首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
A model mixture of light hydrocarbons was used to study the separation capacity of monolithic capillary columns based on divinylbenzene with five different carrier gases, including helium, hydrogen, nitrogen, carbon dioxide, and nitrous oxide. The results were correlated with the previously obtained data on monolithic columns based on silica gel. It was shown that the influence of the nature of the carrier gas was weaker than for silica gel columns; the polymeric columns studied behaved similarly to hollow capillary columns with polymeric stationary phases and exhibited an efficiency gain of 20–30% along the series He < H2 < N2 ~ N2O < CO2. Based on the minimum HETP (~15 μm) obtained for the investigated monolithic columns under optimum conditions with N2O or CO2 as a carrier gas, the conclusion was drawn that the creation of divinylbenzene-based monolithic capillary columns with a high specific efficiency was possible.  相似文献   

2.
The influence of the nature of the stationary phase and carrier gas (helium, hydrogen, nitrogen, carbon dioxide, or nitrous oxide) on the efficiency and separating ability of monolithic ethyleneglycol dimethacrylate (EDMA) polymer capillary columns was studied using a model mixture of light hydrocarbons C1-C4. The results were compared with the properties of silica gel and divinylbenzene (DVB) monolithic columns. For EDMA polymer monolithic columns, the effect of the carrier gas on the separating ability was markedly lower than for silica gel columns. A reduction in HETP observed in the series He > H2 > N2 > N2O > CO2 is also known for hollow capillary columns with polymer stationary phases, but the change in efficiency was ~20–30% in this case. Under the optimum conditions, HETP was minimum for the columns when CO2 or N2O was used.  相似文献   

3.
Chromatographing a model mixture of hydrocarbons with various carrier gases (helium, hydrogen, nitrogen, carbon dioxide, and nitrous oxide) was used to study the separation ability of monolithic silica capillary columns. It was revealed that the nature of the carrier gas strongly affects the retention time of the sorbates and the height equivalent to a theoretical plate (HETP) of the column, with the values of both these parameters decreasing in the series He > H2 > N2 > CO2 ~ N2O. This effect was found to be more pronounced for normal hydrocarbons than for their isomers. For chromatographing with CO2 or N2O under optimum conditions, the HETP was 25–30 μm, a value indicative of a higher specific efficiency of monolithic capillary columns. Theoretical correlations between the HETP and the properties of the mobile phase were considered. As a result, it was concluded that elevated pressures of the carrier gas, which are required to ensure the optimum operation of monolithic capillary columns, may affect the properties of the chromatographic system.  相似文献   

4.
Monolithic capillary columns based on silica gel were tested in the course of high-speed gas-chromatographic separations of a five-component mixture of C1–C4 hydrocarbons. It was found that short-length monolithic columns could be used because of their high specific efficiency; this allowed us to shorten the column dead time and the duration of analysis. The column performance of about 1000 theoretical plates per second was reached. The test sorbate mixture was completely separated on a 58.5-cm column with an efficiency of about 18 700 theoretical plates in a time shorter than 17 s. It was noted that CO2 and N2O should be predominantly used as carrier gases.  相似文献   

5.
Retention factors were measured on silica gel, ethylene glycol dimethacrylate, and divinylbenzene monolithic columns for five groups of sorbates with different polarities. The retention factors of sorbates did not correlate directly with the polarity of the stationary phase probably because of differences in inner surface areas of sorbates accessible to sorbates. For the ethylene glycol dimethacrylate and divinylbenzene monoliths, the “methylene” selectivity was approximately the same and appreciably higher than for the silica gel monolith when helium was used as a carrier gas and approximately the same for monoliths of all types when the carrier gas was CO2. Original Russian Text ? V.E. Shiryaeva, A.A. Korolev, T.P. Popova, A.A. Kurganov, 2009, published in Zhurnal Fizicheskoi Khimii, 2009, Vol. 83, No. 7, pp. 1365–1369.  相似文献   

6.
The productivity of monolithic capillary columns based on silica gel and polymers of different polarities (divinylbenzene and ethyleneglycol dimethacrylate) is investigated using a model mixture of light hydrocarbons. It is shown that the productivity of a column is noticeably affected by the type of gas carrier. The highest productivity is observed when using carbon dioxide or dinitrogen monoxide as the gas carrier. The lowest productivity is observed when uisng hydrogen or helium.  相似文献   

7.
The influence of carrier gas pressure on the retention factor k′ of light hydrocarbons C1–C4 in a monolithic capillary column based on divinylbenzene was studied. It was shown that, for monolithic columns and nonideal carrier gases, the pressure dependence of lnk′ was nonlinear over a wide pressure range and could be described by the classic Everett equation. It was concluded that the competitive adsorption model failed to describe the experimental data correctly, especially for strongly retained sorbates and/or heavy carrier gases. Original Russian Text ? A.A. Korolev, V.E. Shiryaeva, T.P. Popova, A.V. Kozin, A.A. Kurganov, 2009, published in Zhurnal Fizicheskoi Khimii, 2009, Vol. 83, No. 4, pp. 776–783.  相似文献   

