首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Monomethylated alkanes have been proposed to be contained in exhaled breath, their concentration pattern serving for identification of lung carcinoma, breast carcinoma and rejection of foreign tissue after heart transplant rejection. Improving the accuracy of identification for monomethylated alkanes will enhance work on their biochemical background which presently is unknown. The programmed temperature linear retention indices of all 196 C(4)-C(30) monomethylalkanes on OV-1 stationary phase were measured with an average repeatability of +/-0.07 index units (i.u.). The mixture of C(9)-C(30) monomethylalkanes was prepared by methylene insertion reaction to C(8)-C(29)n-alkanes mixture. The preliminary identification of monomethylalkanes was performed on the basis of the dependence of homomorphy factors on the number of carbon atoms of individual homologous series of monomethylalkanes (retention indices extrapolated with s=0.15 i.u.). The prediction of retention of isomers with new position of methyl group beginning at higher carbon atoms number, as well as for second, third, fourth, etc., member of homologous series allowed the dependence H(P)=f(C(n)) for first, second, third, etc., members of beginning homologous of monomethylalkane series (retention indices extrapolated with s=0.17 i.u.). The identification was confirmed by mass spectrometry. All gas chromatographic unseparated monomethylalkane isomers with methyl-group near the middle of molecule carbon chain were resoluted by mass spectrometric deconvolution. Obtained regular dependences H(P)=f(C(n)) allow precise retention prediction of monomethylalkanes C(30).  相似文献   

2.
In contrast to targeted analysis of volatile compounds, non-targeted approaches take information of known and unknown compounds into account, are inherently more comprehensive and give a more holistic representation of the sample composition. Although several non-targeted approaches have been developed, there's still a demand for automated data processing tools, especially for complex multi-way data such as chromatographic data obtained from multichannel detectors. This work was therefore aimed at developing a data processing procedure for gas chromatography mass spectrometry (GC–MS) data obtained from non-targeted analysis of volatile compounds. The developed approach uses basic matrix manipulation of segmented GC–MS chromatograms and PARAFAC multi-way modelling. The approach takes retention time shifts and peak shape deformations between samples into account and can be done with the freely available N-way toolbox for MATLAB. A demonstration of the new fingerprinting approach is presented using an artificial GC–MS data set and an experimental full-scan GC–MS data set obtained for a set of experimental wines.  相似文献   

3.
Comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS) is a powerful tool for comprehensive analysis of organic pollutants. In this study, we developed a powerful analytical method using GC × GC for rapid and accurate identification and quantification of compounds in environmental samples with complex matrices. Specifically, we have developed an automatic peak sentinel tool, T-SEN, with free programming software, R. The tool, which consists of a simple algorithm for on peak finding and peak shape identification, allows rapid screening of target compounds, even for large data sets from GC × GC coupled to high resolution time of flight mass spectrometry (HRTOFMS). The software tool automatically assigns and quantifies compounds that are listed in user databases. T-SEN works on a typical 64 bit workstation, and the reference calculation speed is 10–20 min for approximately 170 compounds for peak finding (five ion count setting) and integration from 1–2 GB of sample data acquired by GC × GC–HRTOFMS. We analyzed and quantified 17 PCDD/F congeners and 24 PCB congeners in a crude lake sediment extract by both GC × GC coupled to quadrupole mass spectrometry (qMS) and GC × GC–HRTOFMS with T-SEN. While GC × GC–qMS with T-SEN resulted in false identification and inaccurate quantification, GC × GC–HRTOFMS with T-SEN provided correct identification and accurate quantification of compounds without sample pre-treatment. The differences between the values measured by GC × GC–HRTOFMS with T-SEN and the certified values for the certified reference material ranged from 7.3 to 36.9% for compounds with concentrations above the limit of quantification. False positives/negatives were not observed, except for when co-elution occurred. The technique of GC × GC–HRTOFMS in combination with T-SEN provides rapid and accurate screening and represents a powerful new approach for comprehensive analysis.  相似文献   

4.
GC–MS optimization method including both advantages from chromatographic separation and mass spectrometric detection was designed for a set of 93 volatile organic compounds. Only a few experiments were necessary to determine the thermodynamic retention parameters for all compounds on a RTX-VMS column. From these data, computer simulation was used in order to predict the retention times of the compounds in temperature programmed gas chromatography. Then, an automatic selection of ions from the NIST database was performed and compared to the optimum conditions (full separation of VOC). This simulation-selection procedure was used to screen a numerous set of GC and MS conditions in order to quickly design a GC–MS method whatever the set of compounds considered.  相似文献   

