首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liquid atomization is useful in many applications, such as engineering, science, pharmaceutics, medicine, forensics and others. In the present research, an innovative methodology and a new device for atomization of liquids into mists of micron and submicron droplets have been developed. The new liquid-atomization method exploits the physical phenomenon of fragmentation of thin liquid films into fine micron and submicron droplets by gas jets. For several tested prototypes, the direct observations using a high-speed visualization technique have demonstrated that bubbles were generated within a liquid and their shells have been subsequently destroyed by applying a mechanical impulse (pressure of a compressed air) once the bubbles came over the liquid surface. The main characteristics of the generated tap water mists have been experimentally measured by means of the laser diffraction technique under various conditions for each prototype. One of the prototype devices allowed obtaining mists containing 90–99% of droplets smaller than 1 µm, with the minimum arithmetic and Sauter mean droplet diameters of 1.48 µm and 2.66 µm, and the 2.64 ml/min of droplet flow rate for 3.5 bar manometer pressure of atomizing air. The gas to liquid mass ratios (GLR) in the new device are depending on the atomizing tube length and the number of perforated orifices in the tube: more the tube length, hence more the number of perforated orifices, and therefore more liquid droplets will form for the same gas flow rate. The measured GLR values related to 1 m length of the utilized atomizing tube were in the range of 0.65–1.06, and for the specifically utilized atomizing tube of 72 mm length were among 9.07–14.67. The results of this study demonstrate that the developed method of generation of very fine droplet mists has many advantages over the existing techniques and can be perspective for many practical applications.  相似文献   

2.
The paper presents the results of experimental studies on atomization of the emulsions flowing through twin-fluid atomizers obtained by the use of the digital microphotography method. The main elements of the test installation were: nozzle, reservoir, pump and measurement units of liquid flow. The photographs were taken by a digital camera with automatic flash at exposure time of 1/8000 s and subsequently analyzed using Image Pro-Plus. The oils used were mineral oils 20–90, 20–70, 20–50 and 20–30. The studies were performed at flow rates of liquid phase changed from 0.0014 to 0.011 (dm3/s) and gas phase changed from 0.28 to 1.4 (dm3/s), respectively. The analysis of photos shows that the droplets being formed during the liquid atomization have very different sizes. The smallest droplets have diameters of the order of 10 μm. The experimental results showed that the changes in physical properties of a liquid phase lead to the significant changes in the spray characteristics. The analysis of the photos of water and emulsions atomization process showed that the droplet sizes are dependent on gas and liquid flow rates, construction of nozzle and properties of liquid. The differences between characteristics of atomization for water and emulsions have been observed. Analysis of photos on forming the droplets in air–water and air-emulsions systems showed that droplets are bigger in air-emulsion system (at the same value of gas to liquid mass ratio). The values of Sauter mean diameter (SMD) increased with increase of volume fraction of oil in emulsion. The droplet size increased with emulsion viscosity.  相似文献   

3.
A water-air impinging jets atomizer is investigated in this study, which consists of flow visualization using high speed photography and mean droplet size and velocity distribution measurements of the spray using Phase Doppler Anemometry (PDA). Topological structures and break up details of the generated spray in the far and near fields are presented with and without air jet and for an impinging angle of 90°. Spray angle increases with the water jet velocity, air flow rate and impinging angle. PDA results indicate that droplet size is smallest in the spray center, with minimum value of Sauter mean diameter (SMD) of 50 µm at the air flow rate of Qm = 13.50 g/min. SMD of droplets increases towards the spray outer region gradually to about 120 µm. The mean droplet velocity component W along the air-jet axis is highest in the spray center and decreases gradually with increasing distance from the spray center. SMD normalized by the air nozzle diameter is found firstly to decrease with gas-to-liquid mass ratio (GLR) and air-to-liquid momentum ratio (ALMR) and then remain almost constant. Its increasing with aerodynamic Weber number indicates an exponential variation. The study sheds light on the performance of water-air impinging jets atomizers providing useful information for future CFD simulation works.  相似文献   

