首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
A flow injection system has been developed consisting of on-line preconcentration of selenium species in a microcolumn filled with activated alumina, reduction of Se(VI) to Se(IV) and determination by HG-AAS. When 0.01 mol/L HNO3 is used both as carrier and activation reagent for the alumina microcolumn, up to 150 ng of Se(IV) and Se(VI) can be preconcentrated and quantitatively eluted by 500 L of 2 mol/L NH3. The preconcentration factor is 50 when 25 mL of sample is used. The detection limit is about 6 ng/L, the precision is 5% for low concentrations such as 150 ng/L and 3% at high concentrations such as 120 ng/mL. The proposed method is suitable for natural water samples and inorganic Se speciation can be performed by determining Se(IV) and total selenium [Se(VI) is evaluated from the difference].  相似文献   

2.
Ferri T  Frasconi M 《Annali di chimica》2006,96(11-12):647-656
This paper deals with determination of selenium and analysis of its speciation in some Italian mineral waters. Selenium was determined by differential pulse cathodic stripping voltammetry (DPCSV) even if square wave cathodic stripping voltammetry (SWCSV) was also taken into consideration. The selenium determined in the mineral waters here investigated is not over 600 ng L(-1); in three samples, it was found below the detection limit. Analysis of speciation revealed that Se(VI) is the highly prevailing form present: only two of the examined samples revealed a detectable amount (few ng L(-1)) of Se(IV). DPCSV made possible to detect, in two of the samples, the presence of a specie(s) able to interact with Se(IV). The apparent interaction constant for the adduct formation was evaluated and the species concentration determined. However, the nature of such compound(s) remains unknown.  相似文献   

3.
An on-line flow injection system has been developed for the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters by hydride generation atomic absorption spectrometry with microwave-aided heating prereduction of Se(VI) to Se(IV). The samples and the prereductant solutions (4 mol l−1 HCl for Se(IV) and 12 mol l−1 HCl for Se(VI)) which circulated in a closed-flow circuit were injected by means of a time-based injector. This mixture was displaced by a carrier solution of 1% v/v of hydrochloric acid through a PTFE coil located inside the focused microwave oven and mixed downstream with a borohydride solution to generate the hydride. The linear ranges were 0–120 and 0–100 μg l−1 of Se(IV) and Se(VI), respectively. The detection limits were 1.0 μg l−1 for Se(IV) and 1.5 μg l−1 for Se(VI). The precision (about 2.0–2.5% RSD) and recoveries (96–98% for Se(IV) and 94–98% for Se(VI)) were good. Total selenium values were also obtained by electrothermal atomic absorption spectrometry which agreed with the content of both selenium species. The sample throughput was about 50 measurements per hour. The main advantage of the method is that the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters is performed in a closed system with a minimum sample manipulation, exposure to the environment, minimum sample waste and operator attention.  相似文献   

4.
In this study a flow injection (FI) system used in conjunction with hydride generation (HG), atomic absorption spectrometry (AAS) and microwave (MW) aided pre-reduction of selenite (Se(IV)) to selenate (Se(IV)) with HCl:HBr has been developed in order to differentiate both inorganic selenium species. As full control of the MW reduction step is possible, the experimental approach allows the use of milder acidic conditions (10% v/v of HCl and HBr) than those conventionally accomplished with hydrochloric acid alone (≥50% v/v). Experimental parameters were optimized by the univariate optimization method. In either case, the linear range was from 1.0 to 30 μg l−1. The detection limits based on 3σ of the blank signal were 0.25 μg l−1 for Se(IV) and 0.30 μg l−1 for Se(VI). The reproducibility, about 3% RSD and recoveries of different amounts of Se(VI) and Se(IV) added to water and orange juice samples (97–103%) were good. The main advantage of the proposed method is that the sequential determination of Se(IV) and Se(VI) is performed at a high sampling frequency (ca. 50 samples per h) in a closed system without Se losses, and with a minimum sample waste, operator attention, and sample manipulation.  相似文献   

