首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new HPLC-UV-Vis method for identification of drying oils from binding media or protective film used in pictorial works of art prior to conservation or restoration is proposed. Chromophore derivatization of fatty acids released by hydrolysis of structural drying oils is studied. The derivatization reagent selected was 2-nitrophenylhydrazine with 1-ethyl-3-(3-dimethyl animopropyl)carbodiimide hydrochloride/pyridine as catalyst. This reaction was carried out using microwave heating. Mobile phase was methanol/water/n-propanol/acetic acid (80:14:5:1) running in isocratic mode. Absorbance was measured at 400 nm. In these conditions, hydrazides of myristic, palmitic, oleic, and stearic acids were satisfactorily resolved. Method shows good sensitivity, with a detection limit of 15 μmol l−1, and good linearity between 0.03 and 3 mmol l−1. Peak area ratios among fatty acids derivatives allows identification of the drying oils. The stearic/palmitic ratio is the most important, because it allows to differentiate among the different drying oils. The proposed method has been successfully applied to real samples from items of the cultural heritage of Valencia (Spain).  相似文献   

2.
As a result of the heterogeneous nature of lipid classes in complex biological matrices such as plasma and erythrocytes, it is imperative to have a robust and validated methodology for fatty acid quantification. The effective method presented here combines available methodology of fast gas chromatography and an improvement of the sample preparation methodology before injection into the gas chromatograph. This methodology ensures complete transesterification and quantification of total and individual fatty acids (and not only in relative amounts) by addition of internal standards. We considered sample preparation key, and we established the use of lysis buffer and ethanol for erythrocytes and plasma sample preparation, respectively. Fatty acid profile was determined by acid methylation and fast gas chromatography equipped with a flame ionization detector. The triacylglycerol 13:0, phosphatidylcholine 23:0, and methyl esters 21:0 were used as internal standards. Within the linearity of the calibration, the ratio of the peak area of each fatty acid over the peak area of the internal standard was constant (coefficient of variation ≤ 2.5). Satisfactory repeatability <15% and intermediate reproducibility < 15% were observed. Finally, this validated method was applied to a pre‐clinical trial that investigated the impact of dietary fats on accretion of specific fatty acids in plasma and erythrocytes.  相似文献   

3.
A microwave assisted wet digestion method for organoarsenic compounds and subsequent determination of total arsenic in aqueous, biological and sediment samples by means of flow injection hydride generation electrothermal atomic absorption spectrometry (FI-HG-ETAAS) is described. Sodium persulfate, sodium fluoride and nitric acid serve as digestion reagents, which allow a quantitative transformation of organoarsenic compounds to hydride forming species in a commercial microwave sample preparation system. The maximum operating pressures of the applied tetrafluorometoxil (TFM) liners are 75 bar (high pressure vessels) and 30 bar (medium pressure vessels), corresponding to maximum solution temperatures of 300 and 260 °C. For the investigated samples, digestion temperatures of 210-230 °C (medium pressure vessels) and 240-280 °C (high pressure vessels) were obtained.In medium pressure vessels, arsenic recovery from aqueous testing solutions of dimethylarsinic acid (DMA), phenylarsonic acid (PAA) and tetraphenylarsonium chloride (TPA) at initial concentrations of 100 and 10 μg l−1 is complete, even in the presence of an excess of organic carbon (potassium hydrogen phthalate, 2000 mg l−1) or fatty acids (linolenic acid 70%; linoleic acid ≈20-25%; Oleic acid ≈3%, 900-4500 mg l−1).Arsenic recovery from aqueous arsenobetaine (ASB) solutions with the same initial concentrations is also complete if high pressure vessels and a higher concentration of fluoride ions are used, whereas the addition of organic carbon (potassium hydrogen phthalate, 2000 mg l−1, fatty acids, 900-4500 mg l−1) leads to a decrease in arsenic recovery of about 2-5%. In all cases, residual carbon contents are close to the limit of detection for the applied analytical method (15 mg l−1).Results of arsenic analysis in reference standard materials revealed a significant dependence on the material’s nature (sediment samples, plant materials and seafood samples). Sediment samples and plant materials show recoveries for arsenic around 100% after a single-step digestion in medium pressure TFM liners. Seafood (fish/lobster/mussel samples) usually require either the use of high pressure vessels or a second digestion step, if medium pressure vessels are used.  相似文献   

