首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2005,17(1):47-53
γ‐Aminopropyltriethoxysilane (APTES)‐induced solubilization of multi‐wall carbon nanotube CNTs allowed for the modification of electrode surfaces. APTES also served as an immobilization matrix for putrescine oxidase (POx) to construct an amperometric biosensor. Although CNTs modified by APTES acted as semiconductors to reduce the exposed sensing surface, we reasoned that nanoscale “dendrites” of CNTS modified by APTES formed a network and projected outwards from the electrode surface and acted like bundled ultra‐microelectrodes that allowed access to the active site and facilitated direct electron transfer to the immobilized enzyme. Our biosensor was able to efficiently monitor direct electroactivity of POx at the electrode surface. The putrescine biosensor prepared using the modified glassy carbon electrode exhibited current response within 10 s with a detection limit of 500 nM.  相似文献   

2.
In this article, we detail a paper‐based three‐electrode electrochemical biosensor using a mitochondria modified Toray carbon paper working electrode. Cyclic voltammetry performed on the paper‐based biosensor and similar electrodes in a common laboratory setup (not in an integrated paper‐based device) compare favorably. In addition, instant detection of malathion with a detection limit of 20 nM by cyclic voltammetry is demonstrated, showing the device can potentially be used as a portable platform for pesticides detection.  相似文献   

3.
In this paper a graphene (GR) modified carbon ionic liquid electrode (CILE) was fabricated and used as the voltammetric sensor for the sensitive detection of catechol. Due to the specific physicochemical characteristics of GR such as high surface area, excellent conductivity and good electrochemical properties, the modified electrode exhibits rapid response and strong catalytic activity with high stability toward the electrochemical oxidation of catechol. A pair of well‐defined redox peaks appeared with the anodic and the cathodic peak potential located at 225 mV and 133 mV (vs.SCE) in pH 6.5 phosphate buffer solution, respectively. Electrochemical behaviors of catechol on the GR modified CILE were carefully investigated and the electrochemical parameters were calculated with the results of the electrode reaction standard rate constant (ks) as 1.24 s?1, the charge transfer coefficient (α) as 0.4 and the electron transfer number (n) as 2. Under the selected conditions the differential pulse voltammetric peak current increased linearly with the catechol concentrations in the range from 1.0 × 10‐7 to 7.0 × 10?4mol L‐1 with the detection limit as 3.0 × 10?8mol L‐1 (3σ). The proposed method was further applied to the synthetic waste water samples determination with satisfactory results  相似文献   

4.
《Electroanalysis》2004,16(8):684-687
In 0.05 mol/L phosphate buffer solution (pH 7.0), carbon nanotubes modified electrode exhibits rapid response, strong catalytic activity with high stability toward the electrochemical oxidation of catechol. The electrochemical behavior of catechol on both the multi‐walled and single‐walled carbon nanotubes modified electrode was investigated. The experimental conditions, such as pH of the solution and scan rate were optimized. The currents (measured by constant potential amperometry) increase linearly with the concentrations of catechol in the range of 2.0×10?5–1.2×10?3 mol/L. Moreover, at the multi‐walled carbon nanotubes modified electrode the electrochemical responses of catechol and ascorbic acid can be separated clearly.  相似文献   

5.
Fungal laccase (Lc) from the basidiomycete Trametes hirsuta was immobilized on top of a carbon ceramic electrode using physical absorption. Direct, unmediated heterogeneous electron transfer between Lc and the carbon ceramic electrode (CCE) under aerobic conditions was shown. The bioelectrocatalytic reduction of oxygen on Lc‐CCE started at about 430 mV vs. Ag|AgCl|KClsat at pH 3.5 and moved with about 57 mV in the cathodic region per pH unit. The Lc‐modified CCE was then used as a biosensing detection element in a single line flow injection system for the amperometric determination of a variety of phenolic substrates of the enzyme. The experimental conditions were studied and optimized for catechol serving as a model compound. Statistical aspects were applied and the sensor characteristics and Michaelis‐Menten constants of the investigated phenolic compounds were calculated and compared with those obtained for solid graphite electrodes modified with Trametes hirsuta laccase. The results showed that the CCE based biosensor in comparison with the solid graphite based biosensor offers a lower detection limit, a wider linear dynamic range, and excellent operational stability with no sensor passivation, indicating that the sol–gel lattice improves the electrochemical behavior of the biosensor.  相似文献   

