首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report the electrochemical behavior of a 4‐nitroimidazole derivative, 1‐methyl‐4‐nitro‐2‐hydroxymethylimidazole (4‐NImMeOH), on glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT). As dispersing agents, dimethylformamide (DMF) and water were used. The electrochemical response of the resulting electrodes was evaluated using linear sweep, cyclic and square‐wave voltammetry (LSV, CV and SWV). Several parameters such as medium pH, nature and concentration of the CNTs dispersion and accumulation time were tested. The optimal conditions determined for obtain better response were: pH 2, dispersion concentration=4 mg/mL of CNT in water, accumulation time=7 min. The MWCNT‐modified GCE exhibited attractive electrochemical properties producing enhanced currents with a significant reduction in the overpotential and good signal‐to‐noise characteristics, in comparison with the bare GCE. The modified electrode is highly repeatable for consecutive measurements, reaching a variation coefficient of 2.9% for ten consecutive runs.  相似文献   

2.
《Electroanalysis》2017,29(4):1049-1055
A sensitive electrochemical method for the determination and quantification of curcumin using adsorptive stripping voltammetry (AdsSV) at a multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode (MWCNT‐BPPG electrode) is presented exploiting the high surface area of the latter. Next the voltammetric behaviour of curcumin on the modified electrode is examined and AdsSV shown to be a sensitive method for quantifying curcumin. The adsorption of curcumin on the electrode surface is evidenced to follow a Langmuir adsorption isotherm. Linear calibration for curcumin in the range of 2–100 μM was obtained with a detection limit of 0.45 μM and a limit of quantification of 1.49 μM. For application to real samples of turmeric, a one‐step sample preparation in ethanol has developed providing a simple and rapid extraction procedure. The MWCNT‐BPPG electrode with AdsSV allowed the determination of curcumin equivalent in turmeric powder sample with recoveries in the range of 92–108 %. This facile and fast method will be useful for monitoring the quality of curcumin containing in commercial turmeric products.  相似文献   

3.
The electrochemical detection of the hazardous pollutant 4‐nitrophenol (4‐NP) at low potentials, in order to avoid matrix interferences, is an important research challenge. This study describes the development, electrochemical characterization and utilization of a multiwall carbon nanotube (MWCNT) film electrode for the quantitative determination of 4‐NP in natural water. Electrochemical impedance spectroscopy measurements showed that the modified surface exhibits a decrease of ca. 13 times in the charge transfer resistance when compared with a bare glassy carbon (GC) surface. Voltammetric experiments showed the possibility to oxidize a hydroxylamine layer (produced by the electrochemical reduction of 4‐NP on the GC/MWNCT surface) in a potential region which is approximately 700 mV less positive than that needed to oxidize 4‐NP, thus minimizing the interference of matrix components. The limit of detection for 4‐NP obtained using square‐wave voltammetry (0.12 μmol L?1) was lower than the value advised by EPA. A natural water sample from a dam located in São Carlos (Brazil) was spiked with 4‐NP and analyzed by the standard addition method using the GC/MWCNT electrode, without any further purification step. The recovery procedure yielded a value of 96.5% for such sample, thus confirming the suitability of the developed method to determine 4‐NP in natural water samples. The electrochemical determination was compared with that obtained by HPLC with UV‐vis detection.  相似文献   

4.
The electrochemical oxidation of naproxen was investigated at a multiwalled carbon nanotube (MWCNT)‐modified electrode. A decrease (200 mV) in the overpotential of the naproxen oxidation reaction and considerable (4‐fold) current increase (compared to the bare glassy‐carbon electrode) was observed. Two one‐electron transfers were verified at both bare and MWCNT‐modified electrodes and thus a new mechanism for the electrochemical oxidation of naproxen is proposed. Indicative of a mass transport regime that includes a thin‐layer diffusional process (entrapment of naproxen species within the MWCNT film) is presented as a possible explanation for the lowered oxidation potential and substantial current increase. The anti‐fouling properties of MWCNTs on the amperometric detection of naproxen using a batch‐injection analysis (BIA) system is demonstrated.  相似文献   