4.
Centrifugal spray injected at various angles in gas crossflow has been studied experimentally using PIV visualization system and image-processing techniques. Experiments were carried out inside a rectangular duct (95 mm × 95 mm in cross-section) at ambient temperature and pressure, with different gas Reynolds numbers (vary from 12,900 to 45,000) and three injection angles (60°, 90° and 120°). The spray angle of the centrifugal nozzle is 80°, with D32 of 80 μm. The instantaneous images of droplets distribution and the values of the line-averaged D32 at different positions on the cross-sections along the flow field for each condition were obtained, and their flow field configurations were achieved. Quantitative assessments of mixing degree between two phases for different injection angles were determined using a spatial unmixedness parameter. It is found that the addition of droplets into the gas crossflow enhanced the turbulence intensity of the gas crossflow and caused different-scale vortices. The flow field structure, to a great extent, is dependent on the injection angle. The entrainment and centrifugal force of large vortex lead to uneven droplet distribution and moreover influence the mixing of droplets and gas crossflow. A better mixing result can be obtained with the injection angle of nozzles of 60°.  相似文献   

5.
Coalescence of sessile droplets is studied experimentally with water–glycerin mixtures of different viscosities. Effects of viscosity on the dimensionless spreading length (Ψ) and the center-to-center distance (L) are investigated for two droplets; the first droplet (Ds) is stationary on a substrate and the second droplet (D0) landing at a center-to-center distance L from the first droplet. For a low viscosity fluid, Ψ is maximum when L approaches zero (or λ  1, where λ = 1  L/Ds), which represents a head-on collision. For a high viscosity fluid, Ψ is minimum when λ  0.6. The effect of λ on line printing for various viscosities is also examined by printing multiple droplets. We found that the larger the viscosity, the less the breakup between droplets; viscosities smaller than 60 wt% glycerin yielded line breakup. The overlap ratio of λ > 0.3 produced not a line, but a bigger droplet or puddle because of coalescence. Data obtained in this work can provide insights for the fabrication of conductive microtracks or microinterconnects in printed-electronics applications where a line breakup between droplets would lead to an electrical circuit short.  相似文献   

6.
In order to obtain the knowledge necessary for developing new effective fire extinguishing technologies, we determined experimentally the gas temperature in the trace of water droplets streamlined by hot air flow. It was important to establish how much the temperature in the droplet trace decreases and how fast it recovery to the initial temperature field after the droplet evaporation. The following parameters were varied: droplet size from 1.3 mm to 1.7 mm, velocity from 1 m/s to 5 m/s, initial airflow temperature from 473 K to 773 K, number of droplets (one or two), and the arrangement of droplets relative to the hot inflow (serial or parallel). The study proves the theoretical hypothesis about a significant influence of evaporation on the temperature in the water droplet trace. When a temperature trace of water droplets is formed, irrespective of their arrangement, the role of the evaporation process strengthens with the gas flow temperature rising. Furthermore, the study specifies typical longitudinal dimensions of the aerodynamic and temperature traces of water droplets. It has been established that when droplets are located in series and in parallel, their combined impact on the temperature and velocity of the gas flow in the medium differs rather considerably.  相似文献   

