首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexafluorophosphate, BMIMPF6)‐single‐walled carbon nanotube (SWNT) gel modified glassy carbon electrode (BMIMPF6‐SWNT/GCE) is fabricated. At it the voltammetric behavior and determination of p‐nitroaniline (PNA) is explored. PNA can exhibit a sensitive cathodic peak at ?0.70 V (vs. SCE) in pH 7.0 phosphate buffer solution on the electrode, resulting from the irreversible reduction of PNA. Under the optimized conditions, the peak current is linear to PNA concentration over the range of 1.0×10?8–7.0×10?6 M, and the detection limit is 8.0×10?9 M. The electrode can be regenerated by successive potential scan in a blank solution for about 5 times and exhibits good reproducibility. Meanwhile, the feasibility to determine other nitroaromatic compounds (NACs) with the modified electrode is also tested. It is found that the NACs studied (i.e., p‐nitroaniline, p‐nitrophenol, o‐nitrophenol, m‐nitrophenol, p‐nitrobenzoic acid, and nitrobenzene) can all cause sensitive cathodic peaks under the conditions, but their peak potentials and peak currents are different to some extent. Their peak currents and concentrations show linear relationships in concentration ranges with about 3 orders of magnitude. The detection limits are 8.0×10?9 M for p‐nitroaniline, 2.0×10?9 M for p‐nitrophenol, 5.0×10?9 M for o‐nitrophenol, 5.0×10?9 M for m‐nitrophenol, 2.0×10?8 M for p‐nitrobenzoic acid and 8.0×10?9 M for nitrobenzene respectively. The BMIMPF6‐SWNT/GCE is applied to the determination of NACs in lake water.  相似文献   

2.
A novel electrochemical sensor for sensitive detection of methyldopa at physiological pH was developed by the bulk modification of carbon paste electrode (CPE) with graphene oxide nanosheets and 3‐(4′‐amino‐3′‐hydroxy‐biphenyl‐4‐yl)‐acrylic acid (3,′AA). Applying square wave voltammetry (SWV), in phosphate buffer solution (PBS) of pH 7.0, the oxidation current increased linearly with two concentration intervals of methyldopa, one is 1.0×10?8–1.0×10?6 M and the other is 1.0×10?6–4.5×10?5 M. The detection limit (3σ) obtained by SWV was 9.0 nM. The modified electrode was successfully applied for simultaneous determination of methyldopa and hydrochlorothiazide. Finally, the proposed method was applied to the determination of methyldopa and hydrochlorothiazide in some real samples.  相似文献   

3.
The electrochemical behavior of aloe‐emodin (AE), an important herbal antitumor drug, was investigated at a carbon‐coated nickel magnetic nanoparticles modified glassy carbon electrode (CNN/GCE). A couple of well‐defined redox peaks was obtained. Some electrochemical parameters of AE at a CNN/GCE, such as the charge number, exchange current density, standard heterogeneous rate constant, were measured. The square wave voltammetry (SWV) response of AE was linear with the concentration over two concentration intervals viz. 6.24×10?9?1.13×10?6 M and 1.13×10?6?1.23×10?5 M, with a detection limit of 2.08 nM. A fast, simple and sensitive detection and analysis of AE was developed.  相似文献   

4.
A 1‐[2‐hydroxynaphthylazo]‐6‐nitro‐2‐naphthol‐4‐sulfonate/ CuO nanoparticles modified carbon paste electrode (HNNSCCPE) was constructed and the electro‐oxidation of isoprenaline at the surface of the modified electrode was studied using cyclic voltammetry (CV), chronoamperometry (CHA), and square wave voltammetry (SWV). Under the optimized conditions, the square wave voltammetric peak current of isoprenaline increased linearly with isoprenaline concentrations in the range of 1.0×10?7 to 7.0×10?4 M and detection limit of 5.0×10?8 M was obtained for isoprenaline. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of isoprenaline, acetaminophen and N‐acetyl‐L‐cysteine which makes it suitable for the detection of isoprenaline in the presence of acetaminophen and N‐acetyl‐L‐cysteine in real samples.  相似文献   

5.
A glassy carbon electrode coated the film of 4‐tert‐butyl‐1‐(ethoxycarbonylmethoxy)thiacalix[4]arene is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode, the modified electrode can improve the measuring sensitivity of Hg2+. Under the optimum experimental condition, the modified electrode in 0.1 mol L?1 H2SO4 + 0.01 mol L?1 KCl solution shows a linear voltammetric response in the range of 8.0 × 10?9 ~ 3.0 × 10?6 mol L?1 with detection limit 5.0 × 10?9 mol L?1 for Hg2+. The high sensitivity, selectivity, and stability of modified electrode also prove its practical application for a simple, rapid and economical determination of Hg2+ in water samples.  相似文献   