6.
《Electroanalysis》2005,17(10):857-861
The carbon nanotubes decorated nanoplatinum (CNT‐Pt) were prepared using a chemical reduction method and a novel base electrode was constructed by intercalating CNT‐Pt on the surface of a waxed graphite electrode. The results showed that the nano‐particles of platinum at a waxed graphite electrode exhibits high catalytic activity for the reduction of hydrogen peroxide. The cholesterol oxidase (ChOx), chosen as a model enzyme, was immobilized with sol‐gel on the CNT‐Pt base electrode to construct a biosensor. The current response of the biosensor for cholesterol was very rapid (<20 s). The linear range for cholesterol measurement was 4.0×10?6 mol/L ?1.0×10?4 mol/L with a detection limit of 1.4×10?6 mol/L. The experiments also showed that the ChOx/sol‐gel/CNT‐Pt biosensor was sensitive and stable in detecting cholesterol in serum samples.  相似文献   

7.
Titanium‐containing MCM‐41 (Ti‐MCM‐41) modified glassy carbon electrode (GCE) can exhibit an excellent electrocatalytic activity towards the oxidation of β‐Nicotinamide adenine dinucleotide (NADH). A dramatic decrease in the over‐voltage of NADH oxidation reaction is observed at 0.28 V (vs. SCE). The modified electrode is found to be stable and reproducible. The electrode shows a linear response for a wide range of 10–1200 μM NADH and the detection limit is 8.0 μM. Ti‐MCM‐41 mesoporous molecular sieves provide an efficient matrix for development of NADH biosensors and the prepared electrode not only can be used to detect the concentration of NADH in biochemical reaction, but also as the potential matrix of the construction of dehydrogenases biosensor.  相似文献   

8.
《Electroanalysis》2003,15(20):1577-1583
Laccase enzymes from two different sources, namely, tree laccase from Rhus vernicifera and fungal laccase from Coriolus hirsutus were used for the development of biosensor for catechol. Laccase was immobilized onto the amine terminated thiol monolayers on gold surface by glutaraldehyde coupling. From the different thiol monolayers investigated, cystamine was found to be optimal with respect to sensitivity, stability, reproducibility, and other electrochemical properties of the enzyme electrode. Linear calibration in the range between 1 and 400 μM for catechol was obtained for fungal laccase covalently coupled on the electrode surface. The kinetic parameters determined using the Lineweaver‐Burk and Eadie‐Hofstee plots were Km=0.65 mM and Vmax=24.5 μA for fungal laccase compared to Km=5.4 mM and Vmax=6.6 μA for tree laccase on cystamine monolayer. The electrode showed good stability for 1 month without loosing appreciable activity when stored dry in a refrigerator at ?20 °C.  相似文献   

9.
《Analytical letters》2012,45(9):1785-1799
Abstract

Multiwalled carbon nanotubes (MWNTs) were treated with a mixture of concentrated sulfuric and nitric acid to introduce carboxylic acid groups to the nanotubes. Conducting polymer film was prepared by electrochemical polymerization of neutral red (NR). By using a layer‐by‐layer method, homogeneous and stable MWNTs and poly (neutral red) (PNR) multilayer films were alternately assembled on glassy carbon (GC) electrodes. With the introduction of PNR, the MWNTs/PNR multilayer film system showed synergy between the MWNTs and PNR, with a significant improvement of redox activity due to the excellent electron‐transfer ability of carbon nanotubes (CNTs) and PNR. The electropolymerization is advantageous, providing both prolonged long‐term stability and improved catalytic activity of the resulting modified electrodes. The MWNTs/PNR multilayer film modified glassy carbon electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As compared to MWNTs and PNR‐modified GC electrodes, the magnitude of the amperometric response of the MWNTs/PNR composite‐modified GC electrode is more than three‐fold greater than that of the MWNTs modified GC electrode, and nine‐fold greater than that of the PNR‐modified GC electrode. With the immobilization of glucose oxidase onto the electrode surface using glutaric dialdehyde, a biosensor that responds sensitively to glucose has been constructed. In pH 6.98 phosphate buffer, nearly interference‐free determination of glucose has been realized at ?0.2 V vs. SCE with a linear range from 50 µM to 10 mM and response time <10s. The detection limit was 10 µM glucose (S/N=3).  相似文献   

10.
《Electroanalysis》2004,16(20):1697-1703
An amperometric glucose biosensor based on multi‐walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT‐modified glassy carbon electrode was obtained by casting the electrode surface with multi‐walled carbon nanotube materials. Glucose oxidase was co‐immobilized on the MWCNT‐modified glassy carbon surface by electrochemical deposition of poly(o‐phenylenediamine) film. Enhanced catalytic electroreduction behavior of oxygen at MWCNT‐modified electrode surface was observed at a potential of ?0.40 V (vs. Ag|AgCl) in neutral medium. The steady‐state amperometric response to glucose was determined at a selected potential of ?0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4‐acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.  相似文献   

