首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The dominant role played by flow injection/sequential injection (FI/SI, including lab-on-valve, LOV) in automatic on-line sample pretreatments coupling to various detection techniques is amply demonstrated by the large number of publications it has given rise to. Among these, its hyphenation with hydride/vapor generation atomic fluorescence spectrometry (HG/VG-AFS) has become one of the most attractive sub-branches during the last years, attributed not only to the high sensitivity of this technique, but also to the superb separation capability of hydride/vapor forming elements from complex sample matrices. In addition, it also provides potentials for the speciation of the elements of interest.It is worth mentioning that quite a few novel developments of sample pretreatment have emerged recently, which attracted extensive attentions from the related fields of research. The aim of this mini-review is thus to illustrate the state-of-the-art progress of implementing flow injection/sequential injection and miniaturized lab-on-valve systems for on-line hydride/vapor generation separation and preconcentration of vapor forming elements followed with detection by atomic fluorescence spectrometry, within the period from 2004 up to now. Future perspectives in this field are also discussed.  相似文献   

2.
Grudpan K 《Talanta》2004,64(5):1084-1090
This paper reviews some recent developments on cost-effective flow-based analysis. They include the newly developed Lab-at-Valve (LAV), concepts in using the stopped-flow injection approach, on-line sample pretreatment systems, including bead injection–flow injection and flow injection–ion-chromatography, systems for size-based speciation, and cost-effective reagents. Applications and advantages of such techniques are discussed.  相似文献   

3.
Sample introduction is a weak link in capillary electrophoresis (CE) systems, particularly when various pretreatments involving separation and modification of sample matrices are involved. Recently, the application of flow injection (FI) systems as a means of sample introduction and on-line sample pretreatment for CE has shown great potentials in improving the precision,reliability and throughput of CE systems. The advantages are discussed, illustrated by recent developments in the authors' group, including.  相似文献   

4.
Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.  相似文献   

5.
Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.  相似文献   

6.
Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.  相似文献   

7.
Within the last decade, the first generation of flow injection (FI) has been supplemented by sequential injection (SI), also termed the second generation, and, recently, by the third generation, i.e., SI-Lab-on-Valve (SI-LOV). As apparent from the literature, FI and/or SI have become dominant as substitutes for labor-intensive, manual, sample-pre-treatment and/or solution-handling procedures prior to analyte detection by inductively coupled plasma mass spectrometry (ICP-MS). The present review presents and discusses the progress of the state of the art in implementing miniaturized FI/SI systems for on-line matrix separation and pre-concentration of trace levels of metals with detection by ICP-MS. It highlights some of the frequently applied on-line, sample-pre-treatment schemes, including solid phase extraction (SPE), on-wall molecular sorption and precipitate/(co)-precipitate retention using a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn is interfaced to ICP-MS, as conducted in the present authors' group. It discusses the future outlook in this field.  相似文献   

8.
毛细管电泳进样技术新进展   总被引:2,自引:0,他引:2  
黄晓晶  杨秀荣 《分析化学》1998,26(10):1275-1279
评述了毛细管电泳进样技术新成果。对直接在线进样,二维分离体系中毛细管电泳分离的增样,相关毛细管电泳增样,超微量样品及单个分子的进样,近端进样,双向进样和高温下的进样装置的应用状况作了介绍。  相似文献   

9.
流动注射-毛细管电泳联用及应用进展   总被引:1,自引:0,他引:1  
流动注射是一种高效进样及在线溶液处理手段。毛细管电泳是一种高分离效率、高选择性的分析技术,但传统的毛细管电泳间歇式进样方式效率低且难用于过程分析,将流动注射进样技术与毛细管电泳结合,既弥补了毛细管电泳的进样缺陷,又可兼具两者的优点。有关两种技术的联用一直都在探索之中。文中对近年流动注射一毛细管电泳联用及应用研究进行了综述。  相似文献   

10.
Various flow sample handling approaches coupled to capillary electrophoresis (CE) are reviewed, covering the research in this field in the 12 years since the milestone year of 1997, when practical interfaces to on-line couple flow injection (FI) and capillary electrophoresis were first developed independently by two research groups. Some previous attempts are also presented. Since 1997 a plethora of ingenious coupled systems have been developed. Although several reviews are available on various aspects of the topic, we have opted for a comprehensive overview of all FI-CE systems, as well as related and similar systems. This coupling has thus also led to the development of systems based on hybrids between the classical and microchip approaches. Truly microchip FI-CE systems are also included in this review.The developed systems have been used for various sample treatments, including on-line membrane-assisted sample treatment, column-based preconcentration, on-line derivatization and monitoring, to name just a few. The utility of coupling flow sampling to CE has been demonstrated in various practical applications that are discussed in detail. The current state-of-the-art and foreseeable future developments are also discussed.  相似文献   

11.
This review aims to provide an account of the state-of-the-art, of recently introduced techniques and of future possibilities offered by flow analysis in order to automate sample pretreatment for electrothermal atomic absorption spectrometry (ETAAS). Topics such as on-line solid-liquid extraction, precipitation, coprecipitation, on-wall retention, solvent extraction and chemical vapor generation processes are used to illustrate the versatility of coupling flow injection (FI) for analyte separation and preconcentration in the flow system or in the atomizer. The use of FI to make the introduction of slurries and highly viscous samples easier is considered as well as on-line microwave sample digestion.  相似文献   

