首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
A new procedure has been developed for the on-line digestion of solids in a microwave oven. The direct injection in a water carrier flow of dispersions of solid samples in concentrated nitric acid, the merging of these slurries with 30% (v/v) H(2)O(2) and the microwave-assisted digestion in a Teflon coil of 100 cm permit a fast and quantitative extraction of Cu and Mn from different solid matrices, such as vegetables, powdered dietary products and sewage sludges. The development of an appropriate interphase, in which digested samples are cooled and degassified, previous to their introduction into the nebulizer of a flame atomic absorption spectrometer, makes possible the full automatization of the digestion and measurement steps of the elemental analysis of solids and it provides a sample frequency of 180 injections per hour. The developed procedure has also been applied for Pb and Zn determination in certified sewage sludge samples, with accurate results obtained for Pb but low results found for Zn.  相似文献   

2.
Udoh AP 《Talanta》2000,52(4):749-754
The phosphorus content of some animal protein sources was determined in order to identify the sample with the highest phosphorus content for use as a pilot sample. Varying concentrations of strontium and lanthanum were added to solutions of the ashed pilot sample for the determination of calcium and magnesium using flame atomic absorption spectrophotometry operated on the air-acetylene mode. At least 3000 ppm of strontium or lanthanum was required to completely overcome the interference of phosphate ion, PO(4)(3-), and give peak values for calcium. The presence of strontium or lanthanum did not affect the amount of magnesium obtained from the analyses. Based on this, a procedure is proposed and the results obtained by this procedure for calcium are more enhanced than those obtained without the addition of strontium or lanthanum for the same samples whereas comparable results were obtained for all other elements whether strontium or lanthanum was added or not. The method gives more accurate results and is reproducible. The coefficients of variation calculated using one of the samples were 0.58% for magnesium, 3.12% for zinc; 0.44% for calcium, 11.06% for lead, 22.22% for nickel, 3.53% for manganese and 3.50% for iron at the concentration levels found in that sample. Recoveries of spiked calcium, magnesium and zinc were quantitative. Also, for selected elements, results from the procedure compared well with those from chemical analysis.  相似文献   

3.
A solid-phase extraction (SPE) method involving selective usage of solvents has been developed for trace level identification of chemical warfare agents (CWAs) present in a complex organic background. The total ion chromatograms obtained from direct gas chromatography-electron ionization mass spectrometric analysis of samples spiked with CWAs in the presence of diesel are very complex and dominated by hydrocarbon peaks and the same after treatment with SPE show distinct peaks corresponding to spiked chemicals. The recovery of samples from SPE is found to be 70-85% at the 10 ppm level.  相似文献   

4.
Differential pulse anodic stripping voltammetry is used for the simultaneous determination of cadmium, lead and copper in different types of urine samples. Unlike most biological samples, urine can be analyzed directly for cadmium and lead without pretreatment of the sample; a significant increase in sensitivity is obtained if the analysis is carried out at an elevated temperature. The complete decomposition of urine with a mixture of nitric, perchloric and sulphuric acids is also described; this procedure makes it possible to determine copper simultaneously. Good agreement was obtained between the two procedures, and the recovery of metals from spiked samples was satisfactory for both methods. The relative merits of the two approaches are discussed.  相似文献   

5.
A rapid and sensitive method for the determination of 2,5-hexanedione (HD) (the principal metabolite of n-hexane) in urine samples by reversed-phase high-performance liquid chromatography (HPLC) is described. The sample preparation procedure was based on solid-liquid extraction after acid hydrolysis; it was optimized to enable accurate HD determination in less than 30 min. Analysis of spiked real samples showed a recovery of more than 85% at the 0.1-ppm level, with a relative standard deviation of 5% and a detection limit as low as 0.01 ppm. Intra-assay and inter-assay coefficients of variation at the 0.5-ppm level were 4 and 5%, respectively. The chromatographic peak assigned to HD was identified by collecting the HPLC eluate at the retention time of HD and analysing it using Fourier transform infrared spectrometry coupled with high-resolution gas chromatography. Urine samples of unexposed and exposed subjects were analysed following the proposed analytical procedure. HPLC and high-resolution gas chromatographic analyses were also compared on these samples. A correlation factor of 0.992 was obtained, which showed a good agreement between the two sets of data.  相似文献   

