1.
In this paper we describe the synthesis, characterisation and use of two distinct molecularly imprinted polymers (MIPs) prepared using esters of p-hydroxybenzoic acid (parabens) as templates: one MIP was synthesised by precipitation polymerisation using a semi-covalent molecularly imprinting strategy with methyl paraben as the template/target (MIP 1); the second MIP was prepared in monolithic form through a conventional non-covalent molecular imprinting strategy, with butyl paraben as the template (MIP 2). MIP 1 recognized methyl paraben, showed cross-selectivity for other parabens analytes used in the study and higher affinity towards these compounds than did a non-imprinted control polymer. Similarly, MIP 2 demonstrated higher affinity towards paraben analytes than a non-imprinted control polymer.For the analysis of environmental water samples, a solid-phase extraction (SPE) protocol was developed using MIP 2 as sorbent, and results were compared to a SPE using a commercial sorbent (Oasis HLB). With MIP 2 as sorbent and butyl paraben as target, when percolating 500 mL of river water spiked at 1 μg L−1 through the SPE cartridge, and using 1 mL of isopropanol as cleaning solvent, a higher recovery of butyl 4-hydroxybenzoate (butyl paraben) and a cleaner chromatogram where achievable when using the MIP compared to the commercial sorbent.  相似文献   

2.
The potential of carbon nanocones/disks as sorbent material in solid-phase extraction (SPE) procedures has been evaluated. For this aim, a model analytical problem, the determination of chlorophenols in water samples, was selected. An accurately weighed amount of 20 mg of purified carbon nanocones/disks was packed in 3 mL commercial SPE cartridges. Once conditioned, up to 8 mL of water samples can be preconcentrated without analyte losses. The chlorophenols were eluted by using 200 μL of hexane. Aliquots of 2 μL of the organic extract were injected in the gas chromatograph–mass spectrometer for separation and quantification. The purification of the commercial nanocones/disks to reduce the presence of amorphous carbon has been successfully achieved by heating the carbon nanocones/disks at 450 °C for 20 min. Detection limits of chlorophenols were in the range 0.3–8 ng mL−1 by using 2 mL of sample. Moreover, excellent average recovery values (98.8–100.9%) have been obtained after the analysis of water samples from different nature. Finally, the performance of the carbon nanocones/disks as sorbent material has been compared with that of multiwalled carbon nanotubes, providing the former better results under the experimental conditions assayed.  相似文献   

3.
An extraction-preconcentration procedure based on the use of a molecularly imprinted polymer (MIP) as selective sorbent has been developed for the determination of several phenolic compounds (bisphenol-A, bisphenol-F and 4-nitrophenol) and phenoxyacid herbicides (2,4-D, 2,4,5-T and 2,4,5-TP) in honey samples. Liquid chromatography with diode array detection (LC-DAD) and electrospray ionisation-ion trap mass spectrometry (LC-IT-MS) were used for the separation, identification and quantification of these analytes.The molecularly imprinted polymer was obtained by precipitation polymerisation with bisphenol-A (BPA) as template and 4-vinylpyridine as the functional monomer. The behaviour of this sorbent was compared with those of other materials frequently used in SPE. The selectivity of the BPA-MIP for the target analytes was tested in samples containing other pesticides in common use. The recoveries achieved for all six compounds were in the 81-96% range.By applying the proposed procedure prior to LC-IT-MS, the limits of detection achieved in commercial honey samples were in the 0.1-3.8 ng g−1 range, with relative standard deviations of 12-24%.  相似文献   

4.
Solid-phase extraction (SPE) procedures for cleanup and preconcentration followed by HPLC-UV method were investigated for the simultaneous determination of seven low-dosed pesticides in saline concentrates for hemodialysis. The target compounds were ametryn, desmetryn, prometryn, terbutryn, molinate, triallate and butylate. Polyethylene (three different types), teflon, polyurethane and polystyrene, in powder form, were investigated as adsorbents for solid-phase extraction of the analytes from the saline samples. Quantification was performed at 222 nm and the analytes were separated on a LiChrosorb RP-18 (5 μm, 125 mm × 4 mm i.d.) column using gradient elution with water/acetonitrile as mobile phase. The duration each chromatographic run was 18 min including column reconditioning. The efficiency of the different SPE substrates for retaining the analytes from the highly concentrated saline (HCS) samples was discussed. The best performance was achieved with polystyrene as SPE material considering preconcentration factor, precolumn clogging, reusing capability and similarity between the mobile phases for SPE and HPLC procedures. Analyte concentrations as low as 1 μg L−1 could be determined in spiked HCS samples after preconcentration on polystyrene SPE precolumns. Recoveries between 98.7 and 102.2% were obtained from commercial spiked samples. Detection limits ranging from 4.8 (for prometryn) to 46 μg L−1 (for butylate) were calculated (without preconcentration). The within-day relative standard deviations (n = 9) ranged from 2.3 to 4.8%.  相似文献   