6.
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand [2‐mercapto‐5‐(3‐nitrophenyl)‐1,3,4‐thiadiazole] (MNT), self‐assembled to gold nanoparticles (GNP) as suitable carrier for Cd(II) ion with potentiometric method are described. The proposed electrode exhibits a Nernstian slope of 29.4±1.0 mV per decade for Cd(II) ion over a wide concentration range from 3.1×10?8 to 3.1×10?4 mol L?1. The detection limit of electrode was 2.0×10?8 mol L?1 of cadmium ion. The potentiometric responses of electrode based on MNT is independent of the pH of test solution in the pH range 2.0–4.0. It has quick response with response time of about 6 s. The proposed electrode show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrode was successfully employed to detect Cd(II) ion in hair and water samples.  相似文献   

7.
A fullerene‐C60‐modified glassy carbon electrode has been examined for the simultaneous determination of 2′‐deoxyadenosine (2′‐dAdo) and adenine in human blood and urine using Osteryoung square‐wave voltammetry (OSWV) at pH 7.2. Compared to bare glassy carbon electrode (GCE), the modified electrode displays a shift of the oxidation potential in the negative direction with significant increase in the peak current for both the analytes. At modified electrode well‐defined anodic peaks at potential of 1248 mV and 994 mV are observed for 2′‐dAdo and adenine respectively. Linear calibration curves were obtained within the concentration range 10 nM to 100 μM for both the compounds in 0.1 M phosphate buffer solution (PBS) with the limit of detection 0.8×10?8 M and 0.95×10?8 M for 2′‐dAdo and adenine respectively. The analytical utility of the present method is demonstrated by quantitative detection of 2′‐dAdo and adenine in human urine of normal subjects as well as in patients with hepatocellular carcinoma. Interfering effect of some coexisting metabolites has also been reported.  相似文献   

8.
A glassy carbon electrode modified with per‐6‐amino‐β‐cyclodextrin (β‐CDNH2) and functionalized single‐walled carbon nanotubes (SWCNT‐COOH) was elaborated. This structure was investigated for the detection of dopamine acid (DA) in presence of ascorbic acid (AA). The sensor behavior was studied by cyclic voltammetry, square wave voltammetry and electrochemical impedance spectroscopy. The analysis results show that the electrode modification with CD derivative improves the sensitivity and selectivity of the DA recognition; the electrochemical response was further improved by introduction of SWCNT‐COOH. The sensor shows good and reversible linear response toward DA within the concentration range of 7×10?7–10?4 M with a detection limit of 5×10?7 M.  相似文献   

9.
2‐chlorobenzoyl ferrocene, was synthesized and used to construct a modified ZnO‐CuO nanoplates modified carbon paste electrode. The electrooxidation of captopril at the surface of the modified electrode was studied. Under the optimized conditions, the square wave voltammetric (SWV) peak current of captopril increased linearly with captopril concentration in the range of 5.0×10?7 to 9.0×10?4 M and detection limit of 90.0 nM was obtained for captopril. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for captopril oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of captopril and tryptophan which makes it suitable for the detection of captopril in the presence of tryptophan in real samples.  相似文献   

10.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

11.
A glassy carbon electrode (GCE) modified with Mg‐Al‐SDS hydrotalcite‐like clay (SDS‐HTLC) was used for the sensitive voltammetric determination of 2‐nitrophenol (2‐NP) utilizing the oxidation process. The results indicate the prepared modified electrode has an excellent electrocatalytic activity toward 2‐NP oxidation, lowering the oxidation overpotential and increasing the oxidation current. Under optimal conditions, the oxidation current was proportional to 2‐NP concentration in the range from 1.0×10?6 to 6.0×10?4 M with the detection limit of 5.0×10?7 M by DPV (S/N=3). The fabricated electrode was applied for 2‐NP determination in water samples and the recovery for these samples was from 95.6 to 103.5%.  相似文献   

12.
A composite multiwalled carbon nanotube polyvinyl chloride electrode based on 7,16‐dibenzyl‐1,4,10,13‐tetraoxa‐7,16‐diazacyclooctadecane (DBDA18C6) as Sm3+ ionophore is reported. This potentiometric sensor showed a wide linear working range, 1×10?2–1×10?8 M, Nernstian slope, 20.2±0.48 mV per decade and a limit of detection, 6.3±0.36×10?9 M. It works in the pH range 2.5–8.5 and shows a good selectivity over a number of metal ions. It has been found suitable for the analysis of ores and industrial effluents. The electrode surface is characterized by FRA and AFM.  相似文献   

13.
A carbon paste electrode spiked with 1‐[4‐ferrocenyl ethynyl) phenyl]‐1‐ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder‐paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less positive than at an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and rate constant for the chemical reaction between Trp and redox sites in 4FEPE modified carbon paste electrode (4FEPEMCPE) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of Trp showed a linear dependent on the Trp concentrations and linear calibration curves were obtained in the ranges of 6.00×10?6 M–3.35×10?3 M and 8.50×10?7 M–6.34×10?5 M of Trp concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 1.80×10?6 M and 5.60×10?7 M by CV and DPV methods. This method was also examined as a selective, simple and precise new method for voltammetric determination of tryptophan in real sample.  相似文献   