5.
《Electroanalysis》2004,16(20):1697-1703
An amperometric glucose biosensor based on multi‐walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT‐modified glassy carbon electrode was obtained by casting the electrode surface with multi‐walled carbon nanotube materials. Glucose oxidase was co‐immobilized on the MWCNT‐modified glassy carbon surface by electrochemical deposition of poly(o‐phenylenediamine) film. Enhanced catalytic electroreduction behavior of oxygen at MWCNT‐modified electrode surface was observed at a potential of ?0.40 V (vs. Ag|AgCl) in neutral medium. The steady‐state amperometric response to glucose was determined at a selected potential of ?0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4‐acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.  相似文献   

6.
The voltammetric behavior of dopamine (DA) and uric acid (UA) on a gold electrode modified with self‐assembled monolayer (SAM) of cysteamine (CA) conjugated with functionalized multiwalled carbon nanotubes (MWCNTs) was investigated. The film modifier of functionalized SAM was characterized by means of scanning electron microscopy (SEM) and also, electrochemical impedance spectroscopy (EIS) using para‐hydroquinone (PHQ) as a redox probe. For the binary mixture of DA and UA, the voltammetric signals of these two compounds can be well separated from each other, allowing simultaneous determination of DA and UA. The effect of various experimental parameters on the voltammetric responses of DA and UA was investigated. The detection limit in differential pulse voltammetric determinations was obtained as 0.02 µM and 0.1 µM for DA and UA, respectively. The prepared modified electrode indicated a stable behavior and the presence of surface COOH groups of the functionalized MWCNT avoided the passivation of the electrode surface during the electrode processes. The proposed method was successfully applied for the determination of DA and UA in urine samples with satisfactory results. The response of the gold electrode modified with MWCNT‐functionalized SAM method toward DA, UA, and ascorbic acid (AA) oxidation was compared with the response of the modified electrode prepared by the direct casting of MWCNT.  相似文献   

7.
We report a rapid and simple method for sensing estradiol by electro‐oxidation on a multi‐walled carbon nanotube (MWCNT) and gold nanoparticle (AuNP) modified glassy carbon electrode (GCE). Compared with a bare GCE, AuNP/GCE and MWCNT/GCE, the composite modified GCE shows an enhanced response to estradiol in 0.1 M phosphate buffer solution. Experimental parameters, including pH and accumulation time for estradiol determination were optimised at AuNP/MWCNT/GCE. A pH of 7.0 was found to be optimum pH with an accumulation time of 5 minutes. Estradiol was determined by linear sweep voltammetry over a dynamic range up to 20 %mol L?1 and the limit of detection was estimated to be 7.0×10?8 mol L?1. The sensor was successfully applied to estradiol determination in tap water and waste water.  相似文献   

8.
《Electroanalysis》2006,18(12):1179-1185
The electrochemical behavior of human breast cancer cells (MCF‐7) suspension on multiwalled carbon nanotube (MWCNT) modified graphite electrode was studied by using cyclic voltammetry (CV) and potentiometric stripping analysis (PSA). Compared with bare graphite electrode, the MWCNTs‐modified electrode showed electrocatalytic property to the oxidation of electroactive species in the cell suspension. One oxidative peak at about +0.74 V was observed in the cyclic voltammogram. PSA was proved to be more sensitive than CV for investigation of the electrochemical behavior of cells. And it was found that ultrasonication treatment of the cell suspension can significantly enhance the PSA signal. Factors influencing the PSA signal of cells, including deposition time, deposition potential and stripping current, were investigated in detail and the optimum conditions were obtained. The baseline corrected PSA signal was found to be related to the viability of cells and the technique was used for monitoring the growth of MCF‐7 cells. The effect of anticancer drug 5‐fluorouracil (5‐FU) on the growth of MCF‐7 cells was also investigated by PSA.  相似文献   