4.
Docosanoic (C22), tetracosanoic (C24) and hexacosanoic (C26) acids are saturated very-long-chain fatty acids (VLCFA) present at trace levels in biosamples. VLCFA can be used as potential biomarkers for the diagnosis of hereditary diseases such as X-linked adrenoleukodystrophy. Because the analytes to be detected are at trace levels, a sensitive fluorimetric liquid chromatographic method was developed to analyze VLCFA in plasma. The method is simple based on extracting VLCFA from plasma with toluene, and the obtained toluene extract was subject to the derivatization of VLCFA with a fluorescent reagent 2-(2-naphthoxy)ethyl-2-(piperidino)ethanesulfonate (NOEPES) without solvent evaporation/replacement. The resulting fluorescent derivatives were monitored by fluorimetric detection (excitation at 225 nm and emission at 360 nm), giving a high sensitivity with the limit of detection about 5.0 nM (S/N = 3, 10 μL injected) of the analytes. Application of the method to the analysis of VLCFA in the plasma of patients with adrenoleukodystrophy proved practical and effective.  相似文献   

5.
A method for the determination of fatty acids in serum based on GC–MS (micro-SIS detection mode) has been developed and the separation and cis/trans isomers have been identified. A prior two-step extraction/derivatization procedure accelerated by ultrasound allows individual determination of esterified (EFAs) and non-esterified fatty acids (NEFAs), and shortening of the derivatization steps to 5 min for EFAs and 15 min for NEFAs. The total analysis time for 39 fatty acids was 61 min. The minimum LOD and LOQ values were 0.002 and 0.006 μg/ml, respectively. The proposed method was validated for EFAs and NEFAs using two different methods and the results show no statistical differences between the proposed method and those used as reference. The proposed derivatization–extraction methodology is suitable for fatty-acid analysis of human serum, and can be applied to nutritional and epidemiological studies.  相似文献   

6.
This work presents an high-performance liquid chromatography method for the determination of amino acids after precolumn derivatization with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) which can readily react with both primary and secondary amines. The precolumn derivatization conditions, including the CNBF concentration, reaction pH, temperature and reaction time were investigated for method optimization. In pH 9.0 borate buffer, the reaction of amino acids with CNBF was carried out at 60 °C for 30 min, the optimized concentration of CNBF was 70 mmol L−1 and the molar ratio of amino acids to CNBF was 1:5.25. The chromatographic separation of 19 amino acids derivatives was performed on a Kromasil ODS C18 column (250 mm × 4.6 mm, 5 μm) with good reproducibility, and ultraviolet detection was applied at 260 nm. The mobile phase was a mixture of phase A (acetonitrile) and phase B (acetate buffer, acetonitrile, triethylamine; 82.8:17:0.2, pH 4.9), and the flow rate was 0.4 mL min−1. The separation of all the labeled amino acids was achieved within 45 min at room temperature by gradient elution mode. The method linearity, calculated for each amino acid, had a correlation coefficient higher than 0.9979, in concentrations ranging from 9.60 to 3330.00 μmol L−1. The detection limits of amino acids were 2.40-6.50 μmol L−1, at a signal-to-noise ratio of 3. The proposed method was applied for the determination of amino acids in beer with recoveries of 97.0-103.9% and relative standard deviations of 2.62-4.22%, respectively. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

