首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
The development of ultrathin-layer silica gel plates with a monolithic structure opens up a new dimension in thin-layer chromatography (TLC). The very small layer thickness of approximately 10 microm and the absence of any kind of binder in combination with the framework of this stationary phase lead to new and improved properties of these ultrathin-layer chromatographic (UTLC) silica-gel plates compared with conventional TLC and high-performance TLC (HPTLC) precoated layers. First of all, the advantages of the UTLC plates are the very short migration distances and, in combination with this, the short development times as well as the very low consumption of solvents as the mobile phase in connection with high sensitivity. The separations of amino acids, pesticides, pharmaceutically active ingredients, phenols, and plasticizers effectively demonstrate the possibilities of the new ultrathin-layer silica-gel plates. Furthermore, a comparison of UTLC, HPTLC, and TLC concerning retention behavior, efficiency, detection limits, migration times, and solvent consumption is performed effectively by the separation of caffeine and paracetamol.  相似文献   

2.
Ultrathin-layer chromatography (UTLC) differs from high-performance thin-layer chromatography (HPTLC) and from thin-layer chromatography (TLC) in two basis things: the layer thickness, and the migration distances of the analytes. UTLC has a monolithic or a nanostructured stationary silica gel phase bound directly to the glass plates. Layer thickness in UTLC is 10 μm, instead of 100–250 μm in HPTLC. Migration distances are in the range of 1–3 cm for UTLC, instead of 8–10 cm for HPTLC. Therefore, the major advantages of UTLC over HPTLC and TLC are the shorter development times and higher separation efficiency and sensitivity. Moreover, separations on UTLC plates require smaller reagent and sample volumes. However, the UTLC plates are very difficult to manage with the TLC and HPTLC equipment currently available. Therefore, the next challenge in this area is the development of an inexpensive solution with appropriate instrumentation (sensitive optical scanners and sample application systems). UTLC had been used for separations of many compounds, e.g., pharmaceutically active ingredients, pesticides, plasticisers, natural products, and other chemical substances.  相似文献   

3.
Ultrathin layer chromatography (UTLC) is a relatively new variant of thin layer chromatography, with a 10mum thick monolithic silica sorbent layer that gives faster separations with lower limits of detection and reduced analyte and solvent volumes. We have produced UTLC plates with controllable nanostructure and thickness, and show that the layer separation characteristics depends on the film nanostructure. We also show that layers made with in-plane anisotropic nanostructures will exhibit a decoupling effect, where the analyte spots do not develop in the same direction as the solvent front movement. The added layer morphology and material selection adds a degree of freedom to UTLC, and may have applications in multi-dimensional TLC.  相似文献   

4.
The performance of nanoporous silicon (pSi) and ultra-thin layer chromatography (UTLC) plates as surfaces for desorption electrospray ionization (DESI) was compared with that of polymethyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE), both popular surfaces in previous DESI studies. The limits of detection (LODs) and other analytical characteristics for six different test compounds were determined using all four surfaces. The LODs for the compounds were in the fmol-pmol (pg-ng) range. The LODs with the pSi surface were further improved for each of the compounds when heat was applied to the surface during sample application which gave LODs as low as or lower than those achieved with PMMA and PTFE. The UTLC plates were successfully used as a rapid means of chromatographic separation prior to DESI-MS analysis. Another advantage achieved using the newer pSi and UTLC surfaces was increased speed of analysis, associated with drying of solution-phase samples. This took place immediately at the UTLC surface and it could be achieved rapidly by gently heating the pSi surface. The presence of salts in the sample did not cause suppression of the analyte signal with any of the surfaces.  相似文献   

5.
The feasibility of ultra thin-layer chromatography atmospheric pressure matrix-assisted laser desorption ionization mass spectrometry (UTLC-AP-MALDI-MS) has been studied in the analysis of small molecules. Because of a thinner adsorbent layer, the monolithic UTLC plates provide 10-100 times better sensitivity in MALDI analysis than conventional high performance thin-layer chromatography (HPTLC) plates. The limits of detection down to a low picomole range are demonstrated by UTLC-AP-MALDI-MS. Other advantages of UTLC over HPTLC include faster separations and lower solvent consumption. The performances of AP-MALDI-MS and vacuum MALDI-MS have been compared in the analysis of small drug molecules directly from the UTLC plates. The desorption from the irregular surface of UTLC plates with an external AP-MALDI ion source combined with an ion trap instrument provides clearly less variation in measurements of m/z values when compared with a vacuum MALDI-time-of-flight (TOF) instrument. The performance of the UTLC-AP-MALDI-MS method has been applied successfully to the purity analysis of synthesis products produced by solid-phase parallel synthesis method.  相似文献   

