首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Methods are described for the determination of trace and ultra trace amounts of Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb in natural waters, alkali and alkaline earth salts. Separation and preconcentration of trace metals is achieved by a column solid phase extraction procedure using silica gel modified with derivatives of dithiocarbamates — Na-DDTC (sodium diethyldithio-carbamate and HMDTC (ammonium hexamethylene-dithiocarbamate) as column packing material. The influence of the sorbent preparation procedure on the degree of sorption of the trace analytes is examined for different pH values of the sample solution. Isobutylmethyl ketone (IBMK) is proposed as an effective eluent for quantitative elution of retained metal ions. Optimal instrumental parameters for ETAAS determination of preconcentrated elements in organic eluate are presented. Practical application of sorbents in analysis of natural waters and alkali and alkaline earth salts is demonstrated. Proposed preconcentration procedure combined with ETAAS determination of trace analytes allows the determination of 0.04 g l–1 Cd, 0.1 g l–1 Cr, Cu, and Mn and 0.3 g l–1 Co, Fe, Ni and Pb in natural waters and 1.10–7% Cd, 3.10–7% Cr and Mn, 7.10–7% Co, Ni and Pb and 2.10–6% Cu and Fe in alkali and alkaline earth salts.  相似文献   

2.
Zusammenfassung Die Ionen des Cu, Pb, Cd, Zn, Fe und Mn in Pflanzenmaterial können mittels Differential-Puls-Polarographie ineinem Analysengang bestimmt werden, wenn man eine erste Grundlösung ohne Wechsel des Meßgefäßes durch Zusatz so variiert, daß jeweils eine andere Gruppe aus den genannten Ionen störungsfrei bestimmbar ist. Nach Veraschung und Lösung in Weinsäure lassen sich Cu, Pb, Cd und Zn, nach Zusatz von Ammoniak Cd, Zn und Fe, nach weiterem Zusatz von Kaliumcyanid Mn bestimmen. Benötigte Probenmenge 0,2–0,5 g, untere Bestimmungsgrenze um 1g/g. Die Methode eignet sich besonders für Serienanalysen. Ein Analysenbeispiel ist angegeben.
Simultaneous assay of Cu, Fe, Mn, Zn, Pb and Cd in plant tissue by means of differential pulse polarography
Summary Cu, Pb, Cd, Zn, Fe and Mn ions in plant material can be assayed by means of differential pulse polarography in one analysis operation if the first basic solution is varied without changing the measurement vessel by addition in such a way that in each case one other group of the named ions can be assayed without interference. After incineration and dissolution in tartaric acid, Cu, Pb, Cd and Zn can be assayed. After addition of ammonia Cd, Zn and Fe, and after further addition of potassium cyanide, Mn can be determined. Required sample amount: 0.2 to 0.5 g; lower limit of detection is around 1g/g. The method is especially suitable for serial analyses. An analysis example is given.
  相似文献   

3.
Summary The adsorption behaviour of ten metal complexes Cr(III), Cr(VI), Mn(II), Fe(II), Fe(III), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) with ferron on Zeo-Karb-226 in the H+ form was investigated at eight different pH-values in order to develop a preconcentration technique for trace amounts of these elements in aqueous solution. The concentrations of the remaining unadsorbed metal ions were determined by atomic absorption spectrophotometry. Under the present experimental conditions, Cr(III) and Pb(II) can be quantitatively determined within the pH range 4–8, while for Cd(II), the optimum pH-range is 7–11. But at pH 11, more than 95% of Cu(II) and Co(II) can be extracted from aqueous solution. The suitability of the technique has been evaluated by analyzing cadmium in simulated water samples. The results indicate that as low as 5 g 1–1 of CD can be recovered with more than 96% efficiency from 11 of simulated water solution.
Adsorptionsverhalten einiger Metallkomplexe mit Ferron an Zeokarb-226: eine AAS-Untersuchung
Zusammenfassung Das Adsorptionsverhalten der Komplexe von Cr(III), Cr(VI), Mn(II), Fe(II), Fe(III), Co(II), Ni(II), Cu(II), Cd(II) und Pb(II) mit Ferron an Zeokarb-226 in der H+-Form wurde bei acht verschiedenen pH-Werten untersucht, um eine Anreicherungsmethode für Spuren dieser Elemente zu entwickeln. Die Konzentrationen der verbliebenen nicht adsorbierten Metallionen wurden mit Hilfe der AAS bestimmt. Cr(III) und Pb(II) können im pH-Bereich 4–8 quantitativ erfaßt werden, während der optimale Bereich für Cd(II) bei pH 7–11 liegt. Bei pH 11 werden jedoch mehr als 95% Cu(II) und Co(II) aus der wäßrigen Lösung extrahiert. Der Nutzen des Verfahrens wurde durch Bestimmung von Cd(II) in simulierten Wasserproben erwiesen. Noch 5 g/l Cd können zu mehr als 96% aus 11 Wasserprobe wiedergefunden werden.
  相似文献   