7.
In-line flow segregators based on axial induction of swirling flow have important applications in chemical, process and petroleum production industries. In the later, the segregation of gas bubbles and/or water droplets dispersed into viscous oil by swirling pipe flow may be beneficial by either providing a pre-separation mechanism (bubble and/or drop coalescer) or, in the case of water-in-oil dispersions, by causing a water-lubricated flow pattern to establish in the pipe (friction reduction). Works addressing these applications are rare in the literature. In this paper, the features and capabilities of swirling pipe flow axially induced by a vane-type swirl generator were investigated both numerically and experimentally. The numerical analysis has been carried out using a commercial CFD package for axial Reynolds numbers less than 2000. Pressure drop, tangential and axial velocity components as well as swirl intensity along a 5 cm i.d. size and 3 m long pipe were computed. Single phase flow experiments have been performed using a water–glycerin solution of 54 mPa s viscosity and 1210 kg/m3 density as working fluid. The numerical predictions of the pressure drop were compared with the experimental data and agreement could be observed within the range of experimental conditions. The experiments confirmed that swirl flow leads to much higher friction factors compared with theoretical values for non-swirl (i.e. purely axial) flow. Furthermore, the addition of a conical trailing edge reduces vortex breakdown. Visualization of the two-phase swirling flow pattern was achieved by adding different amounts of air to the water–glycerin solution upstream the swirl generator.  相似文献   

8.
An experimental study of the flow field in a two-dimensional wall jet has been conducted. All measurements were carried out using hot-wire anemometry. The experimental facility has a rectangular slot nozzle of high aspect ratio l/b = 100 (where l and b are the length and height slot, respectively). Mean velocities and Reynolds stresses were determined with three nozzle Reynolds numbers (Re = 1 × 104, 2 × 104 and 3 × 104) and four different inclination angles between the wall and the flow velocity at the nozzle (β = 0°, 10°, 20° and 30°). Results indicate that all wall jets are self-preserving in the developed region. Normal to the wall two regions can be identified: one similar to a plane free jet and the other similar to a boundary layer. Downstream the interaction between these two regions creates a mixed or third region. The logarithmic region increases with the distance from the nozzle and with the Reynolds number. For the inclined wall jet, the spreading rate expressed in terms of jet half-width or maximum velocity decay with respect to the streamwise distance, asymptotes to a linear law. The streamwise locations where the jet becomes self-similar are farther from the exit than in parallel wall jet. The slope of both half-width and maximum velocity decay in the developed region are affected by both wall jet inclination angle and nozzle exit Reynolds number.  相似文献   

9.
A diagnostic technique capable of characterizing interfaces between transparent, immiscible fluids is developed and demonstrated by investigating the morphology of liquid–gas interfaces in an adiabatic two-phase flow through a microchannel of 500 μm × 500 μm square cross section. Water seeded with 0.5 μm-diameter fluorescent polystyrene particles is pumped through the channel, and the desired adiabatic two-phase flow regime is achieved through controlled air injection. The diagnostic technique relies on obtaining particle position data through epifluorescent imaging of the flow at excitation and emission wavelengths of 532 nm and 620 nm, respectively. The particle position data are then used to resolve interface locations to within ±1 μm in the focal plane. By mapping the interface within individual focal planes at various depths within the channel, it is possible to determine the complete liquid–gas interface geometry across the channel cross section in a dynamic flow environment. Utilizing this approach, the liquid–gas phase boundaries of annular flows within a microchannel have been successfully characterized.  相似文献   

10.
The hydrodynamics and energy consumption have been studied in a cold flow, bubbling and turbulent, pressurized gas–liquid–solid three-phase fluidized bed (0.15 m ID × 1 m height) with concurrent gas–liquid up flow is proposed with the intention of increasing the gas hold up. The hydrodynamic behaviour is described and characterised by some specific gas and liquid velocities. Particles are easily fluidized and can be uniformly distributed over the whole height of the column. The effect of parameters like liquid flow rate, gas flow rate, particle loading, particle size, and solid density on gas hold up and effect of gas flow rate, solid density and particle size on solid hold up, energy consumption and minimum fluidization velocity has been studied. At the elevated pressures a superior method for better prediction of minimum fluidization velocity and terminal settling velocities has been adopted. The results have been interpreted with Bernoulli’s theorem and Richardson–Zaki equation. Based on the assumption of the gas and liquid as a pretend fluid, a simplification has been made to predict the particle terminal settling velocities. The Richardson–Zaki parameter n′ was compared with Renzo’s results. A correlation has been proposed with the experimental results for the three-phase fluidization.  相似文献   

