首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
For the determination of iodide in urine, where 80-90% of consumed iodine is excreted, a fast, simple, and sensitive method of capillary zone electrophoresis was elaborated and tested also for additional complex matrices such as human serum, cooking salt, and seawater. Several approaches were examined for the separation of iodide from other macro- and microcomponents in the tested matrices, and the best results were obtained when host-guest interaction with alpha-cyclodextrin or ion-pairing with polyethylenimine was employed. In both cases comparable resolution and sensitivity were reached. Due to the relatively high price of cyclodextrin only the method with polyethylenimine was further optimized and a simple procedure enabling the determination of iodide in untreated human urine, serum, cooking salt, and seawater was elaborated. The samples were injected for 20 s at 0.5 psi (3.45 kPa) into a fused-silica capillary (0.18 mm ID, 50 cm effective length) coated with polyacrylamide (electroosmotic flow < 2 x 10(-9) m(2)V(-1)s(-1)) and filled with the optimized background electrolyte composed of 20 mM KH(2)PO(4) and 0.7% m/v polyethylenimine. For detection, UV absorption at 200 and 230 nm was measured. Concentration limits of detection reached at 230 nm were for human urine 0.14 microM, for human serum 0.17 microM, for seawater 0.17 microM, and for cooking salt 89 nM. Relative standard deviations of iodide peak area and height in all matrices ranged within 0.93 to 4.19%.  相似文献   

2.
Determination of impurities in ionic liquids (ILs) remains a difficult task. In this work, the hyphenation of isotachophoretic (ITP) preconcentration to zone electrophoresis (ZE) has been explored for the trace analysis of the cationic impurities Na(+), Li(+), and methylimidazolium (MI(+)) in butylmethylimidazolium (BMI(+))-based ILs. Simultaneous detection of UV-transparent and UV-absorbing impurities was ensured by a BGE composed of creatinine-acetate buffer. To induce ITP, three different strategies were evaluated: (i) Sample self-stacking ensured by the addition of ammonium acetate (NH(4)Ac) to 25-50-fold diluted IL solution (transient ITP). (ii) Complete ITP-ZE separation performed in a single capillary: ITP was realized in discontinuous electrolytes comprising an 80 mM NH(4)Ac, 40 mM acetic acid, 30 mM alpha-CD, pH 5.05, leading electrolyte (LE) and a 10 mM creatinine, 10 mM acetic acid, pH 4.9, terminating electrolyte (TE). To create the ZE stage, the ITP stack of analytes was moved back toward the capillary inlet by pressure and simultaneously the capillary was filled with the BGE. This protocol made it possible to accommodate a 2.5-times diluted IL sample. (iii) Complete counterflow ITP-ZE with continuous electrokinetic sample supply: the ITP stage was performed in a capillary filled with a 150 mM NH(4)Ac, 75 mM acetic acid, 30 mM alpha-CD, pH 5.0 LE, with 40-times diluted IL at the capillary inlet. BMI(+) from IL acts as the terminating ion. The LODs reached in this latter case were at the 10 and 1 ppb levels for MI(+) and Li(+) in diluted IL matrix, respectively.  相似文献   

3.
We describe an application of capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) as the on-line concentration procedure for the determination of iodide in seawater. The effective mobility of iodide was decreased by the addition of 10 mM cetyltrimethylammonium chloride (CTAC) to an artificial seawater background electrolyte (BGE) so that transient ITP functioned and iodide was separated from other coexisting anions such as bromide, nitrite, and nitrate in seawater samples. After sample injection, 600 mM acetate was separately injected into the capillary as the terminating ion to generate transient ITP. The limit of detection (LOD) for iodide was 3.0 microg/L. The LOD was obtained at a signal-to-noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area, peak height, and migration time for iodide were 2.9, 2.1, and 0.6%. The proposed method was applied to the determination of iodide in seawater collected around the Osaka Bay. The results obtained by use of the calibration graph were agreed with those obtained by the addition of the standard solutions for iodide.  相似文献   

