首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, the analysis of a peptide set, chosen for their differences in hydrophilicity, and the tryptic digests of bovine cytochrome c and β-lactoglobulin by hydrophilic interaction chromatography–electrospray ionisation mass spectrometry (HILIC–ESI-MS) is demonstrated. Two different types of HILIC phases, i.e., an amide- and an amino-modified silica-based phase, packed into narrow bore or capillary columns, were investigated with separations conducted under either low pH or neutral pH conditions. The separation performance of the two HILIC columns with respect to peak efficiency and selectivity have been documented under these different mobile phase conditions, and the results compared with the performance of a conventional capillary reversed-phase C18 column of similar dimensions. It was found that very good separation of the peptide set could be achieved by using the amide-modified silica column over a broad pH range. Moreover, with the protein digest samples, excellent separation of the tryptic digests was obtained with the amide-modified HILIC column under neutral pH conditions. Compared to the conventional reversed-phase C18 separations, the use of these HILIC columns not only provided complementary separation selectivity, but also offered the capability to identify unique peptides using tandem HILIC–mass spectrometric techniques. These studies therefore highlight the potential of HILIC procedures for future proteomic applications.  相似文献   

2.
In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations.  相似文献   

3.
Bioactive peptides and tryptic digests of various proteins were separated under acidic and alkaline conditions by ion-pair-reversed-phase high-performance liquid chromatography (RP-HPIPC) in 200 microm I.D. monolithic, poly(styrene-divinylbenzene)-based capillary columns using gradients of acetonitrile in 0.050% aqueous trifluoroacetic acid, pH 2.1, or 1.0% triethylamine-acetic acid, pH 10.6. Chromatographic performances with mobile phases of low and high-pH were practically equivalent and facilitated the separation of more than 50 tryptic peptides of bovine serum albumin within 15-20 min with peak widths at half height between 4 and 10 s. Neither a significant change in retentivity nor efficiency of the monolithic column was observed during 17-day operation at pH 10.6 and 50 degrees C. Upon separation by RP-HPIPC at high-pH, peptide detectabilities in full-scan negative-ion electrospray ionization mass spectrometry (negESI-MS) were about two to three times lower as compared to RP-HPIPC at low-pH with posESI-MS detection. Tandem mass spectra obtained by fragmentation of deprotonated peptide ions in negative ion mode yielded interpretable sequence information only in a few cases of relatively short peptides. However, in order to obtain sequence information for peptides separated with alkaline mobile phases, tandem mass spectrometry (MS/MS) could be performed in positive ion mode. The chromatographic selectivities were significantly different in separations performed with acidic and alkaline eluents, which facilitated the fractionation of a complex peptide mixture obtained by the tryptic digestion of 10 proteins utilizing off-line, two-dimensional RP-HPIPC at high pH x RP-HPIPC at low pH and subsequent on-line identification by posESI-MS/MS.  相似文献   

4.
On-line capillary electrophoresis (CE) separations are shown for a synthetic peptide mixture and a tryptic digest of human hemoglobin in an uncoated fused-silica capillary with detection using atmospheric pressure ionization mass spectrometry (API-MS). The CE system utilized a 1-m capillary column of either 75- or 100-microns I.D. These somewhat larger inside diameters allow higher sample capacities for MS detection and the 1-m length facilitates connecting the CE column to the liquid junction-ion spray interface and MS system. Low volatile buffer concentrations (15-20 mM) of ammonium acetate or ammonium formate, and high organic modifier content (5-50%) of methanol or acetonitrile facilitates ionization under electrospray conditions. This study shows that peptides separated by CE may be transferred to the API-MS system through a liquid junction coupling to the pneumatically assisted electrospray (ion spray) interface at low buffer pH when the electroosmotic flow is low (0-0.04 microliter/min). CE-MS as described herein is facilitated by features in modern CE instrumentation including robotic cleaning and pressurization of the capillary inlet. The latter is particularly useful for repetitive rinsing and conditioning of the capillary column between analyses in addition to continuous 'infusion' of sample to the mass spectrometer for tuning purposes. In addition to facile molecular weight determination, amino acid sequence information for peptides may be obtained by utilizing on-line tandem MS. After the tryptic digest sample components enter the API-MS system, the molecular ion species of individual peptides may be focussed and transmitted into the collision cell of the tandem triple quadrupole mass spectrometer. Collision-induced dissociation of protonated peptide molecules yielded structural information for their characterization following injection of 10 pmol of a tryptic digest from human hemoglobin.  相似文献   