12.
Miró M  Estela JM  Cerdà V 《Talanta》2004,63(2):201-223
In the earlier parts of this series of reviews [1] and [2], the most relevant flowing stream techniques (namely, segmented flow analysis, continuous flow analysis, flow injection (FI) analysis, sequential injection (SI) analysis, multicommuted flow injection analysis and multisyringe flow injection analysis) applied to the determination of several core inorganic parameters for water quality assessment, such as nutrients and anionic species including nitrogen, sulfur and halogen compounds, were described.In the present paper, flow techniques are presented as powerful analytical tools for the environmental monitoring of metal ions (alkaline and alkaline-earth metals, and elemental and harmful transition metals) as well as to perform both multielemental and speciation analysis in water samples. The potentials of flow techniques for automated sample treatment involving on-line analyte separation and/or pre-concentration are also discussed in the body of the text, and demonstrated for each individual ion with a variety of strategies successfully applied to trace analysis. In this context, the coupling of flow methodologies with atomic spectrometric techniques such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), inductively coupled plasma mass spectrometry (ICPMS) or hydride-generation (HG)/cold-vapor (CV) approaches, launching the so-called hyphenated techniques, is specially worth mentioning.  相似文献   

13.
A flow injection (FI) in-valve-mini-column packed with Chelex-100 resin is proposed for on-line sample pretreatment for some metal ions, namely, Cd(II), Pb(II) and Zn(II), prior to simultaneous determination using ion chromatography (IC). A solution containing a mixture of the cations was first passed through the in-valve-mini-column, followed by on-line elution. The eluate was then flowed further to an injection valve and was injected into an ion chromatograph. Conditions of the system were optimized. A single standard calibration was possible. The recoveries of cations were found to be in the range of 95–105%. The developed method was applied to the accurate analysis of zinc ore samples.  相似文献   

14.
Flow injection (FI) on-line separation and preconcentration systems for electrothermal atomic absorption spectrometry (ETAAS) are reviewed, highlighting the main developments in the field since 1990 and work achieved in the authors' laboratory. These include developments in on-line preconcentration systems based on column techniques, solvent extraction, coprecipitation and hydride sequestration. Advantages, limitations and potentials of the FI-ETAAS combination are discussed.  相似文献   

15.
Chen Y  Lü W  Chen X  Hu Z 《Electrophoresis》2007,28(1-2):33-44
The technique of combined flow injection CE (FI-CE) integrates the essential favorable merits of FI and CE and can significantly expand the application of CE by utilizing the various on-line sample pretreatments and preconcentration of FI. The basic principles, instrumental developments, and applications of the FI-CE system from 2004 to 2006 are reviewed. The recent developments and applications of FI-CE are outlined.  相似文献   

16.
Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil-containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the partitioning of inorganic phosphorus in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump.

Three different soil phase associations for phosphorus, that is, exchangeable, Al- and Fe-bound, and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the three steps of the Hieltjes–Lijklema (HL) scheme involving the use of 1.0 M NH4Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents. The precise timing and versatility of SI for tailoring various operational extraction modes were utilized for investigating the extractability and the extent of phosphorus re-distribution for variable partitioning times.

Automatic spectrophotometric determination of soluble reactive phosphorus in soil extracts was performed by a flow injection (FI) analyser based on the Molybdenum Blue (MB) chemistry. The 3σ detection limit was 0.02 mg P L−1 while the linear dynamic range extended up to 20 mg P L−1 regardless of the extracting media. Despite the variable chemical composition of the HL extracts, a single FI set-up was assembled with no need for either manifold re-configuration or modification of chemical composition of reagents.

The mobilization of trace elements, such as Cd, often present in grazed pastures as a result of the application of phosphate fertilizers, was also explored in the HL fractions by electrothermal atomic absorption spectrometry.  相似文献   


17.
Flow injection (FI) on-line separation and preconcentration systems for electrothermal atomic absorption spectrometry (ETAAS) are reviewed, highlighting the main developments in the field since 1990 and work achieved in the authors laboratory. These include developments in on-line preconcentration systems based on column techniques, solvent extraction, coprecipitation and hydride sequestration. Advantages, limitations and potentials of the FI-ETAAS combination are discussed.  相似文献   

18.
第三代流动注射分析-"阀上实验室"的现状与趋势   总被引:2,自引:0,他引:2  
王建华  方肇伦 《分析化学》2004,32(10):1401-1406
介绍了第三代流动注射分析-“阀上实验室(Lab-on-Valve,LOV)”分析系统,综述了其在生化分析及微型化样品在线预处理技术中的最新应用,包括阀内免疫分析和生物化学反应的实时分子光谱检测、阀内微珠注射(bead injection,BI)及微珠载液的流控、阀内可更新表面微型填充柱固相萃取分离富集技术与电热原子吸收光谱(ETAAS)及诱导耦合等离子体质谱(ICPMS)的联用等。还展望了“阀上实验室”技术的应用前景,并提出了介观流控分析系统的概念。  相似文献   

19.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been coupled to in vivo microdialysis for on-line monitoring of melatonin in a freely moving rat for a period of 15 hours. A microdialysis probe was surgically implanted into the jugular vein of the rat, and deionized water was used as the perfusion medium at a flow rate of 1.0 microL/min. Microdialysis samples were collected in an on-line injector with sample injection every 30 minutes. Melatonin was dosed by intraperitoneal (i.p.) injection and then monitored by microdialysis/LC/MS/MS. The whole experiment, including the microdialysis sampling and sample injection into the LC/MS system, was fully automated. Metabolites of melatonin were identified off-line by LC/MSn experiments. Two metabolites were identified as 6-hydroxymelatonin and cyclic 2-hydroxymelatonin, consistent with ones found previously in the literature.  相似文献   

20.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号