5.
A novel approach for assembling homogeneous hyperbranched polymers based on non-covalent interactions with aflatoxins was developed; the polymers were used to evaluate the extraction of aflatoxins B1, B2, G1 and G2 (AFB1, AFB2, AFG1 and AFG2) in simulant solutions. The results showed that the extraction efficiencies of three kinds of synthesized polymers for the investigated analytes were not statistically different; as a consequence, one of the representative polymers (polymer I) was used as the solid-phase extraction (SPE) sorbent to evaluate the influences of various parameters, such as desorption conditions, pH, ionic strength, concentration of methanol in sample solutions, and the mass of the sorbent on the extraction efficiency. In addition, the extraction efficiencies for these aflatoxins were compared between the investigated polymer and the traditional sorbent C18. The results showed that the investigated polymer had superior extraction efficiencies. Subsequently, the proposed polymer for the SPE packing material was employed to enrich and analyze four aflatoxins in the cereal powder samples. The limits of detection (LODs) at a signal-to-noise (S/N) ratio of 3 were in the range of 0.012–0.120 ng g−1 for four aflatoxins, and the limits of quantification (LOQs) calculated at S/N = 10 were from 0.04 to 0.40 ng g−1 for four aflatoxins. The recoveries of four aflatoxins from cereal powder samples were in the range of 82.7–103% with relative standard deviations (RSDs) lower than 10%. The results demonstrate the suitability of the SPE approach for the analysis of trace aflatoxins in cereal powder samples.  相似文献   

6.
Three new hypercrosslinked polymers with hydrophilic character arising from hydroxyl moieties in their skeletons have been prepared in microsphere format and applied to the off-line solid-phase extraction (SPE) of polar compounds from water samples. For sample volumes of 1000 ml, the recoveries of various polar pesticides, such as oxamyl, methomyl, selected phenolic compounds, as well as some pharmaceuticals, were close to 90%. The HXLPP-polar polymer with the best performance characteristics was applied to real samples. Its performance was also compared to commercially available sorbents, such as LiChrolut EN (hydrophobic, hypercrosslinked), Oasis HLB (hydrophilic, macroporous) and Isolute ENV+ (hydrophilic, hypercrosslinked); the new sorbent out-performed the commercially available sorbents. The polymer was applied successfully in off-line SPE of river water samples followed by liquid chromatography and ultraviolet detection, providing a good linear range and detection limits of 0.2 μg l−1 for the majority of the compounds, with the exception of oxamyl, methomyl, guaiacol and salicylic acid where the detection limit was 0.5 μg l−1.  相似文献   

7.
Two innovative integrative samplers have been developed enabling high sampling rates unaffected by turbulences (thus avoiding the use of performance reference compounds) and with negligible lag time values. The first, called the constantly stirred sorbent (CSS) consists of a rotator head that holds the sorbent. The rotation speed given to the head generates a constant turbulence around the sorbent making it independent of the external hydrodynamics. The second, called the continuous flow integrative sampler (CFIS) consists of a small peristaltic pump which produces a constant flow through a glass cell. The sorbent is located inside this cell. Although different sorbents can be used, poly(dimethylsiloxane) PDMS under the commercial twister format (typically used for stir bar sorptive extraction) was evaluated for the sampling of six polycyclic aromatic hydrocarbons and three organochlorine pesticides. These new devices have many analogies with passive samplers but cannot truly be defined as such since they need a small energy supply of around 0.5 W supplied by a battery. Sampling rates from 181 × 10−3 to 791 × 10−3 L/day were obtained with CSS and 18 × 10−3 to 53 × 10−3 with CFIS. Limits of detection for these devices are in the range from 0.3 to 544 pg/L with a precision below 20%. An in field evaluation for both devices was carried out for a 5 days sampling period in the outlet of a waste water treatment plant with comparable results to those obtained with a classical sampling method.  相似文献   

8.
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C18 cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L−1 and limits of quantification (LOQs) from 0.003 to 1.452 μg L−1. For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L−1 and LOQs ranged from 0.011 to 3.494 μg L−1. Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L−1, whereas methiocarb sulfoxide was detected at trace levels in two samples.  相似文献   