6.
The 2,4-dichlorophenoxy acetic acid (2,4-D) is used as a systemic herbicide to control broadleaf weeds in wheat, corn, range land/pasture land, sorghum, and barley. In this study, a fast and efficient method is developed by selection of modified extraction apparatus and high-performance liquid chromatography (HPLC)-UV conditions for the determination of 2,4-D in soil samples. The method is applied to the study of soil samples collected from the agricultural field. The herbicide is extracted from soil samples by acetonitrile in a modified Soxhlet apparatus. The advantages of the apparatus are that it uses small volume of organic solvent, reduced time of extraction, and better recovery of the analyte. The extract is filtered using a very fine microfiber paper. The total extract is concentrated in a rotatory evaporator, dried under ultrahigh pure N2, and finally reconstituted in 1 mL of acetonitrile. HPLC-UV at 228 nm is used for analysis. The herbicide is identified and quantitated using the HPLC system. The method is validated by the analysis of spiked soil samples. Recoveries obtained varied from 85% to 100% for spiked soil samples. The limit of quantitation (LOQ) and the limit of detection (LOD) are 0.010 and 0.005 parts per million (ppm), respectively, for spiked soil samples. The LOQ and LOD are 0.006 and 0.003 ppm for unspiked soil samples. The measured concentrations of 2,4-D in spiked soil samples are between 0.010 and 0.020 ppm with an average of 0.016 +/- 0.003 ppm. For unspiked soil samples it is between 0.006 ppm and 0.012 ppm with an average of 0.009 +/- 0.002 ppm. The measured concentrations of 2,4-D in soil samples are generally low and do not exceed the regulatory agencies guidelines.  相似文献   

7.
Campbell WC  Ottaway JM 《Talanta》1975,22(9):729-732
A simple and rapid method for the determination of 1-100 ppm of lead in carbonate rocks is described. Dissolution of the rock samples in 10% v v nitric acid is shown to give precise and accurate results even though silicates in the samples remain undissolved. A more time-consuming but complete dissolution of the sample with hydrofluoric acid may be used if preferred. The increase in sensitivity and freedom from matrix interference obtained by the use of a carbon-furnace atomizer eliminate the necessity for preconcentration of the lead, saving time and preventing errors from contamination or losses derived from inefficient extraction procedures. The detection limit and precision of the method are 0.4 ppm and 6% (relative standard deviation at the 3-ppm lead level) respectively and accurate results were obtained for the analysis of standard rock samples.  相似文献   

8.
Total reflection X-ray fluorescence spectrometry and chemical pre-concentration procedures have been applied for the analysis of trace concentrations of copper, mercury, and lead in drinking water samples. A simple total reflection module has been used in X-ray measurements. The elements under investigation were pre-concentrated by complexation using a mixture of carbamates followed by solvent extraction with methyl isobutyl ketone. The preconcentration procedure was tested with the use of twice-distilled water samples and samples of mineral and tap water spiked with known additions of copper, mercury, and lead. The obtained recovery and precision values are presented. The minimum detection limits for the determination of these elements in mineral and tap water samples were found to be 40 ng l−1, 60 ng l−1, and 60 ng l−1, respectively.  相似文献   