11.
Measurements of gas holdups in bubble columns of 0.16, 0.30 and 0.33 m diameter were carried out. These columns were operated in co-current flow of gas and liquid phases and in semibatch mode. The column of 0.33 m diameter was operated at elevated pressures of up to 3.6 MPa. Nitrogen was employed as the gas phase and deionized water, aqueous solutions of ethanol and acetone and pure acetone and cumene as the liquid phase. The effects of differing liquid properties, gas density (due to elevated pressure), temperature, column diameter and superficial liquid velocity on gas holdup were studied. The gas holdup measurements were utilized by differential pressure measurements at different positions along the height of the bubble columns which allowed for the identification of axial gas holdup profiles. A decrease of gas holdup with increasing column diameter and an increase of gas holdup with increasing pressure was observed. The effect of a slightly decreasing gas holdup with increasing liquid velocity was found to exist at smaller column diameters. The use of organic solvents as the liquid phase resulted in a significant increase in gas holdup compared to deionized water. It is found that published gas holdup models are mostly unable to predict the results obtained in this study.  相似文献   

12.
The two-phase flow of a hydrophobic ionic liquid and water was studied in capillaries made of three different materials (two types of Teflon, FEP and Tefzel, and glass) with sizes between 200 μm and 270 μm. The ionic liquid was 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide, with density and viscosity of 1420 kg m−3 and 0.041 kg m−1 s−1, respectively. Flow patterns and pressure drop were measured for two inlet configurations (T- and Y-junction), for total flow rates of 0.065–214.9 cm3 h−1 and ionic liquid volume fractions from 0.05 to 0.8. The continuous phase in the glass capillary depended on the fluid that initially filled the channel. When water was introduced first, it became the continuous phase with the ionic liquid forming plugs or a mixture of plugs and drops within it. In the Teflon microchannels, the order that fluids were introduced did not affect the results and the ionic liquid was always the continuous phase. The main patterns observed were annular, plug, and drop flow. Pressure drop in the Teflon microchannels at a constant ionic liquid flow rate, was found to increase as the ionic liquid volume fraction decreased, and was always higher than the single phase ionic liquid value at the same flow rate as in the two-phase mixture. However, in the glass microchannel during plug flow with water as the continuous phase, pressure drop for a constant ionic liquid flow rate was always lower than the single phase ionic liquid value. A modified plug flow pressure drop model using a correlation for film thickness derived for the current fluids pair showed very good agreement with the experimental data.  相似文献   

13.
A thorough review of the available literature has revealed a significant lack of usable data regarding the transport of interfacial area in large diameter channels. This represents a concern for various industrial systems, but especially for predicting the performance of safety systems in nuclear reactor systems. In order to remedy this gap in the current experimental database a series of experiments has been performed. These experiments included the measurement of the local interfacial area concentration and other parameters using local electrical conductivity probes in pipes with diameters of 0.152 m [6 in.], 0.203 m [8 in.] and 0.304 m [12 in.]. Volumetric fluxes ranged up to 2 m/s [6.56 ft/s] for the liquid phase and 10 m/s [32.8 ft/s] for the gas phase, and two nominal pressure conditions of 180 kPa [26.1 psia] and 280 kPa [40.6 psia] were included. Gas was injected as large cap bubbles in order to provide a basis for evaluating models for cap-bubbly flow at low void fractions. Measurements were performed simultaneously at three axial locations to allow the evaluation of interfacial area transport. The resulting data provides valuable insight into the flow structure and behavior in all flow regimes other than annular flow and will serve as a valuable database for the evaluation of models for predicting the transport of interfacial area across a wide variety of flow conditions and pipe sizes.  相似文献   

