首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A zero‐valent iron nanoparticles modified electrode was employed as an amperometric detector in flow conditions to determine metronidazole and 2‐methyl‐5‐nitroimidazole in pharmaceutical formulations. Flow injection analysis at ?0.6 V (vs. Ag) achieved limits of detection of 2 and 6 μM for metronidazole and 2‐methyl‐5‐nitroimidazole, respectively, but the analysis was not discriminative between the two compounds. When reverse phase high performance liquid chromatography was applied previous to the electrochemical detection both analytes could be analysed simultaneously. However, the limits of detection slightly increased (10 μM) as a consequence of the use of an organic solvent and a lower sample volume. The relative standard deviation of analytical repeatability was <4.0 % in both techniques. The methods were validated by comparing the results obtained from the analysis of commercial samples with those provided by HPLC‐DAD and no significant differences were detected. Results probed that the modified electrode was a successful tool in the FIA and HPLC analysis of nitro compounds.  相似文献   

2.
The capabilities of using boron-doped diamond (BDD) thin films as electrode materials for analysis of the 16 US Environmental Protection Agency (EPA) priority polyaromatic hydrocarbons (PAHs) after a liquid chromatographic separation were evaluated. The BDD electrode was able to detect all 16 PAHs with high sensitivity due to the low background current and wide potential window. The method provided detection limits ranging from 12-40 nM (3-10 ppb) and repeatable results over consecutive analysis. Calibration curves were linear up to at least 10 microM for all PAHs. The work shows the promising use of diamond as an amperometric detector in high performance liquid chromatography (HPLC), especially for PAHs and other hydrophobic aromatic compounds.  相似文献   

3.
A Ni(II)tetrakis(4-sulfonatophenyl) porphyrin (NiTPPS)|carbon nanotube composite electrode that shows strong catalytic and antifouling capability was developed to detect a series of phenolic endocrine compounds including bisphenol A, nonylphenol and ethynylestradiol. This electrode was fabricated by electropolymerizing NiTPPS complexes on a carbon nanotube-modified glassy carbon electrode. Optimized experimental parameters including a hydrodynamic potential of 0.7 V for flow injection analysis (FIA) and a NiTPPS surface coverage of 2.2 nmol cm−2 (standard deviation 0.2 nmol cm−2; n = 6) were obtained for detection of the endocrine disrupting compounds. The sensor responded well to all the tested compounds with limits of detection ranging from 15 nmol L−1 to 260 nmol L−1 (based on three times S/N ratio) under FIA conditions. Both carbon nanotubes and NiTPPS account for the excellent performance of the composite modified electrode.  相似文献   

4.
Highly boron-doped diamond (BDD) electrode, have been examined for simultaneous detection of purine and pyrimidine bases in mild acidic media by using HPLC with amperometric detection. Cyclic voltammetry at as-deposited (AD) and anodically oxidized (AO) BDD were used to study the electrochemistry and to optimize the condition for HPLC applications. At AO BDD electrode, due to its higher overpotential of oxygen evolution reaction, well-defined anodic peaks were observed for the oxidation of purine and pyrimidine bases in acid medium, whereas at AD BDD the oxidation peak of thymine was overlapped with the anodic current of oxygen evolution. The chromatograms of adenine, guanine, cytosine, thymine and 5-methylcytosine mixture were well resolved by using a silica-based column and a solution of 5% acetonitrile in 100 mM ammonium acetate buffer (pH 4.25) as the mobile phase. The detection was carried out at AO BDD electrode at an applied potential of 1.6 V versus Ag/AgCl. Linear calibration curves were obtained within the concentration range from 0.1 to 10 μM with the limits of detection (S/N = 3) ranging from 26.3 to 162.1 nM, resulting in an order of magnitude higher sensitivities than those at conventional electrodes. HPLC analysis with diamond amperometric detector was successfully applied for determination of 5-methylcytosine in real DNA samples with high reproducibility. No deactivation of the electrode was found during cyclic voltammetric and HPLC measurements, indicating the high stability for analysis of biological samples.  相似文献   