4.
A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.  相似文献   

5.
Summary A correction method to diminish errors caused by different mass absorption coefficients of the samples is described. Also errors caused by differing device parameters are diminished. The method is used for the determination of Fe, Cr, Ni, Co, Mn, Zn, Cd, Cu, Hg and Pb on chemically modified silica in the g/g-range.
Anwendung einer Methode zur Matrixkorrektur durch Compton-Streupeaks für die quantitative Bestimmung von Metallen in Kieselgelen mit Hilfe der wellenlängendispersiven Röntgenfluorescenzanalyse (WDXRF)
Zusammenfassung Ein Korrekturverfahren zur Verminderung von Meßfehlern, die durch unterschiedliche Massenabsorptionskoeffizienten der Proben verursacht werden, wird beschrieben. Ebenso werden Fehler durch Schwankungen von Geräteparametern verringert. Die Methode wird benutzt zur Bestimmung von Fe, Cr, Ni, Cd, Co, Mn, Zn, Cu, Hg und Pb auf chemisch modifizierten Kieselgelen im g/g-Bereich.
  相似文献   

6.
Tokalioğlu S  Kartal S  Elçi L 《Annali di chimica》2002,92(11-12):1119-1126
A method was described for the determination of the elements Cr, Mn, Fe, Co, Ni, Cu, Cd, Pb, and Bi in waters by flame atomic absorption spectrometry (FAAS) after separation and preconcentration on Amberlite XAD-16 resin with sodium tetraborate using a chromatographic column. Parameters influencing the analytical performance, including pH and the volume of sample, amount of analyte and interfering effect of co-existing ions, were studied in detail. The recovery values were quantitative (> or = 95%), and the relative standard deviation (RSD) and detection limit (DL) varied in the range of 1.1-2.4% (n=10) and 0.002-0.177 microg m(-1) (3s, n=20), respectively. After being optimized, the proposed method was applied to the drinking water, waste water and artificial sea water samples. Recovery values of the elements investigated, were quantitative for tap water and synthetic sea water, except for Mn, Co and Ni (including also Cd for synthetic sea water). Recovery values of Cd, Pb, Cu and Co were found to be 95, 102, < or = 87, and < or = 83%, respectively, for the waste water samples.  相似文献   

7.
Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL–1 and pg mL–1 level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/m=300), medium (MR, m/m=3,000) and high (HR, m/m=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum–maximum in ng mL–1) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004–0.0018, As 0.69–1.32, Cd 0.031–0.096, Co 0.018–0.065, Cr 0.18–0.46, Cu 0.04–1.58, Fe 0.13–1.63, Mn 0.02–0.12, Mo 5.97–12.46, Pb 0.007–0.074, Sb 0.033–0.088, U 0.5–1.9, V 0.6–2.5 and Zn 0.16–0.80. Concentration ranges (min–max in ng mL–1) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24–0.61, Ag 0.007–0.031, As 1.42–2.27, Cd 0.050–0.182, Co 0.440–1.461, Cr 0.15–0.34, Cu 0.81–2.46, Fe 0.25–1.66, Mn 11.6–31.7, Mo 6.50–10.6, Pb 0.047–0.225, Sb 0.240–0.492, U 1.7–3.3, V 1.3–2.8 and Zn 5.20–21.5. The detection limits range between 0.06 pg mL–1 for Ag and U to 15 pg mL–1 for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.  相似文献   

8.
A coprecipitation method has been developed for the determination of Cr(III), Mn(II), Fe(III), Co(II), Cu(II), Cd(II) and Pb(II) ions in aqueous samples by flame atomic absorption spectrometry (FAAS) with the combination of pyridine, nickel(II) as a carrier element and potassium thiocyanate as an auxiliary complexing agent. The obtained coprecipitates were dissolved with nitric acid and measured by FAAS. The coprecipitation conditions, such as the effect of the pH, amounts of nickel, pyridine and potassium thiocyanate, sample volume, and the standing time of the precipitate formation were examined in detail. It was found that the metal ions studied were quantitatively coprecipitated with tetrakis(pyridine)-nickel(II)bis(thiocyanate) precipitate (TP-Ni-BT) in the pH range of 9.0 - 10.5. The reliability of the results was evaluated by recovery tests, using synthetic seawater solutions spiked with the analyte metal ions. The obtained recoveries ranged from 96 to 101% for all of the metal ions investigated. The proposed method was validated by analyses of two certified reference materials (NIST SRM 2711 Montana soil and HPS Certified Waste Water Trace Metals Lot #D532205). It was also successfully applied to seawater and dialysis solution samples. The detection limits (n = 25, 3s) were in the range of 0.01-2.44 microg l(-1) for the studied elements and the relative standard deviations were < or =6%, which indicated that this method could fully satisfy the requirements for analysis of such samples as seawater and dialysis solution having high salt contents.  相似文献   

