首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Various sensor‐based immunoassay methods have been extensively developed for the detection of cancer antigen 15‐3 (CA 15‐3), but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. The aim of this work is to develop a simple and sensitive electrochemical immunoassay for CA 15‐3 in human serum by using nanogold and DNA‐modified immunosensors. Prussian blue (PB), as a good mediator, was initially electrodeposited on a gold electrode surface, then double‐layer nanogold particles and double‐strand DNA (dsDNA) with the sandwich‐type architecture were constructed on the PB‐modified surface in turn, and then anti‐CA 15‐3 antibodies were adsorbed onto the surface of nanogold particles. The double‐layer nanogold particles provided a good microenvironment for the immobilization of biomolecules. The presence of dsDNA enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The performance and factors influencing the performance of the immunosensor were evaluated. Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 1.0 to 240 ng/mL with a relatively low detection limit of 0.6 ng/mL (S/N=3) towards CA 15‐3. The stability, reproducibility and precision of the as‐prepared immunosensor were acceptable. 57 serum specimens were assayed by the developed immunosensor and standard enzyme‐linked immunosorbent assay (ELISA), respectively, and the results obtained were almost consistent. More importantly, the proposed methodology could be further developed for the immobilization of other proteins and biocompounds.  相似文献   

2.
This article presents a simple chronoamperometric immunosensor for the quantitative assessment of creatine kinase MB (CK-MB) in 50 μL undiluted serum samples. The immunosensor consists of gold working and counter electrodes patterned onto a glass chip by thin-film photolithography and an external Ag|AgCl reference electrode. The detection limit (DL) of the chronoamperometric method is 13 ng mL−1 (DL = 2×RMSD/S, where RMSD is the residual mean standard deviation of the measured points around a calibration curve with a slope of S). In spiked serum samples, the response was linear up to 300 ng mL−1 of CK-MB. A surface plasmon resonance (SPR) system with simultaneous electrochemical detection (EC-SPR) aided the development of the sandwich immunoassay. Real-time monitoring of the SPR signal was used to optimize the capture antibody immobilization, CK-MB and detection antibody binding, as well as to minimize the nonspecific adsorption of serum proteins to the sensor surface. The detection antibody has been labeled with alkaline phosphatase (ALP) enzyme for sensitive electrochemical detection. ALP catalyzes the hydrolysis of ascorbic acid phosphate and generates ascorbic acid, which is measured chronoamperometrically. The electrochemical immunoassay for CK-MB was less sensitive to nonspecific adsorption related interferences, had a better detection limit, and required a lower volume of sample than the SPR method.  相似文献   

3.
The layer‐by‐layer (LbL) self‐assembly has been used to fabricate polymer thin films on any solid substrates. The multilayer polymer thin films are constructed by alternating adsorption of anionic and cationic polymers. Polyelectrolyte multilayer ultrathin films containing anionic poly[2‐(thiophen‐3‐yl)ethyl methacrylate‐co‐methacrylic acid]; P(TEM‐co‐MA) and cationic poly[4‐(9H‐carbazol‐9‐yl)‐N‐butyl‐4‐vinyl pyridium bromide]; P4VPCBZ, were fabricated. The growth of multilayer ultrathin films was followed by UV–Vis absorption spectrophotometer and surface plasmon resonance spectroscopy (SPR). The deposition of P(TEM‐co‐MA)/P4VPCBZ as multilayer self‐assembled ultrathin films regularly grow which showed linear growth of absorbance and thickness with increasing the number of layer pair. Cross‐linking of the layers was verified by cyclic voltammetry (CV), UV–Vis spectrophotometry and electrochemical surface plasmon resonance (EC‐SPR) spectroscopy with good electro‐copolymerizability. This was verified by spectroelectrochemistry. The SPR angular‐reflectivity measurement resulted in shifts to a higher reflectivity according to the change in the dielectric constant of the electropolymerized film. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of this work is the preparation of DNA‐sensing architectures based on gold nanoparticles (AuNPs) in conjunction with an enzyme‐amplified detection to improve the analytical properties of genosensor. In order to assess the utility of study as DNA‐sensing devices, a thiolated DNA capture probe sequence was immobilized on the gold nanoparticle modified surface. After labeling of the biotinylated hybrid with a streptavidin‐alkaline phosphatase conjugate, the electrochemical detection of the enzymatic product was performed on the surface of a disposable electrode. Two different enzymatic substrates to detect the hybridization event were studied. In the first case, the enzyme catalyzed the hydrolysis of α‐naphthyl phosphate; the product is electroactive and has been detected by means of differential pulse voltammetry (DPV). In the second one, the enzyme catalyzed the precipitation of an insoluble and insulating product on the sensing interface. In this case, the electrochemical transduction of the hybridization process was performed by electrochemical impedance spectroscopy (EIS).  相似文献   