5.
The hydroxyl radicals electrochemically generated in situ on a boron-doped diamond (BDD) electrode have been investigated for the first time in different electrolyte media, over the whole pH range between 1 and 11. A more extensive characterisation of BDD electrochemical properties is very important to understand the reactivity of organic compounds towards electrochemical oxidation on the BDD electrode, which is related to their interaction with adsorbed hydroxyl radicals due to water oxidation on the electrode surface. An oxidation peak corresponding to the transfer of one electron and one proton was observed in pH <9 electrolytes, associated with the water discharge process and electrochemical generation of hydroxyl radicals, which can interact and enhance the electro-oxidation of organic compounds. In pH >9 electrolytes the electrochemical generation of hydroxyl radicals was not observed; ammonia buffer electrolyte gave a pH-independent peak corresponding to the ammonia oxidation reaction. Additionally, for most pH values studied, a few small peaks associated with the electrochemical interaction between non-diamond carbon species on the doped diamond electrode surface and the electrolyte were also seen, which suggests that the doped diamond is relatively unreactive, but not completely inert, and the electrogenerated hydroxyl radicals play a role as mediator in the oxidation of organics.  相似文献   

6.
A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min-1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE-PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE-PVA-Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.  相似文献   

7.
Sato K  Jin JY  Takeuchi T  Miwa T  Takekoshi Y  Kanno S  Kawase S 《Talanta》2001,53(5):1037-1044
Nickel-titanium (Ni-Ti) alloy electrode was used as an electrochemical detector for the analysis of underivatized amino acids in flow systems. In strong alkaline solution, an oxide film on the Ni-Ti alloy electrode surface exhibited a high catalytic activity toward the oxidation of amino acids. Cyclic voltammetry experiments confirmed that electrogenerated Ni(III)O(OH) functioned as the key redox mediator associated with the oxidation of the amine group in amino acids. The electrochemical behavior of the Ni-Ti electrode in alkaline medium was very similar to the Ni electrode. However, the oxide film was found to be much stable on Ni-Ti than on Ni. Consequently, the Ni-Ti alloy electrode exhibited an excellent stability for constant-potential amperometric detection of amino acids in flow systems. For example, the relative standard deviation (R.S.D.) for the repetitive 100 injections of 50 muM (1.2 nmol) glycine over 10 h was less than 1%. It was postulated that the presence of Ti in the alloy stabilizes the microstructure of oxide layer on the electrode surface. The sensitivities of amino acids at the electrode were different, depending on their chemical structures. The detection limits obtained in a range from 0.9 pmol for arginine to 90.2 pmol for leucine and isoleucine. The Ni-Ti alloy electrodes have been demonstrated to be very suitable for the amperometric detection of underivatized amino acids in anion-exchange chromatography.  相似文献   

8.
Comparative analysis of radical scavenging and antioxidant activities of phenolic compounds present in everyday use spice plants was carried out by means of spectrophotometric and chromatographic methods. Six spice plant samples, namely onion (Allium cepa), parsley (Petroselinum crispum) roots and leaves, celery (Apium graveolens) roots and leaves and leaves of dill (Anethum graveolens) were analyzed. Total amount of phenolic compounds and radical scavenging activity (RSA) was the highest in celery leaves and dill extracts and was the lowest in celery roots. Comparing commonly used spectrophotometric analysis of 2,2-diphenyl-1-picrylhydrazyl (DPPH) RSA of extracts with the results obtained using reversed-phase chromatographic separation with on-line post-column radical scavenging reaction detection, good correlation was obtained (R(2)=0.848). Studies using HPLC system with electrochemical detector showed that bioactive phytochemicals can be separated and antioxidant activities of individual compounds evaluated without the need of a complex HPLC system with reaction detector. The results obtained using electrochemical detection correlate with the RSA assayed using spectrophotometric method (R(2)=0.893).  相似文献   