4.
We developed capillary zone electrophoresis with transient isotachophoresis (ITP) as an on-line concentration procedure for simultaneous determination of iodide and iodate in seawater. The effective mobility of iodide was decreased by addition of 20 mM cetyltrimethylammonium chloride to an artificial seawater background electrolyte so that transient ITP functioned for both iodide and iodate. Limits of detection for iodide and iodate were 4.0 and 5.0 microg/l (as iodine) at a signal-to-noise ratio of 3. Values of the relative standard deviation of peak area, peak height, and migration times for iodide and iodate were 2.9, 1.3, 1.0 and 2.3, 2.1, 1.0%, respectively. The proposed method was applied to simultaneous determination of iodide and iodate in seawater collected at a pond at our university.  相似文献   

5.
We focused our work on the separation of phenothiazines that are important drugs used for the treatment of psychic diseases. For a better understanding of the metabolism of these solutes, we wanted to separate not only a mixture of 12 phenothiazines but also a mixture containing phenothiazines and their N-demethyl metabolites by capillary electrophoresis. Separations in capillary zone electrophoresis were performed using 3 x 10(-2) mol/L H3PO4 (pH 2.5) but the obtained resolutions were not entirely satisfactory especially with regard to phenothiazine -N-demethyl derivative pairs. To improve the obtained results, we have performed separations by using micellar electrokinetic chromatography. In this approach, we used a running electrolyte containing 3 x 10(-2) mol/L H3PO4 electrolyte (pH 2.5) and octaethylene glycol monododecyl ether (C12E8) as neutral surfactant. By introducing 2 x 10(-3) mol/L C12E8 in the electrolyte, 11 out of 12 phenothiazines have been baseline separated. With respect to the separation of a mixture containing 3 phenothiazines and their 3 demethyl derivatives, we obtained an excellent separation by using a running electrolyte prepared with 7.5 x 10(-4) mol/L C12E8 and 3 x 10(-2) mol/L H3PO4.  相似文献   

6.
An on-line coupled capillary isotachophoresis-capillary zone electrophoresis method for the determination of glycyrrhizin in liqueurs is described. The optimised electrolyte system was 5 mM HCl+11 mM varepsilon-aminocaproic acid+0.05% hydroxyethylcellulose+30% methanol (leading electrolyte), 5 mM caproic acid+30% methanol (terminating electrolyte) and 20 mM caproic acid+10 mM histidine+0.1% hydroxyethylcellulose+30% methanol (background electrolyte). Method characteristics, i.e., linearity (20-500 ng/ml), accuracy (recovery 99+/-4%), intra-assay repeatability (2%), intermediate repeatability (3.8%) and detection limit (8 ng/ml) were determined. Speed of analysis, low laboriousness, high sensitivity and low-running cost are the typical attributes of the capillary isotachophoresis-capillary zone electrophoresis method. Developed method was successfully applied to analysis of liqueurs with liquorice extract and some foods (sweets and food supplements) containing liquorice. Found levels of glycyrrhizin in liqueurs, sweets and food supplements varied between 1-16 mg/l, 850-1050 mg/kg and 1.6-1.8 g/kg, respectively.  相似文献   

7.
A method for isotachophoretic determination of sweeteners of different character in candies and chewing gums was developed. A capillary of 0.8 mm ID and 90 mm effective length made of fluorinated ethylene-propylene copolymer is filled with an electrolyte system consisting of 10 mM HCl + 14 mM Tris, pH 7.7 (leading electrolyte) and 5 mM L-histidine + 5 mM Tris, pH 8.3 (terminating electrolyte). The analysis is performed at a driving current of 200 microA and for detection current is decreased to 100 microA. Boric acid is added to the aqueous sample solution to form borate complexes with substances of polyhydroxyl nature and make them migrate isotachophoretically. Using conductivity detection, the calibration curves in the tested concentration range up to 2.5 mM were linear for all components of interest: acesulfame K, saccharine, aspartame, cyclamate, sorbitol, mannitol, lactitol, and xylitol. The concentration detection limits ranged between 0.024 and 0.081 mM. Good precision of the ITP method is evidenced by favorable RSD values ranging from 0.8 to 2.8% obtained at the analyte concentration of 1.0 mM (n = 6). The analysis time was about 20 min. Simplicity, accuracy, and low cost of analyses make ITP an alternative procedure to methods used so far for the determination of ionizable sweeteners.  相似文献   