11.
Leech D  Daigle F 《The Analyst》1998,123(10):1971-1974
Here we report on the optimisation of a reagentless enzyme sensor for the detection of azide based on the mediated reduction of O2 by a laccase enzyme co-immobilised in a redox hydrogel on electrode surfaces. The sensor response is shown to be influenced by the enzyme loading, the electrolyte pH and ionic strength. The response of the sensor is stable, decreasing by only 25% over a sixteen-hour period. Reproducible inhibition curves for the determination of azide levels from cyclic voltammetric scans can be obtained by normalisation of the sensor response. The resulting enzyme inhibition biosensor can detect levels of azide as low as 2.5 microM under these conditions. Constant potential amperometric detection at the laccase enzyme electrode in a flow injection set-up yields a peak current for inhibition of the mediated reduction of O2. Reproducible peak currents and areas (8.0 and 6.3% RSD, respectively, for n = 11) are obtained for repeated injections of 100 microM azide. Reproducible response curves can be obtained by injection of a 25 mM azide sample and assuming that the peak height and peak area obtained represent 100% inhibition of the enzyme.  相似文献   

12.
A novel MB‐SWNT‐sol‐gel nanocomposite material was prepared by the sol‐gel process incorporating a redox mediator and carbon nanotubes. The electrocatalytic properties of the nanomaterial based sensor toward NADH oxidation were studied by electrochemical measurements. Significant enhancement of oxidation current is obtained at electrodes modified by MB‐SWNT‐sol‐gel in comparison with the analogous carbon black and/or graphite composite modified electrode. The usefulness of the nanocomposite material as a matrix for immobilizing enzymes is also demonstrated. Analytical parameters of D ‐lactate biosensors with and without SWNT in the hybrid film were compared demonstrating that performance of the biosensor was significantly improved when introducing SWNT.  相似文献   

13.
Polyphenol oxidases from eggplant have a high catalytic activity for the aerobic oxidation of catechol to o-quinone with selectivity over other phenolic substrates. An amperometric biosensor can therefore be constructed by incorporating selected portions of eggplant tissue in a carbon paste electrode. The proposed biosensor provides a selective response for catechol in the micromolar range, with a very fast response time and a useful lifetime of at least 3 weeks.  相似文献   

14.
D. Cakmak  T. Bulut  D. Uzun 《Electroanalysis》2020,32(7):1559-1570
This present study describes a pencil graphite electrode surface covered with Cu(II) and Fe(III) complexes based on Salophen derivative Schiff bases in acetonitrile solution containing LiClO4 as a supporting electrolyte. Cyclic voltammetry method was used for the surface modification procedure with 25 cycle at a sweep rate of 50 mV s?1. Some characterization methods were used to identify of the prepared modified surfaces including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Ultraviolet‐visible Spectroscopy (UV‐Vis), and Scanning Electron Microscopy/Energy Dispersive X‐ray Spectroscopy (SEM/SEM‐EDX). The catalytic activity of these modified surfaces on the electrochemical oxidation of catechol (CC) was investigated and they compared with each other. The results demonstrated that these modified electrodes showed perfect electrocatalytic activity on the catechol determination, however the modified electrode prepared with the Cu(II) complex has higher catalytic activity than this prepared with the Fe(III) complex thanks to its the lower detection limit.  相似文献   

15.
Au/TiO2 nanorod composites with different ratios of [TiO2]:[Au] have been prepared by chemically reducing AuCl4 on the positively charged TiO2 nanorods surface and used to modify boron‐doped diamond (BDD) electrodes. The electrochemical behaviors of catechol on the bare and different Au/TiO2 nanorod composites‐modified BDD electrodes are studied. The cyclic voltammetric results indicate that these different Au/TiO2 nanorod composites‐modified BDD electrodes can enhance the electrocatalytic activity toward catechol detection, as compared with the bare BDD electrode. Among these different conditions, the Au/TiO2‐BDD3 electrode (the ratio of [TiO2]:[Au] is 27:1) is the most choice for catechol detection. The electrochemical response dependences of the Au/TiO2‐BDD3 electrode on pH of solution and the applied potential are studied. The detection limit of catechol is found to be about 1.4 × 10‐6 M in a linear range from 5 × 10‐6 M to 200 × 10‐6 M on the Au/TiO2‐BDD3 electrode.  相似文献   

