首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Simultaneous kinetic‐spectrophotometric determination of a ternary mixture of hydrazine (HZ) and its derivatives by principal component regression (PCR) and partial least squares (PLS) calibration is described. The methods were based on the difference observed in the reduction rate of iron(III) with HZ, thiosemicarbazide (TSCZ) and phenylhydrazine (PHZ) in the presence of 2,2′‐bipyridine (Bpy). The colored complex of [Fe(Bpy)3]2+ was formed in sodium dodecyl sulfate (SDS) as micellar media, and then monitored at 520 nm. The results showed that simultaneous determination of HZ, TSCZ and PHZ could be performed in their concentration ranges of 1.0–70.0, 0.2–6.0 and 0.1–10.0 μg mL?1, respectively. The root mean squares errors of prediction (RMSEP) of HZ, TSCZ and PHZ were 0.719, 0.164 and 0.105 (for PLS) 0.788, 0.166 and 0.993 (for PCR), respectively. Both methods (PCR and PLS) were validated using a set of synthetic sample mixtures and then applied for simultaneous determination of HZ, TSCZ and PHZ in water samples.  相似文献   

2.
Simultaneous determination of hydrazine (HZ) and phenylhydrazine (PHZ) by H-point standard addition method (HPSAM) and partial least squares (PLS) regression was carried out based on kinetic data from novel potentiometry methods. The rate of chloride ion production in the reaction of HZ and PHZ with N-chlorosuccinimide (NCS) was monitored by a chloride ion-selective electrode. The experimental data show the good ability of ion-selective electrodes (ISEs) as detectors not only for the direct determination of chloride ion but also for simultaneous kinetic-potentiometric analysis using HPSAM and PLS methods. The methods are based on the differences observed in the production rate of chloride ions. The results show that simultaneous determination of HZ and PHZ can be performed in concentration ranges of 0.5 - 20.0 and 0.8 - 25.0 microg mL(-1), respectively. The total relative standard error for applying the PLS method to 8 synthetic samples in the concentration ranges of 1.0 - 16.0 microg mL(-1) for HZ and 2.0 - 16.0 microg mL(-1) for PHZ was 3.96. In order for the selectivity of the method to be assessed, we evaluated the effects of certain foreign ions upon the reaction rate and assessed the selectivity of the method. Both methods (PLS and HPSAM) were evaluated using a set of synthetic sample mixtures and then applied for simultaneous determination of HZ and PHZ in water samples.  相似文献   

3.
A second‐derivative spectrophotometric method based on zero‐crossing over technique is developed in simultaneous determination of copper(II) and nickel(II) ions. Methylthymol blue (MTB) as a chromogenic reagent and cetyltrimethylammonium bromide as a surfactant were used, and measurements were carried out in buffered solution at pH 6 and at a temperature of 25 °C. The amplitude of derivative spectra was measured at wavelengths of 631.9 and 587.7 nm for the simultaneous determination of Ni2+ and Cu2+, respectively. Linearity was obtained in the range of 0.5–5.0 μg mL?1 for both ions in the presence of 0.0–5.0 μg mL?1 of the other ion as an interfering ion. IUPAC detection limits for Cu2+ and Ni2+ ions were obtained at 0.48 and 0.43 μg mL?1, respectively. The proposed procedure has been applied successfully for the simultaneous determination of copper and nickel in synthetic binary mixtures and real samples.  相似文献   

4.
A very simple spectrophotometric method for simultaneous determination of aluminum(III) and iron(III) based on formation of their complexes with pyrocatechol violet (PCV) in micellar media, using the H‐point standard addition method (HPSAM), is described. In micellar media, the metal complexes of Al‐PCV and Fe‐PCV are formed very fast. Formation of both of the complexes was complete within 5 min at pH 8.5. The linear ranges for aluminum and iron were 0.05‐2.50 and 0.10‐4.00 μg mL?1, respectively. The relative standard deviation (R.S.D.) for the simultaneous determination 0.40 μg mL?1 of Al(III) and 0.20 μg mL?1 of Fe(III) were 3.24% and 4.22%, respectively. Interference effects of common anions and cations were studied. The method was applied to simultaneous determination of Al(III) and Fe(III) in standard reference material and alloy samples.  相似文献   