7.
Eva María Seco-Gesto 《Talanta》2007,72(3):1178-1185
Studies on the application of a short microwave irradiation cycle and the use of diluted acids to extract trace elements from raft mussel samples were developed. Multi-element determinations (Al, Ba, Cd, Cr, Cu, Fe, Mn, Pb, Sn, V and Zn) were carried out by inductively coupled plasma-optical emission spectrometry (ICP-OES). Parameters such as acid/oxidizing reagents (diluted nitric acid, hydrochloric acid and hydrogen peroxide) concentrations, acid/oxidizing solution volume, temperature, ramp time and hold time for the microwave heating were simultaneously studied by using an experimental design approach. The optimum conditions have showed the sample pre-treatment of 10 mussel samples to less than 3.0 min when a microwave power of 600 W and a controlled temperature of 65 °C were used. This time (hold time plus ramp time) is quite shorter than those reported for conventional microwave-assisted acid digestion procedures. Since temperature inside the reactor is not high, the venting time can be shorted to 15 min. In addition, the concentration of acid/oxidizing reagents needed to complete the acid leaching (2.5 M, 3.0 M and 0.5 % (m/v) for nitric acid, hydrochloric acid and hydrogen peroxide, respectively) is lower than the required concentration for a conventional microwave-assisted acid digestion (concentrated acids). The proposed method has showed a good repeatability of the overall method, and relative standard deviations between 11 and 2% were reached for 12 replicate microwave-assisted acid leaching and ICP-OES measurements. The method was finally validated by analyzing TORT-1 and GBW-08571 certified reference materials and it was successfully applied to fast multi-element determinations in several raft mussel samples.  相似文献   

8.
In this study, a novel fatty-acid-based in-tube dispersive liquid–liquid microextraction (FA-IT-DLLME) technique is proposed for the first time and is developed as a simple, rapid and eco-friendly sample extraction method for the determination of alkylphenols in aqueous samples using high-performance liquid chromatography–ultraviolet detection (HPLC–UV). In this extraction method, medium-chain saturated fatty acids were investigated as a pH-dependent phase because they acted as either anionic surfactants or neutral extraction solvents based on the acid–base reaction caused solely by the adjustment of the pH of the solution. A specially designed home-made glass extraction tube with a built-in scaled capillary tube was utilized as the phase-separation device for the FA-IT-DLLME to collect and measure the separated extractant phase for analysis. Nonylphenol (NP) and 4-tert-octylphenol (4-tOP) were chosen as model analytes. The parameters influencing the FA-IT-DLLME were thoroughly investigated and optimized. Under the optimal conditions, the detector responses of NP and 4-tOP were linear in the concentration ranges of 5–4000 μg L−1, with correlation coefficients of 0.9990 and 0.9996 for NP and 4-tOP, respectively. The limits of detection based on a signal-to-noise ratio of 3 were 0.7 and 0.5 μg L−1, and the enrichment factors were 195 and 143 for NP and 4-tOP, respectively. The applicability of the developed method was demonstrated for the analysis of alkylphenols in environmental wastewater samples, and the recoveries ranged from 92.9 to 107.1%. The extraction process required less than 4 min and utilized only acids, alkalis, and fatty acids to achieve the extraction. The results demonstrated that the presented FA-IT-DLLME approach is highly cost-effective, simple, rapid and environmentally friendly in its sample preparation.  相似文献   

9.
10.
Rapid analytical method for the simultaneous separation and determination of amines and organic acids is a vital interest for quality control of citrus and their products. In the present study, a simultaneous high performance liquid chromatography (HPLC) method for the rapid separation of three amines and two organic acids was developed. Chromatographic separation of compounds was achieved using Xbridge C18 column at ambient temperature, with an isocratic mobile phase of 3 mM phosphoric acid at a flow rate of 1.0 mL min−1. A photodiode array (PDA) detector was used to monitor the eluent at 223 nm and 254 nm with a total analysis time of 10 min. Extraction of amines and organic acids from citrus juice was optimized. The method was validated by tests of linearity, recovery, precision and ruggedness. The limit of detection (LOD) and limit of quantification (LOQ) for amines and ascorbic acid were determined to be 5 ng and 9.8 ng, respectively. All calibration curves showed good linearity (R2 ≥ 0.9999) within the test ranges. The recoveries of the amines and organic acids ranged between 84% and 117%. The identity of each peak was confirmed by mass spectral (MS) analysis. The developed method was successfully applied to analyze the content of amines and organic acids in six different species and two varieties of citrus. Results indicate that mandarin and Marrs sweet orange contain high level of amines, while pummelo and Rio Red grapefruit had high content of ascorbic acid (137-251 μg mL−1) and citric acid (5-22 mg mL−1). Synephrine was the major amine present in Clementine (114 μg mL−1) and Marrs sweet orange (85 μg mL−1). To the best of our knowledge, this is the first report on simultaneous separation and quantification of amines and organic acids in Marrs sweet orange, Meyer lemon, Nova tangerine, Clementine, Ugli tangelo and Wekiwa tangelo.  相似文献   