9.
The electrochemical reduction of three common insecticides such as cypermethrin (CYP), deltamethrin (DEL) and fenvalerate (FEN) was investigated at glassy carbon electrode (GCE), multiwalled carbon nanotubes modified GCE (MWCNT‐GCE), polyaniline (herein called as modifier M1) and polypyrrole (herein called as modifier M2) deposited MWCNT/GCE using cyclic voltammetry. Influences of pH, scan rate, and concentration were studied. The surface morphology of the modified film was characterized by scanning electron microscopy (SEM) and X‐ray diffraction analysis (XRD). A systematic study of the experimental parameters that affect differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived at. The calibration plots were linear over the insecticide's concentration range 0.1–100 mg L?1 and 0.05–100 mg L?1 for all the three insecticides at MWCNT‐GCE and MWCNT(M1)‐GCE respectively. The MWCNT(M2)‐GCE performed well among the three electrode systems and the determination range obtained was 0.01–100 mg L?1 for CYP, DEL and FEN. The limit of detection (LOD) was 0.35 μg L?1, 0.9 μg L?1 and 0.1 μg L?1 for CYP, DEL and FEN respectively on MWCNT(M2)‐GCE modified system. Suitability of this method for the trace determination of insecticide in spiked soil sample was also determined.  相似文献   

10.
A new voltammetric sensor based on molecularly imprinted poly(acrylic acid)‐MWCNT nanocomposite (MIP‐MWCNT) drop‐coated onto glassy carbon electrode (GCE) was developed and applied to tramadol (TR) determination in pharmaceutical samples. The voltammetric sensor prepared by suspension of MIP‐MWCNT at 1 : 1 (w/w) ratio show an improved performance compared to unmodified GCE. The electrochemical method is based on preconcentration of tramadol onto MIP‐MWCNT modified GCE surface at ?1.5 V vs Ag/AgCl for 180 s in 0.1 Britton‐Robinson buffer (pH 8.0) at stirred solution. Upon preconcentration, the differential anodic voltammogram was recorded under the optimized condition giving rise to an analytical curve varying from 9.0 up to 30.0 μmol L?1 (R2=0.997) and limits of detection and quantification of 1.4 and 4.8 μmol L?1, respectively. The method precision was assessed in terms of intraday (n=6) and interday (two consecutive days) precision, giving relative standard deviations (RSD%) values between 2.8 to 7.4 %. Excipients usually found in pharmaceutical pills (magnesium stearate, microcrystalline cellulose, starch, and silica) and paracetamol were evaluated as potential interferents, however no interference was evidenced in TR determination. The method applicability was evaluated by TR analysis in pharmaceutical samples. Moreover, the method accuracy was attested by comparison of addition and recovery assays with a reference technique (high‐performance liquid chromatography).  相似文献   

11.
Electrochemical capacitive behaviour of the electropolymeric nickel tetra‐aminophthalocyanine (poly‐NiTAPc) supported on multiwalled carbon nanotube (MWCNT) platform is described. From the data in 1 M H2SO4, the MWCNT‐poly‐NiTAPc exhibited superior capacitance (112 mF cm?2 or 777 F g?1). The supercapacitance of the MWCNT‐polyNiTAPc was found to be much better in 1 M H2SO4 than in 1 M NaOH medium. Impedance data proved that most of the stored energy of the MWCNT‐poly‐NiTAPc could be accessible at high frequency (1.6 kHz). The electrode is capable of undergoing continuous charge‐discharge process for more than a 1000 cycles without any significant deterioration in the stability.  相似文献   

12.
The present work describes preparation of hemoglobin‐incorporated multiwalled carbon nanotubes‐poly‐L ‐lysine (MWCNT‐PLL)/Hb) composite modified electrode film modified glassy carbon electrode (GCE) and its electrocatalytic behavior towards reduction of bromate ( ) in 0.1 M acetate buffer (pH 5.6). The modified electrode has been successfully fabricated by immobilizing hemoglobin on MWCNT dispersed in poly‐L ‐lysine. The surface morphologies of MWCNT, PLL and Hb were characterized using atomic force microscopy (AFM). The voltammetric features suggested that the charge transport through the film was fast and the electrochemical behavior resembles that of surface‐confined redox species. Cyclic voltammetry was used to investigate the electrocatalytic behavior of the modified electrode towards bromate and was compared with that of the CNT‐modified as well as bare electrode. The analytical determination of bromate has been carried out in stirred solution at an optimized potential with a sensitivity of 7.56 μA mM?1 and the calibration curve was linear between 1.5×0?5 to 6.0×0?3 M.  相似文献   