5.
Simultaneous kinetic-potentiometric determination of binary mixture of permanganate (MnO4 ?) and dichromate (Cr2O7 2?) by H-point standard addition method (HPSAM), partial least squares (PLS) and principal component regression (PCR) is described. In this work, the difference between the rate of the oxidation reaction of Fe(II) to Fe(III) in the presence of MnO4 ? and Cr2O7 2? formed the basis of the method. The rate of the consumed fluoride ion for making the complex was detected by a fluoride ion selective electrode (FISE). The results show that the simultaneous determination of MnO4 ? and Cr2O7 2? could be conducted in their concentration ranges of 0.5?C10.0 and 0.1?C20.0 ??g ml?1, respectively. The total relative standard error (RSE) for applying the PLS and PCR methods to 9 synthetic samples was 5.30 and 3.17, respectively in the concentration range of MnO4 ?, and 3.30 and 2.04, respectively, in the concentration range of Cr2O7 2?. In order for the selectivity of the method to be assessed, we evaluated the effects of certain foreign ions upon the reaction rate. The proposed methods (HPSAM, PLS and PCR) were evaluated using a set of synthetic sample mixtures and then applied to the simultaneous determination of MnO4 ? and Cr2O7 2? in different water samples.  相似文献   

6.
An adsorptive differential pulse stripping method for the simultaneous determination of lead and tin is proposed. The procedure involves an adsorptive accumulation of lead and tin on a hanging mercury drop electrode (HMDE), followed by oxidation of adsorbed lead and tin by voltammetric scan using differential pulse modulation. The optimum experimental conditions are: 0.2 mol L?1 HNO3, accumulation potential of ?900 mV versus Ag/AgCl, accumulation time of 200 s, scan rate of 20 mV s?1 and pulse height of 80 mV. Lead and tin peak currents were observed in the same potential region at about ?400 mV. The simultaneous determination of lead and tin by using voltammetry is a difficult problem in analytical chemistry, due to voltammogram interferences. The resolution of a mixture of lead and tin by the application of orthogonal signal correction‐partial least squares (OSC‐PLS) was performed. The linear dynamic ranges were 0.003‐0.35 and 0.008‐0.50 μg mL?1 and detection limits were land 3 ng mL?1 for lead and tin, respectively. The RMSEP for lead and tin with OSC and without OSC were 2.8737, 6.0557 and 8.0941, 9.5151, respectively. The capability of the method for the analysis of real samples was evaluated by the determination of lead and tin in water samples with satisfactory results.  相似文献   

7.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

8.
Two simple and sensitive extractive spectrophotometric methods have been described for the analysis of clarithromycin in pure form and in pharmaceutical formulations. The methods involved formation of yellow colored chloroform extractable ion‐association complexes of clarithromycin with bromothymol blue (BTB) and cresol red (CR) in buffered aqueous solution at pH 4. The extracted complexes showed maximum absorbance at 410 and 415 nm for BTB and CR, respectively. Beer's law is obeyed in the concentration ranges 0.1–20 μg mL?1 and 2.0–20 μg mL?1 of clarithromycin with molar absorptivity of 2.01 × 104 and 4.378 × 103 for BTB and CR, respectively. The composition ratio of the ion‐association complex was clarithromycin: BTB and CR = 1:1 as established by Job's method. The methods have been applied to the determination of drug in commercial formulations. The results of analysis were validated statistically and through recovery studies.  相似文献   

9.
《Analytical letters》2012,45(4):751-761
Abstract

A partial least‐squares calibration (PLS) method has been developed for simultaneous quantitative determination of mepyramine maleate (MAM), lidocaine hydrochloride (LIH), and dexpanthenol (DPA) in pharmaceutical preparations. The resolution of these mixtures has been accomplished by using partial least‐squares (PLS‐2) regression analysis of electronic absorption spectral data without prior separation or derivatization. The experimental calibration matrix was constructed with 27 samples. The concentration ranges considered were 2, 3, 4 µg mL?1 for MAM, 2, 3, 4 µg mL?1 for LIH, and 8, 10, 12 µg mL?1 for DPA. The absorbances were recorded between 190 and 340 nm every 5 nm. The results show that PLS‐2 is a simple, rapid, and accurate method applied to the determination of these compounds in pharmaceuticals.  相似文献   

