首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A novel, sensitive and selective adsorptive stripping procedure for simultaneous determination of iron, copper and cadmium is presented. The method is based on the adsorptive accumulation of thymolphthalexone (TPN) complexes of these elements onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the simultaneous determination of iron, copper and cadmium were studied using the Derringer desirability function. The optimum analytical conditions were found to be TPN concentration of 2.0 μM, pH of 9.5, and accumulation potential at ?0.4 V vs. Ag/AgCl with an accumulation time of 60 s. The peak currents are proportional to the concentration of iron, copper and cadmium over the 1–80, 0.5–100 and 1–100 ng mL?1 ranges with detection limits of 0.5, 0.4 and 0.9 ng mL?1, respectively. The R.S.D. at a concentration level of 20 ng mL?1 of iron, copper and cadmium were 2.5%, 0.9% and 1.5% (n=6), respectively. The procedure was applied to the simultaneous determination of iron, copper and cadmium in the tap water and some synthetic samples with satisfactory results.  相似文献   

2.
N‐Phenylanthranilic acid was used as a complexing agent for determination of uranium(VI) by adsorptive cathodic stripping voltammetry. Under the optimal experimental conditions of the experimental parameters, the peak current was proportional to the concentration of U(VI) in the range 0.75–30 ng mL?1 and the detection limit was 0.036 ng mL?1. The influence of possible interferences was investigated. The method was applied for determination of uranium in waste water from uranium conversion facility and natural water samples. Application of the method for simultaneous determination of U(VI) and Cu(II) showed that these ions could be simultaneously determined in a single scan at relatively wide concentration range.  相似文献   

3.
This research introduces the design of an adsorptive stripping voltammetric method for the cerium(III) determination at a carbon paste electrode, chemically modified with dipyridyl‐functionalized nanoporous silica gel (DPNSG‐CPE). The electroanalytical procedure comprised two steps: the Ce(III) chemical accumulation at ?200 mV followed by the electrochemical detection of the Ce(III)/dipyridyl complex, using anodic stripping voltammetry. The factors, influencing the adsorptive stripping performance, were optimized including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The resulting electrode demonstrated a linear response over a wide range of Ce(III) concentration (1.0–28 ng mL?1). The precision for seven determinations of 4 and 10 ng mL?1 Ce(III) was 3.2% and 2.5% (relative standard deviation), respectively. The prepared electrode was used for the cerium determination in real samples and very good recovery results were obtained.  相似文献   

4.
A novel, simple and sensitive adsorptive stripping voltammetry method was developed for simultaneous determination of Cd and Zn using N‐Nitrozo‐N‐phenylhydroxylamine (Cupferron) as a selective complexing agent. Cadmium and zinc metals gave peaks that were distinctly separated by 450–1200 mV, allowing their determination over a wide range of concentrations. The influence of pH and the nature of supporting electrolytes, concentration of ligand, preconcentration time and applied potential were investigated. The detection limits were 0.058 ng/mL for Zn and 0.092 ng/mL for Cd, and the RSD at a concentration level of 50 ppb, were 1.8–2.1 % for both zinc and cadmium, respectively. The method was applied to the determination of cadmium and zinc in blood, drug, food and water samples with the satisfactory results.  相似文献   

5.
A sensitive adsorptive cathodic stripping voltammetry with H‐point standard addition method for simultaneous determination of uranium and cadmium has been developed. The trace amounts of these metal ions can be simultaneously determined using the Levodpa as complexing agent. Optimal conditions were: accumulation time 50 s, accumulation potential 0.0 mV, scan rate 40 mV s?1, supporting electrolyte 0.1 M ammonium buffer pH 9.6, and 1×10?5 M of Levodopa. The results revealed that the cadmium and uranium could be simultaneously determined by H‐point standard addition method with different concentration ratios of uranium to cadmium. The method was successfully applied in a several of real samples.  相似文献   

6.
A new adsorptive anodic differential pulse stripping voltammetry method for the direct determination of noscapine at trace levels in human plasma of addicts is proposed. The procedure involves an adsorptive accumulation of noscapine on a hanging mercury drop electrode (HMDE), followed by oxidation of adsorbed noscapine by voltammetry scan using differential pulse modulation. The optimum conditions for the analysis of noscapine are pH = 8.5 using Britton‐Robinson (B‐R) buffer, accumulation potential of ?100 mV (vs. Ag/AgCl), and accumulation time of 150 s. The peak current is proportional to the concentration of noscapine, and a linear calibration graph is obtained at 0.015–2.75 μg mL?1. A relative standard deviation of 1.28% (n = 5) was obtained, and the limit of detection was 7 ng mL?1. The capability of the method for the analysis of real samples was evaluated by determination of noscapine in spiked human plasma and addicts, human plasma with satisfactory results.  相似文献   