8.
Five flavonoids (hyperoside, isoquercitrin, quercitrin, quercetin and rutin) were separated and determined in extracts of Hypericum perforatum leaves or flowers by capillary zone electrophoresis (CZE) with isotachophoretic (ITP) sample pre-treatment using on-line column coupling configuration. The background electrolyte (BGE) used in the CZE step was different from the leading and terminating ITP electrolytes but all the electrolytes contained 20% (v/v) of methanol. The optimal leading electrolyte was 10 mM HCl of pH* approximately 7.2 (adjusted with Tris) and the terminating electrolyte was 50 mM H3BO3 of pH* approximately 8.2 (adjusted with barium hydroxide). This operational system allowed to concentrate and pre-separate selectively the flavonoid fraction from other plant constituents before the introduction of the flavonoids into the CZE capillary. The BGE for the CZE step was 50 mM Tris buffer of pH* approximately 8.75 containing 25 mM N-[tris(hydroxymethyl)methyl]-3-aminopropanesulfonic acid as co-ion and 55 mM H3BO3 as complex-forming agent. The ITP-CZE method with spectrophotometric detection at 254 nm was suitable for the quantitation of the flavonoids in real natural samples; kaempferol was used as internal standard. The limit of detection for quercetin-3-O-glycosides was 100 ng ml(-1) and calibration curves were rectilinear in the range 1-10 microg ml (-1) for most of the analytes. The RSD values ranged between 0.9 and 2.7% (n=3) when determining approximately 0.07-1.2% of the individual flavonoids in dried medicinal plants.  相似文献   

9.
An on-line coupled capillary isotachophoresis-capillary zone electrophoresis (cITP-CZE) method for the determination of the fumaric acid content in apple juice is presented. A clear separation of fumaric acid in real samples is achieved within 20 min. The leading, terminating and background electrolyte of the employed system consist of 10 mM HCl+beta-alanine+5 mM beta-cyclodextrin+0.05% hydroxypropylmethylcelullose (HPMC), pH 3, 10 mM citric acid and 20 mM citric acid+beta-alanine+5 mM beta-cyclodextrin+0.1% HPMC, pH 3.3, respectively. The linearity, recovery, repeatability and detection limit of the developed method are 25-1000 ng/ml, 1.07%, 95.4+/-3.5 (+/-s)% and 10 ng/ml, respectively. Low laboriousness (no sample pretreatment), sufficient sensitivity and low running cost are the important attributes of the cITP-CZE method which was successfully applied to analyses of real samples of apple juices.  相似文献   

10.
A two-dimensional capillary isotachophoretic method (cITP-cITP) using electrolyte system consisting of leading electrolytes (LE1): [10 mM HCl + β-alanine (pH 3.9) + 0.1% hydroxyethylcellulose (HEC)] and (LE2): [10 mM HCl + aminocaproic acid (pH 5.00) + 0.1% HEC], and 5 mM caproic acid as terminating electrolyte (TE) was studied. Two methods of detection, conductometric and UV-Vis, were applied to the determination of selected food preservatives and additives. Practical applicability was demonstrated by simultaneous determination of benzoates, sorbates, citrates and orthophosphates in 12 samples of beverages. The proposed method revealed linearity with R 2 between 0.9992 and 0.9999 for the concentration ranges: 10–100 mg/L (orthophosphate and citrate ions), 20–100 mg/L (sorbates) and 40–120 mg/L for benzoates. The detection limits for all studied ions were from 0.85 to 3.1 mg/L whereas the quantification ones were from 2.8 to 10 mg/L. The variation coefficients for five-fold analysis of all ions ranged between 0.4 and 9.1%. Obtained recoveries (from 97 to 104%) confirmed satisfactory accuracy of the proposed cITP-cITP method for the determination of tested food additives.  相似文献   

