首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present investigation is the first part of an initiative to prepare a regional map of the natural abundance of selenium in various areas of Brazil, based on the analysis of bean and soil samples. Continuous-flow hydride generation electrothermal atomic absorption spectrometry (HG-ET AAS) with in situ trapping on an iridium-coated graphite tube has been chosen because of the high sensitivity and relative simplicity. The microwave-assisted acid digestion for bean and soil samples was tested for complete recovery of inorganic and organic selenium compounds (selenomethionine). The reduction of Se(VI) to Se(IV) was optimized in order to guarantee that there is no back-oxidation, which is of importance when digested samples are not analyzed immediately after the reduction step. The limits of detection and quantification of the method were 30 ng L−1 Se and 101 ng L−1 Se, respectively, corresponding to about 3 ng g−1 and 10 ng g−1, respectively, in the solid samples, considering a typical dilution factor of 100 for the digestion process. The results obtained for two certified food reference materials (CRM), soybean and rice, and for a soil and sediment CRM confirmed the validity of the investigated method. The selenium content found in a number of selected bean samples varied between 5.5 ± 0.4 ng g−1 and 1726 ± 55 ng g−1, and that in soil samples varied between 113 ± 6.5 ng g−1 and 1692 ± 21 ng g−1.  相似文献   

2.
Abdorreza Mohammadi 《Talanta》2009,78(3):1107-1114
A simple and rapid headspace solid-phase microextraction (HS-SPME) based method is presented for the simultaneous determination of atrazine and ametryn in soil and water samples by ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS), synthesized by electrochemical method, was applied as a laboratory-made fiber for SPME. The HS-SPME system was designed with a cooling device on the upper part of the sample vial and a circulating water bath for adjusting the sample temperature. The extraction properties of the fiber to spiked soil and water samples with atrazine and ametryn were examined, using a HS-SPME device and thermal desorption in injection port of IMS. Parameters affecting the extraction efficiency such as the volume of water added to the soil, pH effect, extraction time, extraction temperature, salt effect, desorption time, and desorption temperature were investigated. The HS-SPME-IMS method with PPy-DS fiber, provided good repeatability (RSDs < 10 %), simplicity, good sensitivity and short analysis times for spiked soil (200 ng g−1) and water samples (100 and 200 ng mL−1). The calibration graphs were linear in the range of 200-4000 ng g−1 and 50-2800 ng mL−1 for soil and water respectively (R2 > 0.99). Detection limits for atrazine and ametryn were 37 ng g−1 (soil) and 23 ng g−1 (soil) and 15 ng mL−1 (water) and 10 ng mL−1 (water), respectively. To evaluate the accuracy of the proposed method, atrazine and ametryn in the three kinds of soils and two well water samples were determined. Finally, comparing the HS-SPME results for extraction and determination of selected triazines using PPy-DS fiber with the other methods in literature shows that the proposed method has comparable detection limits and RSDs and good linear ranges.  相似文献   

3.
Dithizone (diphenylthiocarbazone) was used as a complexing agent in cloud point extraction for the first time and applied for selective preconcentration of trace amounts of silver. The analyte in the initial aqueous solution was acidified with sulfuric acid (pH<1) and Triton X-114 was added as a surfactant. After phase separation, based on the cloud point separation of the mixture, the surfactant rich phase was diluted with tetrahydrofuran (THF) and the analyte determined in the enriched solution by flame atomic absorption spectrometry. After optimization of the complexation and extraction conditions, a preconcentration factor of 43 was obtained for only 10 ml of sample. The analytical curve was linear in the range of 3-200 ng ml−1 and the limit of detection was 0.56 ng ml−1. The proposed method was applied to the determination of silver in water samples.  相似文献   

4.
N. Campillo 《Talanta》2008,77(2):793-799
A gas chromatography method with atomic emission detection (GC-AED) for the determination of dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and inorganic arsenic was optimized. The analytes were derivatized in the sample solutions with methyl thioglycolate (TGM) and the products were extracted into cyclohexane before an aliquot of this organic phase was directly injected into the chromatograph. The procedure was applied to the analysis of seawaters, wines, beers and infant foods, the last requiring an additional enzymatic reaction prior to analyte derivatization. Detection limits in seawaters and beverages were 0.05, 0.15 and 0.8 ng mL−1 for DMA, MMA and inorganic arsenic, respectively. In infant foods the detection limits were 1, 10 and 25 ng g−1 for DMA, MMA and inorganic arsenic, respectively. Inorganic arsenic was detected in some of the seawater samples and three of the wines analyzed at concentration levels in the range 1-40 ng mL−1, and DMA in several of the infant foods in the range 20-80 ng g−1. The method was validated by analyzing a certified reference material and by recovery studies. All the samples were also analyzed by hydride generation and atomic fluorescence spectrometry (HG-AFS), which provided data for the total arsenic content.  相似文献   