6.
Ultrathin-layer chromatography (UTLC) provides the high sensitivities and rapid separations over short distances desirable in many analytical applications. The dependence of these performance benefits on UTLC layer microstructure motivates continued stationary phase engineering efforts. A new method of modifying the elution behaviours of nanostructured thin film UTLC stationary phases is investigated in this report. Macroporous normal phase silica thin films ~5 μm thick were fabricated using glancing angle deposition (GLAD). Reactive ion etching (RIE) and a subsequent annealing treatment modified stationary phase morphology to tune migration velocity, analyte retention, and overall separation performance. Combining this technique with a RIE shadow mask enabled fabrication of adjacent concentration and separation zones with markedly different elution properties. Although produced using an entirely new approach, GLAD UTLC concentration zone media behaved in a manner consistent with traditional thin-layer chromatography (TLC) and high-performance TLC (HPTLC) concentration zone plates. In particular, these new media focused large volume, low concentration dye mixture spots into narrow bands to achieve high-quality separations. The described approach to modifying the morphology and resultant elution behaviours of nanostructured stationary phases expands the capabilities of the GLAD UTLC technique.  相似文献   

7.
Two-dimensional thin-layer chromatographic systems on cyano-bonded polar stationary phases were used for the separation of some phenolic compounds extracted from two species of Polygonum: Polygonum hydropiper L. and Polygonum cuspidatum L. Non-aqueous solvents were used in the first direction and aqueous solvents were used in the second direction on CN silica TLC plates. For the separation of phenolics' standards optimal chromatographic systems were chosen from the retention data collected in one-dimensional TLC experiments by plotting graphs of R(F) vs. R(F) dependencies. Using above described method the satisfactory results of separations were obtained.  相似文献   

8.
Abstract

Procedures are described for the thin layer chromatographic (TLC) analysis of coal-derived liquids. After solvent selection using Selectosol (1) radial TLC, a series of compounds typically found in coal liquids was used to demonstrate their elution behavior on silica gel. It was determined that unactivated (Brockman 4) silica plates series developed with isooctane/tetrahydrofuran (THF) (80:20, v/v) provided the best separation. The order of elution was saturate >hydroaromatic >polynuclear aromatic (PNA)>phenols ≥ nitrogen bases. The use of two-dimensional TLC with reverse phase and silica contiguous on the same plate (Whatman Multi-K) is discussed for the rapid separation and identification of coal liquid components. Trimethylsilyl ether derivatives were prepared of phenols and alcohols present in coal conversion products. This technique proved most useful in that the TMS-derivatives behaved similarly to their parent PNA, in order of elution, on silica plates using a moderately active mobile phase (isooctane: THF,80:20, v/v). TLC and the reactions described provide a semi-quantitative measure of the degree of hydrogenation of coal-derived liquids.  相似文献   

9.
Ultrathin-layer chromatography (UTLC) potentially offers faster analysis, reduced solvent and sample volumes, and lower costs. One novel technique for producing UTLC plates has been glancing angle deposition (GLAD), a physical vapor deposition technique capable of aligning macropores to produce interesting separation properties. To date, however, GLAD-UTLC plates have been restricted to model dye systems, rather than realistic analytes. This study demonstrates the transfer of high-performance thin-layer chromatography (HPTLC) sugar analysis methods to GLAD-UTLC plates using the office chromatography framework. A consumer inkjet printer was used to apply very sharp low volume (3–30 nL) bands of water-soluble analytes (lactose, sucrose, and fructose). Analytic performance measurements extrapolated the limits of detection to be 3–5 ng/zone, which was experimentally proven down to 60–70 ng/band, depending on the sugar. This qualitative analysis of sugars in a commercially available chocolate sample is the first reported application of GLAD-UTLC to food samples. The potential utility of GLAD-UTLC is further exemplified by successful coupling with electrospray ionization mass spectrometry for the first time to characterize underivatized sugars.
Figure
An inkjet printer applied small volumes of sugar sample to miniaturized planar chromatography plates (a) fabricated from nanostructured silica GLAD thin films (b). The separated sugars were derivitized and imaged. A chromatogram (c) was produced for each separation track (blue box).  相似文献   