5.
Amino acids residues are commonly submitted to various physicochemical modifications occurring at physiological pH and temperature. Post‐translational modifications (PTMs) require comprehensive characterization because of their major influence on protein structure and involvement in numerous in vivo process or signaling. Mass spectrometry (MS) has gradually become an analytical tool of choice to characterize PTMs; however, some modifications are still challenging because of sample faint modification levels or difficulty to separate an intact peptide from modified counterparts before their transfer to the ionization source. Here, we report the implementation of capillary zone electrophoresis coupled to electrospray ionization tandem mass spectrometry (CZE‐ESI‐MS/MS) by the intermediate of a sheathless interfacing for independent and highly sensitive characterization of asparagine deamidation (deaN) and aspartic acid isomerization (isoD). CZE selectivity regarding deaN and isoD was studied extensively using different sets of synthetic peptides based on actual tryptic peptides. Results demonstrated CZE ability to separate the unmodified peptide from modified homologous exhibiting deaN, isoD or both independently with a resolution systematically superior to 1.29. Developed CZE‐ESI‐MS/MS method was applied for the characterization of monoclonal antibodies and complex protein mixture. Conserved CZE selectivity could be demonstrated even for complex samples, and foremost results obtained showed that CZE selectivity is similar regardless of the composition of the peptide. Separation of modified peptides prior to the MS analysis allowed to characterize and estimate modification levels of the sample independently for deaN and isoD even for peptides affected by both modifications and, as a consequence, enables to distinguish the formation of l ‐aspartic acid or d ‐aspartic acid generated from deaN. Separation based on peptide modification allowed, as supported by the ESI efficiency provided by CZE‐ESI‐MS/MS properties, and enabled to characterize and estimate studied PTMs with an unprecedented sensitivity and proved the relevance of implementing an electrophoretic driven separation for MS‐based peptide analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
On-line immobilized metal affinity chromatography/capillary electrophoresis/electrospray ionization-mass spectrometry (IMAC/CE/ESI-MS) offers selective preconcentration of phosphorylated peptides with identification of the phosphorylated amino acid(s). The preconcentration provides low concentration limits of detection and capillary electrophoresis separates the peptides. Recently, we reported a fast, simple, and sensitive on-line IMAC/CE/ESI-MS/MS method for the determination of phosphopeptides at low-pmole levels. That work is expanded here by use of multiple stage tandem mass spectrometry (MS(n), n = 2,3) to isolate and fragment target ions to provide more reliable assignments of phosphorylated residues. The application of IMAC/CE/ESI-MS(n) is demonstrated by the analysis of tryptic digests of alpha- and beta-casein and in-gel tryptic digests of beta-casein.  相似文献   

7.
Various buffers (ammonium acetate, ammonium formate, and ammonium hydrogencarbonate), acids (formic acid, acetic acid, heptafluorobutyric acid, and trifluoroacetic acid), and bases (ammonium hydroxide and morpholine) covering the range from 2 to 11.5 have been investigated for their performance in the separation of proteins by reversed-phase liquid chromatography (RPLC) and in their detection by electrospray mass spectrometry (ESI-MS). These additives were first tested for the detection of standard proteins by ESI-MS by flow-injection analysis (FIA). Those additives yielding the highest signals were employed for the separation of standard proteins by using three different reversed-phase columns: two C18 columns (4.6 mm I.D. and 2.1 mm I.D.) and one perfusion column (2 mm I.D.). The sensitivity of the LC-MS system was evaluated with the column giving the best results and with those LC eluents enabling the LC separation of the proteins and also yielding the highest MS signals. For that purpose, calibration curves were compared for both LC-MS and FIA-MS. Formic acid was the additive yielding the highest responses in FIA-MS and trifluoroacetic acid (TFA) gave the best separation and recovery of the proteins. However, problems related to poor recovery of the proteins in the column when formic acid was used and the significant signal suppression observed in MS when TFA was employed, made neither of them suitable for the sensitive detection of the proteins in LC-MS.  相似文献   

8.
A method for the complete peptide mapping of the model integral membrane protein bacteri-orhodopsin is demonstrated. Utilizing more effective enzymatic digestion, procedures with capillary liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) and tandem mass spectrometry (MS/MS), all predicted tryptic digestion products were detected, as well as peptides from all previously reported post-translational modifications of bacteriorhodopsin. A significant contribution of chymotryptic-like digestion products was also observed. A characterization of the behavior of hydrophobic integral membrane peptides in a reversed-phase liquid chromatographic separation is also provided. The method reported here offers improved compatibility of the solubilizing reagents with both the chromatography and mass spectrometry, rendering it suitable for high-throughput proteomic applications.  相似文献   

