   

19.
Pueraria candollei associated preparation is widely applied in folk Thai medicine for rejuvenating purpose in aged people, which correlated with its pharmacological activities reported by pre-clinical and clinical trials. Therefore, standardized products of this plant are needed by consumers and health care personnel. Miroestrol, a potent and stable phytoestrogen in P. candollei, exhibited potential to be biomarker for quality control of P. candollei samples in research or industrial levels. Indirect competitive enzyme-linked immunosorbant assay (ELISA) for miroestrol determination was developed and validated by using polyclonal antibody from rabbit immunization. The polyclonal antibody recognized specifically to miroestrol, which exhibited cross-reactivity to deoxymiroestrol and isomiroestrol with 6.68% and 1.05%, respectively. The linearity range of measurement was 0.73–3000 ng mL−1, which coefficient of variation (CV) of both intra- and inter-plate determination was less than 5%. With spiked samples of known amount miroestrol, the percentages of recovery were 98.80–104.37% and 98.31–106.69% in P. candollei and its involved product samples, respectively. Validated ELISA was comparable with published HPLC method (R2 = 0.9996) (Yusakul et al. [18]) in samples with various miroestrol contents. For application, the P. candollei involved preparations contained miroestrol 0.695 ± 0.037–12.108 ± 0.285 μg g−1 dry wt. The developed ELISA was high performance for miroestrol determination, which could be applied for P. candollei quality control in research fields and industrial productions.  相似文献   

20.
Fentanyl and 16 of its corresponding homologs and analogs were distinguished using ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS). A 1.7 μm Acquity BEH C18 column (150 mm × 2.1 mm) was used with a 1% formic acid (pH 2.2), methanol gradient. Multiple-reaction monitoring (MRM) was employed for MS/MS detection. All selected fentanyl-related compounds, including incompletely resolved compounds, were uniquely identified using retention times and dual MRMs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号