9.
A column, solid-phase extraction (SPE), preconcentration method was developed for determination of Bi, Cd, Co, Cu, Fe, Ni and Pb ions in drinking water, sea water and sediment samples by flame atomic absorption spectrometry. The procedure is based on retention of analytes in the form of pyrrolidine dithiocarbamate complexes on a short column of Chromosorb-102 resin from buffered sample solution and then their elution from the resin column with acetone. Several parameters, such as pH of the sample solution, amount of Chromosorb-102 resin, amount of ligand, volume of sample and eluent, type of eluent, flow rates of sample and eluent, governing the efficiency and throughput of the method were evaluated. The effects of divers ions on the preconcentration were also investigated. The recoveries were >95%. The developed method was applied to the determination of trace metal ions in drinking water, sea water and sediment samples, with satisfactory results. The 3σ detection limits for Cd, Cu, Fe, Ni and Pb and were found to be as 0.10, 0.44, 11, 3.6, and 10 μg l−1, respectively. The relative standard deviation of the determination was <10%. The procedure was validated by the analysis of a standard reference material sediment (GBW 07309) and by use of a method based on coprecipitation.  相似文献   

10.
Summary The analytical performance of an on-line oxine-cellulose microcolumn preconcentration system coupled to simultaneous ICP was investigated. Different factors including the pH of the sample solution, the flow rates of sample loading and eluation, the acidity of eluent and different eluents were investigated and optimized. In comparison with continuous aspiration, the signal enhancement factors of eleven elements (Zn, Cu, Ni, V, Cr, Fe, Mn, Co, Pb, Cd and Al) were in the range of 6.4 to 13.5 for peak height (0.5 s) and 3.7 to 5.8 for peak area (15 s), respectively. The influences of matrix ions, such as Ca, Mg, Fe, Cu and NaCl were studied. Performance was demonstrated by simultaneous determination of seven (Zn, Cu, Ni, V, Cr, Fe, Mn) elements in a number of CRMs. Most results were satisfactory, except for iron and chromium. The possible reasons were discussed. Co, Pb, Cd and Al were not available in the simultaneous instrument. Therefore, only the analytical performance was measured for these elements by the sequential instrument.On leave from Shanghai Institute of Metallurgy, Academia Sinica, Shanghai, China 200050  相似文献   

11.
Yttrium hydroxide quantitatively coprecipitated Be(II), Ti(IV), Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) at pH 9.6 - 10.0 for seawater and pH 10.5 - 11.4 for a table-salt solution. The coprecipitated elements could be determined by inductively coupled plasma atomic emission spectrometry; yttrium was used as an internal standard element. The detection limits ranged from 0.001(6) microg (Mn(II)) to 0.22 microg (Zn(II)) in 100 mL of sample solutions. The operation time required to separate 11 elements was approximately 30 min.  相似文献   

12.
A sol-gel zirconia coating was developed for the preconcentration/separation of trace Cr, Cu, Cd and Pb by capillary microextraction, and the adsorbed analytes were on-line eluted for detection using inductively coupled plasma mass spectrometry (ICP-MS). By immobilizing sol-gel zirconia on the inner surface of a fused-silica capillary, the sol-gel zirconia coating was simply prepared. Its adsorption properties, stability and the factors affecting the adsorption behaviors of Cr, Cu, Cd and Pb were investigated in detail. In the pH range from 7.8 to 10, the zirconia-coated capillary (35 cm x 0.15 mm) is selective towards Cr, Cu, Cd and Pb, and the analyzed ions could be desorbed quantitatively with 0.2 mL of 0.5 mol/L HNO(3) at a rate of 0.2 mL/min. With a consumption of 1.25 mL sample solution, an enrichment factor of 6.25, and detection limits (3sigma) of 9.9 pg/mL Cr, 17.9 pg/mL Cu, 4.5 pg/mL Cd and 3.7 pg/mL Pb were obtained. The precisions for nine replicate measurements of 1 ng/mL Cr, Cu, Cd and Pb were 4.9% Cr, 2.2% Cu, 2.0% Cd and 3.2% Pb (RSD), respectively. The proposed procedure has been applied to the determination of Cr, Cu, Cd and Pb in human urine, which was subjected to microwave-assisted digestion prior to analysis, and the recoveries for these elements were 89.2-101.8%. In order to validate the developed procedure, a NIES No.10-a Rice Flour-Unpolished certified reference material and a BCR No. 184 Bovine Muscle certified reference material were analyzed, and the results are in good agreement with the certified values.  相似文献   