10.
Thin layer chromatography (TLC)--a simple, cost-effective, and easy-to-operate planar chromatographic technique--has been used in general chemistry laboratories for several decades to routinely separate chemical and biochemical compounds. Traditionally, chemical and optical methods are employed to visualize the analyte spots on the TLC plate. Because direct identification and structural characterization of the analytes on the TLC plate through these methods are not possible, there has been long-held interest in the development of interfaces that allow TLC to be combined with mass spectrometry (MS)--one of the most efficient analytical tools for structural elucidation. So far, many different TLC-MS techniques have been reported in the literature; some are commercially available. According to differences in their operational processes, the existing TLC-MS systems can be classified into two categories: (i) indirect mass spectrometric analyses, performed by scraping, extracting, purifying, and concentrating the analyte from the TLC plate and then directing it into the mass spectrometer's ion source for further analysis; (ii) direct mass spectrometric analyses, where the analyte on the TLC plate is characterized directly through mass spectrometry without the need for scraping, extraction, or concentration processes. Conventionally, direct TLC-MS analysis is performed under vacuum, but the development of ambient mass spectrometry has allowed analytes on TLC plates to be characterized under atmospheric pressure. Thus, TLC-MS techniques can also be classified into two other categories according to the working environment of the ion source: vacuum-based TLC-MS or ambient TLC-MS. This review article describes the state of the art of TLC-MS techniques used for indirect and direct characterization of analytes on the surfaces of TLC plates.  相似文献   

11.
Xanthones are well known for their interesting phytochemical properties, which make them attractive to the pharmaceutical and medicinal industry. We have therefore developed a method to analyse the major xanthones in Garcina mangostana. The xanthones were extracted by pressurized liquid extraction with ethanol and separated at the semi-preparative scale by centrifugal partition chromatography (CPC) with a biphasic solvent system consisting of heptane/ethyl acetate/methanol/water (2:1:2:1, v/v/v/v). A CPC-electrospray ionisation MS coupling was performed and used to simultaneously separate and identify the compounds. Thanks to a variable flow splitter and an additional stream of ethanol/1 mol L−1 ammonium acetate (95:5, v/v), all the compounds were ionised, detected and monitored whatever the solvents used in mobile phase for the CPC separation. The dual mode or elution–extrusion which are less solvent-consuming and faster than the elution mode were used without loss of ionisation and detection.  相似文献   

12.
From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C18 column using a gradient elution. Based on MSn spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2″,3″-epoxyechiumine-N-oxide.  相似文献   

13.
The development of mixed-mode stationary phase to achieve multiple separation capabilities in one column is very important for high performance liquid chromatography. In this paper, a new specific stationary phase based on grafting N-methylimidazolium to a monolithic silica column was successfully prepared for performing capillary liquid chromatography. The characteristics of the column were evaluated by the separation of different types of compounds including inorganic anions, aromatic acids, nucleotides, polycyclic aromatic hydrocarbons, alkylbenzenes, and phenols. The mechanisms for the separation of these compounds were investigated and appeared to involve the mixed interactions including anion-exchange, hydrophilic, π-π, dipole-dipole, and hydrophobic interactions.  相似文献   

14.
Chromatographic separation of 10 triterpenoids (α-amyrin, β-amyrin, δ-amyrin, lupeol, lupenon, lupeol acetate, cycloartenol, cycloartenol acetate, ursolic acid, oleanolic acid) and 2 sterols (stigmasterol and β-sitosterol) was studied. The chromatographic techniques included silica gel and reversed-phase (C18 RP) thin-layer chromatography (TLC) and C18 RP high-performance liquid chromatography (HPLC) using UV and mass spectrometric (MS) detection with atmospheric pressure chemical ionization (APCI). The TLC separation of the isomeric triterpenols lupeol, α-amyrin, β-amyrin and cycloartenol was achieved for the first time using C18 RP-HPTLC plates. Cycloartenol could be separated from related compounds only on C18 RP-TLC but not on the C18 RP-HPLC. δ-Amyrin isolated from the tomato fruit surface extract could be separated from other amyrins only by HPLC. Tandem mass spectrometry allowed discrimination between the isomers lupeol, α-amyrin, β-amyrin, δ-amyrin, cycloartenol and between lupeol acetate and cycloartenol acetate. The combination of 3 TLC methods and 2 HPLC methods enables qualitative determination of all 12 compounds and proves to be useful for the analysis of plant extracts. It is recommended that TLC screening on silica gel and C18 RP be performed before HPLC analysis.  相似文献   

15.
Thin-layer chromatography (TLC) of three cationic surfactants was performed on silica TLC plates with various solvent systems. The mutual separation of cetylpyridinium chloride (CPC), tetradecyltrimethylammonium bromide (TTAB) and dodecyltrimethylammonium bromide (DTAB) was achieved on silica TLC plates with ethanol: 1% aqueous ammonium chloride (4:6, v/v) as an eluent. Effects of cations and anions in the mobile phase on mobility and separation of CPC, TTAB and DTAB were examined. The interference due to the presence of metal cations as impurities on the resolution in the mixture of CPC, TTAB and DTAB was also examined. The limits of detection of CPC, TTAB and DTAB estimated were 0.015, 0.031 and 0.062 μg zone−1, respectively. The developed method was utilized to identify these surfactants in different spiked water samples after their preliminary separation.  相似文献   