5.
Johansson K  Luo X  Olin A 《Talanta》1995,42(12):1979-1987
A spectrofluorimetric method for the determination of total selenium in biological samples has been developed. After oxidative destruction, the sample is reacted with a mixture of bromide and 2,3-diamino-1,4-dibromonaphthalene (Br2-DAN) without pH adjustment. Selenium(VI) is rapidly reduced by bromide to Se(IV) which then forms 4,7-dibromo-5,6-benzopiazselenol (Br2-DAN-Se). The conversion of Se(VI) to Br2-DAN-Se is completed in 6 min at 100°C. The piazselenol is extracted to cyclohexane and the fluorescence measured at 577 nm with excitation at 518 nm. The procedure has been validated by determinations on reference materials with selenium concentrations ranging from 4 to 1460 ng g−1. The advantages of the method are the fast reduction of Se(VI) by hydrobromic acid and the properties of Br2-DAN, which permit the piazselenol formation to be carried out in a strongly acidic medium and at high temperature. The limit of detection is 0.6 ng g−1 as estimated by three times the standard deviation of the blank determination (n = 7).

The rate of reduction of Se(VI) to Se(IV) in hydrobromic acid was investigated as a function of concentration and temperature. The new kinetic data together with previous kinetic and equilibrium data for the piazselenol formation were used to model and optimize the simultaneous reduction-derivatization procedure.  相似文献   


6.
 Parameters for the reduction of Se(VI) to Se(IV) in HCl medium by heating in a microwave oven have been optimized. The reduction resulted to be quantitative applying 100% power, corresponding to 600 W heating for 2 min in 6 mol/L or for 3 min in 4 mol/L HCl. The behavior of selenomethionine and selenocystine under the optimized reduction conditions was studied in order to evaluate a possible interference of these selenium species in the determination of Se(VI). The final determination of Se(IV), and Se(VI) were done by hydride generation-atomic absorption spectrometry. The analytical merits of the method are reported. The method was applied to the selective determination of Se(IV), and Se(VI) in spiked river and lake water. Received: 6 December 1996/Revised: 1 April 1997/Accepted: 3 April 1997  相似文献   

7.
Determination of Se(IV) and Se(VI) in high saline media was investigated by cathodic stripping voltammetry (CSV). The voltammetric method was applied to assay selenium in seawater, hydrothermal and hemodialysis fluids. The influence of ionic strength on selenium determination is discussed. The CSV method was based on the co-electrodeposition of Se(IV) with Cu(II) ions and Se(VI) determined by difference after sample UV-irradiation for photolytic selenium reduction. UV-irradiation was also used as sample pre-treatment for organic matter decomposition. Detection limit of 0.030 μg L−1 (240 s deposition time) and relative standard deviation (RSD) of 6.19% (n = 5) for 5.0 μg L−1 of Se(IV) were calculated. Linear calibration range for selenium was observed from 1.0 to 100.0 μg L−1. Concerning the pre-treatment step, best results were obtained by using 60 min UV-irradiation interval in H2O2/HCl medium. Se(VI) was reduced to the Se(IV) electroactive species with recoveries between 91.7% and 112.9%. Interferents were also investigated.  相似文献   

8.
A simple solid phase extraction procedure for speciation of selenium(IV) and selenium(VI) in environmental samples has been proposed prior to graphite furnace atomic absorption spectrometry. The method is based on the solid phase extraction of the selenium(IV)-ammonium pyrrolidine dithiocarbamate (APDC) chelate on the Diaion HP-2MG. After reduction of Se(VI) by heating the samples in the microwave oven with 4 mol l−1 HCl, the system was applied to the total selenium. Se(VI) was calculated as the difference between the total selenium content and Se(IV) content. The experimental parameters, pH, amounts of reagents, eluent type and sample volume were optimized. The recoveries of analytes were found greater than 95%. No appreciable matrix effects were observed. The adsorption capacity of sorbent was 5.20 mg g−1 Se (IV). The detection limit of Se (IV) (3sigma, n = 11) is 0.010 μg l−1. The preconcentration factor for the presented system was 100. The proposed method was applied to the speciation of selenium(IV), selenium(VI) and determination of total selenium in natural waters and microwave digested soil, garlic, onion, rice, wheat and hazelnut samples harvested various locations in Turkey with satisfactory results. In order to verify the accuracy of the method, certified reference materials (NIST SRM 2711 Montana Soil, NIST SRM 1568a Rice Flour and NIST SRM 8418 Wheat Gluten) were analyzed and the results obtained were in good agreement with the certified values. The relative errors and relative standard deviations were below 6 and 10%, respectively.  相似文献   