14.
An electrochemical method for the determination of tripelennamine hydrochloride (TPA) using cetyltrimethylammoniumbromide‐multiwalled carbon nanotubes modified glassy carbon electrode (MWCNT‐CTAB/GCE) was developed. Because of good electrical conductivity of MWCNT and catalytic behavior of CTAB, new electrode significantly enhances the sensitivity for the detection of TPA. Parameters such as amount of modifier suspension, scan rate, pH of measure solution, heterogeneous rate constant were investigated. The electrode exhibits a linear potential response in the range of 1.0×10?8 M to 3.0×10?6 M with a detection limit of 2.38× 10?9 M. The modified electrode was successfully applied to the determination of TPA in pharmaceutical and real samples.  相似文献   

15.
A carbon paste electrode was modified with 2‐(4‐Oxo‐3‐phenyl‐3,4‐dihydroquinazolinyl)‐N′‐phenyl‐hydrazinecarbothioamide, magnetic core? shell Fe3O4@SiO2/MWCNT nanocomposite and ionic liquid (n‐hexyl‐3‐methylimidazolium hexafluoro phosphate). The electro‐oxidation of hydrazine at the surface of the modified electrode was studied using electrochemical approaches. This modified electrode offers a considerable improvement in voltammetric sensitivity toward hydrazine, compared to the bare electrode. Square wave voltammetry (SWV) exhibits a linear dynamic range from 7.0×10?8 to 5.0×10?4 M and a detection limit of 40.0 nM for hydrazine. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for hydrazine oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of hydrazine and phenol that makes it suitable for the detection of hydrazine in the presence of phenol in real samples.  相似文献   

16.
《Electroanalysis》2006,18(15):1457-1462
This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen‐printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at ?1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at ?0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, ?1.5 V (vs. printed carbon) accumulation potential, 100 mV s?1 scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L?1 from 1.43×10?6 to 1.55×10?4 mol L?1. A limit of detection obtained was 6.50×10?7 mol L?1, and the relative standard deviation from five measurements of 3.0×10?5 mol L?1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.  相似文献   

17.
A sensitive and selective electrochemical method for the determination of dopamine using a combined electropolymerized permselective film of polytyramine and polypyrrole‐1‐propionic acid on a glassy carbon (GC) electrode was developed. The formation of a “layer‐by‐layer” film has allowed for selective detection of dopamine in the presence of 3,4‐dihydroxyphenylalanine (L‐DOPA), DOPAC, ascorbic acid, uric acid, epinephrine and norepinephrine. The modified electrodes exhibited a detection limit of 100 nM with linearity ranging from 5×10?6 to 5×10?5 M. No cleaning step was required during the course of repeated measurement.  相似文献   

18.
The voltammetric behavior of paraquat was investigated at hydroxyapatite‐modified carbon paste electrode HAP‐CPE in K2SO4. A method was developed for the detection of the trace of this herbicide, based on their redox reaction. The reduction peaks of paraquat were observed around ?0.70 V and ?1.00 V (vs. SCE) in square‐wave voltammetry. Experimental conditions were optimized by varying the accumulation time, apatite loading and measuring solution pH. Calibration plots were linear under the optimized parameters over the herbicide's concentration range 8–200×10?7 mol L?1, with a detection and quantification limits about 1.5×10?8 mol L?1 and 6.4 10?8 mol L?1, respectively.  相似文献   

19.
A sensitive and selective electrochemical method for the determination of dopamine (DA) was developed using a 4‐(2‐Pyridylazo)‐Resorcinol (PAR) polymer film modified glassy carbon electrode (GCE). The PAR polymer film modified electrode shows excellent electrocatalytic activity toward the oxidation of DA in a phosphate buffer solution (PBS) (pH 4.0). The linear range of 5.0×10?6–3.0×10?5 M and detection limit of 2.0×10?7 M were observed. Simultaneous detection of AA, DA and UA has also been demonstrated on the modified electrode. This work provides a simple and easy approach to selective detection of DA in the presence of AA and UA.  相似文献   

20.
In this study, a Tosflex (a perfluoro‐anion‐exchange membrane) modified glassy carbon electrode has been used to detect 2‐naphthalenol (2‐naphthol) in aqueous solutions in order to demonstrate the electroanalytical application of Tosflex. 2‐naphthol polymerizes upon electrochemical oxidation at a glassy carbon electrode; however, the current related to this oxidation is too small for analytical purpose at low concentration level. A Tosflex polymer modified glassy carbon electrode (TFGCE) was found of having capability to improve the detection limit because 2‐naphthol molecules deprotonated in basic solutions to form 2‐naphtholate anions that were accumulated to TFGCE by the anion‐exchange characteristic of Tosflex. The accumulated 2‐naphtholate anions were determined with the following differential pulse voltammetry. With 3 minutes accumulation at +0.05 V, the dependence of oxidation current versus concentration was linear from 8×10?7 M to 1×10?5 M with a regression coefficient of 0.999 and a detection limit of 2×10?7 M. Unlike many other anion‐exchange polymer modified electrodes, the TFGCE is stable at highly basic condition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号