9.
Song MJ  Kim JH  Lee SK  Lim DS 《Analytical sciences》2011,27(10):985-989
An electrochemical biosensor was developed using boron-doped diamond (BDD) as an electrode material. To enhance the electrical performance of the electrode, the BDD electrode was decorated with Pt-nanoparticles (Pt-NPs) by electrochemical deposition. Their morphology according to the applied potentials for the synthesis of Pt-NPs was characterized by SEM. To identify the performance of the electrode modified with Pt-NPs, glucose detection was used as a sample sensing process, and the results were compared with those of a gold electrode and a bare BDD electrode. The electrochemical characteristics of the modified electrode were examined by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The BDD electrode with the Pt-NPs showed higher sensitivity and a lower detection limit than the Au electrode and BDD electrode. The proposed biosensor based on the Pt-NPs decorated BDD electrode showed high sensitivity, a low detection limit, fast direct electron transfer and good stability.  相似文献   

10.
《Electroanalysis》2018,30(8):1880-1885
This work presents a simple and low‐cost method for fast and selective determination of Verapamil (VP) in tablets and human urine samples using a boron‐doped diamond working electrode (BDD) coupled to a flow injection analysis system with multiple pulse amperometric detection (FIA‐MPA). The electrochemical behaviour of VP in 0.1 mol L−1 sulfuric acid showed three merged oxidation peaks at around +1.4 V and upon reverse scan, one reduction peak at 0.0 V (vs. Ag/AgCl). The MPA detection was performed applying a sequence of three potential pulses on BDD electrode: (1) at +1.6 V for VP oxidation, (2) at +0.2 V for reduction of the oxidized product and (3) at +0.1 V for cleaning of the working electrode surface. The FIA system was optimized with injection volume of 150 μL and flow rate of 3.5 mL min−1. The method showed a linear range from 0.8 to 40.0 μmol L−1 (R>0.99) with a low limit of detection of 0.16 μmol L−1, good repeatability (RSD<2.2 %; n=10) and sample throughput (45 h−1). Selective determination of VP in urine was performed at+0.2 V due to absence of interference from ascorbic and uric acids in this potential. The addition‐recovery tests in both samples were close to 100 % and the results were similar to an official method.  相似文献   

11.
采用硼掺杂金刚石(Boron-doped diamond,BDD)薄膜电极为工作电极,利用流动注射分析方法测定水体化学需氧量(COD),根据水样中有机物组分在工作电极表面氧化消耗的电量(Qoxidation)测定样品的COD值。考察了一些基本参数包括载液、工作电位、流速对检测信号的影响并选定了最佳检测条件。在最佳检测条件下,本法检测COD的线性范围为2.5~120 mg/L,检出限为1 mg/L。用该法测定化工厂和食品厂废水的COD值,相对标准偏差和回收率分别在2.4%~4.8%和96%~106%之间,且检测结果与国家标准方法(CODcr法)有良好的一致性。  相似文献   

12.
The electrochemical oxidation of homocysteine was studied at as-deposited and anodized (oxidized) boron-doped diamond (BDD) thin film electrodes with cyclic voltammetry, flow injection analysis and high-pressure liquid chromatography with amperometric detection. At anodized boron-doped diamond electrodes, highly reproducible, well-defined cyclic voltammograms for homocysteine oxidation were obtained in acidic media, while as-deposited diamond did not provide a detectable signal. In alkaline media, however, the oxidation response was obtained both at as-deposited and anodized diamond electrodes. The potential sweep rate dependence of homocysteine oxidation (peak currents for 1 mM homocysteine linearly proportional to v(1/2), within the range of 0.01 to 0.3 V s(-1)) indicates that the oxidation involves a diffusing species, with negligible adsorption on the BDD surface at this concentration. In the flow system, BDD exhibited a highly reproducible amperometric response, with a peak variation less than 2%. An extremely low detection limit (1 nM) was obtained at 1.6 V vs. Ag/AgCl. In addition, the determination of homocysteine in a standard mixture with aminothiols and disulfide compounds by means of isocratic reverse-phase HPLC with amperometric detection at diamond electrodes has been investigated. The results showed excellent separation, with a detection limit of 1 pmol and a linear range of three orders of magnitude.  相似文献   