11.
A sensitive method for the simultaneous determination of chromium(III) (Cr3+) and chromium(VI) (CrO4(2-)) using in-capillary reaction, capillary electrophoresis (CE) separation and chemiluminescence (CL) detection was developed. The chemiluminescence reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr3+ ion followed by capillary electrophoresis separation. Based on in-capillary reduction, chromium(VI) can be reduced by acidic sodium hydrogensulfite to form chromium(III) while the sample is running through the capillary. Before the electrophoresis procedure, the sample (Cr3+ and CrO4(2-)), buffer and acidic sodium hydrogensulfite solution segments were injected in that order into the capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ ions migrate to the cathode, while CrO4(2-) ions, moving in the opposite direction toward the anode, react with acidic sodium hydrogensulfite which results in the formation of Cr3+ ions. Because of the migration time difference of both Cr3+ ions, Cr(III) and Cr(VI) could be separated. The running buffer was composed of 0.02 mol l(-1) acetate buffer (pH 4.7) with 1 x 10(-3) mol l(-1) EDTA. Parameters affecting CE-CL separation and detection, such as reductant (sodium hydrogensulfite) concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, were optimized. The limits of detection (LODs) of Cr(III) and Cr(VI) were 6 x 10(-13) and 8 x 10(-12) mol l(-1) (S/N=3), respectively. The mass LODs for Cr(III) and Cr(VI) were 1.2 x 10(-20) mol (12 zmol) and 3.8 x 10(-19) mol (380 zmol), respectively.  相似文献   

12.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

13.
The applicability of capillary zone electrophoresis (CZE) to ions having relatively low natural occurrences in sea water is limited by method's relatively poor concentration detection sensitivity. A combination of CZE with indirect UV detection and transient isotachophoresis (tITP) pre-concentration was developed to evolve the CZE practical utility towards the quantitative determination of the minor sea water cationic components, strontium and lithium. The ITP stacking criterion at the initial stage of a CZE separation was met by taking a highly mobile sodium, the principle matrix cation, to perform the role of a leading ion, whereas the moderately mobile sample macrocomponents, Ca2+ and Mg2+, acted as the terminating ion. The carrier electrolyte, consisting of 10 mM 4-methylbenzylamine and 1.5 mM citric acid at pH 4.8, was found to be optimal to accommodate both analyte cations in the ITP range and then separate them in the CZE mode, with relative standard deviations for migration times from 0.06-0.15% and for peak areas from 4-8%. The limits of detection were 1.3 mg l(-1) Sr2+ and 0.12 mg l(-1) Li+. The developed method was applied to the analysis of a surface sea water sample and a sea water reference material. The results were in good agreement with those obtained by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and electrothermal atomic absorption spectrometry (ET-AAS).  相似文献   

14.
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations.  相似文献   

15.
An improved transient isotachophoresis (tITP) procedure for the preconcentration of iodide from highly saline matrices was developed with the objective to quantify iodide in seawater by capillary electrophoresis (CE). The procedure takes advantage of introducing cetyltrimethylammonium chloride into the high-sodium chloride background electrolyte, which due to a specific interaction with iodide amended placement of the analyte at a large distance from the matrix chloride (the latter performed the role of a leading anion). Computer simulation showed that 2-(N-morpholino)ethanesulfonate could be adopted as a suitable terminating ion to enable isotachophoretic focusing at the beginning of the CE run. Under optimized tITP conditions, the sensitivity response of iodide was improved by a factor of 140 over normal CE mode. This allowed for direct UV detection of as low as 0.6 microg/L iodide and made feasible CE analysis of undiluted surface seawater samples where iodide was found at a 30 microg/L level. The applicability of the proposed tITP-CE method could apparently be extended to the determination of other trace seawater anions (e.g., iodate).  相似文献   

16.
An electrostatic ion chromatographic (IC) method for rapid and direct determination of iodide in seawater is reported. Separation was achieved using a reversed-phase ODS packed column (250x4.6 mm I.D.) modified by coating with Zwittergent-3-14 micelles, with an eluent comprising an aqueous solution containing 0.2 mM NaClO4 and 0.3 mM Zwittergent-3-14 and using UV detection at 210 nm. Samples prepared by dissolving NaIO3, NaNO2, NaBr, NaBrO3, NaNO3, NaI, and NaSCN in artificial or real seawaters were analyzed using this IC system. Nitrite, iodate, bromide, bromate, and nitrate showed very little or no retention, while iodide and thiocyanate were well separated, being eluted within 6 and 16 min, respectively. The detection limit for iodide obtained by injecting 400 microL of sample was 0.011 microM (S/N = 3), and the precision values obtained by analyzing samples containing 0.1 or 0.3 microM iodide in real seawater samples were 2.3% RSD and 1.2% RSD, respectively. Direct determination of iodide in real seawater samples was possible using this proposed IC system.  相似文献   

