首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new Cu(II)-ion imprinted polymer (IIP) has been synthesized by copolymerizing salicylic acid and formaldehyde as a monomer and crosslinker, respectively in the presence of Cu(II)-4-(2-pyridylazo) resorcinol complex. The imprinted Cu(II) ions were completely removed by leaching the IIP with 0.05 M EDTA. The maximum adsorption capacity for Cu(II) ions was 310 μg g?1 at pH 6. The IIP was repeatedly used in adsorption–desorption experiments for seven times with recoveries ~95%. The relative selectivity factor (α r) values of Cu(II)/Zn(II), Cu(II)/Cd(II), Cu(II)/Ni(II) and Cu(II)/Co(II) are 3.17, 2.90, 2.47 and 3.37, respectively. The detection limit corresponding to three times the standard deviation of the blank was found to be 3.0 μg L?1. The developed IIP has also been tested for preconcentration and recovery of Cu(II) ions from water samples.  相似文献   

2.
A new Cu(II)-imprinted polymer has been prepared for selective solid-phase extraction of Cu(II) prior to its determination by flame atomic absorption spectrometry. Two functional monomers, 4-(methacryloylamino)benzamide and 4-vinylpyridine, formed a complex with Cu(II) ion through coordination interactions. The self-assembled Cu(II)-monomer complex was copolymerised via bulk polymerisation method in the presence of ethyleneglycoldimethacrylate cross-linker. In order to remove Cu(II) ions, the resulting polymer was washed with 1.0 M HNO3 and then with water until obtaining a neutral pH. The ion imprinted polymer was characterised by Fourier transform infrared. The experimental conditions were optimised for solid-phase extraction of Cu(II) using a column of ion-imprinted polymer (IIP). Quantitative retention was achieved between pH 5.0 and 7.0, whereas the maximum recovery for the non-imprinted polymer (NIP) was about 74% at pH 7.0. The IIP showed higher selectivity to Cu(II) in comparison to the NIP. The IIP also exhibited excellent selectivity for Cu(II) in the presence of other metal ions. The relative standard deviation and limit of detection (3s) of the method were 1.6% and 1.8 µg L?1, respectively. The method was verified by analysis of two certified reference materials (CWW-TM-D and SRM 3280) and then applied to the determination of Cu(II) in seawater and lake water samples and haemodialysis concentrates.  相似文献   

3.
Ion-imprinted polymer (IIP) particles are prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as crosslinking agent and 2,2′-azo-bis-isobutyronitrile as initiator in the presence of Cu(II), a Cu(II)-4-(2-pyridylazo)resorcinol (Cu(II)-PAR) complex, and PAR only. A batch procedure is used for the determination of the characteristics of the Cu(II) solid phase extraction from the IIP produced. The results obtained show that the Cu(II)-PAR IIP has the greatest adsorption capacity (37.4 μmol g−1 of dry copolymer) among the IIPs investigated. The optimal pH value for the quantitative preconcentration is 7, and full desorption is achieved by 1 M HNO3. The selectivity coefficients (SCu/Me) for Me = Ni(II), Co(II) are 45.0 and 38.5, respectively. It is established that Cu(II)-PAR IIPs can be used repeatedly without a considerable adsorption capacity loss. The determination of Cu(II) ions in seawater shows that the interfering matrix does not influence the preconcentration and selectivity values of the Cu(II)-PAR IIPs. The detection and quantification limits are 0.001 μmol L−1 (3σ) and 0.003 μmol L−1 (6σ), respectively.  相似文献   

4.
The present paper describes the feasibility of on-line preconcentration of nickel ions from aqueous medium on Ni(II)-imprinted cross-linked poly(methacrylic acid) (IIP) synthesised through a double-imprinting method and their subsequent determination by FAAS. The proposed method consisted in loading the sample (20.0 mL, pH 7.25) through a mini-column packed with 50 mg of the IIP for 2 min. The elution step was performed with 1.0 mol L?1 HNO3 at a flow rate of 7.0 mL min?1. The following parameters were obtained: quantification limit (QL) – 3.74 µg L?1, preconcentration factor (PF) – 36, consumption index (CI) – 0.55 mL, concentration efficiency (CE) – 18 min?1, and sample throughput – 25 h?1. The precision of the procedure assessed in terms of repeatability for ten determinations was 5.6% and 2.5% for respective concentrations of 5.0 and 110.0 µg L?1. Moreover, the analytical curve was obtained in the range of 5.0–180.0 µg L?1 (r = 0.9973), and a 1.64-fold increase in the method sensitivity was observed when compared with the analytical curve constructed for the NIP (non-imprinted polymer), thus suggesting a synergistic effect of the Ni(II) ions and CTAB on the adsorption properties of the IIP. The practical application of the adsorbent was evaluated from an analysis of tap, mineral, lake and river water. Considering the results of addition and recovery experiments (90.2–100 %), the efficiency of this adsorbent can be ensured for the interference-free preconcentration of the Ni(II) ions.  相似文献   