9.
Extending the dynamic range of microcapillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) peptide sequencing methods is essential for extracting new discoveries from proteomic studies. The complexity of global protein digests and in vivo processed peptide repertoires (as isolated from immunologically important HLA complexes) have led to the development of novel separation methods to increase the number of peptides identified by a single analysis. Separation of complex mixtures by multidimensional high-performance liquid chromatography (HPLC) decreases the number of isolated peptides contained in each fraction and increases the likelihood of detecting low abundant peptides in a background of dominant signals. In this study, we have evaluated the use of two dimensions of reversed-phase chromatography for resolving and sequencing naturally processed HLA-A2 presented peptide repertoires. The first dimension of separation was reversed-phase chromatography using the strong ion pairing reagent trifluoroacetic acid (TFA) to ensure the highest efficiency of peptide fractionation. The second dimension of reversed-phase chromatography was online with an electrospray ionization (ESI) ion trap mass spectrometer. Mobile phases used for the second dimension of chromatography were modified with volatile reagents including a contemporary acetate-modified acidic solvent, which was compared with mobile phases prepared with ammonium hydroxide at an alkaline pH. As expected, we demonstrate improved separation of the HLA-A2 presented fractions using the alkaline pH conditions. However, less obvious was the improved peptide signal-to-noise detected for peptide signals by positive ion ESI ion trap mass spectrometric detection, which was attributed to a reduced chemical background when using the alkaline pH mobile phases that allowed the ion trap to fill with the peptide ions until the automatic gain control detected a full trap. The term 'wrong-way-round ionization' has been used to describe intense [M+H](+) ions generated during ESI under strongly basic solutions. Ultimately, a larger number of the HLA-A2 peptide repertoire was sequenced by coupling TFA-modified reversed-phase fractionation with alkaline-modified microcapillary LC/MS/MS analysis of each fraction. In the present report, we compare the two second-dimension approaches and demonstrate the quality of data that was acquired using alkaline pH reversed-phase conditions.  相似文献   

10.
Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF than reversed-phase packings that is scarcely dependent on the pH of the eluent. Applying a potential in gradient elution reversed-phase nano-LC of peptides shortens the analysis time as compared to separations without a potential. Electrically assisted reversed-phase gradient elution nano-LC is a powerful separation tool for analysis of tryptic digests. Peptides can be successfully resolved in acidic organic mobile phase at pH 2-3 with and without trifluoroacid as ion pairing reagent under isocratic conditions. It is demonstrated that CEC with mixed mode packing and an eluent of pH 2.3 with varying acetonitrile content can be applied to monitor impurities in a synthetic peptide.  相似文献   

11.
Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.  相似文献   

12.
Six amino acids with pIs that ranged from 3.2 to 9.7 were used as ampholytes to establish a pH gradient in capillary isoelectric focusing. This amino acid-based capillary isoelectric focusing (cIEF) was coupled with ESI-MS/MS using an electrokinetically pumped sheath-flow interface for peptide analysis. Amino acid-based isoelectric focusing generates a two-order of magnitude lower background signal than commercial ampholytes in the important m/z range of 300–1800. Good focusing was achieved for insulin receptor, which produced ∼10 s peak width. For 0.1 mg mL−1 bovine serum albumin (BSA) digests, 24 ± 1 peptides (sequence coverage 47 ± 4%) were identified in triplicate analysis. As expected, the BSA peptides were separated according to their pI. The concentration detection limit for the BSA digests is 7 nM and the mass detection limit is 7 fmole. A solution of six bovine protein tryptic digests spanning 5 orders of magnitude in concentration was analyzed by amino acid based cIEF-ESI-MS/MS. Five proteins with a concentration range spanning 4 orders of magnitude were identified in triplicate runs. Using amino acid based cIEF-ESI-MS/MS, 112 protein groups and 303 unique peptides were identified in triplicate runs of a RAW 264.7 cell homogenate protein digest. In comparison with ampholyte based cIEF-ESI-MS/MS, amino acid based cIEF-ESI-MS/MS produces higher resolution of five acidic peptides, much cleaner mass spectra, and higher protein spectral counts.  相似文献   

13.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

14.
The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium phosphate and ammonium borate on the MS signal of the proteins insulin, myoglobin, and bovine serum albumin (BSA) was investigated by employing infusion experiments, and compared to the effect of ammonium formate and formic acid. The study shows that with formic acid (50 mM, pH 2.4) the most intense protein signals were obtained, while the use of sodium phosphate buffer (5 and 10 mM, pH 7.5) almost completely diminished the MS response. Ammonium formate and ammonium borate (up to 100 mM, pH 8.5) also caused protein ion suppression, but especially with the borate buffer significant MS intensity remained. MS analysis of myoglobin revealed the loss of the heme group when an acidic CE electrolyte was used. Using a background electrolyte containing 25 mM ammonium borate (pH 8.5), it is demonstrated that a CE separation of a protein test mixture can be monitored with ESI-MS without degrading the MS performance allowing molecular weight determinations of the separated compounds. In the presence of borate, detection limits were estimated to be 5-10 microM (ca. 100 fmol injected). The usefulness of the CE-MS system employing a borate buffer is indicated by the analysis of a stored sample of BSA revealing several degradation products. A sample of placental alkaline phosphatase (PLAP), a potential therapeutic agent, was also analyzed by CE-MS indicating the presence of a protein impurity. Probably due to insufficient ionization of the PLAP (a complex glycoprotein), no MS signals of the intact protein were observed.  相似文献   