10.
The mean centering of ratio kinetic profiles method was used for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) in water samples, without prior separation steps. The method is based on the difference in the rate of the reaction of Ni(II) and Zn(II) with xylenol orange at pH 5.3. The method allows rapid and accurate determination of Ni(II) and Zn(II). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) were calculated. The linear range was 0.025‐2.400 μg mL?1 and 0.025‐2.20 μg mL?1 for Zn(II) and Ni(II), respectively. Interference effects of common anions and cations were studied, and the method was successfully applied to the simultaneous determination of Zn(II) and Ni(II) in water samples.  相似文献   

11.
The interaction between anionic surfactants (AS) and 1‐hexadecyl‐3‐methylimidazolium bromide [C16mim]Br was studied by using resonance light scattering (RLS) technique, UV‐Vis spectrophotometry and fluorometric methods. In Britton Robinson (BR) buffer (pH 6.0), [C16mim]Br reacted with AS to form supermolecular complex which resulted in enhancement in RLS intensity. Their maximum RLS wavelengths were all at 390 nm. Some important interacting experimental variables, such as the solution acidity, [C16mim]Br concentration, salt effect and addition order of the reagents, were investigated and optimized. Under the optimum conditions, quantitative determination ranges were 0.001–7 μg·mL?1 for dodecyl sodium sulfate (SDS), 0.001–6 μg·mL?1 for sodium dodecylbenzene sulfonate (SDBS) and 0.005–7 μg·mL?1 for sodium lauryl sulfonate (SLS), respectively, while the detection limits were 1.3 ng·mL?1 for SDS, 1.0 ng·mL?1 for SDBS and 5.1 ng·mL?1 for SLS, respectively. Based on the ion‐association reaction, a highly sensitive, simple and rapid method has been established for the determination of AS.  相似文献   

12.
Three simple, sensitive and accurate spectrophotometric methods have been developed for the determination of dextromethorphan hydrobromide (DEX) and ketamine hydrochloride (KET) in dosage forms. These methods are based on the formation of ion‐pair complexes with bromocresol green (BCG), bromocresol purple (BCP), and bromophenol blue (BPB) in acidic medium. The coloured ion‐pair products are measured at 419, 409 and 417 nm for DEX and at 417, 408 and 416 nm for KET using BCG, BCP and BPB, respectively. Beer's law was obeyed in the range of 2.0–22 μg mL?1 for DEX and 2.0–16 μg mL?1 for KET. The composition of the ion‐pair was established by continuous variation and molar ratio methods. The proposed methods were applied successfully for the determination of DEX and KET in dosage forms applying the standard addition technique and compared statistically with the official methods. The molar absorptivity, Sandell sensitivity, detection and quantification limits were also calculated.  相似文献   

13.
A simple, sensitive, and rapid microextraction method, namely, ultrasound‐assisted surfactant‐enhanced emulsification microextraction based on the solidification of floating organic droplet method coupled with high‐performance liquid chromatography was developed for the simultaneous preconcentration and determination of nitrazepam and midazolam. The significant parameters affecting the extraction efficiency were considered using Plackett–Burman design as a screening method. To obtain the optimum conditions with consideration of the selected significant variables, a Box–Behnken design was used. The microextraction procedure was performed using 29.1 μL of 1‐undecanol, 1.36% (w/v) of NaCl, 10.0 μL of sodium dodecyl sulfate (25.0 μg mL?1), and 1.0 μL of Tween80 (25.0 μg mL?1) as an emulsifier in an extraction time of 20.0 min at pH 7.88. In order to investigate the validation of the developed method, some validation parameters including the linear dynamic range, repeatability, limit of detection, and recoveries were studied under the optimum conditions. The detection limits of the method were 0.017 and 0.086 ng mL?1 for nitrazepam and midazolam, respectively. The extraction recovery percentages for the drugs studied were above 91.0 with acceptable relative standard deviation. The proposed methodology was successfully applied for the determination of these drugs in a number of human serum samples.  相似文献   

14.
《Analytical letters》2012,45(4):563-581
Abstract

The color reaction between Xylenol orange (XO), zirconium (IV) and fluoride ions in the presence of various surfactants alone or in combination was studied at various pH. The XO -zirconium)IV)-fluoride ion ternary complex in mixed micellar media containing a low concentration of N-hexadecylpyridinium chloride (HPC) as a cationic surfactant and large amounts of (poly{oxyethylene)dodecyl ether (Brij 35) as a nonionic surfactant at weakly acidic media was found to be the most stable, and showed a remarkable bathochromic shift and clear contrast against a reagent blank. The maximum absorbance was at 600 nm in the mixed micellar media at pH 3.5, and the apparent molar absorptivities at 600 nm were 7.0 × 104 1 mol?1 cm?1 for zirconium(IV) and 1.4 × 104 1 mol?1 cm?1 for fluoride ion. The calibration curves covered the ranges of 0.5 ~ 20.0 μg/10 ml zirconium! IV) and 0 ~ 20.0 μg/10 ml fluoride ion with the Sandell sensitivities being 0.0013 μg/cm2 for zirconium(IV) and 0.0016 μg/cm2 for fluoride ion.  相似文献   