5.
A simple and portable electrochemical immunosensor for the detection of total prostate specific antigen (t‐PSA) in human serum was developed using a double‐layer nanogold particles and dendrimer‐functionalized polyvinyl chloride (PVC) membrane as immunosensing interface. To fabricate such a multifunctional PVC electrode, an o‐phenylenediaminedoped PVC membrane was initially constructed, then nanogold particles and poly(amidoamine) G4‐dendrimer with a sandwich‐type format were assembled onto the PVC membrane surface, and then t‐PSA antibodies (anti‐PSA) were adsorbed on the nanogold surface. The detection principle of the immunosensor is based on the change in the electric potential before and after the antigen‐antibody interaction. The experimental conditions and the factors influencing the performance of the immunosensor were investigated. Under optimal conditions, the proposed immunosensor exhibits good electrochemical behavior in the dynamic range of 0.5–18 ng/mL relative to t‐PSA concentration with a relative low detection limit of 0.1 ng/mL (S/N=3). The precision, reproducibility, and stability of the immunosensor are acceptable. In addition, 43 serum specimens were assayed by the as‐prepared immunosensor, and consistent results were obtained in comparison with those obtained by the standard enzyme‐linked immunosorbent assay (ELISA). Compared with the conventional ELISAs, the developed immunoassay system was simple and rapid without labeling and separation steps. Importantly, the immobilization and detection methodologies could be extended for the immobilization and detection of other biomarkers.  相似文献   

6.
《Analytical letters》2012,45(12):2237-2250
Abstract

An ultrasensitive electrochemical immunoassay based on biocatalytic deposition has been proposed for the detection of Schistosoma japonicum antibody (SjAb) in infected rabbit serum. Schistosoma japonicum antigen (SjAg) was immobilized on the gold electrode surface via glutaraldehyde crosslink and then incubated with infected rabbit serum containing SjAb; finally, the goat anti-rabbit IgG labeled with alkaline phosphatase was sandwiched to form the immunocomplex on the gold electrode surface. The alkaline phosphatase converted nonelectroactive substrate into the reducing agent and the latter, in turn, reduced metal ions to form electroactive metallic product on the electrode surface. Linear sweep voltammetry (LSV) was used to quantify the amount of the deposited silver and give the analytical signal for SjAb. Assay conditions such as the antigen concentration and enzymatic silver deposition time were optimized. The electrochemical immunosensor was able to realize a reliable determination of SjAb in the dilution range from 1:5000 to 1:100 with a detection limit of 1:6457 of dilution ratio. The feasibility of the proposed immunosensor for possible clinical applications was also investigated by analyzing real serum samples.  相似文献   

7.
研制了一种基于纳米金固定半抗原的间接竞争电化学免疫传感器,可灵敏检测克伦特罗.在金电极表面组装1,6-己二硫醇单分子膜,通过Au-S共价作用连接纳米金颗粒,通过吸附作用固定克伦特罗牛血清白蛋白偶联物.样品中的待测组分与固定化的克伦特罗偶联物竞争结合单克隆抗体,碱性磷酸酯酶标记的二抗选择性地与电极表面捕获的一抗反应,进而催化底物1-萘酚磷酸酯水解生成1-萘酚,在电极表面氧化产生电信号.在优化的实验条件下,克伦特罗浓度在0.1~1000 μg/L范围内与电流强度线性相关,线性方程为I(A)-8.79× 10-7-2.66× 10-7logC (μg/L),相关系数0.9960,检出限达20 ng/L.同时测定了猪肉及猪肝样品中克伦特罗含量,相对标准偏差平均值为7.0%,加标回收率在89.1%~105.6%之间,与传统的间接竞争酶联免疫吸附法对照,结果无显著性差异.  相似文献   