9.
The extraction behaviour of selenium(IV) and selenium(VI) with sodium diethyldithiocarbamate, ammonium pyrrolidinedithiocarbamate and dithizone in organic solvents has been investigated by means of flameless atomic-absorption spectrophotometry with a carbon-tube atomizer. The selective extraction of selenium(IV) and differential determination of selenium(IV) and selenium(VI) have been developed. With sodium diethyldithiocarbamate and carbon tetrachloride, when the aqueous phase/organic solvent volume ratio is 5 and the injection volume in the carbon tube is 20 microl, the sensitivity for selenium is 0.4 ng/ml for 1% absorption. The relative standard deviations are ca. 3%. Interference by many metal ions can he prevented by masking with EDTA. The proposed methods have been applied satisfactorily to determination of Se(IV) and Se(VI) in various types of water.  相似文献   

10.
The aim of the present paper is the study of the influence of a polysaccharide (carboxymethylcellulose, CMC) on uptake by a target plant Lactuca sativa (LS) of selenium and some metals. LS was grown on a well characterized soil: such as, treated with 1.5 mg kg−1 Se(IV) only and with two levels of CMC (3 and 30 mg kg−1). Similar experiments were carried out by using Se(VI) instead of Se(IV). Uptake was evaluated through the quantification of total content of Se in dried leaves and roots by a suitable technique (graphite furnace atomic absorption spectrophotometry, instrumental neutron activation analysis and differential pulse cathodic stripping voltammetry). Results evidenced as the uptake of selenium was dependent on the form of selenium added to the soil: Se(VI) is accumulated much more then Se(IV) according to its lower toxicity and higher mobility. The simultaneous presence of CMC led to a lower selenium uptake in leaves, whereas no clear influence was evidenced in roots. Furthermore, the presence of CMC influenced also the mobility process (soil→plant) of several other metals: a lower content of them was detected in plants when CMC was present in the soil.  相似文献   

11.
Muñoz Olivas R  Donard OF 《Talanta》1998,45(5):1023-1029
Speciation of inorganic selenium using hydride generation method is a widespread analytical method nowadays. However, a reduction step of Se(VI) to Se(IV) is necessary as the hydride-forming species is HSeO(3)(-) (oxydation state+IV). This paper describes the development of a batch assisted microwave system allowing a rapid (<5 min) conversion of Se(VI) to Se(IV). Hydride generation is performed by a flow injection system and detection by ICP/MS. Detection limits of 6 and 8 pg for Se(IV) and for Se(VI) (by using a sample loop of 200 mul) respectively have been achieved. This method has been validated by participating in a European certification exercise for inorganic Se speciation in aqueous solutions.  相似文献   

12.
Safavi A  Mirzaee M 《Talanta》2000,51(2):225-230
A sensitive catalytic kinetic spectrofluorimetric method for determining ng ml(-1) of selenium by flow injection analysis has been developed. The method, based on the catalytic effect of Se (IV) on the reduction of resorufin by sulphide, in the presence of cetylpyridinium chloride, is monitored spectrofluorimetrically (lambda(ex)=480 nm; lambda(em)=583 nm). The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated. The method is simple, rapid, precise, sensitive, and widely applicable. The limit of detection is 1 ng ml(-1) Se (IV), and the calibration range is 5-1000 ng ml(-1). Sampling rate is 60 samples h(-1), and the relative standard deviation of 12 determinations of 100 ng ml(-1) Se was 0.76%. The determination of Se (IV) in the presence of Se (VI) and total selenium is described. The method was applied to the determination of Se in selenium tablets, and several synthetic samples.  相似文献   