15.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

16.
A new one‐shot optical cyanide ion sensor is proposed for determination of cyanide ions. The sensor was constructed by immobilizing crystal violet (CV) on triacetylcellulose membrane. The sensing mechanism involves reaction between cyanide ions and the immobilized CV at pH = 5.4, which results in a decrease in absorbance of the membrane at 600 nm. The sensor shows sufficient repeatability, reproducibility, operational lifetime of 3 weeks, and a response of less then 10 min under the optimum conditions and response time of 8 min. Cyanide can be determined in the concentration range of 50.0‐800 μg mL‐1 with a detection limit of 5.0 μg mL‐1. Most ions do not interfere with the determination of cyanide ions. The proposed sensor was successfully applied to the determination of cyanide in spiked water samples.  相似文献   

17.
In this work, a new method has been proposed to simultaneously determine V(V), Co(II) and Cu(II) ions from aqueous solution by spectrophotometry after cloud point extraction using partial least squares regression (PLS). The metal ions in 10 ml of aqueous solution (containing 0.2 M sodium acetate buffer solution, pH 3.5) were formed complexes with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). Then, Triton X-114 (2 %, v/v) was added to the solution. By increasing the temperature of the solution up to 55 °C, a phase separation occurred. After centrifugation at 3,000 rpm for 10 min, the surfactant-rich phase was dissolved and diluted to 0.5 mL with ethanol. The metal ions were then determined using spectrophotometry. At these optimal extraction and operating conditions, linearity was obeyed in the range 7–300, 3–100 and 15–700 ng mL?1 of V(V), Co(II) and Cu(II), with the detection limit of 2.2, 1.0 and 4.5 ng mL?1, respectively. The relative predictive error for the simultaneous determination of 15 test samples of different concentrations of V(V), Co(II) and Cu(II) was 3.28, 3.64 and 4.04 %, respectively. The root mean square error of prediction for applying the PLS method to 15 synthetic samples in the linear ranges of these metal ions was 3.4, 1.6 and 18.1 ng mL?1. The interference effect of some anions and cations was also tested. The proposed method has been applied successfully to the simultaneous determination of V(V), Co(II) and Cu(II) ions in real matrix samples with the recoveries of 96.75–104.80 %.  相似文献   

18.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

19.
In this article a sensitive differential pulse stripping voltammetry technique on Nafion‐coated bismuth‐film electrode (NCBFE) was studied for the simultaneous determination of zinc, cadmium, and lead ions in blood samples at ultra trace levels. The measurement results were in excellent agreement with those obtained from atomic absorption spectroscopy. Various operational parameters were investigated and discussed in terms of their effect on the measurement signals. Under optimal conditions, calibration curves for the simultaneous determination of zinc, cadmium, and lead ions were achieved, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L?1 for Cd(II), 0.13 μg L?1 for Pb(II), and 0.97 μg L?1 for Zn(II) respectively.  相似文献   

20.
A simple and reliable method for simultaneous spectrophotometric determination of iron(II) and cobalt(II) has been established. The method is based on complex formation with 1‐(2‐pyridylazo)‐2‐naphtol (PAN) in a micellar medium. Despite a spectral overlap, Fe2+ and Co2+ have been simultaneously determined with chemometric approaches involving principal component artificial neural network (PC‐ANN), principal component regression (PCR) and partial least squares (PLS). Various synthetic mixtures of iron and cobalt were assessed and the results obtained by the applications of these chemometric approaches were evaluated and compared. It was found that the PC‐ANN method afforded relatively better precision than that of PCR or PLS. The proposed method permits detection limits of 0.05 and 0.07 ng mL?1 for Co and Fe, respectively. The influences of pH, ligand amount, solvent percentage and time on the absorbance were also investigated. The proposed method was also applied satisfactorily for the determination of Fe(II) and Co(II) in real and synthetic samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号