13.
《Analytical letters》2012,45(3):442-452
A procedure for the determination of trace levels of Cd, Co, Cr, Fe, Mn, Ni, and Pb by flame atomic absorption spectrometry using a column preconcentration system is described in which the metals were adsorbed on pulverized banana peel, an economically and environmentally acceptable sorbent. In the optimization procedure, five variables (sample pH, mass of biosorbent, type of eluent, sample flow rate, and volume) were optimized and the capacity of the biosorbent was established. Under the optimized conditions, the detection limits of the method were 2.4, 27.0, 49.4, 31.1, 6.7, 29.6, and 46.2 µg L?1 for Cd, Co, Cr, Fe, Mn, Ni, and Pb, respectively. The precision, expressed as relative standard deviation, was less than 4% based on twelve measurements. The recoveries were 81.1% (Cd), 91.4% (Co), 87.2% (Cr), 90.1% (Fe), 88.0% (Mn), 94.1% (Ni), and 93.2% (Pb) under the optimum conditions (pH; 9, sample flow rate; 3 mL min?1, mass of biosorbent; 200 mg; eluent; 1 mol L?1 nitric acid, preconcentration factor; 10). The sorption capacity of pulverized banana peel was 15.12, 28.85, 32.70, 30.44, 30.94, 28.97, and 8.21 µmol per gram of adsorbent for Cd, Co, Cr, Fe, Mn, Ni, and Pb, respectively.  相似文献   

14.
A multiwalled carbon nanotube disk was used for the SPE of some toxic heavy metals from environmental samples. Metal ions were adsorbed on the disk as 8-hydroxquinoline complexes, then quantitatively desorbed from the disk by using 10 mL 2 M HNO3. The effects of analytical parameters, including pH, sample volume, and flow rates, on the recoveries of Cd(II), Co(II), Ni(II), Pb(II), Fe(III), Cu(II), and Zn(II) were investigated. The influences of some 1A and 2A group elements and some other ions as concomitant ions on the recoveries of analyte ions were also examined. The LODs of the presented preconcentration-separation system for the analyte ions were found to be in the range of 1.0-5.2 microg/L. In order to validate the procedure, SRM 1577B Bovine Liver, IAEA 336 Lichen, and HR-1 Humber river sediment certified reference materials were analyzed. The proposed method has been applied to the determination of understudy elements in some pharmaceutical samples and natural water samples from different sites in Turkey.  相似文献   

15.
Concentrations of Ag, Ba, Cd, Ce, Cs, Co, Cr, Eu, Fe, Rb, Sc, Sr, Th, and Zn exchangeable fractions were determined in alluvial sediments at waste disposal site area in the vicinity of water-well field. Samples have been leached with 0.5M NH4Cl at a sample/solution ratio of 120 during 24 hours without shaking. INAA of dry NH4Cl residues show that the concentrations of exchangeable elements determined in the most of the sediments below the wastes have natural levels. Ag, Ba and Sr are readily exchangeable; Rb, Cs and Zn have lower exchangeability, while Cd, Ce, Th, Sc, Eu, Cr, Fe and Co are rather immobile. Extremely high total and exchangeable silver concentration was found at 6.5–6.8 meters below waste in the aerated layer occasionally under the water table. Exchangeable concentrations in deeper water-bearing sediment layers are not elevated. Due to this, one can presume that the upper sediment layers act as chemical filter generally preventing the infiltration from overlying wastes into water-bearing layers.  相似文献   

16.
Preconcentration/separation of Co(II), Fe(III), Pb(II), Cr(III), Cu(II) and Cd(II) ions using bis(5‐bromo‐2‐hydroxy‐benzaldehyde)‐2‐methyl‐1,5‐pentane diimine (BBHBPDI) on SDS coated alumina has been reported. The influences of the analytical parameters including pH, ligand and SDS amount, type and concentration of eluent and sample volume on metal ions recoveries were investigated. At optimum values of all variables the relative standard deviation are between 2.5–2.7 and preconcentration factor was 375, while recoveries for all understudy metal ions are higher than 95%, determination limits are between 1.5–2.7. The method has been successfully applied to determination of Co(II), Fe(III), Pb(II), Cr(III), Cu(II) and Cd(II) ions content in some real samples.  相似文献   