14.
The estimation of the blockage boundary for pneumatic conveying through a slit is of significant importance. In this paper, we investigate the characteristics for blockage of powder (48 μm average diameter) through a horizontal slit (1.6 m × 0.05 m × 0.002 m). The results show that the required critical solid mass flow rate increases as the superficial air velocity increases superficial air velocity. The solid loading ratio and superficial air velocity displayed a decreasing power law relationship. This finding agrees with existing theory and experimental results. However, a minimum inlet solid loading ratio exists. When the air velocity is greater than the corresponding air velocity of the minimum solid loading ratio, the solid loading ratio exhibits an increasing trend in power law. We also found that when the inlet conveying pressure increased, the critical solid mass flow rate required for blockage, the inlet solid loading ratio, and the minimum inlet solid loading ratio increased.  相似文献   

15.
Pressure drops in the flow through micro-orifices and capillaries were measured for silicone oils, aqueous solutions of polyethylene glycol (PEG), and surfactant aqueous solutions. The diameter of micro-orifices ranged from 5 μm to 400 μm. The corresponding length/diameter ratio was from 4 to 0.05 and capillary diameters were 105 μm and 450 μm. The following results were obtained: silicone oils of 10?6 m2/s and 10?5 m2/s in kinematic viscosity generated a reduction of pressure drop (RPD), that is, drag reduction, similar to the RPD of water and a glycerol/water mixture reported in the previous paper by the present authors. When RPD occurred, the pressure drop (PD) of silicone oils of 10?6 m2/s and 10?5 m2/s had nearly the same magnitude. Namely, the difference in viscosity did not influence RPD. A 103 ppm aqueous solution of PEG20000 provided almost the same PD as that of PEG8000 for the 400 μm to 15 μm orifices, but a greater PD than that of PEG8000 for the 10 μm to 5 μm orifices. A non-ionic surfactant and a cationic surfactant were highly effective in RPD compared with anionic surfactants: the non-ionic and cationic surfactant solutions had PD one order of magnitude lower than that of water under some flow conditions in the concentration range from 1 ppm to 104 ppm, but the anionic surfactant solutions did not generate RPD except in the case of the smallest orifice of 5 μm in diameter. The PD of the non-ionic surfactant solution showed a steep rise at a Reynolds number (Ret) for 400 μm to 15 μm orifices. The Ret provides the relationship Ret = K/D, where D is the orifice diameter, and K is a constant of 2 × 10?2 m for the 100–20 μm orifices irrespective of liquid concentration. Capillary flow experiment revealed that the PEG, non-ionic and cationic surfactant solutions generated RPD also in a laminar flow through the capillary of 105 μm in diameter, but not in the flow through the capillary of 450 μm in diameter. In order to clarify the cause of RPD, an additional experiment was carried out by changing the orifice material from metal to acrylic resin. The result gave a different appearance of RPD, suggesting that RPD is related to an interfacial phenomenon between the liquid and wall. The large RPDs found in the present experiment are very interesting from both academic and practical viewpoints.  相似文献   

16.
Two-phase air–water flow characteristics are experimentally investigated in horizontal circular micro-channels. Test sections are made of fused silica. The experiments are conducted based on three different inner diameters of 0.53, 0.22 and 0.15 mm with the corresponding lengths of 320, 120 and 104 mm, respectively. The test runs are done at superficial velocities of gas and liquid ranging between 0.37–42.36 and 0.005–3.04 m/s, respectively. The flow visualisation is facilitated by systems mainly including stereozoom microscope and high-speed camera. The flow regime maps developed from the observed flow patterns are presented. The void fractions are determined based on image analysis. New correlation for two-phase frictional multiplier is also proposed for practical applications.  相似文献   