5.
Malaria is one of the most widespread and deadly diseases on the planet. Every year, about 500 million new cases are diagnosed, and the annual death toll is about 3 million. Primaquine has strong antiparasitic effects against gametocytes and can therefore prevent the spread of the parasite from treated patients to mosquitoes. It is also used in radical cures and prevents relapse. Consequently, primaquine is an often-used drug. In this study the separation of unprocessed primaquine from the contaminant quinocide based on gas chromatography–mass spectrometry with supersonic molecular beam (SMB) is presented and 7.5 mg primaquine diphosphate tablets were analyzed. We present a novel method for fast determination of quinocide which is an isomer of primaquine as the main contaminant in unprocessed primaquine and in its medical form as tablets by gas chromatography–mass spectrometry with SMB (also named supersonic GC–MS). Supersonic GC–MS provides enhanced molecular ion without any ion source related peak tailing plus extended range of compounds amenable for GC–MS analysis. In addition, major isomer mass spectral effects were revealed in the mass spectra of primaquine and quinocide which facilitated the unambiguous identification of quinocide in primaquine tablets. Fast GC–MS analysis is demonstrated with less then 2 min elution time of the drug and its main contaminants.  相似文献   

6.
The gas chromatography mass spectrometry (GC–MS) deconvolution reporting software (DRS) from Agilent Technologies has been evaluated for its ability as a screening tool to detect a large number of pesticides in incurred and fortified samples extracted with acetone/dichloromethane/light petroleum (Mini-Luke method). The detection of pesticides is based on fixed retention times using retention time locking (RTL) and full scan mass spectral comparison with a partly customer built automated mass spectral deconvolution and identification system (AMDIS) database. The GC–MS was equipped with a programmable temperature vaporising (PTV) injector system which enables more sample to be injected. In a blind study of 52 real samples a total number of 158 incurred pesticides were found. In addition to the 85 pesticides found by manual interpretation of GC–NPD/ECD chromatograms, the DRS revealed 73 more pesticides (+46%). The DRS system also shows its potential to discover pesticides which are normally not searched for (EPN in long beans from Thailand). A spiking experiment was performed to blank matrices of apple, orange and lettuce with 177 different pesticides at concentration levels 0.02 and 0.1 mg/kg. The samples were analysed on GC–MS full scan and the AMDIS match factor was used as a mass spectral quality criterion. The threshold level of the AMDIS match factor was set at 20 to eliminate most of the false positives. AMDIS match factors from 20 up to 69 are regarded only as indication of a positive hit and must be followed by manual interpretation. Pesticides giving AMDIS match factors at ≥70 are regarded as identified. To simplify and decrease the large amount of data generated at each concentration level, the AMDIS match factors ≥20 was averaged (mean AMF) for each pesticide including the commodities and their replicates. Among 177 different pesticides spiked at 0.02 and 0.1 mg/kg level, the percentage of mean AMF values ≥70 were 23% and 80%, respectively. For 531 individual detections of pesticides (177 pesticides × 3 replicates) giving AMDIS match factor 20 in apple, orange and lettuce, the detection rates at 0.02 mg/kg were 71%, 63% and 72%, respectively. For the 0.1 mg/kg level the detection rates were 89%, 85% and 89%, respectively. In real samples some manual interpretation must be performed in addition. However, screening by GC–MS/DRS is about 5–10 times faster compared to screening with GC–NPD/ECD because the time used for manual interpretation is much shorter and there is no need for re-injection on GC–MS for the identification of suspect peaks found on GC–NPD/ECD.  相似文献   

7.
This review focuses on the possibilities and limits of nontarget screening of emerging contaminants, with emphasis on recent applications and developments in data evaluation and compound identification by liquid chromatography-high-resolution mass spectrometry (HRMS). The general workflow includes determination of the elemental composition from accurate mass, a further search for the molecular formula in compound libraries or general chemical databases, and a ranking of the proposed structures using further information, e.g., from mass spectrometry (MS) fragmentation and retention times. The success of nontarget screening is in some way limited to the preselection of relevant compounds from a large data set. Recently developed approaches show that statistical analysis in combination with suspect and nontarget screening are useful methods to preselect relevant compounds. Currently, the unequivocal identification of unknowns still requires information from an authentic standard which has to be measured or is already available in user-defined MS/MS reference databases or libraries containing HRMS spectral information and retention times. In this context, we discuss the advantages and future needs of publicly available MS and MS/MS reference databases and libraries which have mostly been created for the metabolomic field. A big step forward has been achieved with computer-based tools when no MS library or MS database entry is found for a compound. The numerous search results from a large chemical database can be condensed to only a few by in silico fragmentation. This has been demonstrated for selected compounds and metabolites in recent publications. Still, only very few compounds have been identified or tentatively identified in environmental samples by nontarget screening. The availability of comprehensive MS libraries with a focus on environmental contaminants would tremendously improve the situation.  相似文献   