5.
A sensitive and simple method has been established for simultaneous preconcentration of trace amounts of Pb (II) and Ni (II) ions in water samples prior to their determination by flame atomic absorption spectrometry. This method was based on the using of a micro-column filled with graphene oxide as an adsorbent. The influences of various analytical parameters such as solution pH, adsorbent amount, eluent type and volume, flow rates of sample and eluent, and matrix ions on the recoveries of the metal ions were investigated. Using the optimum conditions, the calibration graphs were linear in the range of 7–260 and 5–85 μg L?1 with detection limits (3Sb) of 2.1 and 1.4 μg L?1 for lead and nickel ions, respectively. The relative standard deviation for 10 replicate determinations of 50 μg L?1 of lead and nickel ions were 4.1% and 3.8%, respectively. The preconcentration factors were 102.5 and 95 for lead and nickel ions, respectively. The adsorption capacity of the adsorbent was also determined. The method was successfully applied to determine the trace amounts of Pb (II) and Ni (II) ions in real water samples. The validation of the method was also performed by the standard reference material.  相似文献   

6.
In this study, an ion imprinted polymer (IIP) was prepared for the selective separation and preconcentration of trace levels of aluminum. Al(III) IIP was synthesized in the presence of Al(III)-8-hydroxyquinoline (oxine) complex using styrene and ethylene glycol dimethacrylate as a monomer and crosslinker, respectively. The imprinted Al(III) ions were completely removed by leaching the IIP with HCl (50 % v/v) and were characterized by FTIR and scanning electron microscopy. The maximum sorption capacity for Al(III) ions was found to be 3.1 mg g?1 at pH 6.0. Variables affecting the IIP solid phase extraction were optimized by the univariable method. Under the optimized conditions, a sample volume of 400 mL resulted in an enhancement factor of 194. The detection limit (defined as 3 S b/m) was found to be 1.6 μg L?1. The method was successfully applied to the determination of aluminum in natural water, fruit juice and cow milk samples.  相似文献   

7.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

8.

We demonstrate the application of an ionic liquid-based ferrofluid to the dispersive solid phase extraction of lead(II) using PAN as the chelator. The ionic liquid contains silica nanoparticles with a magnetic core as the dispersion medium, and its use results in improved stability of the colloidal dispersion and a complete extraction of lead(II) within a few seconds. In addition, there is no need for centrifugation. Specifically, the effect of different variables on the extraction of lead(II) was studied using an experimental design. Lead(II) was quantified by AAS. Under optimized conditions, the calibration graph for lead(II) is linear in the range from 5 to 372 μg L−1, the relative standard deviation is 1.34 % (for n = 7), the limit of detection is 1.66 μg L−1, and the enrichment factor is 200. The maximum adsorption capacity of sorbent was calculated to be 10.7 mg g−1, and adsorption follows a Langmuir isotherm.

A schematic view of D-SPE experimental set up. We demonstrate the application of an ionic liquid-based ferrofluid to the dispersive solid phase extraction of lead(II) using PAN as the chelator. The ionic liquid contains silica nanoparticles with a magnetic core as the dispersion medium

  相似文献   

9.
An amino acid derived ionic liquid, Fe3O4 nanoparticles and graphene oxide (GO) were used to prepare a material for the magnetic solid phase extraction (MSPE) of the ions Al(III), Cr(III), Cu(II) and Pb(II). The material was characterized by Fourier transform infrared spectral (FT-IR), scanning electron microscopy (SEM), thermal gravimetric analysis (TGA), magnetic analysis and isoelectric point (pI) analysis. It is shown to be a viable sorbent for the separation of these metal ions. Single factor experiments were carried out to optimize adsorption including pH values, ionic strength, temperature and solution volume. Following desorption with 0.1 M HCl, the ions were quantified by inductively coupled plasma optical emission spectrometry. Under the optimum conditions, the method provides a linear range from 10 to 170 μg· L?1 for Al(III); from 4.0 to 200 μg· L?1 for Cr(III); from 5.0 to 170 μg· L?1 for Cu(II); and from 5.0 to 200 μg· L?1 for Pb(II). The limits of detection (LOD) are 6.2 ng L?1 for Al(III); 1.6 ng L?1 for Cr(III); 0.52 ng L?1 for Cu(II); and 30 ng L?1 for Pb(II). Method performance was investigated by determination of these ions in (spiked) environmental water and gave recoveries in the range of 89.1%–117.8%.
Graphical abstract The graph shows that Al(III), Cr(III), Cu(II), Pb(II) are not adsorbed quantitatively by Fe3O4-SiO2. On the other hand, Cr(III) and Pb(II) are adsorbed quantitatively by Fe3O4-SiO2-GO while Al(III) and Cu(II) are not quantitatively retained. However, 3D–Fe3O4-SiO2-GO-AAIL adsorb all these 4 metal ions quantitatively.
  相似文献   