8.
A new sol?Cgel protocol was designed and optimized to produce titanium-dioxide-based columns within confined geometries such as monolithic capillary columns and porous-layer open-tubular columns. A surface pre-treatment of the capillary enabled an efficient anchorage of the monolith to the silica capillary wall during the synthesis. The monolith was further synthesized from a solution containing titanium n-propoxide, hydrochloric acid, N-methylformamide, water, and poly(ethylene oxide) as pore template. The chromatographic application of capillary titania-based columns was demonstrated with the separation of a set of phosphorylated nucleotides as probe molecules using aqueous normal-phase liquid chromatography conditions. Capillary titania monoliths offered a compromise between the high permeability and the important loading capacity needed to potentially achieve miniaturized sample preparations. The specificity of the miniaturized titania monolithic support is illustrated with the specific enrichment of 5??-adenosine mono-phosphate. The monolithic column offered a ten times higher loading capacity of 5??-adenosine mono-phosphate compared with that of the capillary titania porous-layer open-tubular geometry.  相似文献   

9.
For the analysis of protein digests, the peak capacity in reversed-phase liquid chromatography is of paramount importance. A univariate method to maximize the peak capacity as developed by Wang et al. (Anal Chem 78:3406–3416, 20) has been applied and tested for a monolithic RP-18 silica capillary column. In their method, using model peptides representing a bovine serum albumin digest, the gradient time and temperature are kept constant while the flow rate and eluent strength are varied. Despite our criticism on the fixed starting conditions, a long gradient time leading to an unnecessary long analysis time and a high temperature leading to possible degradation products in the chromatogram, and the peak capacity as the only optimization parameter this fast and simple optimization strategy turns out to be applicable to capillary monolithic columns. Furthermore, the influence of the peak capacity on a second optimization parameter, the MS protein identification score, is examined. The procedure is also used to enhance the performance of two popular types of monolithic capillary LC columns (silica-C18 and poly(styrene–divinylbenzene)) of the same length for the analysis of protein digests. Comparison of both columns show that the calculated chromatographic parameters, like productivity and peak capacity, and identification score for both columns are about the same. For a more complicated nine-protein digest the performance of the silica monolith is slightly better.  相似文献   

10.
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.  相似文献   

11.
Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.  相似文献   

12.
Monolithic capillary columns were prepared by thermal initiated copolymerization of glycidyl methacrylate (GMA) and divinylbenzene (DVB) inside silanized 200 µm i.d. fused silica capillaries. Polymerization mixtures containing different amounts of porogen (1-decanol and tetrahydrofuran (THF)) and different ratios of monomer and crosslinker were used for synthesis. For characterization the pore size distribution profiles of the resulting monoliths were determined by mercury intrusion porosimetry. The morphology of the copolymer was investigated by scanning electron micrographs (SEM). A high linear dependence between flow rate and pressure drop was achieved which indicates that the polymer is pressure-stable even at high flow rates. After characterization the produced GMA-DVB monoliths, which contain reactive epoxide groups, were modified by reaction with diethylamine to obtain a poly(3-diethylamino-2-hydroxypropyl methacrylate-co-divinylbenzene) ion-exchange monolithic stationary phase. The synthesized monoliths contain ionizable amino groups that are useful for anion-exchange chromatography (AEC). Poly(3-diethylamino-2-hydroxypropyl methacrylate-co-divinylbenzene) monolithic columns allowed a fast and highly efficient separation of a homologous series of phosphorylated oligothymidylic acids [d(pT)12-18]. Since durability is an important parameter of chromatographic column characterization, the separation performance for d(pT)12-18 in a freshly produced capillary column and on the same column after 100 chromatographic runs was compared.  相似文献   

13.

For the analysis of protein digests, the peak capacity in reversed-phase liquid chromatography is of paramount importance. A univariate method to maximize the peak capacity as developed by Wang et al. (Anal Chem 78:3406–3416, 20) has been applied and tested for a monolithic RP-18 silica capillary column. In their method, using model peptides representing a bovine serum albumin digest, the gradient time and temperature are kept constant while the flow rate and eluent strength are varied. Despite our criticism on the fixed starting conditions, a long gradient time leading to an unnecessary long analysis time and a high temperature leading to possible degradation products in the chromatogram, and the peak capacity as the only optimization parameter this fast and simple optimization strategy turns out to be applicable to capillary monolithic columns. Furthermore, the influence of the peak capacity on a second optimization parameter, the MS protein identification score, is examined. The procedure is also used to enhance the performance of two popular types of monolithic capillary LC columns (silica-C18 and poly(styrene–divinylbenzene)) of the same length for the analysis of protein digests. Comparison of both columns show that the calculated chromatographic parameters, like productivity and peak capacity, and identification score for both columns are about the same. For a more complicated nine-protein digest the performance of the silica monolith is slightly better.