9.
The sensitive multiresidual analytical method for simultaneous analysis of 14 most commonly used agricultural pesticides in Serbia was developed and optimized. The selected insecticides, fungicides and herbicides belong to seven chemical classes (organophosphates, neonicotinoids, carbamates, diacylhydrazines, benzimidazoles, triazines and phenylureas). The method was based on solid-phase extraction followed by liquid chromatography-tandem mass spectrometry. The following parameters that may affect the SPE procedure efficiency were optimized: the sorbent type in combination with different elution solvents, the sample pH and the sample volume. For each pesticide, MSn analysis was performed and distinctive ions and transitions were selected for identification and quantification, as well as for confirmation purposes. External matrix-matched calibration method was used to eliminate variable matrix effect and ensure precise quantification. Good recoveries (72-129%), and low limits of detection (0.4-5.5 ng L−1) and quantification (1.1-18.2 ng L−1) were achieved for all selected pesticides. The developed and optimized method was successfully applied in the analysis of several river waters, as well as ground waters in Serbia, influenced by agriculture. The most frequently detected pesticide was carbendazim. Dimethoate, carbofuran and propazine were also found in the investigated samples.  相似文献   

10.
A novel approach for the determination of seven fungicides (metalaxyl-M, penconazole, folpet, diniconazole, propiconazole, difenoconazole and azoxystrobin) in wine samples is presented. Analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE) followed by dispersive liquid–liquid microextraction (DLLME). Variables affecting the performance of both steps were thoroughly investigated (metalaxyl-M was not included in some optimisation studies) and their effects on the selectivity and efficiency of the whole sample preparation process are discussed. Under optimised conditions, 20 mL of wine were first concentrated using a reversed-phase sorbent and then target compounds were eluted with 1 mL of acetone. This extract was mixed with 0.1 mL of 1,1,1-trichloroethane (CH3CCl3) and the blend added to 10 mL of ultrapure water. After centrifugation, an aliquot (1–2 μL) of the settled organic phase was analyzed by gas chromatography (GC) with electron capture (ECD) and mass spectrometry (MS) detection. The method provided enrichment factors (EFs) around 200 times and an improved selectivity in comparison to use of SPE as single sample preparation technique. Moreover, the yield of the global process was similar for red and white wine samples and the achieved limits of quantification (LOQs) (from 30 to 120 ng L−1 and from 40 to 250 ng L−1, for GC–ECD and GC–MS, respectively) were low enough for the determination of target species in commercial wines. Among compounds considered in this work, metalaxyl-M and azoxystrobin were found in several wines at concentrations from 0.8 to 32 ng mL−1.  相似文献   

11.
Xiaoman Jiang  Mancang Liu 《Talanta》2007,72(1):119-125
A novel and simple imprinted amino-functionalized silica gel material was synthesized by combining a surface molecular imprinting technique with a sol-gel process on the supporter of activated silica gel for solid-phase extraction-high performance liquid chromatography (SPE-HPLC) determination of bisphenol A (BPA). Non-imprinted silica sorbent was synthesized without the addition of BPA using the same procedure as that of BPA-imprinted silica sorbent. The BPA-imprinted silica sorbent and non-imprinted silica sorbent were characterized by FT-IR and the static adsorption experiments. The prepared BPA-imprinted silica sorbent showed high adsorption capacity, significant selectivity and good site accessibility for BPA. The maximum static adsorption capacity of the BPA-imprinted and non-imprinted silica sorbent for BPA was 68.9 and 34.0 mg g−1, respectively. The relatively selective factor value of this BPA-imprinted silica sorbent was 4.5. Furthermore, the difference of the retention characteristics of BPA on the C8 SPE column and BPA-imprinted silica SPE (MIP-SPE) was compared. The MIP-SPE-HPLC method showed higher selectivity to BPA than the traditional SPE-HPLC method. At last, the BPA-imprinted polymers were used as the sorbent in solid-phase extraction to determine BPA in water samples with satisfactory recovery higher than 99% (R.S.D. 3.7%).  相似文献   

12.
A pyrrole-based conductive polymer was prepared and applied as new sorbent for on-line solid-phase extraction (SPE) of phenol and chlorophenols from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in non-aqueous solution. The efficiency of this polymer for extraction of phenol and chlorophenols was evaluated using 35 mg of PPy as the sorbent in an on-line SPE system coupled to reversed-phase liquid chromatography with UV detection. The mobile phase were mixture of phosphate buffer-acetonitrile and compounds were eluted by the mobile phase using a six-port switching valve. High volumes of water, up to 160 ml, could be preconcentrated without the loss of phenols, except for the more polar ones. The R.S.D. for a river water sample spiked with phenol and chlorophenols at sub-ppb level was lower than 7% (n=5) and detection limits of 15-100 and 35-150 ng l−1 for tap and river water were obtained, respectively.  相似文献   