10.
This paper describes the synthesis and characterization of a fluorescent ion-imprinted polymer (IIP) for selective determination of copper ions in aqueous samples. The IIP has been prepared using a novel functional monomer, 4-[(E)-2-(4′-methyl-2,2′-bipyridin-4-yl)vinyl]phenyl methacrylate (abbreviated as BSOMe) that has been spectroscopically characterized in methanolic solution, in the absence and in the presence of several metal ions, including Cd(II), Cu(II), Hg(II), Ni(II), Pb(II), and Zn(II). The stability constant (2.04 × 108 mol−2 l2) and stoichiometry (L2M) of the BSOMe complex with Cu(II) were extracted thereof. Cu(II)-IIPs were prepared by radical polymerization using stoichiometric amounts of the fluorescent monomer and the template metal ion. The resulting cross-linked network did not show any leaching of the immobilized ligand allowing determination of Cu(II) in aqueous samples by fluorescence quenching measurements. Several parameters affecting optosensor performance have been optimized, including sample pH, ionic strength, or polymer regeneration for online analysis of water samples. The synthesized Cu(II)-IIP exhibits a detection limit of 0.04 μmol l−1 for the determination of Cu(II) in water samples with a reproducibility of 3%, exhibiting an excellent selectivity towards the template ion over other metal ions with the same charge and close ionic radius. The IIP-based optosensor has been repeatedly used and regenerated for more than 50 cycles without a significant decrease in the luminescent properties and binding affinity of the sensing phase.  相似文献   

11.
We describe a nanosized Cd(II)-imprinted polymer that was prepared from 4-vinyl pyridine (the functional monomer), ethyleneglycol dimethacrylate (the cross-linker), 2,2′-azobisisobutyronitrile (the radical initiator), neocuproine (the ligand), and Cd(II) (the template ion) by precipitation polymerization in acetonitrile as the solvent. The imprinted polymer was characterized by X-ray diffraction, thermogravimetric analysis, differential thermal analysis, and scanning electron microscopy. The maximum adsorption capacity of the nanosized sorbent was calculated to be 64 mg g?1. Cadmium(II) was then quantified by FAAS. The relative standard deviation and limit of detection are 4.2 % and 0.2 μg L?1, respectively. The imprinted polymer displays improve selectivity for Cd(II) ions over a range of competing metal ions with the same charge and similar ionic radius. This nanosized sorbent is an efficient solid phase for selective extraction and preconcentration of Cd(II) in complex matrices. The method was successfully applied to the trace determination of Cd(II) in food and water samples.
Figure
We describe a nanosized ion-imprinted polymer (IIP) for the selective preconcentration of Cd(II) ions. The nanosized-IIP was characterized by X-ray diffraction, Fourier transform IR spectroscopy, thermogravimetric and differential thermal analysis, and by scanning electron microscopy.  相似文献   

12.

Mercury exists in two forms in environment, inorganic salts and organic compounds. Determination of mercury is very important, due to its health effects. In the present research, diphenylation of mercury using phenylboronic acid as a derivatization reagent was used for the determination of Hg(II) in real water samples. A simple, rapid and cheap method named dispersive liquid–liquid microextraction was used for the extraction of analyte under the following conditions: extraction solvent 16 μL of carbon tetrachloride, disperser solvent 1 mL of ethanol and sample volume 5 mL. Under the optimal conditions, the enrichment factor for diphenylmercury was 931 and the limit of detection calculated on the basis of five replicates was 0.004 μg mL−1. The repeatability of the method expresses as relative standard deviation was 5.1 (n = 6). The linear range was between 0.01 and 10 μg mL−1. The performance of the proposed technique was evaluated for the determination of mercury in different environmental water samples.