9.
A simple and effective analytical procedure has been developed for the determination of dimethoate (DIM) residues and its metabolite, omethoate, in serum samples of pesticide operators. For the selection of the most appropriate method for sample treatment, techniques such as headspace solid phase micro extraction and solid phase extraction and liquid–liquid extraction were applied. The applied method was based on toluene (2?mL) extraction of a 0.5?mL serum sample. In this report, it was observed that DIM concentration level affected the ratio of the area response of DIM and one of its oxygenated metabolite, omethoate. In this context, higher concentrations favoured the predominance of DIM while lower concentrations lead to the formation of omethoate. The method was validated using human serum samples spiked with DIM. Good linearity was obtained in the range of 1–10?ng/mL co-calculating DIM and omethoate. Various concentrations of DIM were mixed with serum and stored up to five days at ?20°C. Recoveries ranged from 72% to 88% at two spiking levels for six replicates. The detection and quantification limit were calculated at 0.12 and 0.36?ng/mL of serum, respectively. Finally the comparison with the Acceptable Operator Exposure Level (AOEL) of DIM revealed that the maximum exposure of the operators reached the 30% of the AOEL for only two cases.  相似文献   

10.
A simple, rapid and selective procedure for the indirect spectrophotometric determination of Se(IV) and As(V) has been developed. It is based on the reduction of Se(IV) to Se(0) and As(V) to As(III) with hydroiodic acid (KI + HCl). The liberated iodine, equivalent to each analyte, is quantitatively extracted with oleic acid (HOL) surfactant. The iodine-HOL system exhibits its maximum absorbance at 435 nm. The different analytical parameters affecting the extraction and determination processes have been examined. The calibration graphs were found to be linear over the ranges 5-120 and 0.25-20 ppm of Se(IV) and As(V), with lower detection limits of 2.5 and 0.15 ppm and molar absorptivities of 1 x 10(4) and 0.5 x 10(4) dm3 mol(-1) cm(-1), respectively. Sandell's sensitivity was calculated to be 0.0078 and 0.0149 microg/cm2 in the same order. The relative standard deviation for five replicate analyses of 40 ppm Se(IV) and 4 ppm As(V) were 1.0 and 0.9%, respectively. The proposed procedure in the presence of EDTA as a masking agent for foreign ions has been successfully applied to the determination of Se(IV) in a reference sample and As(V) in copper metal, in addition to their determination in spiked and polluted water samples.  相似文献   

11.
《Analytical letters》2012,45(14):2265-2278
A new analytical procedure for the determination of lead in lipstick has been developed using direct solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (SS HR CS GFAAS). The performance of this method has been compared to acid digestion methods for sample preparation, with or without hydrofluoric acid (HF) with inductively coupled plasma mass spectrometry (ICP-MS) detection. Good reliability was obtained for all three methods; the results obtained for certified reference materials with concentrations between 1 and 20 ppm were in agreement with the certified values. However, for materials with complex matrices, such as pearl or Ca-Na borosilicate, only ICP-MS with HF sample digestion or AAS with direct solid sampling allowed complete recovery of lead. To avoid the use of hazardous acids, the development of SS HR CS GFAAS is an interesting alternative. With the AAS method, a characteristic mass of 13.2 pg of lead was obtained, and the limit of detection was 0.005 µg/g. The performance of the method was evaluated by determining lead in lipstick. The use of the solid sampling technique constitutes a good alternative for accurate and rapid determination of lead content in lipstick and cosmetic raw materials, with a suitable limit of detection and a reduced risk of contamination or of analyte loss. Another alternative would be to use ICP-MS determination in conjunction with microwave-assisted acid digestion without the use of HF, which implies accepting a quantification of “nearly total” lead, closer to a “bio-extractible” fraction.  相似文献   

12.
We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6–21% for pressed pellets and 3–21% for fused solids were obtained from n = 3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches.  相似文献   