  相似文献   

14.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

15.
A silica monolithic capillary column was used to measure the differential enthalpy and entropy of sorption of light hydrocarbons eluted with four different carrier gases. It was demonstrated that a linear correlation between the enthalpy and entropy of sorption (compensation effect) is also typical of monolithic capillary columns, with the slope of this correlation being strongly dependent on the nature of the carrier gas. The largest slope was observed for the helium carrier gas, while for carbon dioxide it is close to zero, and, in addition, the entropy of sorption is virtually independent of the number of carbon atoms in the sorbate molecule.  相似文献   

16.
Polymethacrylate‐based monolithic capillary columns, prepared by γ‐radiation‐induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion‐pair reversed‐phase capillary liquid chromatography with high‐resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow‐split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high‐resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ‐ray‐induced monolithic column lies in the batch‐to‐batch reproducibility and long‐term high‐temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene‐divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics.  相似文献   

17.
HILIC mode columns were prepared by an on-column polymerization of acrylamide on a monolithic silica capillary column modified with N-(3-trimethoxysilylpropyl)methacrylamide as the anchor group. The products showed HILIC mode retention characteristics with three times greater permeability and slightly higher column efficiency compared to a commercially available amide-type HILIC column packed with 5-μm particles. The selectivity of the monolithic silica-based column was similar to that of the particulate column for each group of solutes towards nucleosides, nucleic bases and carbohydrate derivatives, although a considerable difference was observed in the selectivity for the solute groups. Although the retention of solutes based on the polar functionality was much smaller with the monolithic silica columns, which had a smaller phase ratio, than with the particle-packed column, the former can achieve better separation utilizing the high permeability and higher column efficiencies of a longer column.  相似文献   

18.
The chromatographic properties of monolithic capillary silica gel columns for gas chromatography were examined with the use of four different variants of the Van Deemter model. The corresponding experimental curves were measured for the elution of light hydrocarbons with the helium carrier gas in the isothermal mode at 60°C. Despite the models tested are based on different mechanisms of the smearing of chromatographic peaks, the values of the Van Deemter equation parameters proved to be very close to each other for three of the four models. All models yielded negative values of the parameter A. Physically reasonable values of the parameters of the Van Deemter equation were obtained only for the Giddings model, which takes into account the pressure drop across the column. At the same time, this model overestimated the contribution from diffusional smearing (parameter B). It was concluded that none of the models tested adequately described the chromatographic properties of monolithic capillary columns for gas chromatography.  相似文献   

19.
Monolithic capillary columns have been prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate in the presence of porogen solvent mixtures containing various concentration ratios of 1‐propanol, 1,4‐butanediol, and water with azobisisobutyronitrile as the initiator of the polymerization reaction. The through pores in organic polymer monolithic columns can be characterized by “equivalent permeability particle size”, and the mesopores with stagnant mobile phase by “equivalent dispersion particle size”. Increasing the concentration of propanol in the polymerization mixture diminishes the pore volume and size in the monolithic media and improves the column efficiency, at a cost of decreasing permeability. Organic polymer monolithic capillary columns show similar retention behaviour to packed alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have different methylene selectivities. Higher concentrations of propanol in the polymerization mixture increase the lipophilic character of the monolithic stationary phases. Best efficiencies and separation selectivities were found for monolithic columns prepared using 62–64% propanol in the porogen solvent mixture. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra‐column contributions.  相似文献   

20.
The overloaded band profiles of the protonated species of propranolol and amitriptyline were recorded under acidic conditions on four classes of stationary phases including a conventional silica/organic hybrid material in reversed‐phase liquid chromatography mode (BEH‐C18), an electrostatic repulsion reversed‐phase liquid chromatography C18 column (BEH‐C18+), a poly(styrene‐divinylbenzene) monolithic column, and a hydrophilic interaction chromatography stationary phase (underivatized BEH). The same amounts of protonated bases per unit volume of stationary phase were injected in each column (16, 47, and 141 μg/cm3). The performance of the propranolol/amitriptyline purification was assessed on the basis of the asymmetry of the recorded band profiles and on the selectivity factor achieved. The results show that the separation performed under reversed‐phase liquid chromatography like conditions (with BEH‐C18, BEH‐C18+, and polymer monolith materials) provide the largest selectivity factors due to the difference in the hydrophobic character of the two compounds. However, they also provide the most distorted overloaded band profiles due to a too small loading capacity. Remarkably, symmetric band profiles were observed with the hydrophilic interaction chromatography column. The larger loading capacity of the hydrophilic interaction chromatography column is due to the accumulation of the protonated bases into the diffuse water layer formed at the surface of the polar adsorbent. This work encourages purifying ionizable compounds on hydrophilic interaction chromatography columns rather than on reversed‐phase liquid chromatography columns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号