7.
An adsorptive differential pulse stripping method for the simultaneous determination of lead and tin is proposed. The procedure involves an adsorptive accumulation of lead and tin on a hanging mercury drop electrode (HMDE), followed by oxidation of adsorbed lead and tin by voltammetric scan using differential pulse modulation. The optimum experimental conditions are: 0.2 mol L?1 HNO3, accumulation potential of ?900 mV versus Ag/AgCl, accumulation time of 200 s, scan rate of 20 mV s?1 and pulse height of 80 mV. Lead and tin peak currents were observed in the same potential region at about ?400 mV. The simultaneous determination of lead and tin by using voltammetry is a difficult problem in analytical chemistry, due to voltammogram interferences. The resolution of a mixture of lead and tin by the application of orthogonal signal correction‐partial least squares (OSC‐PLS) was performed. The linear dynamic ranges were 0.003‐0.35 and 0.008‐0.50 μg mL?1 and detection limits were land 3 ng mL?1 for lead and tin, respectively. The RMSEP for lead and tin with OSC and without OSC were 2.8737, 6.0557 and 8.0941, 9.5151, respectively. The capability of the method for the analysis of real samples was evaluated by the determination of lead and tin in water samples with satisfactory results.  相似文献   

8.
A second‐derivative spectrophotometric method based on zero‐crossing over technique is developed in simultaneous determination of copper(II) and nickel(II) ions. Methylthymol blue (MTB) as a chromogenic reagent and cetyltrimethylammonium bromide as a surfactant were used, and measurements were carried out in buffered solution at pH 6 and at a temperature of 25 °C. The amplitude of derivative spectra was measured at wavelengths of 631.9 and 587.7 nm for the simultaneous determination of Ni2+ and Cu2+, respectively. Linearity was obtained in the range of 0.5–5.0 μg mL?1 for both ions in the presence of 0.0–5.0 μg mL?1 of the other ion as an interfering ion. IUPAC detection limits for Cu2+ and Ni2+ ions were obtained at 0.48 and 0.43 μg mL?1, respectively. The proposed procedure has been applied successfully for the simultaneous determination of copper and nickel in synthetic binary mixtures and real samples.  相似文献   

9.
《Electroanalysis》2005,17(8):719-723
A very sensitive and selective adsorptive cathodic stripping procedure for trace measurement of uranium is presented. The method is based on adsorptive accumulation of the uranium‐pyromellitic acid (benzene‐1,2,4,5‐tetracarboxylic acid) complex onto a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. Influences of effective parameters such as pH, concentration of pyromellitic acid, accumulation potential and accumulation time on the sensitivity were studied. The peak current was proportional to the concentration of U(IV) up to 40 ng mL?1 with a limit of detection of 0.136 ng mL?1 with an accumulation time of 120 s. The range of linearity enhanced to 71.4 ng mL?1and the detection limit improved to 0.058 ng mL?1with accumulation times of 60 s and 300 s respectively. The relative standard deviation for 10 replicate determination of 4.76 ng mL?1 U(IV) was equal to 2.7%. The possible interference by major cations and anions are investigated. The method was applied to the determination of uranium in some analytical grade salts, seawater and in synthetic samples corresponding to some uranium alloys with satisfactory results.  相似文献   

10.
A novel, sensitive and selective adsorptive stripping procedure for determination of aluminum is presented. The method is based on the adsorptive accumulation of dithiooxamide (Rubeanic acid) complex of aluminum onto a hanging mercury drop electrode, followed by reduction of adsorbed species by voltammetric scan using differential pulse modulation. The influences of control variables on the sensitivity of the proposed method for the determination of aluminum were studied. The optimum analytical conditions were found to be Rubeanic acid (RA) concentration of 8.0×10?5 M, ammonia buffer (NH3? NH4Cl) pH of 6.5, and accumulation potential at ?50 mV vs. Ag/AgCl with an accumulation time of 60 s. The peak currents are proportional to the concentration of aluminum over the 0.3–70 ng mL?1 ranges with detection limit of 0.012 ng mL?1. The procedure was applied to the determination of aluminum in the Lab. Water, HCl of Merck and potato samples with satisfactory results.  相似文献   