8.
A novel selectable one-dimensional (1D) or two-dimensional (2D) gas chromatography–mass spectrometry (selectable 1D/2D GC–MS) system with selective detection was developed by using capillary flow technology and low thermal mass GC (LTM-GC). The main advantages of this system are the simple and fast selection of 1D GC–MS or 2D GC–MS operation without any instrumental set-up change (e.g.2D GC–MS can be run just after 1D GC–MS run), and simultaneous mass spectrometric and olfactometry or element-specific detection for both 1D and 2D separation to assure selection of a heart-cut region and correct identification of compounds of interest. The feasibility and benefit of the proposed system with selective detection, e.g. olfactometry, nitrogen phosphorus detection (NPD), and pulsed flame photometric detection (PFPD), was demonstrated with an identification of trace amounts of aroma components in beverages (beer and coffee). Using stir bar sorptive extraction (SBSE) and selectable 1D/2D GC–Olfactometry/MS on a beer sample, β-damascenone could be determined at 1.9 ng mL−1 (RSD 3.1%, n = 6) as a potent aroma compound. In a coffee sample, two odor active compounds were clearly resolved from a 4.2 s heart-cut and were assigned probable identifications as 4,5-dimethyl thiazole and dimethyl trisulfide based on a NIST library search, dual linear retention indices (dual LRI) and elemental information obtained by SBSE in combination with selectable 1D/2D GC–NPD/PFPD/MS.  相似文献   

9.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

10.
Comprehensive two-dimensional gas chromatography (GC × GC) was applied to the study of cachaça production. Effects of bidistillation, and the use of charcoal filtration in the production of artisan cachaça, as well as the effects of multi-distillation on volatile products in commercial cachaça were investigated. Volatile compounds were collected and concentrated onto a polyacrylate solid-phase microextraction fibre, and analyzed using GC × GC on a non-polar (BPX5)–polar (BP20) column set. More than 100 compounds, comprising various homologous series were tentatively identified using MS library matching and comparison with retention indices. Phthalate organic contamination following the use of ion exchange resin for removal of copper ion was evident. Charcoal successfully removes this contamination product. Prediction of compounds within particular homologous series aids component identification.  相似文献   

11.
Hyphenated techniques such as gas chromatography–mass spectrometry (GC–MS) or high-performance liquid chromatography–mass spectrometry (LC–MS) produce a large amount of data in a form of two-way data matrix. It has been a great challenge to furthest extract the useful information from the data. In this work, a chemometric approach based on a modification of adaptive immune algorithm (AIA) was proposed for a high-throughput analysis of the multicomponent overlapping GC–MS signals. With the proposed method, the chromatographic profile of each component in an overlapping signal can be extracted independently and sequentially along the retention time. In order to show the efficiency of the method, a stimulated GC–MS data of six components with background and an experimental GC–MS data of 40 pesticides were investigated. It was found that the multicomponent overlapping GC–MS signals could be fast and accurately resolved. Furthermore, the quantitative property of the extracted information was also investigated. The correlation coefficients (r) between the peak area and the added volumes of the sample are in the range 0.9658–0.9953.  相似文献   

12.
The mass spectral characteristics of wax esters were systemically summarized and interpreted through data mining of their standard mass spectra taken from NIST standard mass spectral library. Combining with the rules of retention indices described in the previous study, an automatic system was subsequently developed to identify the structural information for wax esters from GC/MS data. After tested and illustrated by both simulated and real GC/MS data, the results indicate that this system could identify wax esters except the polyunsaturated ones and the mass spectral characteristics are useful and effective information for identification of wax esters.  相似文献   