  相似文献   

13.
Different metal-complexing ligands carrying synthetic adsorbents have been reported in the literature for heavy metal removal. We have developed a novel and new approach to obtain high metal adsorption capacity utilizing 2-methacrylamidohistidine (MAH) as a metal-complexing ligand. MAH was synthesized by using methacrylochloride and histidine. Spherical beads with an average size of 150–200 μm were obtained by the radical suspension polymerization of MAH and 2-hydroxyethylmethacrylate (HEMA) conducted in an aqueous dispersion medium. Owing to the reasonably rough character of the bead surface, p(HEMA-co-MAH) beads had a specific surface area of 17.6 m2 g−1. Synthesized MAH monomer was characterized by NMR. p(HEMA-co-MAH) beads were characterized by swelling studies, FTIR and elemental analysis. These p(HEMA-co-MAH) affinity beads with a swelling ratio of 65%, and containing 1.6 mmol MAH g−1 were used in the adsorption/desorption of copper(II) ions from metal solutions. Adsorption equilibria was achieved in ∼2 h. The maximum adsorption of Cu(II) ions onto pHEMA was ∼0.36 mg Cu(II) g−1. The MAH incorporation significantly increased the Cu(II) adsorption capacity by chelate formation of Cu(II) ions with MAH molecules (122.7 mg Cu(II) g−1), which was observed at pH 7.0. pH significantly affected the adsorption capacity of MAH incorporated beads. The observed adsorption order under non-competitive conditions was Cu(II)>Cr(III)>Hg(II)>Pb(II)>Cd(II) in molar basis. The chelating beads can be easily regenerated by 0.1 M HNO3 with higher effectiveness. These features make p(HEMA-co-MAH) beads very good candidate for Cu(II) removal at high adsorption capacity.  相似文献   

14.
A novel chelating resin (poly-Cd(II)-DAAB-VP) was prepared by metal ion imprinted polymer (MIIP) technique. The resin was obtained by one pot reaction of Cd(II)-diazoaminobenzene-vinylpyridine with cross-linker ethyleneglycoldimethacrylate (EGDMA). Comparing with non-imprinted resin, the poly-Cd(II)-DAAB-VP has higher adsorption capacity and selectivity for Cd(II). The distribution ratio (D) values for the Cd(II)-imprinted resin show increase for Cd(II) with respect to both D values of Zn(II), Cu(II), Hg(II) and non-imprinted resin. The relatively selective factor (αr) values of Cd(II)/Cu(II), Cd(II)/Zn(II) and Cd(II)/Hg(II), are 51.2, 45.6, and 85.4, which are greater than 1. poly-Cd(II)-DAAB-VP can be used at least 20 times without considerable loss of adsorption capacity. Based on poly-Cd(II)-DAAB-VP packed columns, a highly selective solid-phase extraction (SPE) and preconcentration method for Cd(II) from aqueous solution was developed. The MIIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.093 to 30 μg l−1. The detection limit and quantification limit were 0.093 and 0.21 μg l−1 (3σ) for flame atomic absorption spectrometry (FAAS). The relative standard deviation of the eleven replicate determinations was 3.7% for the determination of 10 μg of Cd(II) in 100 ml water sample. Determination of Cd(II) in certified river sediment sample (GBW 08301) demonstrated that the interfering matrix had been almost removed during preconcentration. The column was good enough for Cd(II) determination in matrixes containing components with similar chemical property such as Cu(II), Zn(II) and Hg(II).  相似文献   

15.
We have developed a fast method for sensitive extraction and determination of the metal ions silver(I), gold(III), copper(II) and palladium(II). Fe3O4 magnetic nanoparticles were modified with polythiophene and used for extraction the metal ions without a chelating agent. Following extraction, the ions were determined by flow injection inductively coupled plasma optical emission spectrometry. The influence of sample pH, type and volume of eluent, amount of adsorbent, sample volume and time of adsorption and desorption were optimized. Under the optimum conditions, the calibration plots are linear in the 0.75 to 100 μg L?1 concentration range (R2?>?0.998), limits of detection in the range from 0.2 to 2.0 μg L?1, and enhancement factors in the range from 70 to 129. Precisions, expressed as relative standard deviations, are lower than 4.2 %. The applicability of the method was demonstrated by the successful analysis of tap water, mineral water, and river water.
Figure
In the present work, polythiophene-coated Fe3O4 nanoparticles have been successfully synthesized and were applied as adsorbent for magnetic solid-phase extraction of some precious metal ions.  相似文献   

16.
Attapulgite modified with 2-hydroxy-1-naphthaldehyde was prepared and applied to the separation, preconcentration and determination of Cu(II) in aqueous solutions by inductively coupled plasma optical emission spectrometry. Experimental conditions for effective adsorption of trace levels of Cu(II) were optimized using batch and column procedures. The optimum pH value for the separation of Cu(II) on the newly sorbent was 4.0 and complete elution of Cu(II) from the sorbent surface was carried out using 2 mL of 0.01 mol L?1 HCl. The adsorption capacity for Cu(II) was 25.13 mg g?1. The detection limits of the method defined by IUPAC were found to be 0.24 μg L?1 with enrichment factor of 150. The method has been applied to the determination of Cu(II) in certified reference materials and natural water samples with satisfactory results.  相似文献   