16.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

17.
The identification of the four principal triterpenoid components of Centella asiatica has been achieved by TLC on silica gel plates and mass spectrometry, as a modification of the method described in the European Pharmacopoeia (5th edn). A combination of ethyl acetate and methanol as the mobile phase was found to be successful in separating these compounds from the rest of the main components of the extract. The spots were detected with anisaldehyde solution. The separated compounds were confirmed by MALDI -TOF mass spectrometry.  相似文献   

18.
A combinative method using high-speed counter-current chromatography (HSCCC) and thin layer chromatography (TLC) as an antioxidant autographic assay was developed to separate antioxidant components from the fruits of Psoralea corylifolia. Under the guidance of TLC bioautography, eight compounds including five flavonoids and three coumarins were successfully separated from the fruits of P. corylifolia by HSCCC with an optimized two-phase solvent system, n-hexane–ethyl acetate–methanol–water (1:1.1:1.3:1, v/v/v/v). The separation produced 5.91 mg psoralen, 6.26 mg isopsoralen, 3.19 mg psoralidin, 0.92 mg corylifol A, and 2.43 mg bavachinin with corresponding purities of 99.5, 99.8, 99.4, 96.4, and 99.0%, as well as three sub-fractions, in a single run from 250 mg ethyl acetate fraction of P. corylifolia extract. Following an additional clean-up step by preparative TLC, 0.4 mg 8-prenyldaidzein (purity 91.7%), 4.18 mg neobavaisoflavone (purity 97.4%) and 4.36 mg isobavachalcone (purity 96.8%) were separated from the three individual sub-fractions. The structures of the isolated compounds were identified by 1H NMR and 13C NMR. The results of antioxidant activity estimation by electron spin resonance (ESR) method showed that psoralidin was the most active antioxidant with an IC50 value of 44.7 μM. This is the first report on simultaneous separation of eight compounds from P. corylifolia by HSCCC.  相似文献   

19.
Microbial cultures produce complex and potentially interesting mixtures of biosynthetic intermediates and derivatives of metabolites. These mixtures' reliable identification is important and so too is the development of techniques for their analysis. Here, a simple and highly selective method of detecting the biosynthetic congeners involved in the pentangular polyphenol pradimicin (PR) pathway from Actinomadura hibisca fermentation was developed. Solid-phase extraction (SPE) cleanup using an OASIS HLB cartridge was a simple and reliable tool for the extraction of PRs from a fermentation broth. The separation of each natural PR analog--eluted with a gradient system of aqueous acetonitrile through a reversed-phase C(18) column containing ammonium acetate and acetic acid as additives--allowed their simultaneous profiling. The combined use of SPE cleanup and chromatographic separation, coupled with electrospray ionization-tandem mass spectrometry (ESI-MS/MS) detection was demonstrated to be sufficiently accurate and reliable to analyze the natural PR analogs produced from A. hibisca. Ten natural PRs were identified: four alanine-containing (PRA, PRC, PRL, and PRB), two glycine-substituted (PRD and PRE), and four serine-substituted (PRFA-1, PRFA-2, PRFL, and PRFB). This report demonstrates the first use of both SPE cleanup and HPLC-ESI-MS/MS to profile a wide range of structurally closely related PRs in a bacterial fermentation broth.  相似文献   

20.
Chromatographic properties of a new type of monolithic silica rod columns were examined. Silica rod columns employed for the study were prepared from tetramethoxysilane, modified with octadecylsilyl moieties, and encased in a stainless-steel protective column with two polymer layers between the silica and the stainless-steel tubing. A 25 cm column provided up to 45,000 theoretical plates for aromatic hydrocarbons, or a minimum plate height of about 5.5 μm, at optimum linear velocity of ca. 2.3 mm/s and back pressure of 7.5 MPa in an acetonitrile-water (80/20, v/v) mobile phase at 40°C. The permeability of the column was similar to that of a column packed with 5 μm particles, with K(F) about 2.4×10(-14) m(2) (based on the superficial linear velocity of the mobile phase), while the plate height value equivalent to that of a column packed with 2.5 μm particles. Generation of 80,000-120,000 theoretical plates was feasible with back pressure below 30 MPa by employing two or three 25 cm columns connected in series. The use of the long columns enabled facile generation of large numbers of theoretical plates in comparison with conventional monolithic silica columns or particulate columns. Kinetic plot analysis indicates that the monolithic columns operated at 30 MPa can provide faster separations than a column packed with totally porous 3-μm particles operated at 40 MPa in a range where the number of theoretical plates (N) is greater than 50,000.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号