5.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

6.
A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%.  相似文献   

7.
Non-chromatographic speciation of toxic arsenic in fish   总被引:1,自引:0,他引:1  
A rapid, sensitive and economic method has been developed for the direct determination of toxic species of arsenic present in fish and mussel samples. As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations without the need of a chromatographic previous separation. The method is based on the extraction of arsenic species from fish through sonication with HNO3 3 mol l−1 and 0.1% (m/v) Triton and washing of the solid phase with 0.1% (m/v) EDTA, followed by direct measurement of the corresponding hydrides in four different experimental conditions. The limit of detection of the method was 0.62 ng g−1 for As(III), 2.1 ng g−1 for As(V), 1.8 ng g−1 for MMA and 5.4 ng g−1 for DMA, in all cases expressed in terms of sample dry weight. The mean relative standard deviation values (R.S.D.) in actual sample analysis were: 6.8% for As(III), 10.3% for As(V), 8.5% for MMA and 7.4% for DMA at concentration levels from 0.08 mg kg−1 As(III) to 1.3 mg kg−1 DMA. Recovery studies provided percentages greater than 93% for all species in spiked samples. The analysis of SRM DORM-2 and CRM 627 certified materials evidenced that the method is suitable for the accurate determination of arsenic species in fish.  相似文献   

8.
We describe a simple and sensitive porous polypropylene membrane-protected micro-solid-phase extraction (μ-SPE) approach for the sample preparation and determination of carbamate pesticides in soil samples by high-performance liquid chromatography. The μ-SPE device consisted of C18 sorbent held within a porous polypropylene envelope. In order to achieve optimum performance, several extraction parameters were optimized. Under the most favorable conditions, the extraction efficiency of the μ-SPE was very high, with detection limits in the range of 0.01–0.40 ng g−1. This is more than two orders of magnitude lower than the limits obtained by the United States Environmental Protection Agency Methods 8321A and 8318. A linear relationship was obtained for each analyte in the range of 2 and 200 ng g−1. The relative standard deviation for the analysis of aged soil samples spiked at 5 ng g−1 was ≤11%. The reproducibility of separate μ-SPE device used for experiments was satisfactory (relative standard deviations ranged from 4 to 11%), indicating that the method is reliable for routine environmental analysis.  相似文献   

9.
10.
An analytical method for the determination of amitraz residues in beeswax after hydrolysis to 2,4-dimethylaniline is reported. It consists of wax extraction with an acid buffer solution, head space solid phase microextraction and GC-ITD analysis. The limit of determination is 1 ng g−1. Wax samples from beekepers and commercial foundations were analysed, content of residues varied from <1 to 20.5 ng g−1.  相似文献   

11.
A highly sensitive mechanized method has been developed for the determination of mercury in milk by atomic fluorescence spectrometry (AFS). Samples were sonicated for 10 min in an ultrasound water bath in the presence of 8% (v/v) aqua regia, 2% (v/v) antifoam A and 1% (m/v) hydroxilamine hydrochloride, and after that, they were treated with 8 mmol l−1 KBr and 1.6 mmol l−1 KBrO3 in an hydrochloric medium. Atomic fluorescence measurements were made by multicommutation, which provides a fast alternative in quality control analysis, due to the easy treatment of a large number of samples (approximately 70 h−1), and is an environmentally friendly procedure, which involves a waste generation of only 94.5 ml h−1 as compared with the 605 ml h−1 obtained by using continuous AFS measurements. The limit of detection found was 0.011 ng g−1 Hg in the original sample. The method provided a relative standard deviation of 3.4% for five independent analysis of a sample containing 0.30 ng g−1 Hg. To validate the accuracy of the method, a certified reference material NIST-1459 (non-fat milk powder) containing 0.3±0.2 ng g−1 Hg was analysed and a value of 0.27±0.06 ng g−1 Hg was found. A comparison made between data found by the developed procedure and those obtained by microwave-assisted digestion and continuous AFS measurements evidenced a good comparability between these two strategies. Results obtained for commercially available milk samples varied between 0.09 and 0.61 ng g−1 Hg depending on the type of sample and its origin. The confluence of the analytical waste with a 6 mol l−1 NaOH allowed us to reduce the waste generation in a working session from 1 l to 5 g solid residue with a matrix of Fe(OH)3 which contributes to the deactivation of traces of heavy metals presents in the samples that does not form volatile hydrides.  相似文献   