13.
In this work, a reliable method is described for speciation of soluble inorganic selenium ions, Se(IV) and Se(VI), which combines an uptake process by using living bacterial cells and electrothermal atomic absorption spectrometry (ETAAS). A selective retention of either Se(IV) or Se(IV) plus Se(VI) can be carried out by using the uptake system made up of either Pseudomonas putida or Escherichia coli strains cultivated in a culture medium based on glucose (P. putida) and glucose plus dipotassium phosphate (E. coli) mixed together with the original sample solution containing the selenium species. Discrimination between inorganic selenium species is possible by combining the optimization of the bacterial cell, the growth conditions and the relative rates of their retention from the sample. In the general procedure, an equilibrium between the analyte in the solution and the uptake system is allowed to be established, and then the concentration of selenium is determined directly in the biomass by slurry sampling ETAAS. Nonetheless, a theoretical model is proposed to describe the retention process by the living bacterial cells, which also provides a feasible quantification of the extraction process before the adsorption equilibrium is reached and whenever the agitation conditions and the sampling time are under control. The detection limits for the inorganic selenium species at the best retention conditions are of 5.7 ng Se(IV) ml(-1) for P. putida and 6.1 ng Se(IV) ml(-1) and 6.3 ng Se(VI) ml(-1) for E. coli. The relative standard deviations of the adsorption/determination process are 2.9-6.3%.  相似文献   

14.
《中国化学快报》2022,33(7):3444-3450
A simple and convenient method has been developed for the pre-concentration and separation of inorganic selenium species from environmental water samples using anion exchange chromatographic column combined with high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) measurement. 75Se(IV) and 75Se(VI) were prepared and used as tracers during the experiments. The volatility of selenium during solution evaporation was investigated to establish a reliable water samples pretreatment procedure. The parameters which affect the uptake of Se(IV) and Se(VI) on Dowex1 × 8 resin was optimized and the procedure for Se(IV) and Se(VI) separation was proposed. Both Se(IV) and Se(VI) are retained on the column in natural or alkaline solution with high distribution coefficient. The successive gradient elution of pre-concentrated species of selenium with HNO3 solution allows to differentiate between them. Se(IV) and Se(VI) finally were eluted with 0.05 mol/L HNO3 and 5.0 mol/L HNO3, respectively. The proposed method has been successfully verified using the certified reference materials (CRMs) of real water samples, and spiked recoveries for real samples were 98%-104% with 5% relative standard deviations (RSDs). The developed procedure is proved to be reliable and can be used for the rapid determination of selenium species in environmental water samples.  相似文献   

15.
A novel method for the separation and preconcentration of Se(IV)/ Se(VI) with algae and determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The Se(VI) is extracted with algae from the solution containing Se(IV)/Se(VI) at pH 5.0, and the remaining Se(IV) is then preconcentrated pH 1.0. The detection limits (3σ, n = 11) of 0.16 μg L–1 for Se(IV) and 0.14 μg L–1 for Se(VI) are obtained using 40 mL of solution. At the 2.0 μg L–1 level the relative standard deviation is 2.6% for Se(IV) and 2.3% for Se(VI). The method has been applied to the determination of Se(IV)/Se(VI) in sediment and water samples. Analytical recoveries of Se(IV) and Se(VI) added to samples are ?97 ± 5% and 102 ± 6% (95% confidence), respectively. Received: 10 February 1999 / Revised: 21 June 1999 / /Accepted: 22 June 1999  相似文献   

16.
A simple and sensitive method for the selective determination of Se(IV) and Se(VI) in natural water and sludge samples through an adsorptive process on a nanometer-sized TiO(2) (anatase) was developed. The conditions for quantitative and reproducible preconcentration, elution, and subsequent GFAAS determination were established. The proposed method gave a concentration factor of 50 for a 100 mL sample volume, characterized by high precision, high reproducibility, and direct determination of Se(IV)/Se(VI). The detection limits (3 sigma, n=11) were 4.7ng L(-1) for Se(IV) and 6.3ng L(-1) for Se(VI); the precision (relative standard deviation) was 0.7% for Se(IV) and 0.9% for Se(VI) at the 0.5microg L(-1) level.  相似文献   