13.
This article presents a novel application of carbon nanotubes for the determination of pesticides (chlortoluron, diuron, atrazine, simazine, terbuthylazin-desethyl, dimetoathe, malathion and parathion) in virgin olive oil samples. For this purpose, two carbon nanotubes, multi-walled and carboxylated single-walled, were evaluated, the later being the most appropriate for the aim of the work. The sorbent (30 mg) was packed in 3-mL commercial cartridge and the virgin olive oil samples diluted (20%, v/v) in hexane were passed through it. After a washing step with 3 mL of hexane to remove the sample matrix, the pesticides were eluted with 500 μL of ethyl acetate. In order to achieve lower detection limits, the eluent was evaporated under a nitrogen stream and the residue reconstituted in 50 μL of the same solvent. Aliquots of 2 μL of the extract were directly injected into the GC–MS system for analysis. The low limits of detection achieved, between 1.5 and 3.0 μg L−1, permit the application of the method to control the presence of these pollutants in very restrictive samples such as the ecological virgin olive oil. In addition to the sensitivity enhancement, the solid-phase extraction procedure is rather simple as it involves a single preconcentration–elution step, which allows sample processing in less than 8 min. Moreover, the cartridge can be reused at least 100 times without losing performance. The method was applied to the determination of the pesticides in two monovarietal and one ecologic commercial extra virgin olive oil samples. Two pesticides were detected in each of the monovarietal virgin olive oils while the ecological sample resulted to be a pesticide-free one.  相似文献   

14.
The synthesis of high specific surface area sorbents (HXLPP-WCX) in the form of hypercrosslinked polymer microspheres with narrow particle size distributions, average particle diameters around 6 μm, and weak cation-exchange (WCX) character, is described. The WCX character arises from carboxylic acid moieties in the polymers, derived from the comonomer methacrylic acid. A novel HXLPP-WCX sorbent with an attractive set of chemical and physical properties was then used in an off-line solid-phase extraction (SPE) protocol for the selective extraction of a group of basic compounds from complex environmental samples, a priority being the clean separation of the basic compounds of interest from acidic compounds and interferences. The separation power of the new sorbent for basic pharmaceuticals was compared to two commercially available, mixed-mode sorbents, namely Oasis WCX and Strata-X-CW. Under identical experimental conditions, HXLPP-WCX was found to deliver both higher capacity and better selectivity in SPE than either of the two commercially available materials. In an optimised SPE protocol, the HXLPP-WCX sorbent gave rise to quantitative and selective extractions of low μg l−1 levels of basic pharmaceuticals present in 500 ml of river water and 250 ml of effluent waste water.  相似文献   

15.
Solid-phase extraction (SPE) was combined with headspace solid-phase microextraction (HS-SPME) for the highly effective enrichment of 17 ultra trace organochlorine pesticides in water samples. The target compounds were successfully transferred from water samples to a gas chromatography capillary column by means of four consecutive steps, namely SPE, solvent conversion, HS-SPME, and thermal desorption of the SPME fiber. Parameters, including elution volume and breakthrough volume in the SPE step, temperature in the solvent conversion step, and fiber type, ionic strength, extraction temperature, extraction time, and pH in the SPME step were optimized to improve the performance of the method through either single factor comparative experiment or the orthogonal experimental design approach. After optimization, the method gave high sensitivity with a method detection limit ranging from 0.0018 to 0.027 ng L−1, good repeatability with a relative standard deviation less than 20% (n = 4) and acceptable recovery with a value mostly exceeding 60%. External standard calibration was employed for the quantification, and a wide linear range (from 0.0010 to 60 ng mL−1) with R2 values ranging from 0.9988 to 0.9999 were observed. In the end, the method was successfully applied to the Arctic samples, and the results showed that, among all the organochlorine pesticides, hexachlorocyclohexanes (HCHs) were the most predominant in the Arctic surface water body with sum of their concentrations ranging from 0.262 to 3.156 ng L−1.  相似文献   

16.
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L−1.This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L−1).  相似文献   