8.
In this work, an electrochemical DNA biosensor, based on a dual signal amplified strategy by employing a polyaniline film and gold nanoparticles as a sensor platform and enzyme‐linked as a label, for sensitive detection is presented. Firstly, polyaniline film and gold nanoparticles were progressively grown on graphite screen‐printed electrode surface via electropolymerization and electrochemical deposition, respectively. The sensor was characterized by scanning electron microscopy (SEM), cyclic voltammetry and impedance measurements. The polyaniline‐gold nanocomposite modified electrodes were firstly modified with a mixed monolayer of a 17‐mer thiol‐tethered DNA probe and a spacer thiol, 6‐mercapto‐1‐hexanol (MCH). An enzyme‐amplified detection scheme, based on the coupling of a streptavidin‐alkaline phosphatase conjugate and biotinylated target sequences was then applied. The enzyme catalyzed the hydrolysis of the electroinactive α‐naphthyl phosphate to α‐naphthol; this product is electroactive and has been detected by means of differential pulse voltammetry. In this way, the sensor coupled the unique electrical properties of polyaniline and gold nanoparticles (high surface area, fast heterogeneous electron transfer, chemical stability, and ease of miniaturisation) and enzymatic amplification. A linear response was obtained over a concentration range (0.2–10 nM). A detection limit of 0.1 nM was achieved.  相似文献   

9.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

10.
Sandwich immunoassay was conducted on a thin gold film set in a surface plasmon resonance (SPR) cell. Monochronal antibody (anti-IgG) was immobilized onto the gold film via 4,4′-dithiodibutyric acid (DDA) and avidin-biotin bonding. Next, IgG sample and alkaline phosphatase-conjugated anti-IgG (ALP anti-IgG) were introduced into the cell successively. Finally, p-aminophenyl phosphate (PAPP) was injected as an enzyme substrate, and the produced p-aminophenol (PAP) was electrochemically measured. Flow did not need to be stopped for incubation for the enzyme reaction, because of the thinness of the cell. In these processes, all the antigen-antibody reactions took place on the gold film. Therefore, the immobilization was performed quickly, and each process could be confirmed by SPR signal. This system had the advantage that the middle of the complicated process could be monitored. For example, the amount of antibody immobilized, which affected on the final electrochemical signal, could be confirmed in the course of immobilization. It was also convenient to investigate process conditions, such as removal of used antigens and labeled antibodies. Good correlation was obtained between the electrochemical current and the SPR signals due to the adsorption of IgG and ALP anti-IgG, and the sensitivity of the electrochemical measurement was much higher than the SPR’s.  相似文献   

11.
In this paper, we have critically evaluated the electrochemical behavior of the products of seven substrates of the enzyme label, alkaline phosphate, commonly used in electrochemical immunosensors. These products (and the corresponding substrates) include indigo carmine (3-indoyl phosphate), hydroquinone (hydroquinone diphosphate), 4-nitrophenol (4-nitrophenol phosphate), 4-aminophenol (p-aminophenyl phosphate), 1-naphthol (1-naphthyl phosphate), phenol (phenyl phosphate), and L-ascorbic acid (2-phospho-L-ascorbic acid). Cyclic voltammetry and amperometry of these products were carried out at glassy carbon (GC), screen-printed carbon (SPC) and gold (Au) electrodes, respectively. Among the products, L-ascorbic acid showed the most sensitive (24.8 microA cm(-2), 12.0 microA cm(-2), and 48.0 microA cm(-2) of 100 microM ascorbic acid at GC, SPC, and Au electrodes, respectively) and well-defined amperometric response at all electrodes used, making 2-phospho-l-ascorbic acid the best substrate in electrochemical detection involving an alkaline phosphatase (ALP) enzyme label. The 2-phospho-L-ascorbic acid is also commercially available and inexpensive. Therefore, it was the best choice for electrochemical detection using ALP as label. Using mouse IgG as a model, an ALP enzyme-amplified sandwich-type amperometric immunosensor was constructed. The immunosensor was designed by electropolymerization of o-aminobenzoic acid (o-ABA) conductive polymer on the surface of GC, SPC, and Au electrodes. The anti-mouse IgG was subsequently attached on the electrode surface through covalent bonding between IgG antibody and the carboxyl groups from poly(o-ABA). Using 2-phospho-L-ascorbic acid as a substrate, the poly(o-ABA)/Au immunosensor produced the best signal (about 297 times of current density response ratio between 1000 ng mL(-1) and 0 ng mL(-1) of mouse IgG), demonstrating that amperometric immunosensors based on a conducting polymer electrode system were sensitive to concentrations of the mouse IgG down to 1 ng mL(-1), with a linear range of 3-200 ng mL(-1) (S.D.<2; n=3), and very low non-specific adsorption.  相似文献   