13.
Carrero H  Rusling JF 《Talanta》1999,48(3):711-718
High pressure liquid chromatography (HPLC) using an electrochemical (EC) detector electrode of pyrolytic graphite coated with a film of ionomer Nafion and the water-insoluble surfactant didodecyldimethylammonium bromide (DDAB) was used to achieve separation and detection of all six bromo- and chloro-acetic acids. The Nafion-DDAB film preconcentrates the acid anions facilitating their electrochemical detection by direct reduction at -1.2 V versus SCE. Detection limits were poorer than the EPA-approved GC-ECD method, but HPLC-EC avoids the derivatization necessary for GC. The HPLC-EC method also detected tribromoacetic acid, which has not been determined simultaneously with other halogenated acids by reported chromatographic methods. The HPLC-EC method using a Nafion-DDAB-coated detector electrode gave comparable results to GC-ECD for the determination of TCA in drinking water.  相似文献   

14.
本文主要以当前水环境中存在酚类有机污染物为研究对象,探讨酚类有机污染物在掺硼金刚石(BDD)电极上的取代基效应,具体研究具有不同位置及种类官能团的取代酚类有机污染物在BDD电极上的电催化氧化过程,通过化学需氧量和浓度变化考察有机污染物在电催化降解过程中的降解趋势,深入分析电极种类、官能团位置与种类与电催化氧化活性之间的联系的同时,研究阳极材料电催化氧化有机污染物的机理及动力学。结果表明,有机物在电极表面的电催化过程以电产生羟基自由基为媒介,对苯二酚在不同电极上的电催化活性与电极析氧电位及表面产生羟基自由基量有着重要的联系,BDD电极拥有最强的电催化氧化活性;不同取代基团的对位取代酚在BDD电极上的电化学降解实验显示电催化反应速率受取代官能团自身的电子效应制约,有机物矿化过程中羟基自由基首先进攻苯环的对位发生取代反应,同时取代基脱离苯环过程成为整个取代酚类电化学降解过程的决速步骤,且有机物的电催化反应速率与取代基特征Hammett常数σ呈近似线性关系。  相似文献   

15.
A non-enzymatic direct electrochemical glycerol detection method at a commercial boron-doped diamond (BDD) electrode in 0.1 M NaOH supporting electrolyte was developed. All the used electrochemical techniques proved useful features for the oxidation and direct amperometric determination of glycerol at a BDD electrode in 0.1 M NaOH aqueous solution. It was found that the direct electrooxidation of glycerol on the BDD electrode requires both adsorbed glycerol and hydroxyls at the electrode surface. Also, the sp(2) carbon did not allow enhancement of the glycerol oxidation process. The electronalytical sensitivity for the determination of glycerol at the BDD electrode ranged from 0.040 to 0.226 μA mM(-1) as a function of the technique used. The highest electroanalytical sensitivity for the determination of glycerol at the BDD electrode was reached in batch system amperometric quantification under stirring conditions. Performed recovery studies indicated that it is possible to determine glycerol in real samples, and the proposed batch system analysis-based methodology can be a valuable tool for practical glycerol analysis.  相似文献   

16.
Guanidino compounds were separated and determined by anion-exchange chromatography and electrochemical detection using a basic aqueous eluent and a nickel working electrode. It was found necessary to use a sample clean-up procedure prior to chromatographic analysis of uremic dialysate and serum samples. The effect of eluent hydroxide concentration on the retention of guanidino compounds was studied. Quantitative calibration showed that working curves were non-linear. Electrochemical detection for guanidino compounds with a nickel working electrode, while not selective, has high detection sensitivity. Detection limits for guanidino compounds ranged from 3 to 12 pmol.  相似文献   