17.
We report on a study on the retention and elution of ions of the precious metals Au, Ir, Pd, Pt, Rh and Ru, sometimes in the presence of ions of the nonprecious elements Co, Cu, Fe, Ni, Pb and Te. A commercial cyano-modified microparticle-based solid phase was used as a sorbent and hydrochloric acid in various concentrations for sample solution and elution. Only Au and Pd (in the form of their chloro complexes) were retained, and Au is found to have a much higher affinity for the sorbent compared to Pd. In addition to the affinity of the metal towards the functional groups, the retention behavior of the precious metals seems to be mainly influenced by steric factors of their respective chloro complexes. Elution with 7.5 M HCl does not require the addition of organic eluent as required in other cases. The method can separate Au or both Au and Pd, from hydrochloric acid solutions containing ions of other precious metals or nonprecious elements. The sorbent was applied to recover gold from a mineral digest containing large amounts of metals such as Fe, Pb, Te, Cu, Ni and Zn.
Fig
Percentage of the precious metals retained on the CN sorbent from various concentration of HCl solution. Sample volume: 10 mL, Sorbent mass: 500 mg, Concentration of sample solution: 5 μg?·?mL?1 of each metal. Each bar is the average of three extractions. The percent error is in the range of 1.8–3.6 %.  相似文献   

18.
The conditions for the flow determination of Al(III), Bi(III), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Nd(III), Ni(II), Pb(II), Pr(III), and Zn(II) by reaction with Xylenol Orange in aqueous solutions at pH 4.5 and the determination of Cd(II), Co(II), Cu(II), Fe(II), Ni(II), Pb(II), and Zn(II) by reaction with 4-(2-thiazolylazo)resorcinol in water–ethanol mixtures (5 : 1) at pH 5.0 using an injected sample volume of 80 L were proposed. The limits of detection were n × 10–8n × 10–7 mol/L; the linearity ranges in the calibration graphs were of about three orders of magnitude; the relative standard deviation was of 3–7%.  相似文献   

19.
A silica-based inorganic sorbent was synthesized by the thermal decomposition of ammonium heptamolybdate on silica and applied for the preconcentration and simultaneous determination of Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb in river water samples using a column system with flame atomic absorption spectrometry. Attenuated total reflection-Fourier transformation infrared spectroscopy, scanning electron microscopy, and electron dispersive spectroscopy were used for sorbent characterization. The effects of pH, sample volume, eluent type, eluent concentration, eluent volume, sample flow rate, and matrix ions (Al, Bi, Ca, Mg, and Zn) on the recovery of the metals in model solutions were investigated. The adsorption capacities (µmol g?1) of SiO2-MoO3 were 88.96 (Cd), 169.69 (Co), 153.85 (Cr), 188.88 (Cu), 179.05 (Fe), 163.81 (Mn), 136.31 (Ni), and 38.61 (Pb). The detection limits of the method were 9.09, 10.82, 10.77, 49.57, 31.64, 6.40, 8.86, 19.15?µg L?1 for Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb, respectively, with a preconcentration factor of 25. The developed method was used for the determination of the target metals in real samples and the recoveries for spiked samples were found to be from 91.2% to 102.9%.  相似文献   

20.
Summary Procedures for the analysis of titanium metal after dissolution in HF and HNO3 are described. The 3 -detection limits (DL) for the determination with sequential AES in solutions of 1% titanium are about 100 ng/mL for many analytes. Investigation of the matrix interferences shows that removal of the matrix by one decade to 0.1% Ti improves DL by about 2–3 decades. Using the chelating ion exchanger Cellulose-HYPHAN in combination with hexamethylene dithiocarbamidate (HMDC) in a batch technique, the enrichment rate for the analytes Cu, Fe, Ni, Pb and V is better than 88%. Furthermore the elements Cd, Co and Zn are enriched if Chelex 100 is used in the batch mode. In a column technique 17 elements (Ag, Al, Ba, Ca, Cd, Co, Cu, Fe, Ga, In, Mg, Mn, Ni, Sn, Th, V, Zn) can be determined with enrichment rates better than 89%. Pb and Sr are collected by about 70%. Detection limits of about 1 to 10 ng/mL in the solution can be achieved (dilution factor of the metal sample about 20).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号