13.
X射线衍射定量相分析新方法   总被引:11,自引:2,他引:11  
在基体清洗法的基础上提出一种新的X射线衍射定量分析方法,该方法是利用混合样品X射线衍射谱图中的全部衍射峰数据,把清洗剂同样品中所包含的所有待测物相的纯相按比例混合,在同一水平下同时测定各物相与清洗剂对应的几个K值,结合JCPDS卡中的各相标准谱峰的相对强度分布数据进行最小二乘方程组的抛弃平均法回归分析,求得混合物样品中各相间的全谱峰匹配强度比,用于混合物样品的X射线衍射定量相分析,有利于提高定量相分析的精度,通过对四组分混合物样品的分析,实验结果和理论完全一致。  相似文献   

14.
A new approach to sample digestion, subsequent vaporization and introduction into an inductively coupled plasma atomic emission spectrometer was developed for the direct determination of lead. To each small sample cuvette made of tungsten, a mixture of a ground solid sample and powdered diammonium hydrogenphosphate was precisely weighed. The cuvette was positioned onto the tungsten boat furnace (TBF) incorporating a vaporizer. Tetramethylammonium hydroxide solution was added. Then the cuvette was heated and maintained at a wet-digestion temperature to decompose the solid sample. After digestion, the temperature was elevated to generate the analyte vapor for introduction into a plasma. Since the solid samples were wet-digested in the sample cuvettes before vaporization, they could be analyzed by using a calibration curve prepared from aqueous standard solutions. This method was applied to the determination of lead in several biological materials with satisfactory results.  相似文献   

15.
A new approach to sample digestion, subsequent vaporization and introduction into an inductively coupled plasma atomic emission spectrometer was developed for the direct determination of lead. To each small sample cuvette made of tungsten, a mixture of a ground solid sample and powdered diammonium hydrogenphosphate was precisely weighed. The cuvette was positioned onto the tungsten boat furnace (TBF) incorporating a vaporizer. Tetramethylammonium hydroxide solution was added. Then the cuvette was heated and maintained at a wet-digestion temperature to decompose the solid sample. After digestion, the temperature was elevated to generate the analyte vapor for introduction into a plasma. Since the solid samples were wet-digested in the sample cuvettes before vaporization, they could be analyzed by using a calibration curve prepared from aqueous standard solutions. This method was applied to the determination of lead in several biological materials with satisfactory results.  相似文献   

16.
A direct method for determination of silicon in powdered high-purity aluminium oxide samples, by slurry sampling with in situ fusion graphite-furnace atomic-absorption spectrometry (GF-AAS), has been established. A slurry sample was prepared by 10-min ultrasonication of a powdered sample in an aqueous solution containing both sodium carbonate and boric acid as a mixed flux. An appropriate portion of the slurry was introduced into a pyrolytic graphite furnace equipped with a platform. Silicon compounds to be determined and aluminium oxide were fused by the in situ fusion process with the flux in the furnace under optimized heating conditions, and the silicon absorbance was then measured directly. The calibration curve was prepared by use of a silicon standard solution containing the same concentration of the flux as the slurry sample. The accuracy of the proposed method was confirmed by analysis of certified reference materials. The proposed method gave statistically accurate values at the 95% confidence level. The detection limit was 3.3 microg g(-1) in solid samples, when 300 mg/20 mL slurry was prepared and a 10 microL portion of the slurry was measured. The precision of the determination (RSD for more than four separate determinations) was 14% and 2%, respectively, for levels of 10 and 100 microg g(-1) silicon in aluminium oxide.  相似文献   

17.
A rapid and easy method has been proposed, optimized and evaluated for quantitative determination at trace level of a representative group of non-polar pesticides in fat samples. The method includes n-hexane-saturated acetonitrile extraction, fat precipitation by cooling pre clean-up followed by dispersive solid-phase extraction (d-SPE) based on QuEChERS procedure clean-up. Determination was performed by gas chromatography?Cmass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. Efficiency of the d-SPE clean-up step was evaluated by comparison with fat oxidation treatment and gel permeation chromatography. Different combinations of d-SPE extraction reagents and sample amounts were tested in order to minimize matrix co-extractives and interferences. Best recoveries were obtained with 1200?mg of MgSO4, 400?mg of end-capped C18, 400?mg of PSA and 1?g of sample amount. SIM method, matrix effect, precision, and accuracy were evaluated with spiked pork fat samples for 38 representative pesticides. Results of this study showed that this technique is applicable in routine analysis for its application into monitoring programs. It simplifies time-consuming clean-up steps and allows a satisfactory long-term chromatographic performance.  相似文献   