12.
Josep Rubert  Jordi Mañes 《Talanta》2010,82(2):567-826
A method based on Matrix Solid-Phase Dispersion (MSPD) has been developed for the determination of 5 mycotoxins (ochratoxin A and aflatoxins B and G) in different cereals. Several dispersants, eluents and ratios were tested during the optimization of the process in order to obtain the best results. Finally, samples were blended with C18 and the mycotoxins were extracted with acetonitrile. Regarding to matrix effects, the results clearly demonstrated the necessity to use a matrix-matched calibration to validate the method. Analyses were performed by liquid chromatography-triple quadrupole-tandem mass spectrometry (LC-QqQ-MS/MS). The recoveries of the extraction process ranged from 64% to 91% with relative standard deviation lower than 19% in all cases, when samples were fortified at two different concentrations levels. Limits of detection ranged from 0.3 ng g−1 for aflatoxins to 0.8 ng g−1 for OTA and the limits of quantification ranged from 1 ng g−1 for aflatoxins to 2 ng g−1 for OTA, which were below the limits of mycotoxins set by European Union in the matrices evaluated. Application of the method to the analysis of several samples purchased in local supermarkets revealed aflatoxins and OTA levels.  相似文献   

13.
Akarm Karimi 《Talanta》2009,79(2):479-68
A rapid, simple, and sensitive headspace solid phase microextraction coupled to ion mobility spectrometry (HS-SPME-IMS) method is presented for analysis of the highly specific angiotensin-converting enzyme (ACE) inhibitor, captopril (CAP). Positive ion mobility spectra of CAP were acquired with an ion mobility spectrometer equipped with a corona discharge ionization source. Mass-to-mobility correlation equation was used to identify product ions. A dodecylsulfate-doped polypyrrole (PPy-DS) coating was used as a fiber for SPME. The results showed that PPy-DS based SPME fiber was suitable for successfully extracting CAP from human blood plasma and pharmaceutical samples. The HS-SPME-IMS method provided good repeatability (R.S.D.s < 4%) for aqueous and spiked plasma samples. The calibration graphs were linear in the range of 10-300 ng mL−1 (R2 > 0.99) and detection limits were 7.5 ng mL−1 for aqueous and 6.3 ng mL−1 for plasma blank samples. Finally, a standard addition calibration method was applied to HS-SPME-IMS technique for the analysis of blood plasma samples and tablets. Purpose method seemed to be suitable for the analysis of CAP in plasma samples as it is not time consuming (state total time from sample preparation to analysis), it required only small quantities of the sample, and no derivatization was required.  相似文献   

14.
A method for the determination of 11 UV-filter compounds in sludge has been developed and evaluated. The procedure includes the use of non-porous polymeric membranes in combination with pressurised liquid extraction (PLE). Firstly, the solid sample, wetted with the extraction solvent, was enclosed into tailor-made bags prepared with low density polyethylene. Secondly, these packages were submitted to a conventional PLE (70 °C, 4 cycles of 5 min static time). Finally, the analytes were determined by liquid chromatography–atmospheric pressure photoionisation–tandem mass spectrometry. The main advantage of this procedure is the reduction of time, solvent and labour effort ought to the combination of extraction and clean-up in a single step. Although the extraction is not quantitative (thus, standard addition is recommended for quantification) selectivity is clearly gained using the membrane as a consequence of the differences of permeation and transport through the membrane between the analytes and other sample matrix components. The optimised protocol provides limits of detection ranging from 0.3 ng g−1 (ethylhexyl dimethyl p-aminobenzoate (OD-PABA)) to 25 ng g−1 (ethylhexyl triazone (EHT)) with only 0.5 g of sludge sample. All the studied UV filters were found in the samples at concentration levels between 1.4 and 2479 ng g−1, emphasising the high adsorption potential of this kind of environmental pollutants onto solid samples such as sludge. Also, this method has permitted the determination of seven of the studied UV filters in sludge samples for the first time.  相似文献   

15.
A single-step, environmentally friendly sample treatment was developed and used in combination with liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the quantitation of hexabromocyclododecane (HBCD) stereoisomers in fish. It was based on the microextraction of the stereoisomers with a supramolecular solvent (SUPRAS) made up of reverse aggregates of decanoic acid (DeA). The procedure involved the stirring of the fish sample (750 mg) with 600 μL of SUPRAS for five minutes, subsequent centrifugation for extract separation from matrix components and direct analysis of the extract after dilution 1:1 with methanol. Individual enantiomers of α-, β- and γ-HBCD were separated on a chiral stationary phase of β-cyclodextrin and quantified by monitoring of the [M−H] → Br transition at m/z 640.9→80.9. Driving forces for the microextraction of HBCD in the SUPRAS involved both dispersion and dipole–dipole interactions. Quantitation limits for the determination of individual HBCD enantiomers in hake, cod, sole, panga, whiting and sea bass were within the intervals 0.5–3.4 ng g−1, 0.9–2.5 ng g−1, 0.6–1.4 ng g−1, 1.0–5.6 ng g−1, 0.8–1.3 ng g−1 and 0.5–3.5 ng g−1, respectively. Recoveries for fish samples fortified at the ng g−1 level ranged between 87 and 114% with relative standard deviations from 1 to 10%. The sample treatment proposed greatly simplifies current procedures for extraction of HBCD stereoisomers and is a useful tool for the development of a large scale database for their presence in fish.  相似文献   