11.
A glassy carbon electrode was modified with carbon nanotubes and the ionic liquid N‐butyl pyridinium trifluoromethyl methanesulfonate for the determination of methyldopa in urine samples. Methyldopa exhibited a well‐defined anodic signal over a broad pH range of 2–10 and the peak current increased approximately 100 fold over that of the unmodified electrode. Accordingly, a novel method for the determination of methyldopa was proposed using differential pulse voltammetry. The peak current was linear over a methyldopa concentration range from 21 to 2111 ng mL?1 with a LOD of 6.9 ng mL?1 and a LOQ of 7.4 ng mL?1. The method was applied to determine the excretion profile of methyldopa in urine without sample pretreatment.  相似文献   

12.
A poly(4‐vinylpridine‐co‐ethylene glycol dimethacrylate) monolith was synthesized in a capillary and constructed as a concentrator for the in‐line polymeric monolith microextraction coupling with capillary electrophoresis. The integrated system was then used for the simultaneous determination of five trace phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) in water samples. The experimental parameters for in‐line solid‐phase extraction, such as composition and volume of the elution plug, pH of sample solution, and the time for sample loading were optimized. The sensitivity for the mixture of phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) enhanced to 615–2222 folds at the optimum condition was compared to the sensitivity for a normal hydrodynamic injection in capillary electrophoresis. Linearity ranged from concentration of 10–500 ng mL?1(R2 > 0.999) for all five phenols with the detection limits of 1.3–3.3 ng mL?1. In tap, snow and Yangtze River water spiked with 20 ng mL?1 and 200 ng mL?1, respectively, the recoveries of 84–105% were obtained. It has been demonstrated that this work has great potential for the analysis of phenols in genuine water samples.  相似文献   

13.
A new method is described for the determination of lead based on the cathodic adsorptive stripping of the lead–nuclear fast red (NFR) at a carbon paste electrode (CPE). The differential pulse voltammograms of the adsorbed complex of lead–NFR are recorded from ?0.10 to ?0.60 V (versus Ag/AgCl electrode). Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, 4.0×10?5 mol L?1 NFR; buffer solution (pH of 3.0), accumulation potential and time, ?0.20 V, 60 and 120 s (for high and low concentration of lead), respectively. The results show that the complex can be adsorbed on the surface of the CPE, yielding one peak at ?0.34 V, corresponding to reduction of NFR in the complex at the electrode. The detection limit was found to be 0.2 ng mL?1 with a 120s accumulation time. The linear ranges are from 0.5 to 50 (tacc=120 s) and 50 to 200 ng mL?1 (tacc=60 s). Application of the procedure to the determination of lead in lake water, bottled mineral water, synthetic samples and sweet fruit‐flavored powder drinks samples gave good results.  相似文献   

14.
The well‐known method for the determination of mercury(II), which is based on the anodic stripping voltammetry of mercury(II), has been adapted for applications at the thin film poly(3‐hexylthiophene) polymer electrode. Halide ions have been found to increase the sensitivity of the mercury response and shift it more positive potentials. This behavior is explained by formation of mercuric halide which can be easily deposited and stripped from the polymer electrode surface. The procedure was optimized for mercury determination. For 120 s accumulation time, detection limit of 5 ng mL?1 mercury(II) has been observed. The relative standard deviation is 1.3% at 40 ng mL?1 mercury(II). The performance of the polymer film studied in this work was evaluated in the presence of surfactants and some potential interfering metal ions such as cadmium, lead, copper and nickel.  相似文献   

15.
《Analytical letters》2012,45(12):1999-2013
Abstract

A simple, rapid, selective, and sensitive method for the derivative spectrophotometric determination of Hg(II) and its simultaneous determination in the presence of Zn(II) using 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol in the presence of cetylpyridinium chloride, a cationic surfactant, has been developed. The molar absorption coefficient and analytical sensitivity of the 1∶1 Hg(II) complex at 558 nm (λmax) are 5.78×104 L mol?1 cm?1 and 0.67 ng mL?1, respectively. The detection limit of Hg(II) is 1.40×10?2 ng mL?1, and Beer's law is valid in the concentration range 0.05–2.40 µg mL?1. Overlapping spectral profiles of Hg(II) and Zn(II) complexes in zero‐order mode interfere in their simultaneous determination. However, 0.10–2.00 µg mL?1 of Hg(II) and 0.065–0.650 µg mL?1 of Zn(II), when present together, can be simultaneously determined at zero cross point of the derivative spectrum, without any prior separation. The relative standard deviation for six replicate measurements of solutions containing 0.134 µg mL?1 of Hg(II) and 0.620 µg mL?1 of Zn(II) is 1.72 and 1.47%, respectively. The proposed method has successfully been evaluated for trace level simultaneous determination of Hg(II) and Zn(II) in environmental samples.  相似文献   