18.
Bell SE  Sirimuthu NM 《The Analyst》2004,129(11):1032-1036
Rapid, quantitative SERS analysis of nicotine at ppm/ppb levels has been carried out using stable and inexpensive polymer-encapsulated Ag nanoparticles (gel-colls). The strongest nicotine band (1030 cm(-1)) was measured against d(5)-pyridine internal standard (974 cm(-1)) which was introduced during preparation of the stock gel-colls. Calibration plots of I(nic)/I(pyr) against the concentration of nicotine were non-linear but plotting I(nic)/I(pyr) against [nicotine](x)(x = 0.6-0.75, depending on the exact experimental conditions) gave linear calibrations over the range (0.1-10 ppm) with R(2) typically ca. 0.998. The RMS prediction error was found to be 0.10 ppm when the gel-colls were used for quantitative determination of unknown nicotine samples in 1-5 ppm level. The main advantages of the method are that the gel-colls constitute a highly stable and reproducible SERS medium that allows high throughput (50 sample h(-1)) measurements.  相似文献   

19.
 The method is based on catalysed ignition of a sample portion in a flow of oxygen, capture of mercury by an amalgamator and measurement of the mercury vapour's absorbance after thermic release from the amalgamator. Three powdered food samples, a certified reference material (CRM) human hair and a reference material (RM) urine (liquid) were measured in the first range of the instrument (the possible contents determined according to our measurement procedure were 0.0003–0.5 ppm). The calibration function used was a line passing through the origin. The combined standard uncertainties of the mercury determinations were computed from uncertainty components of five quantities: absorbance of the sample, absorbance of the sample blank, slope of the calibration line, correction factor of the abscissa axis, and mass or volume of the sample. The most important uncertainty component is the uncertainty of the sample absorbance measurement which amounts to 52% of the determination uncertainty at the minimum (RM urine) and about 90% at the maximum (in our laboratory homogenized powdered food samples; analysis of variance showed their homogeneity to be insufficient). The results of the CRM and RM analyses do not indicate a significant systematic error for this determination. The relative expanded uncertainty (coefficient was 2) of the determination increases from 9 to 13% for the insufficiently homogenized samples with decreasing mercury content (range of 0.004–0.03 ppm); higher homogeneity of samples results in a decrease of the expanded uncertainty, e.g. 4.6% for the liquid sample (RM urine). Received: 26 April 1999 / Accepted: 30 August 1999  相似文献   

20.
The present work describes a rapid, cost-effective analytical procedure for the determination of lead and cadmium in environmental samples by off-line preconcentration with polyurethane foam (PUF) functionalised with acetylacetone by covalent coupling through the–N=N–group. The optimum pH ranges for quantitative uptake were 5–7, 6–7 for lead and cadmium, respectively. The kinetics of metal uptake by the new foam was found to be fast, reaching equilibrium in a few minutes. Metal ions were sorbed in the minicolumn, eluted with acid solutions and determined by flame atomic absorption spectrometer (FAAS). Under the optimum conditions, the preconcentration factors obtained were 288 for Cd and 224 for Pb. The limits of detection of the proposed procedure were 0.09 and 0.07 µg L?1 for Pb and Cd, respectively. The relative standard deviation (RSD) was less than 10%. The accuracy of the method was estimated by using environmental samples that were spiked with Cd and Pb ions. The capacity of the acetylacetone bonded PUF (AA-BPUF) sorbent at optimum conditions has been found to be 4.5, 6.9 µmol g?1 of sorbent for Pb and Cd, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号