13.
An electrochemical method for the determination of tripelennamine hydrochloride (TPA) using cetyltrimethylammoniumbromide‐multiwalled carbon nanotubes modified glassy carbon electrode (MWCNT‐CTAB/GCE) was developed. Because of good electrical conductivity of MWCNT and catalytic behavior of CTAB, new electrode significantly enhances the sensitivity for the detection of TPA. Parameters such as amount of modifier suspension, scan rate, pH of measure solution, heterogeneous rate constant were investigated. The electrode exhibits a linear potential response in the range of 1.0×10?8 M to 3.0×10?6 M with a detection limit of 2.38× 10?9 M. The modified electrode was successfully applied to the determination of TPA in pharmaceutical and real samples.  相似文献   

14.
The preparation of Hg(II)-modified multi walled carbon nanotube (MWCNT) by reaction of oxidized MWCNT with aqueous HgCl2 was carried out. The Hg(II)-modified multi walled carbon nanotube (Hg(II)/MWCNT) dispersed in Nafion solution was used to coat the polished graphite electrode surface. The Hg(II)/MWCNT modified graphite electrode was held at a cathodic potential (−1.0 V) to reduce the coordinated Hg(II) to Hg forming nanodroplets of Hg. The modified electrode was characterized by FESEM/EDAX which provided useful insights on the morphology of the electrode. The SEM images showed droplets of Hg in the size of around 260 nm uniformly distributed on the MWCNT. Differential pulse anodic stripping voltammetry (DPASV) and electrochemical impedance spectroscopy were used to study the Hg(II) binding with MWCNT. Differential pulse anodic stripping voltammetry of ppb levels of cadmium and lead using the modified electrode yielded well-defined peaks with low background current under a short deposition time. Detection limit of 0.94 and 1.8 ng L−1 were obtained following a 3 min deposition for Pb(II) and Cd(II), respectively. Various experimental parameters were characterized and optimized. High reproducibility was observed from the RSD values for 20 repetitive measurements of Pb(II) and Cd(II) (1.7 and 1.9%, respectively). The determination of Pb(II) and Cd(II) in tap water and Pb(II) in human hair samples was carried out. The above method of fabrication of Hg(II)/MWCNT modified graphite electrode clearly suggests a safe route for preparing Hg immobilized electrode for stripping analysis.  相似文献   

15.
The present work describes the development of a selective and sensitive voltammetric sensor for simultaneous determination of catechol (CC) and hydroquinone (HQ), based on a glassy carbon (GC) electrode modified with manganese phthalocyanine azo‐macrocycle (MnPc) adsorbed on multiwalled carbon nanotubes (MWCNT). Scanning electron microscopy and scanning electrochemical microscopy were used to characterize the composite material (MnPc/MWCNT) on the glassy carbon electrode surface. The modified electrode showed excellent electrochemical activity towards the simultaneous oxidation and reduction of CC and HQ. On the MnPc/MWCNT/GC electrode, both CC and HQ can generate a pair of quasi‐reversible and well‐defined redox peaks. Under optimized experimental and operational conditions, the cathodic peak currents were linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.095 and 0.041 µmol L?1, respectively. The anodic peak currents were also linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.096 and 0.048 µmol L?1, respectively. The proposed method was effectively applied for the simultaneous detection of hydroquinone and catechol in water samples and the results were in agreement with those obtained by a comparative method described in the literature.  相似文献   