15.
The extent and effects of sequence scrambling in peptide ions during tandem mass spectrometry (MS/MS) have been examined using tryptic peptides from model proteins. Sequencescrambled b ions appeared in about 35% of 43 tryptic peptides examined under MS/MS conditions. In general, these ions had relatively low abundances with averages of 8% and 16%, depending on the instrumentation used. A few tryptic peptides gave abundant scrambled b ions in MS/MS. However, peptide and protein identifications under proteomic conditions with Mascot were not affected, even for these peptides wherein scrambling was prominent. From the 43 tryptic peptides that have been investigated, the conclusion is that sequence scrambling is unlikely to impact negatively on the accuracy of automated peptide and protein identifications in proteomics.  相似文献   

16.
Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.  相似文献   

17.
This article reports the results of a study carried out to evaluate the offline hyphenation of capillary zone electrophoresis with matrix-assisted lased desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) for the analysis of low-abundant complex samples, represented by the tryptic phosphorylated peptides of phosphoproteins, such as α-casein, β-casein, and fetuin. The proposed method employs a latex-coated capillary and consists in the online preconcentration of the tryptic peptides by a pH-mediated stacking method, their separation by capillary zone electrophoresis, and subsequent deposition of the separated analytes onto a MALDI target for their MS analysis. The online preconcentration method allows loading a large sample volume (~150?nL), which is introduced into the capillary after the hydrodynamic injection of a short plug of 1.0?M ammonium hydroxide solution and is sandwiched between two plugs of the acidic background electrolyte solution (BGE) filling the capillary. The sample spotting of the separated analytes onto the MALDI target is performed either during or postseparation using an automatic spotting device connected to the exit of the separation capillary. The proposed method allows the separation and identification of multiphosphorylated peptides from other peptides and enables their identification at femtomole level with improved efficiency compared with LC approaches hyphenated to MS.  相似文献   

18.
于冰  丛海林  刘虎威  李元宗  刘锋 《色谱》2005,23(5):487-491
采用毛细管电泳技术研究了重组促红细胞生长素(rhEPO)的分离问题。用N,N-二甲基六烷基溴化铵(6,6-ionene)涂层的毛细管测定了rhEPO中唾液酸的微多相性,同时采用毛细管电泳-质谱(CE-MS)联用技术在22 min内鉴定了rhEPO 20段胰酶消化肽中的11段。该方法简单快捷,重现性好,可用于蛋白质一级结构的测定。  相似文献   

19.
The relative reactivities of various naphthoquinone isomers (1,4-, 1,2- and 2-methyl-1,4-naphthoquinone) to two test proteins, apomyoglobin and human hemoglobin, were evaluated via liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS). The structural characterization of the resulting adducts was also obtained by LC/ESI-MS analysis of the intact proteins. The reactive sites of apomyoglobin and human hemoglobin with 1,4-naphthoquinone and 1,2-naphthoquinone were also identified through characterization of adducted tryptic peptides by use of high-pressure liquid chromatography/electrospray ionization with tandem mass spectrometry (HPLC/ESI-MS/MS), TurboSEQUEST, and the scoring algorithm for spectral analysis (SALSA). Four adducted peptides, which were formed by nucleophilic addition of a lysine amino acid residue to 1,4-naphthoquinone, were also identified, as was an adducted peptide from incubation of 1,2-naphthoquinone with apomyoglobin. In the case of incubation of human hemoglobin with the two naphthoquinones, two adducted peptides were identified from the N-terminal valine modification of the alpha and beta chains of human hemoglobin. The adducted protein formation may imply that naphthalene produces its in vivo toxicity through 1,2- and 1,4-naphthoquinone metabolites reacting with biomolecular proteins.  相似文献   

20.
王贤纯  梁宋平 《分析化学》2004,32(9):1219-1222
利用RP—HPLC/ESI—MS直接分析用芴甲氧羰基(Fmoc)固相多肽合成方法在PHB树脂上偶联合成的一个七肽(H2N—Tyr—Val—Asn-Thr-Asn—Met—Gly—COOH,Mr797.3)粗产物。RP—HPLC显示合成粗产物含有1个主成分,4个次要成分和多个微量成分;与之联用的电喷雾质谱则同步准确地测定出各成分的分子量(m/z)并自动对各主要成分的化学结构进行了串联质谱分析。结果证明,粗产物中的主成分即为目标七肽,另外几个主要副产物为七肽的氧化产物或残缺肽。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号