12.
《Electroanalysis》2004,16(23):1931-1937
Calf thymus DNA was immobilized on functionalized glassy carbon, gold and quartz substrates, respectively, by the layer‐by‐layer (LBL) assembly method with a polycation QPVP‐Os, a quaternized poly(4‐vinylpyridine) partially complexed with osmium bis(2,2′‐bipyridine) as counterions. UV‐visible absorption and surface plasmon resonance spectroscopy (SPR) showed that the resulting film was uniform with the average thickness 3.4 nm for one bilayer. Cyclic voltammetry (CV) showed that the total surface coverage of the polycations increases as each QPVP‐Os/DNA bilayer added to the electrode surface, but the surface formal potential of Os‐centered redox reaction shifts negatively, which is mainly attributed to the intercalation of redox‐active complex to DNA chain. The electron transfer kinetics of electroactive QPVP‐Os in the multilayer film was investigated by electrochemical impedance experiment for the first time. The permeability of Fe(CN) in the solution into the multilayer film depends on the number of bilayers in the film. It is worth noting that when the multilayer film is up to 4 bilayers, the CV curves of the multilayer films display the typical characteristic of a microelectrode array. The nanoporous structure of the multilayer film was further confirmed by the surface morphology analysis using atomic force microscopy (AFM).  相似文献   

13.
《Electroanalysis》2018,30(1):31-37
The electrochemical detection of alpha‐feto protein based on novel gold nanoparticles‐ poly(propylene imine) dendrimer platform is reported. The platform was prepared by co‐electrodeposition of gold nanoparticles and generation 3 poly (propylene imine) dendrimer on a glassy carbon electrode. Each modifying step was characterised by cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical measurements showed that the platform was stable, conducting and exhibited reversible electrochemistry. Results obtained from the electrochemical impedance spectroscopy interrogation in [Fe(CN)63−/4−] redox probe showed a marked reduction in charge transfer resistance (Rct) after each modification step. The immunosensor was prepared by immobilisation of a probe anti‐alpha feto protein (AFP) on the platform for 3 hrs at 35 °C followed by blocking the surface with bovine serum albumin to minimise non‐specific binding. The prepared immunosensor was used to detect AFP over a wide concentration range from 0.005 to 500 ng/mL and detection limits of 0.0022 and 0.00185 ng/mL were obtained for SWV and EIS measurements respectively. The immunosensor gave good stability over a period of fourteen days when stored at 4 °C.  相似文献   

14.
A novel dual electrochemical immunosensor for the multiplexed determination of adrenocorticotropin (ACTH) and cortisol is reported. Aminophenylboronic acid‐modified dual screen‐printed carbon electrodes were prepared on which the corresponding ACTH and cortisol antibodies were immobilized. Competitive immunoassays involved biotinylated ACTH and alkaline phosphatase labelled streptavidin, or alkaline phosphatase labelled cortisol. Differential pulse voltammetry upon 1‐naphtyl phosphate addition was employed to monitor the affinity reactions. The ranges of linearity were 5.0×10?5?0.1 and 0.1?500 ng/mL for ACTH and cortisol. The usefulness of the dual immunosensor was demonstrated by analyzing certified human serum samples with good recoveries.  相似文献   

15.
In this paper we describe the deposition of enzyme layers on cyclodextrin-modified surfaces through self-assembly with adamantane-appended alkaline phosphatase using cyclodextrin-capped gold nanoparticles as supramolecular linkers. The system was studied by surface plasmon resonance and electrochemical methods (cyclic voltammetry, impedance spectroscopy). Up to three enzyme layers were formed on the cyclodextrin coated electrodes and the modified surface was used for the electrochemical detection of heavy metals (Cd2+, Ag+) based on the inhibition of enzymatic activity by these metal cations.  相似文献   

16.
A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL(-1) with a slope value of 7.0 nA mL ng(-1). The limit of detection was 3.74 ng mL(-1). Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.  相似文献   