16.
We report the adsorptive voltammetric determination of nifedipine on multiwalled carbon nanotubes (MWCNT)‐modified glassy carbon electrode (GCE). Nifedipine was adsorbed on the MWCNT and then reduced using linear sweep and cyclic voltammetry (LSV and CV). Parameters such as pH and accumulation time were tested. The MWCNT‐modified GCE showed enhanced currents and good signal‐to‐noise characteristics in comparison with the bare GCE. Consecutive measurements with the modified electrode were highly repeatable and reproducible. The MWCNT/GCE was used for the determination of nifedipine and is recommended for quantitation in dissolution test studies. In this study we have tested normal and extended‐release pharmaceutical formulations of nifedipine using USP apparatus 2 and tracking the released drug in solution by the proposed voltammetric method. The main advantage of the voltammetric determination is the feasibility to detect the drug in‐situ avoiding tedious intermediate steps such as filtration, collection and replenishment of sample solutions. This work seeks to demonstrate the feasibility of applying voltammetric techniques in dissolution test studies.  相似文献   

17.
In this study, interaction of tetracycline (TC) and DNA in the Britton? Robinson buffer solution (BR) was studied by cyclic voltammetry. The experimental results reveal that TC can bind strongly to DNA and the association constant and binding number between TC and DNA was obtained. Then DNA was immobilized on a glassy carbon electrode by UV‐irradiation. Through this process, water‐soluble DNA was converted into insoluble materials, and a stable DNA film was formed on the electrode. The electrochemical oxidation behavior of TC was studied at UV‐irradiated DNA film modified glassy carbon electrode (UV‐DNA‐GCE). The response of modified electrode was optimized with respect to pH, accumulation time, ionic strength, drug concentration and other variables. TC at the surface of modified electrode showed a linear dynamic range of 0.30–90.00 µM and a detection limit of 0.27 µM. To demonstrate the applicability of the modified electrode, it was used for the analysis of real samples such as pharmaceutical formulations and milk.  相似文献   

18.
《Electroanalysis》2004,16(11):881-887
s‐Adenosyl‐L ‐methionine (SAMe) is an adenosine analogue with therapeutical activity against affective disorders and liver dysfunctions. It can be oxidized on graphite electrode yielding a strongly adsorbed electroactive oxidation product for which a quinone‐imine structure is proposed. This compound is capable of electrocatalyzing the NADH oxidation at low potentials, lowering the overvoltage by about 300 mV. An amperometric method for NADH determination at +0.1 V (Ag|AgCl|KClsat) is developed using an oxidized‐SAMe‐modified electrode in pH 9. Linear calibration plots were obtained with a detection limit of 2.4 nM. The electrode response time and the relative standard deviation of the slope of the calibration plot for 5 different modified electrodes were 12 s and 5.6% respectively. The catalytic scheme also provides the first method to determine SAMe itself by adsorptive differential pulse voltammetry. The linear range was found to be 42.4–424 nM with a reproducibility of 6.9%. The method was applied to SAMe determination in a pharmaceutical formulation.  相似文献   

19.
建立了碳纳米管修饰电极-人工神经网络同时检测-氯酚三种异构体的方法.在pH=7.0的磷酸盐缓冲溶液中,邻氯酚、间氯酚和对氯酚在碳纳米管修饰电极上均有一灵敏的不可逆氧化峰.采用微分脉冲溶出伏安法,在优化的实验条件下,邻氯酚、间氯酚和对氯酚的峰电位分别为624 mV、712 mV和632 mV,且浓度分别在2.07~103...  相似文献   

20.
A very effective electrochemical sensor for the analysis of propranolol was constructed using TiO2/MWCNT film deposited on the pencil graphite electrode as modifier. The modified electrode represented excellent electrochemical properties such as fast response, high sensitivity and low detection limit. The proposed sensor showed an excellent selective response to propranolol in the presence of foreign species and other drugs. The electrochemical features of the modified electrode were investigated by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) technique which indicated a decrease in resistance of the modified electrode versus bare PGE and MWCNT/PGE. The surface morphology for the modified electrode was determined by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT-IR). Differential pulse technique (DPV) was used to determine propranolol which showed a good analytical response in the linear range of 8.5×10−8-6.5×10−6 M with a limit of detection 2.1×10−8 M. The TiO2/MWCNT/PGE sensor was conveniently applied for the measurement of propranolol in biological and pharmaceutical media.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号