17.
A simple, novel, and selective flow‐injection solid‐phase extraction with inductively coupled plasma optical emission spectrometry method was developed for the speciation of inorganic selenium in environmental water samples. A mesoporous zirconia film was simply introduced to coat coal cinder by means of the sol–gel technique, and the adsorptive performance of the coated material for Se(IV)/Se(VI) was investigated in different media. Both Se(IV) and Se(VI) can be retained quantitatively by the material in HCl/NaOH (pH 1.0–9.0) media, while only Se(IV) was adsorbed quantitatively in sodium acetate buffer (pH 3.5–6.0). Thus, the assay of Se(VI) is based on subtracting Se(IV) from total selenium by controlling different adsorptive media without employing any redox procedure. Under the optimum conditions, the detection limit of Se(IV) is 9.0 ng/L with an enrichment factor of 100, and the relative standard deviation is 3.6% (n = 9, C = 5.0 ng/mL). The developed method was successfully applied to the speciation of inorganic selenium in environmental water samples with satisfactory results. In order to further verify the accuracy of the developed method, it was applied to analysis of total selenium in GSBZ 50031–94 certified reference environmental water, and the determined values coincided with the certified values very well.  相似文献   

18.
Numerous commonly used analytical methods allow only determination of a total amount of selenium in a given sample. Electroanalytical methods as well as those based on hydride generation or on formation of piazselenol allow only determination of Se(IV). To determine Se(VI) by these procedures, present alone or in mixtures with Se(IV), it is first necessary to convert Se(VI) to Se(IV). Such conversion is effective in the presence of excess of halides in acidic media or by photoreduction. In the often used conversion of Se(VI) in the presence of chlorides or less frequently of that of bromides, it has been assumed that the halide ion acts as a reducing agent. Kinetic studies of conversion of Se(VI) in acidic solutions containing an excess of bromide ions indicated that the rate determining first step of the reaction with Se(VI) is a nucleophilic substitution of the OH2+ group in the protonated form of H2SeO4 by bromide ions. For the overall reaction with rate −d[Se(VI)]/dt = k1[H+][Br]1.15[Se(IV)] the rate constant 1 × 10−3 L2 mol−2 s−1 was found. The following formation of Se(IV) from the bromo derivative is a fast reaction probably resulting in elimination of HBrO.  相似文献   

19.
An on-line system is proposed consisting of an anion-exchange chromatographic column, microwave-induced thermooxidation of trimethylselenium in the presence of persulphate, and microwave-induced thermoreduction of Se(VI) to Se(IV) in HCl medium, followed by hydride generation and atomic absorption for the determination of trimethylselenium (TMeSe), Se(IV) and Se(VI). Trimethylselenium is eluted in the dead volume of an anion-exchange column (Hamilton PRP-X-100), before elution of Se(IV) and Se(VI). Optimum chromatographic conditions have been obtained using 100 mmol L–1 phosphate buffer (pH=6.8) H2PO 4 /HPO 4 2– as the mobile phase. Recoveries were around 100%, absolute detection limits were 1.1, 1.4 and 2.2 ng for TMeSe, Se(IV) and Se(VI), respectively. Precision was lower than 10% in all cases. The method has been applied to tap water.  相似文献   

20.
The paper presents a procedure for the multi-element inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology. Total As(III, V), Se(IV, VI) and Sb(III, V) were determined according to the following procedure: titanium dioxide (TiO2) was used to adsorb inorganic species of As, Se and Sb in sample solution; after filtration, the solid phase was prepared to be slurry for determination. For As(III), Se(IV) and Sb(III), their inorganic species were coprecipitated with Pb-PDC, dissolved in dilute nitric acid, and then determined. The concentrations of As(V), Se(VI) and Sb(V) can be calculated by the difference of the concentrations obtained by the above determinations. For the determination of As(III), Se(IV) and Sb(III), palladium was chosen as a modifier and pyrolysis temperature was 800 °C. Optimum conditions for the coprecipitation were listed for 100 ml of sample solution: pH 3.0, 15 min of stirring time, 40.0 μg l−1 Pb(NO3)2 and 150.0 μg l−1 APDC. The proposed method was applied to the determination of trace amounts of As(III, V), Se(IV, VI) and Sb(III, V) in river water and seawater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号