17.
Ta/BDD薄膜电极电化学催化氧化硝基酚   总被引:1,自引:0,他引:1  
高成耀  常明 《物理化学学报》2008,24(11):1988-1994
研究了热丝化学气相沉积法(HFCVD)制备得到钽衬底掺硼金刚石膜电极(Ta/BDD)的物理性质和电势窗口, 并考察了其用于电化学催化氧化硝基酚过程中的性能及各种影响因素. 扫描电镜和拉曼光谱表明, Ta/BDD电极具有良好的物理性能, 通过测试Ta/BDD电势窗口发现, 该电极具有较高的析氧过电位. 在Ta/BDD电化学催化氧化硝基酚过程中, 化学需氧量(COD)和高效液相色谱测试表明, 硝基酚能够有效降解, 电流密度、支持电解液及浓度对降解过程影响较大, 温度影响不明显. 强化寿命实验表明, Ta/BDD电极具有较好的稳定性. 实验结果表明, Ta/BDD电极是一种适于硝基酚降解和COD去除的优良电极.  相似文献   

18.
Methodology is described for the simultaneous determination of D-penicillamine, penicillamine disulfide and the penicillamine-glutathione mixed disulfide, as well as glutathione and glutathione disulfide, in human plasma, erythrocytes and urine. The various thiols and disulfides are separated by reversed-phase ion-pairing liquid chromatography with detection by an electrochemical detector with dual gold/mercury amalgam electrodes in series. The thiols are detected at the downstream electrode; the disulfides are reduced at the upstream electrode and then detected as the thiols at the downstream electrode. Detection limits (at a signal-to-noise ratio of 2.0) are in the picomole range for 20 microliters of injected solution for all compounds except penicillamine disulfide, which has a detection limit of 600 pmol in 20 microliters. A convenient method is described for preparation of the penicillamine-glutathione mixed disulfide by thiol/disulfide exchange with standardization of the solution by 1H NMR spectroscopy.  相似文献   

19.
A boron‐doped diamond (BDD) electrode coupled to flow injection analysis (FIA) was firstly developed for determination of N‐acetyl‐L ‐cysteine (NAC) in drug formulations. The effects of experimental parameters including pH, applied potential and scan rate on the response were investigated. FIA amperometry was applied as an automatic method for the quantitative detection of trace amounts of NAC. A wide linear range of 0.5–50 µmol/L and a low detection limit of 10 nmol/L were obtained. The results of amperometric determinations show a very good reproducibility, and the RSD for the measurement based on 10 measurements was <3.7 % and <4.1 % for intra‐ and inter‐day, respectively. The benefits of the proposed method are fast, simple, sensitive and no requirement of complicated operational steps.  相似文献   

20.
Shin D  Tryk DA  Fujishima A  Muck A  Chen G  Wang J 《Electrophoresis》2004,25(17):3017-3023
The attractive features of a boron-doped diamond (BDD) thin-film detector for microchip capillary electrophoretic (CE) separations of dye-related amino-substituted aromatic compounds are described. The diamond electrode was employed in the end-column amperometric detection of 4-aminophenol (4-AP), 1,2-phenylenediamine (1,2-PDA), 2-aminonaphthalene (2-AN), 2-chloroaniline (2-CA), and o-aminobenzoic acid (o-ABA), and its attractive behavior was compared to commonly used screen-printed carbon and glassy-carbon electrodes. These conventional electrode materials exhibit a significant degree of passivation and low sensitivity to the above-mentioned environmental pollutants. The diamond-based electrochemical detection system displayed a favorable analytical performance, including lower noise levels, higher peak resolution with enhanced sensitivity, and improved resistance against electrode passivation. Factors influencing the on-chip analysis were assessed and optimized. The diamond detector displayed detection limits of 2.0 and 1.3 microM for 4-AP and 2-AN, respectively, and a wide linear response for these compounds over the 2-50 microM range. The enhanced stability was demonstrated by relative standard deviation (RSD) values of 1.4% and 4.7% for 100 microM 1,2-PDA and 200 microM 2-CA, respectively, for repetitive detections (n = 7). Besides, the simultaneously observed current decrease was 2.4 and 9.1% for 1,2-PDA and 2-CA, respectively (compared to 21.8 and 41.0% at the screen-printed carbon electrode and 28.3 and 34.1% at the glassy carbon electrode, respectively). The favorable properties of the diamond electrode indicate great promise for environmental applications in CE and other microchip devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号