17.
Qu B  Chu X  Shen G  Yu R 《Talanta》2008,76(4):785-790
A novel electrochemical immunosensor using functionalized silica nanoparticles (Si NPs) as protein tracer has been developed for the detection of prostate specific antigen (PSA) in human serum. The immunosensor was carried out based on a heterogeneous sandwich procedure. The PSA capture antibody was immobilized on the gold electrode via glutaraldehyde crosslink. After reaction with the antigen in human serum, Si NPs colabeled with detection antibody and alkaline phosphatase (ALP) was sandwiched to form the immunocomplex on the gold electrode. ALP carried by Si NPs convert nonelectroactive substrate into the reducing agent and the latter, in turn, reduce metal ions to form electroactive metallic product on the electrode. Linear sweep voltammetry (LSV) was used to quantify the amount of the deposited silver and give the analytical signal for PSA. The parameters including the concentration of the ALP used to functionalize the Si NPs and the enzyme catalytic reaction time have been studied in detail and optimized. Under the optimum conditions of immunoreaction and electrochemical detection, the electrochemical immunosensor was able to realize a reliable determination of PSA in the range of 1–35 ng/mL with a detection limit of 0.76 ng/mL. For six human serum samples, the results performed with the electrochemical immunosensor were in good agreement with those obtained by chemiluminescent microparticle immunoassay (CMIA), indicating that the electrochemical immunosensor could satisfy the need of practical sample detection.  相似文献   

18.
A sensitive and specific electrochemical immunosensor was developed with α‐fetoprotein (AFP) as the model analyte by using gold nanoparticle label for enzymatic catalytic amplification. A self‐assembled monolayer membrane of mercaptopropionic acid (MPA) was firstly formed on the electrode surface through gold‐sulfur interaction. Monoclonal mouse anti‐human AFP was covalently immobilized to serve as the capture antibody. In the presence of the target human AFP, gold nanoparticles coated with polyclonal rabbit anti‐human AFP were bound to the electrode via the formation of a sandwiched complex. With the introduction of goat anti‐rabbit IgG conjugated with alkaline phosphatase, the dentritical enzyme complex was formed through selective interaction of the secondary antibodies with the colloidal gold‐based primary antibody at the electrode, thus affording the possibility of signal amplification for AFP detection. Current response arising from the oxidation of enzymatic product was significantly amplified by the dentritical enzyme complex. The current signal was proportional to the concentration of AFP from 1.0 ng mL?1 to 500 ng mL?1 with a detection limit of 0.8 ng mL?1. This system could be extended to detect other target molecules with the corresponding antibody pairs.  相似文献   

19.
In this work, we present a new electrochemical disposable platform based on poly(aniline‐co‐anthranilic acid) (PANI/PAA) composite polymer coupled with an aptamer for sensitive detection of β‐lactoglobulin. Firstly, PANI/PAA film was electrodeposited on the graphite screen‐printed electrode surface by cyclic voltammetry. The co‐polymer modified electrode was then employed as platform for the covalent immobilization of an amino‐modified aptamer. Various β‐lactoglobulin solutions, with a fixed amount of biotinylated oligonucleotide complementary sequence, were dropped onto the aptasensor surface. A streptavidin‐alkaline phosphatase conjugate was then employed to trace the affinity reaction. After the addition of 1‐naphthyl‐phosphate enzymatic substrate, 1‐naphthol electroactive product was detected by differential pulse voltammetry. A decrease in the signal was obtained when the target concentration was increased, in according to a signal‐off approach. After optimization of key experimental parameters, a dose‐response curve was obtained between 0.01–1.0 μg mL?1 β‐lactoglobulin concentration range. The limit of detection of 0.053 μg L?1 was obtained. Milk samples spiked with β‐lactoglobulin were analyzed.  相似文献   

20.
《Analytical letters》2012,45(14):2641-2652
Abstract

A surface plasmon resonance (SPR)‐immunosensor based on nano‐size gold hollow ball (GHB) with dendritic surface has been developed for detection of Ochratoxin A (OTA). A thionine thin film was initially electropolymerized onto the SPR‐probe surface, and then anti‐OTA monoclonal antibody (anti‐OTA) was immobilized onto the SPR‐probe surface by means of GHB conjugation. The binding of target molecules onto the immobilized antibodies causes an increase in the resonant angle of the sensor chip, and the resonant angle shift was proportional to the OTA concentration in the range of 0.05–7.5 ng/ml with a detection limit of 0.01 ng/ml at a signal/noise ration of 3. A glycine‐HCl solution (pH 2.8) was used to release antigen‐antibody complexes from the biorecognition surface. Good reusability was exhibited. Moreover, spiking various levels of OTA into three milk samples was assayed using the proposed immunoassay. Analytical results show the precision of the developed immunoassay is acceptable. Compared with the conventional enzyme‐linked immunosorbent assay, the proposed immunoassay system was simple and rapid without multiple labeling and separation steps. Importantly, the proposed immunoassay system could be further developed for the immobilization of other antigens or biocompounds.  相似文献   