17.
The 1-ethyl-3-methylimidazolium (EMIM) cation was found to have constant mobility of 4.5 x 10(-4) cm2 V(-1) s(-1) over the pH range of 3 to 11. The electroosmotic flow of bare silica capillary was reversed by the covalently bonded room-temperature ionic liquid (RTIL) coating. With run buffer of 5 mM EMIM (pH 8.5), NH4+ in human urine was separated from the K+ matrix and was detected to be 0.37 +/- 0.012%. K+, Na+, Li+, Ca2+, Mg2+ and Ba2+ were baseline separated in RTIL-coated capillary with run buffer of 10 mM EMIMOH-acetic acid at pH 5, and the concentration of the above ions in a red wine were detected to be 907, 27.9, 0, 71.0, 83.4 and 31.1 microg/ml, respectively. The RTIL-coated capillary showed stable electroosmotic flow for at least 80 h in the run buffer.  相似文献   

18.
Chiral ITP of the weak base methadone using inverse cationic configurations with H+ as leading component and multiple isomer sulfated β‐CD (S‐β‐CD) as leading electrolyte (LE) additive, has been studied utilizing dynamic computer simulation, a calculation model based on steady‐state values of the ITP zones, and capillary ITP. By varying the amount of acidic S‐β‐CD in the LE composed of 3‐morpholino‐2‐hydroxypropanesulfonic acid and the chiral selector, and employing glycylglycine as terminating electrolyte (TE), inverse cationic ITP provides systems in which either both enantiomers, only the enantiomer with weaker complexation, or none of the two enantiomers form cationic ITP zones. For the configuration studied, the data reveal that only S‐methadone migrates isotachophoretically when the S‐β‐CD concentration in the LE is between about 0.484 and 1.113 mM. Under these conditions, R‐methadone migrates zone electrophoretically in the TE. An S‐β‐CD concentration between about 0.070 and 0.484 mM results in both S‐ and R‐methadone forming ITP zones. With >1.113 mM and < about 0.050 mM of S‐β‐CD in the LE both enantiomers are migrating within the TE and LE, respectively. Chiral inverse cationic ITP with acidic S‐β‐CD in the LE is demonstrated to permit selective ITP trapping and concentration of the less interacting enantiomer of a weak base.  相似文献   

19.
To optimize the capillary electrophoretic separation conditions for leucine enkephalin (LE) and the immune complex of the LE and anti-LE reaction, an analysis using a three-level, three-factorial Box-Behnken design was performed. Three separation parameters, buffer pH (X(1)), buffer concentration (X(2)), and applied voltage (X(3)), were chosen to observe the effect on separation responses. The responses were theoretical plate number, migration time of the LE peak, and resolution between the peaks. The optimum conditions and process validation were determined using statistical regression analysis and surface plot diagrams. The capillary electrophoresis optimum separation conditions were established to be 75 mM phosphate buffer at pH 7.00 with an applied separation voltage of 15 kV. By using the analysis technique, the prediction of responses was satisfactory and process verification yielded values within the +/-5% range of the predicted efficiency.  相似文献   

20.
A fast and simple method for the direct, simultaneous detection of nitrite (NO(2) (-)) and nitrate (NO(3) (-)) in rat striatum has been developed using a capillary electrophoresis separation of low-flow push-pull perfusion samples. The method was optimized primarily for nitrite because nitrite is more important physiologically and is found at lower levels than nitrate. We obtained a complete separation of NO(2) (-) and NO(3) (-) in rat striatum within 1.5 min. Optimal CE separations were achieved with 20 mM phosphate, 2 mM cetyltrimethylammonium chloride (CTAC) buffer at pH 3.5. The samples were injected electrokinetically for 2 s into a 40 cm x 75 microm ID fused-silica capillary. The separation voltage was 10 kV (negative polarity), and the injection voltage was 16 kV (negative polarity). UV detection was performed at 214 nm. The limits of detection obtained at a signal-to-noise ratio (S/N) of 3 for nitrite and nitrate were 0.96 and 2.86 microM. This is one of the fastest separations of nitrite and nitrate of a biological sample ever reported. Interference produced by the high physiological level of chloride is successfully minimized by use of CTAC in the run buffer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