16.
A method for the determination of nickel(II) by stripping voltammetry is described. The method is based on the adsorptive accumulation of nickel(II) calconcarboxylic acid complex onto a hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed complex using differential pulse voltammetry. The optimum operating conditions and parameters were found to be 0.05 M NH3/NH4Cl buffer (pH = 9.5) as the supporting electrolyte, a ligand concentration of 1 × 10?6 M, accumulation potential of ?0.5 V (vs. Ag/AgCl) and accumulation time of 60 s. At the optimized conditions, the peak current is proportional to the concentration of nickel in the range of 1.7 × 10?9 to 4.7 × 10?7 M (0.1–28 ng ml?1) with a detection limit of 0.05 ng ml?1. The relative standard deviation (n = 10) at nickel concentrations of 2, 10 and 15 ng ml?1 varies in the range 0.76 to 2.1%. Possible interferences by metal ions, which are of great significance in real matrices, have been studied. The method was successfully applied to the determination of nickel content in a chocolate sample.  相似文献   

17.
《Analytical letters》2012,45(6):1159-1169
Abstract

A new adsorptive cathodic differential pulse stripping voltammetry method for the direct determination of lorazepam at trace levels in pharmaceutical formulations and biological fluids is proposed. The procedure involves an adsorptive accumulation of lorazepam on a hanging mercury drop electrode (HMDE), followed by reduction of adsorbed lorazepam by voltammetric scan using differential pulse modulation. The optimum conditions for the analysis of lorazepam are pH=2 using Britton‐Robinson (B‐R) buffer, accumulation potential of ?0.2 V (vs. Ag/AgCl), and accumulation time of 40 sec. The peak current is proportional to the concentration of lorazepam, and a linear calibration graph is obtained at 0.05–1.15 µg mL?1. A relative standard deviation of 2.41% (n=3) was obtained, and the limit of detection was 0.019 µg mL?1. The capability of the method for the analysis of real samples was evaluated by determination of lorazepam in pharmaceutical preparations and biological (urine and plasma) fluids with satisfactory results.  相似文献   

18.
A porous carbon designated as MOF‐5‐C was prepared by directly carbonizing a metal–organic framework (MOF‐5). The morphology and microstructure of MOF‐5‐C were characterized by scanning electron microscopy, N2 adsorption, and powder X‐ray diffraction. The MOF‐5‐C retained the original porous structures of MOF‐5, and showed a high Brunauer–Emmett–Teller surface area (1808 m2 g?1) and large pore volume (3.05 cm3 g?1). To evaluate its adsorption performance, the MOF‐5‐C was used as an adsorbent for the solid‐phase extraction of four phthalate esters from bottled water, peach juice, and soft drink samples followed by high‐performance liquid chromatographic analysis. Several parameters that could affect the extraction efficiencies were investigated. Under the optimum conditions, a good linearity was achieved in the concentration range of 0.1–50.0 ng mL?1 for bottled water sample and 0.2–50.0 ng mL?1 for peach juice and soft drink samples. The limits of detection of the method (S/N = 3) were 0.02 ng mL?1 for bottled water sample, and 0.04–0.05 ng mL?1 for peach juice and soft drink samples. The results indicated that the MOF‐5‐C exhibited an excellent adsorption capability for trace levels of phthalate esters, and it could be a promising adsorbent for the preconcentration of other organic compounds.  相似文献   

19.
A sensitive and accurate method is described for the determination of ultra-trace nickel in environmental samples with in-situ trapping of volatile species in iridium-palladium coated graphite furnace atomic absorption spectrometry. The effects of the conditions for the generation and collection of volatile nickel species, such as medium acidity, potassium borohydride concentration, enhancement reagent concentration, reaction temperature, as well as graphite tube coating, carrier gas flow rate and trapping time were investigated. Phenanthroline was selected as the enhancement reagent due to its good enhancing effect, and iridium–palladium coating was used for the in-situ trapping of volatile nickel species at 300°C. Under the optimal conditions, the calibration curve was linear from 0.21 up to 30.0 ng mL?1 with correlation coefficient of 0.9991, the detection limit (S/N = 3) was 0.21 ng mL?1 for 4 mL sample volumes and the relative standard deviation for 11 determinations of Ni at 10 ng mL?1 was 3.5%. The results found by the proposed methods are accordant with the certified values of water, soil and tea certified reference materials. The proposed methods have been applied for the determination of ultra-trace Ni in tap, river and wastewater, as well as rice and soil samples, with recoveries ranging from 97.3 to 100.5%.  相似文献   

20.
In present study, a simultaneous derivatization and air‐assisted liquid–liquid microextraction method combined with gas chromatography–nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1‐flouro‐2,4‐dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05–0.34 ng mL?1 are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号