13.
Natural product screening in plants has always been a difficult task due to the complex nature of the plant material and diverse structures of the compounds present in them. Flavonoids are important and diverse class of plant secondary metabolites with numerous medicinal activities. The present study focuses on the development of a high-resolution tandem mass spectral library for the rapid and authentic identification of common flavonoids. A total of forty flavonoid standards belong to class flavones, isoflavones, flavanones, flavanols and anthocyanins were pooled into two solutions applying logP-based strategy. The flavonoids were analyzed using LC-QTOF-MS high-resolution mass spectrometer with optimization of different instrumental parameters to achieve good sensitivity. The library was built by incorporating names, molecular formulae, exact masses, and MS, and MS/MS spectra of analyzed flavonoids using Bruker Library Editor tool. The fragmentation pattern observed for the standard compounds were compared to the fragments reported in the literature. To assess the practical implications, an extract of tea sample was analyzed and screened using the developed library, which resulted in the identification of three common flavonoids based on their HR-ESI-MS/MS spectral features. The established LC-HR-MS/MS method can be used for the targeted identification of flavonoids in complex samples like food material from different botanical families.  相似文献   

14.
Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography–mass spectrometry (GC–MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.  相似文献   

15.
“Substitution therapy” and the use of buprenorphine (B) as an agent for treating heroin addiction continue to gain acceptance and have recently been implemented in Taiwan. Mature and widely utilized gas chromatography–mass spectrometry (GC–MS) technology can complement the low cost and highly sensitive immunoassay (IA) approach to facilitate the implementation of analytical tasks supporting compliance monitoring and pharmacokinetic/pharmacogenetic studies. Issues critical to GC–MS analysis of B and norbuprenorphine (NB) (free and as glucuronides), including extraction, hydrolysis, derivatization, and quantitation approaches were studied, followed by comparing the resulting data against those derived from IA and two types of liquid chromatography–tandem mass spectrometry (LC–MS/MS) methods. Commercial solid-phase extraction devices, highly effective for recovering all metabolites, may not be suitable for the analysis of free B and NB; acetyl-derivatization products exhibit the most favorable chromatographic, ion intensity, and cross-contribution characteristics for GC–MS analysis. Evaluation of IA, GC–MS, and LC–MS/MS data obtained in three laboratories has proven the 2-aliquot GC–MS protocol effective for the determination of free B and NB and their glucuronides.  相似文献   

16.
Two screening methods have been developed for simultaneous determination of ten extensively used personal care products (PCPs) and two alkylphenol surfactants in fish. The methods consisted of extraction, clean-up, derivatization and analysis by gas chromatography–mass spectrometry with selected ion monitoring (GC–SIM–MS) or gas chromatography–tandem mass spectrometry (GC–MS/MS) techniques. Among solvents tested to assess recovery of target compounds from 1-g tissue homogenates, acetone was selected as optimal for extracting compounds with dissimilar physicochemical properties from fish tissue. Initial experiments confirmed that GC–SIM–MS could be applied for analysis of lean fillet tissue (<1% lipid) without gel-permeation chromatography (GPC), and this approach was applied to assess the presence of target analytes in fish fillets collected from a regional effluent-dominated stream in Texas, USA. Benzophenone, galaxolide, tonalide, and triclosan were detected in 11 of 11 environmental samples at concentrations ranging from; 37 to 90, 234 to 970, 26 to 97, and 17 to 31 ng/g, respectively. However, performance of this analytical approach declined appreciably with increasing lipid content of analyzed tissues. Successful analysis of samples with increased lipid content was enabled by adding GPC to the sample preparation protocol and monitoring analytes with tandem mass spectrometry. Both analytical approaches were validated using fortified fillet tissue collected from locations expected to be minimally impacted by anthropogenic influences. Average analyte recoveries ranged from 87% to 114% with RSDs <11% and from 54% to 107% with RSDs <20% for fish tissue containing <1% and 4.9% lipid, respectively. Statistically derived method detection limits (MDLs) for GC–SIM–MS and GC–MS/MS methodologies ranged from 2.4 to 16 ng/g, and 5.1 to 397 ng/g, respectively.  相似文献   