16.
In the present study, a novel analytical approach for the simultaneous determination of 27 brominated flame retardants (BFRs), namely polybrominated diphenyl ethers (PBDEs), isomers of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA) and several novel BFRs (NBFRs), together with 18 perfluoroalkyl substances (PFASs) in indoor dust was developed and validated. To achieve integrated isolation of analytes from the sample and their fractionation, a miniaturized method based on matrix solid phase dispersion (MSPD) was employed. Principally, after mixing the dust (<0.1 g) with the Florisil®, the mixture was applied on the top of a sorbent (Florisil®) placed in glass column and then analytes were eluted using solvents with different polarities. For the identification/quantification of target compounds largely differing in polarity, complementary techniques represented by gas and liquid chromatography coupled to tandem mass spectrometry (GC–MS/MS and LC–MS/MS) were used. The results of validation experiments, which were performed on the SRM 2585 material (for PBDEs, HBCDs and TBBPA), were in accordance with the certified/reference values. For other analytes (NBFRs and PFASs), the analysis of an artificially contaminated blank dust sample was realized. The method recoveries for all target compounds ranged from 81 to 122% with relative standard deviations lower than 21%. The quantification limits were in the range of 1–25 ng g−1 for BFRs and 0.25–1 ng g−1 for PFASs. Finally, 18 samples (6 households × 3 sampling sites) were analyzed. The high variability between concentrations of PFASs and BFRs in the dust samples from various households as well as collecting sites in a respective house was observed. The total amounts of PFASs and BFRs were in the range of 1.58–236 ng g−1 (median 10.6 ng g−1) and 39.2–2320 ng g−1 (median 325 ng g−1), respectively. It was clearly shown that dust from the indoor environment might be a significant source of human exposure to various organohalogen pollutants.  相似文献   

17.
The biosorption of copper(II), lead(II), iron(III) and cobalt(II) on Bacillus sphaericus-loaded Diaion SP-850 resin for preconcentration-separation of them have been investigated. The sorbed analytes on biosorbent were eluted by using 1 mol L−1 HCl and analytes were determined by flame atomic absorption spectrometry. The influences of analytical parameters including amounts of pH, B. sphaericus, sample volume etc. on the quantitative recoveries of analytes were investigated. The effects of alkaline, earth alkaline ions and some metal ions on the retentions of the analytes on the biosorbent were also examined. Separation and preconcentration of Cu, Pb, Fe and Co ions from real samples was achieved quantitatively. The detection limits by 3 sigma for analyte ions were in the range of 0.20-0.75 μg L−1 for aqueous samples and in the range of 2.5-9.4 ng g−1 for solid samples. The validation of the procedure was performed by the analysis of the certified standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 2711 Montana soil and GBW 07605 Tea). The presented method was applied to the determination of analyte ions in green tea, black tea, cultivated mushroom, boiled wheat, rice and soil samples with successfully results.  相似文献   

18.
Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 μL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g−1. The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g−1 for BDE-47, 0.09-1000 ng g−1 for BDE-100, 0.10-1000 ng g−1 for BDE-99 and 0.19-1000 ng g−1 for BDE-153 and the coefficients of estimation were ≥0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g−1) and by comparing with a reference Soxhlet technique. Recovery values were ≥80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples.  相似文献   

19.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

20.
Multi-element analysis of organic virgin olive oils from different Italian regions was carried out by inductively coupled plasma mass spectrometry (ICP-MS) aiming at developing a reliable method in the traceability of the origin of oils. The data were processed by means of the chemiometric approach of linear discriminant analysis (LDA) that allows classifying unknown samples after checking possible differentiation of samples of known origin.An external calibration curve was build for the quantitative analysis. The calibration curves for each element were linear in the range between 0.01 and 100 ng mL−1 and 0.2 to 2000 ng mL−1, the correlation coefficients were ranging between 0.996 and 0.999. Results from spike and recovery experiments at levels of 30 and 65 ng mL−1 were in the range of 91-119%, whereas the quantitation limits, based on 10 times standard deviation of the blank, were also in the range of 0.009-10.2 ng g−1, for almost all the elements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号