17.
Longhua  Xu  Limin  Zhang  Xuguang  Qiao  Zhixiang  Xu  Jiaming  Song 《Chromatographia》2012,75(5-6):269-274

How to determine the quantities of acrylamide produced in foods is an important problem. Here, we report a sensitive method of high performance liquid chromatography based on a solid phase extraction using a reversed phase C18 column, which was characterized by adsorption experiments with good adsorption ability and rapid adsorption dynamic toward acrylamide. Under optimal condition, the detection limit based on three times the signal-to-noise ratio of the baseline near the analyte peak was 66.0 ng L−1. With a loading flow rate of 2.0 mL min−1 for loading 100 mL, an enrichment factor of 182 was obtained. The RSD for five replicate extractions of 50 μg L−1 acrylamide was 4.1%. Blank potato samples spiked with acrylamide at 0.125, 0.250, and 0.375 μg g−1 levels were analyzed with recoveries ranging from 88.9 to 89.5%. Moreover, this method was applied to quantitative detection of acrylamide in the crust and potato chip samples.

  相似文献   

18.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff.
Graphical abstract Compared with graphene, carbon nanotubes and carbon nanofibers, an electrode modified with fullerene in chitosan electrode displays superior performance for the simultaneous anodic stripping voltammetric detection of Hg(II), Cu(II), Pb(II) and Cd(II).
  相似文献   

19.
Solid-phase extraction (SPE) columns packed with materials based on molecularly imprinted polymers (MIPs) were used to develop selective separation and preconcentration for Ni(II) ion from aqueous solutions. SPE is more rapid, simple and economical method than the traditional liquid-liquid extraction. MIPs were used as column sorbent to increase the grade of selectivity in SPE columns. In this study, we have developed a polymer obtained by imprinting with Ni(II) ion as a ion-imprinted SPE sorbent. For this purpose, NI(II)-methacryloylhistidinedihydrate (MAH/Ni(II)) complex monomer was synthesized and polymerized with cross-linking ethyleneglycoldimethacrylate to obtain [poly(EGDMA-MAH/Ni(II))]. Then, Ni(II) ions were removed from the polymer getting Ni(II) ion-imprinted sorbent. The MIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.3 to 25 ng/ml and the detection limit was 0.3 ng/ml (3 s) for flame atomic absorption spectrometry (FAAS). Ni(II) ion-imprinted microbeads can be used several times without considerable loss of adsorption capacity. When the adsorption capacity of nickel imprinted microbeads were compared with non-imprinted microbeads, nickel imprinted microbeads have higher adsorption capacity. The Kd (distribution coefficient) values for the Ni(II)-imprinted microbeads show increase in Kd for Ni(II) with respect to both Kd values of Zn(II), Cu(II) and Co(II) ions and non-imprinted polymer. During that time Kd decreases for Zn(II), Cu(II) and Co(II) ions and the k′ (relative selectivity coefficient) values which are greater than 1 for imprinted microbeads of Ni(II)/Cu(II), Ni(II)/Zn(II) and Ni(II)/Co(II) are 57.3, 53.9, and 17.3, respectively. Determination of Ni(II) ion in sea water showed that the interfering matrix had been almost removed during preconcentration. The column was good enough for Ni determination in matrixes containing similar ionic radii ions such as Cu(II), Zn(II) and Co(II).  相似文献   

20.
The Cu (II) imprinted polymer glassy carbon electrode (GCE/Cu-IP) was prepared by electropolymerization of pyrrole at GCE in the presence of methyl red as a dopant and then imprinting by Cu2+ ions. This electrode was applied for potentiometric and voltammetric detection of Cu2+ ion. The potentiometric response of the electrode was linear within the Cu2+ concentration range of 3.9 × 10?6 to 5.0 × 10?2 M with a near-Nernstian slope of 29.0 mV decade?1 and a detection limit of 5.0 × 10?7 M. The electrode was also used for preconcentration anodic stripping voltammetry and results exhibited that peak currents for the incorporated copper species were dependent on the metal ion concentration in the range of 1.0 × 10?8 to 1.0 × 10?3 M and detection limit was 6.5 × 10?9 M. Also the selectivity of the prepared electrode was investigated. The imprinted polymer electrode was used for the successful assay of copper in two standard reference material samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号