17.
A new gallium (Ga(III)) ion-imprinted multi-walled carbon nanotubes (CNTs) composite sorbent was synthesized by a surface imprinting technique. The Ga(III) ion-imprinted/multi-walled carbon nanotubes (Ga(III)-imprinted/CNTs) sorbent was characterized by Fourier transform infrared (FT-IR), X-ray diffraction (XRD), nitrogen adsorption experiment, static adsorption experiment, and solid-phase extraction (SPE) experiment. The effects of sample volume, sample pH, washing and elution conditions on the extraction of Ga(III) ion from real sample were studied in detail. The imprinted sorbent offered a fast kinetics for the adsorption of Ga(III). The maximum static adsorption capacity of the imprinted sorbent towards was 58.8 μmol g−1. The largest selectivity coefficient for Ga(III) in the presence of Al(III) was over 57.3. Compared with non-imprinted sorbent, the imprinted sorbent showed good imprinting effect for Ga(III) ion, the imprinting factor (α) was 2.6, the selectivity factor (β) was 2.4 and 2.9 for Al(III) and Zn(II), respectively. The developed imprinted SPE method was applied successfully to the detection of trace Ga(III) ion in fly ash samples with satisfactory results.  相似文献   

18.
Xiaoyi Wei  Gengliang Yang  Li Qi 《Talanta》2009,77(3):1197-1807
An on-line solid-phase extraction (SPE)-HPLC method was developed for simultaneous screening of nicardipine and amlodipine in human plasma. A short monolithic poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) [p(GMA-EDMA)]-based weak cation-exchange (WCX) column was prepared and employed as the selective extraction sorbent, which exhibited good permeability and biocompatibility. During the on-line SPE protocol, high-abundance proteins (human serum albumin, immunoglobulin G, immunoglobulin A and transferrin) and most matrixes in plasma were fast removed while nicardipine and amlodipine were effectively trapped on this monolithic column. Furthermore, the monolithic WCX sorbent could be continuously reused more than 300 times without obvious changes in analytes extraction and proteins cleanup. The proposed method was linear over a range of 0.5-50.0 ng mL−1 for both analytes with a linear regression coefficient greater than 0.998, and the limit of detection (LOD) for each analyte was 0.2 ng mL−1. Validation assays also demonstrated acceptable precision and adequate recovery for simultaneous quantitative screening of nicardipine and amlodipine in human plasma. Real plasma samples from hypertensive patients receiving a dosing of 5 mg antagonists were examined by using the proposed method. Results indicated that the on-line SPE-HPLC method could be applied for simultaneously monitoring of nicardipine and amlodipine in clinical plasma samples.  相似文献   

19.
Luo D  Yu QW  Yin HR  Feng YQ 《Analytica chimica acta》2007,588(2):261-267
A novel solid-phase extraction (SPE) sorbent, humic acid-bonded silica (HAS), was prepared. Humic acids (HAs) were grafted onto silica matrices via an amide linkage between humyl chloride and the amido terminus of 3-aminopropyltrimethoxysilane (APTS)-silica gel. The resulting material was characterized by Fourier transform infrared spectrometer, elemental analysis, and nitrogen adsorption analysis. This sorbent exhibits an excellent adsorption capacity for some electron-abundant analytes owing to its peculiar structure. In this paper, we choose benzo[a]pyrene (BaP) in oil as a probe to validate the adsorption capacity of the material. Thus a fast, cheap and simple SPE method with humic acid-bonded silica cartridge for edible oil clean-up, followed by high-performance liquid chromatography (HPLC) with fluorescence detection was established. The effects of experimental variables, such as washing and elution solvents, and the amount of sorbents have been studied. The recoveries of BaP in edible oils spiked at 0.2-100 μg kg−1 were in the range of 78.8-102.7% with relative standard deviations ranging between 1.3 and 9.3%; the limit of detection was -0.06 μg kg−1.  相似文献   

20.
A solid-phase extraction (SPE) using multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with gas chromatography–mass spectrometry (GC–MS) method was developed for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Several condition parameters, such as extraction adsorbents, elution solvents and volumes, and sample loading flow rate and volume were optimized to obtain high SPE recoveries and extraction efficiency. 150 mg MWCNTs as sorbent presented high extraction efficiency of 16 PAHs due to the large specific surface area and high adsorption capacity of MWCNTs compared with the commercial C18 column (250 mg/2 mL). The calibration curves of 16 PAHs extracted were linear in the range of 20–5000 ng L−1, with the correlation coefficients (r2) between 0.9848 and 0.9991. The method attained good precisions (relative standard deviation, RSD) from 1.2% to 12.1% for standard PAHs aqueous solutions; method recoveries ranged in 76.0–125.5%, 74.5–127.0%, and 70.0–122.0% for real spiked samples from river water, tap water and seawater, respectively. Limits of detection (LODs, S/N = 3) of the method were determined from 2.0 to 8.5 ng L−1. The optimized method was successfully applied to the determination of 16 PAHs in real environmental water samples.  相似文献   