16.
纳米铂修饰玻碳电极对邻苯二酚的电化学氧化及测定   总被引:2,自引:0,他引:2  
应用循环伏安法研究了邻苯二酚在纳米铂修饰玻碳(PtNPs/GC)电极上的电化学氧化行为。实验表明,PtNPs/GC电极对邻苯二酚有很强的电催化作用,其伏安扫描氧化峰电流随着温度的升高而增大,但氧化峰电位略有负移。常温下,邻苯二酚能自发在电极表面发生聚合反应,生成具有导电性的聚合膜,其催化氧化电流与邻苯二酚浓度在1.0×10-6mol/L~5.0×10-5mol/L范围内呈良好的线性关系,检出限为2.9×10-7mol/L。  相似文献   

17.
In this study, a sandwich‐type electrochemical enzyme‐based LNA‐modified DNA biosensor was developed to detect relative gene in chronic Myelogenous Leukemia first. This biosensor is based on a ‘sandwich’ detection strategy, which involves a pair of probes (a capture probe immobilized at the electrode surface and a reporter probe labeled biotin as an affinity tag for avidin‐HRP) modified LNA. Since biotin can be connected with avidin‐HRP, this biosensor offers an enzymatically amplified electrochemical current signal for the detection of target DNA. This new pattern exhibits high sensitivity and selectivity, and this biosensor has been used for an assay of PCR real sample with satisfactory result.  相似文献   

18.
This work describes the development of a biosensor for paracetamol (PAR) determination based on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) and laccase enzyme (LAC), which was immobilized by means of covalent crosslinking using glutaraldehyde. Voltammetric investigations were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The biosensor was characterized by Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FT‐IR). The results showed that the use of MWCNT/LAC composite increased the sensor sensitivity, compared to bare glassy carbon electrode. Factors affecting the voltammetric signals such as pH, ionic strength, scan rate and interferents were assessed. Linear range, limit of detection (LOD) and limit of quantitation (LOQ) obtained were 10–320 μmol L?1, 7 μmol L?1 and 10 μmol L? 1, respectively. The developed biosensor was successfully applied to PAR determination in urine and pharmaceutical formulations samples, with recovery varying from 99.96 to 106.20 % in urine samples and a relative standard deviation less than 1.04 % for PAR determination in pharmaceutical formulations. Therefore, the MWCNT‐LAC/GCE exhibits excellent sensitivity and can be used to PAR determination as a viable alternative in clinical analyzes and quality control of pharmaceutical formulations, through a simple, fast and inexpensive methodology.  相似文献   

19.
In this study, stable CotA laccase from Bacillus subtilis 168 was adsorbed on electrode modified with a thiol graphene‐gold nanoparticle (thGP‐AuNPs) nanocomposite film. The novel bacterial laccase biosensor was employed for quantitative detection of hydroquinone (HQ) and the electrochemical properties of this laccase biosensor were investigated. The results indicate that the immobilized CotA shows great oxidation activity towards HQ in the presence of oxygen and the biosensor shows linear electrocatalytic activity in the concentration range from 1.6 to 409.6 μM, with a detection limit of 0.3 μM. Further, the CotA modified electrode, when compared to fungal laccase‐modified biosensors, shows better alkaline stability (retaining approximately 80 % and 70 % of response current at pH 8 and 9, respectively) and reusability (retaining ~87 % of response current after 100 days). The development of this new kind of laccase on a biosensor will offer a novel tool for substance detection applications in hostile environments, especially for industrial pollutants.  相似文献   

20.
《Electroanalysis》2006,18(21):2129-2136
A sol‐gel technique was used here to prepare a renewable carbon ceramic electrode modified with nickel powder. Cyclic voltammograms of the resulting modified electrode show stable and a well defined redox couple due to Ni(II)/Ni(III) system with surface confined characteristics. The modified electrode shows excellent catalytic activity toward L ‐cystine, L ‐cysteine and L ‐methionine oxidation at reduced overpotential in alkaline solutions. In addition the antifouling properties at the modified electrode toward the above analytes and their oxidation products increases the reproducibility of results. L ‐cystine, L ‐cysteine and L ‐methionine were determined chronoamperometricaly at the surface of this modified electrode at pH range 9–13. Under the optimized conditions the calibration curves are linear in the concentration range 1–450 μM, 2–90 μM and 0.2–75 μM for L ‐cystine, L ‐methionine and L ‐cysteine determination, respectively. The detection limit and sensitivity were 0.64 μM, 3.8 nA/ μM for L ‐cystine, 2 μM, 5.6 nA/ μM for L ‐methionine and 0.2 μM and 8.1 nA/μM for L ‐cysteine. The advantageous of this modified electrode is high response, good stability and reproducibility, excellent catalytic activity for oxidation inert molecules at reduced overpotential and possibility of regeneration of the electrode surface by potential cycling for 5 minutes. Furthermore, the modified electrode has been prepared without using specific reagents. This sensor can be used as an amperometric detector for disulfides detection in chromatographic or flow systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号