17.
A sensitive method has been developed for the trace analysis of PAHs and their oxidation products (i.e., nitro-, oxy-, and hydroxy-PAHs) in air particulate matter (PM). Following PM extraction, PAHs, nitro-, oxy-, and hydroxy-PAHs were fractionated using solid phase extraction (SPE) based on their polarities. Gas chromatography–mass spectrometry (GC–MS) conditions were optimized, addressing injection (i.e., splitless time), negative-ion chemical ionization (NICI) parameters, i.e., source temperature and methane flow rate, and MS scanning conditions. Each class of PAH oxidation products was then analyzed using the sample preparation and appropriate ionization conditions (e.g., nitro-PAHs exhibited the greatest sensitivity when analyzed with NICI–MS while hydroxy-PAHs required chemical derivatization prior to GC–MS analysis). The analyses were performed in selected-ion-total-ion (SITI) mode, combining the increased sensitivity of selected-ion monitoring (SIM) with the identification advantages of total-ion current (TIC). The instrumental LODs determined were 6–34 pg for PAHs, 5–36 pg for oxy-PAHs, and 1–21 pg for derivatized hydroxy-PAHs using electron ionization (GC-EI-MS). NICI–MS was found to be a useful tool for confirming the tentative identification of oxy-PAHs. For nitro-PAHs, LODs were 1–10 pg using negative-ion chemical ionization (GC-NICI-MS). The developed method was successfully applied to two types of real-world PM samples, diesel exhaust standard reference material (SRM 2975) and wood smoke PM.  相似文献   

18.
Different analytical methods were optimized and applied to quantify certain surrogate contaminants (toluene, chlorobenzene, phenol, limonene and benzophenone) in samples of contaminated and recycled flakes and virgin pellets of polyethylene terephthalate (PET) coming from the industrial challenge test. A screening analysis of the PET samples was carried out by direct solid-phase microextraction (SPME) in headspace mode (HS). The methods developed and used for quantitative analysis were a) total dissolution of PET samples in dichloroacetic acid and analysis by HS-SPME coupled to gas chromatography–mass spectrometry (GC–MS) and, b) dichloromethane extraction and analysis by GC–MS. The concentration of all surrogates in the contaminated PET flakes analyzed by HS-SPME method was lower than expected according to information provided by the supplier. Dichloroacetic acid interacted with the surrogates, resulting in a tremendous decrease of limonene concentration. The degradation compounds from limonene were identified. Dichloromethane extraction and GC–MS analysis evidenced the highest values of analytes in these PET samples. Based on the foregoing data, the efficiency of the recycling process was evaluated, whereby the removal of 99.9% of the surrogates proceeding from the contaminated flakes was confirmed.  相似文献   

19.
A fast gas chromatography–mass spectrometry (GC–MS) method with minimum sample preparation is described for early diagnosis of tuberculosis (TB). The automated procedure is based on the injection of sputum samples which are then methylated inside the GC injector using thermally assisted hydrolysis and methylation (THM). The THM–GC–MS procedure was optimized for the injection of sputum samples. For the identification of Mycobacterium tuberculosis the known marker tuberculostearic acid (TBSA) and other potential markers were evaluated. Hexacosanoic acid in combination with TBSA was found to be specific for the presence of M. tuberculosis. For validation of the method several sputum samples with different viscosities spiked with bacterial cultures were analyzed. Finally, 18 stored sputum samples collected in Vietnam from patients suspected to suffer from TB were re-analyzed in Amsterdam by microscopy after decontamination/concentration and using the new THM–GC–MS method. No false positives were found by THM–GC–MS and all patients who were diagnosed with TB were also found positive using our newly developed THM–GC–MS method. These results show that the new fast and sensitive THM–GC–MS method holds great potential for the diagnosis of TB.  相似文献   

20.
Fruit flavour is the combination of numerous biochemicals: sugars for sweetness, acids for sourness and volatile metabolites for aroma. The objective of this study was to establish a method to develop a target list of statistically relevant compounds for the characterization of melon from non-targeted data, while preserving the profile information. Five different varieties were sampled (sampling 12 biological replicates from 12 plants) using dynamic headspace extraction, then analysed by gas chromatography–mass spectrometry in full scan mode. Using Metalign and SIMCA-P software the raw data was spectrally aligned and then subjected to principal component analysis (PCA). The principal component analysis plot showed good separation of the five varieties based on their full scan GC–MS profile. Mass spectral data points responsible for the differences between varieties were highlighted by further statistical analysis. The mass spectra were then reconstructed and the corresponding chemicals identified using library search or reference standards were available to create a new target component list. To validate the new target list, the initial data set was re-processed using the targeted approach and the results subjected again to principal component analysis. The two representations showed excellent agreement on the separation of the five varieties. The new target list obtained from this study can be applied to differentiate and characterize the volatile profile of melon varieties using a list of statistically significant compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号