11.
A microwave-assisted persulfate oxidation method followed by ion chromatographic determination of nitrate was developed for total nitrogen determination in atmospheric wet and dry deposition samples. Various operating parameters such as oxidation reagent concentrations, microwave power, and extraction time were optimized to maximize the conversion of total nitrogen to nitrate for subsequent chemical analysis. Under optimized conditions, 0.012 M K2S2O8 and 0.024 M NaOH were found to be necessary for complete digestion of wet and dry deposition samples at 400 W for 7 min using microwave. The optimized extraction method was then validated by testing different forms of organic nitrogen loaded to pre-baked filter substrates and NIST SRM 1648 (urban particulate matter), and satisfactory results were obtained. In the case of wet deposition samples, standard addition experiments were performed. The suitability of the method for real-world application was assessed by analyzing a number of wet and dry deposition samples collected in Singapore during the period of March-April 2007. The organic nitrogen content was 15% (wet) and 30% (dry) of the total nitrogen. During the study period, the estimated wet fluxes for nitrate (NO3), ammonium (NH4+), organic nitrogen (ON), and total nitrogen (TN) were 16.1 ± 6.5 kg ha−1 year−1, 11.5 ± 5.7 kg ha−1 year−1, 3.8 ± 1.5 kg ha−1 year−1and 31.5 ± 13.2 kg ha−1 year−1, respectively, while the dry fluxes were 2.5 ± 0.8 kg ha−1 year−1, 1.4 ± 0.9 kg ha−1 year−1, 2.3 ± 1.4 kg ha−1 year−1 and 7.5 ± 2.6 kg ha−1 year−1, respectively.  相似文献   

12.
A rapid gas chromatographic method for the determination of medium-chain and long-chain free fatty acids (C14:0 to C24:0 fatty acids) from different biological specimens is presented. After a rapid one-step transesterification method in methanol-acetyl chloride (50:1, v/v), fatty acid methyl esters were extracted into n-hexane and analysed on a 15-m Durabond-Wax column within a 12-min chromatographic run. The detection limit is 500 pg per injection.  相似文献   

13.
A quantitative method for the determination of organic acids in atmospheric particles is developed. The method couples a derivatisation step (thermally assisted hydrolysis and methylation) and a Curie point pyrolyser as a thermal desorption technique and gas chromatography–mass spectrometry (CPP-GC–MS). Among the reagents tested (tetramethylammonium hydroxide (TMAH), tetramethylammonium acetate (TMAAc) and phenyltrimethylammonium hydroxide (TMPAH)), the best performance was found using TMAAc as a derivatisation reagent for the reaction time of 4 s at 510 °C as heating temperature. Calibration was performed for a series of fatty acids (FA), dicarboxylic acids (DCA) and terpenoic acids (TA) under these conditions. Coefficients of determination (R2) were between 0.94 and 0.98. Limits of detection (LOD) were in the nanogram-range between 0.1 and 3.6 ng. The method is applied on atmospheric particle samples to obtain the quantification reproducibility and quantification limits. Reproducibility was determined in terms of relative standard deviations (RSD) for ambient aerosol samples collected by a high-volume-sampler (HVS, RSD = 6–45%, n = 10) and a Berner impactor (BI, RSD = 5–34%, n = 10). Based on 24 h sampling time the developed method enables quantification of all three classes of acids for both sampling techniques. Calibration data and presented volume concentrations are compared with literature data. A comparison with an off-line methylation-GC–MS using BF3 as a derivatisation reagent and capillary electrophoresis coupled mass spectrometry (CE-MS) showed a good agreement. Minimal sample preparation is the main advantage of the developed method. Depending on the sensitivity requirements the present method can be a fast and simple alternative to GC–MS techniques with conventional sample preparation steps for semi-volatile organic acids.  相似文献   