17.
A computational fluid dynamics (CFD) model is used to investigate the hydrodynamics of a gas–solid fluidized bed with two vertical jets. Sand particles with a density of 2660 kg/m3 and a diameter of 5.0 × 10?4 m are employed as the solid phase. Numerical computation is carried out in a 0.57 m × 1.00 m two-dimensional bed using a commercial CFD code, CFX 4.4, together with user-defined Fortran subroutines. The applicability of the CFD model is validated by predicting the bed pressure drop in a bubbling fluidized bed, and the jet detachment time and equivalent bubble diameter in a fluidized bed with a single jet. Subsequently, the model is used to explore the hydrodynamics of two vertical jets in a fluidized bed. The computational results reveal three flow patterns, isolated, merged and transitional jets, depending on the nozzle separation distance and jet gas velocity and influencing significantly the solid circulation pattern. The jet penetration depth is found to increase with increasing jet gas velocity, and can be predicted reasonably well by the correlations of Hong et al. (2003) for isolated jets and of Yang and Keairns (1979) for interacting jets.  相似文献   

18.
Experimental results for various water and air superficial velocities in developing adiabatic horizontal two-phase pipe flow are presented. Flow pattern maps derived from videos exhibit a new boundary line in intermittent regime. This transition from water dominant to water–gas coordinated regimes corresponds to a new transition criterion CT = 2, derived from a generalized representation with the dimensionless coordinates of Taitel and Dukler.Velocity, turbulent kinetic energy and dissipation rate, void fraction and bubble size radial profiles measured at 40 pipe diameters for JL = 4.42 m/s by hot film velocimetry and optical probes confirm this transition: the gas influence is not continuous but strongly increases beyond JG = 0.06 m/s. The maximum dissipation rate, derived from spectra, is increased in two-phase flow by a factor 5 with respect to the single phase case.The axial evolution of the bubble intercept length histograms also reveal the flow organization in horizontal layers, driven by buoyancy effects. Bubble coalescence is attested by a maximum bubble intercept evolving from 2.5 to 4.5 mm along the pipe. Turbulence generated by the bubbles is also manifest by the 4-fold increase of the maximum turbulent dissipation rate along the pipe.  相似文献   

19.
Numerous pressure drop correlations for microchannels have been proposed; most of them can be classified as either a homogeneous flow model (HFM) or a separated flow model (SFM). However, the predictions of these correlations have not been compared directly because they were developed in experiments conducted under a range of conditions, including channel shape, the number of channels, channel material and the working fluid. In this study, single rectangular microchannels with different aspect ratios and hydraulic diameters were fabricated in a photosensitive glass. Adiabatic water-liquid and Nitrogen-gas two-phase flow experiments were conducted using liquid superficial velocities of 0.06–1.0 m/s, gas superficial velocities of 0.06–72 m/s and hydraulic diameters of 141, 143, 304, 322 and 490 μm. A pressure drop in microchannels was directly measured through embedded ports. The flow pattern was visualized using a high-speed camera and a long-distance microscope. A two-phase pressure drop in the microchannel was highly related to the flow pattern. Data were used to assess seven different HFM viscosity models and ten SFM correlations, and new correlations based on flow patterns were proposed for both HFMs and SFMs.  相似文献   

20.
The understanding of the thermodynamic effects of cavitating flow is crucial for applications like turbopumps for liquid hydrogen LH2 and oxygen LOx in space launcher engines. Experimental studies of this phenomenon are rare as most of them were performed in the 1960s and 1970s. The present study presents time resolved IR (Infra-Red) measurements of thermodynamic effects of cavitating flow in a Venturi nozzle.Developed cavitating flow of hot water (95 °C) was observed at different operating conditions – both conventional high speed visualization and high speed IR thermography were used to evaluate the flow parameters.Both the mean features of the temperature distributions and the dynamics of the temperature field were investigated. As a result of evaporation and consequent latent heat flow in the vicinity of the throat a temperature depression of approximately 0.4 K was measured. In the region of pressure recuperation, where the cavitation structures collapse, the temperature rise of up to 1.4 K was recorded. It was found that the temperature dynamics closely follows the dynamics of cavitation structures.Finally experimental results were compared against a simple model based on the Rayleigh–Plesset equation and the thermal delay theory and plausible agreement was achieved.Experimental data is most valuable for further development of numerical models which are, due to poor ensemble of existing experimental results, still at a very rudimentary level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号