14.
In the present study, an analytical procedure was developed for the determination of short-chain fatty acids (SCFAs) in landfill leachate and municipal wastewater employing injection of aqueous samples to gas chromatograph with flame ionization detector (GC-FID). Chromatographic conditions such as a separation system, injection volume, oven temperature program were investigated and selected. With two columns, one with a polar (polyethylene glycol) and one with a non-polar (dimethylpolisiloxane) stationary phase, good separation of SCFAs, containing from 2 to 8 carbon atoms, was achieved. The sample volume was 2 μL and the temperature program 80 °C (30 s) then 7 °C min−1 to 220 °C (2 min). LOQs values were below 0.25 mg L−1. The concentrations of the acids in the landfill leachate studied ranged from 0.45 ± 0,059 (average ± extended uncertainty) mg L−1 for pentanoic acid to 15.2 ± 0.73 mg L−1 for ethanoic acid. Concentrations of SCFAs in the municipal wastewater were lower than LOQs.  相似文献   

15.
A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min−1. The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g−1. The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required.  相似文献   

16.
Xu X  Su R  Zhao X  Liu Z  Li D  Li X  Zhang H  Wang Z 《Talanta》2011,85(5):2632-2638
A simple method based on simultaneous microwave-assisted derivatization and ionic liquid-based dispersive liquid-liquid microextraction (IL-based DLLME) is proposed for the derivatization, extraction and preconcentration of formaldehyde in beverage samples prior to the determination by high-performance liquid chromatography (HPLC). Formaldehyde was in situ derivatized with 2,4-dinitrophenylhydrazine (DNPH) and simultaneously extracted and preconcentrated by using microwave-assisted derivatization and IL-based DLLME in a single step. Several experimental parameters, including type and volume of extraction solvent, type and volume of disperser, microwave power and irradiation time, volume of DNPH, pH of sample solution, and ionic strength were evaluated. When the microwave power was 120 W, formaldehyde could be derivatized and extracted simultaneously only within 90 s. Under optimal experimental conditions, good linearity was observed in the range of 0.5-50 ng/mL with the correlation coefficient of 0.9965, and the limit of detection was 0.12 ng/mL. The proposed method was applied to the analysis of different beverage samples, and the recoveries of formaldehyde obtained were in the range of 84.9-95.1% with the relative standard deviations lower than 8.4%. The results showed that the proposed method was a rapid, convenient and feasible method for the determination of formaldehyde in beverage samples.  相似文献   

17.
Comprehensive two-dimensional gas chromatography (GC × GC) offers an interesting tool for profiling bacterial fatty acids. Flow modulated GC × GC using a commercially available system was evaluated, different parameters such as column flows and modulation time were optimized. The method was tested on bacterial fatty acid methyl esters (BAMEs) from Stenotrophomonas maltophilia LMG 958T by using parallel flame ionization detector (FID)/mass spectrometry (MS). The results are compared to data obtained using a thermal modulated GC × GC system. The data show that flow modulated GC × GC-FID/MS method can be applied in a routine environment and offers interesting perspectives for chemotaxonomy of bacteria.  相似文献   

18.
Fatty acid methyl esters (FAMEs) of pure triglyceride standards, oils, and fat from dry matrixes were formed by transesterification using sodium methoxide in methanol-hexane. FAMEs were produced by direct addition of sodium methoxide-hexane to samples and heating to simultaneously extract and transesterify acyl lipids. FAMEs were quantitated by capillary gas chromatography (GC) over a fatty acid concentration range of 0 to 1.7 mg/mL (r > or = 0.9997). Total fat was calculated as the sum of individual fatty acids expressed as triglyceride equivalents, in accordance with nutrition labeling guidelines. Saturated, polyunsaturated, and monounsaturated fats were calculated as sums of individual free fatty acids. Absolute recoveries determined from individual fatty acids in test samples ranged from 69.7 to 106%. Recoveries (relative to the C13:0 internal standard) for individual fatty acids in test samples ranged from 95 to 106%. Reproducibility was constant at each fatty acid level in the reaction mixture (n = 5, coefficient of variation [CV] < 2%). Absolute recovery determined from the sum of total fatty acids in standard reference material (SRM) 1846 (powdered infant formula) was 96.4%. Analysis of SRM 1846 gave results that agreed closely with the certified fat and fatty acid values. Analysis of commercial infant formula gave results that were comparable to those obtained with AOAC Method 996.01. The direct extraction methylation procedure is rapid, and the transesterification of acyl lipids to form FAMEs is complete within 15 min. Classical saponification and refluxing are not required. This method provides FAMEs free of interferences and easily quantitated by GC or confirmed by GC/mass spectrometry (MS). Unambiguous MS identification of individual FAMEs derived from pure standards, SRM 1846, and powdered infant formula product was obtained.  相似文献   

19.
A method based on solid-phase microextraction (SPME) and post-derivatization on the fiber coupled to gas chromatography–mass spectrometry (GC–MS) was developed for the analysis of fatty acids in sputum from patients with pulmonary tuberculosis. The sputum specimens were digested, hydrolyzed, extracted, derivertized, injected and analyzed without cultivation or isolation of the microorganism. Under optimized conditions, the relative standard deviations (RSD, n = 5) for all analytes were below 17% and the limits of detection varied from 1.68 (C24:0) to 150.4 μg L−1 (C12:0). Good linearity was observed for all the fatty acids studied except for C12:0 within a wide concentration range of three orders of magnitudes with the correlation coefficients ranging from 0.91 (C24:0) to 0.99 (C14:0). Fatty acids in sputum specimens from 21 persons were directly analyzed using the proposed method. The results show that in all the sputum specimens from patients, who were clinically diagnosed with tuberculosis (TB), tuberculosis stearic acid (TBSA) was detected, while in all the sputum samples from persons without TB, TBSA was not found. The possibility of using the proposed method to detect mycobacterium tuberculosis (MTB) via the identification of TBSA in sputum was discussed. The comparison with other methods including sputum culture and microscopy of direct smears indicated that the proposed method is fast and sensitive for the analysis of fatty acids in sputum and offers an alternative for the detection of MTB in sputum.  相似文献   

20.
The concept of sequential injection chromatography (SIC) was exploited to automate the fluorimetric determination of amino acids after pre-column derivatization with o-phthaldialdehyde (OPA) in presence of 2-mercaptoethanol (2MCE) using a reverse phase monolithic C18 stationary phase. The method is low-priced and based on five steps of isocratic elutions. The first step employs the mixture methanol: tetrahydrofuran: 10 mmol L−1 phosphate buffer (pH 7.2) at the volumetric ratio of 8:1:91; the other steps use methanol: 10 mmol L−1 phosphate buffer (pH 7.2) at volumetric ratios of 20:80, 35:65, 50:50 and 65:35. At a flow rate of 10 μL s−1 a 25 mm long-column was able to separate aspartic acid (Asp), glutamic acid (Glu), asparagine (Asn), serine (Ser), glutamine (Gln), glycine (Gly), threonine (Thr), citruline (Ctr), arginine (Arg), alanine (Ala), tyrosine (Tyr), phenylalanine (Phe), ornithine (Orn) and lysine (Lys) with resolution >1.2 as well as methionine (Met) and valine (Val) with resolution of 0.6. Under these conditions isoleucine (Ile) and leucine (Leu) co-eluted. The entire cycle of amino acids derivatization, chromatographic separation and column conditioning at the end of separation lasted 25 min. At a flow rate of 40 μL s−1 such time was reduced to 10 min at the cost of resolution worsening for the pairs Ctr/Arg and Orn/Lys. The detection limits varied from 0.092 μmol L−1 for Tyr to 0.51 μmol L−1 for Orn. The method was successfully applied to the determination of intracellular free amino acids in the green alga Tetraselmis gracilis during a period of seven days of cultivation. Samples spiked with known amounts of amino acids resulted in recoveries between 94 and 112%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号