1.
Mass spectrometry has gained prominence in limited proteolysis studies largely due to its unparalleled precision in determining protein molecular mass. However, proteolytic fragments usually cannot be identified through direct mass measurement, since multiple subsequences of a protein can frequently be matched to observed masses of proteolytic fragments. Therefore, additional information from N-terminal sequencing is often needed. Here we demonstrate that mass spectrometry analysis of the time course of limited proteolysis reactions provides new information that is self-sufficient to identify all proteolytic fragments. The method uses a non-specific protease like subtilisin and exploits information contained in the time-resolved dataset such as: increased likelihood of identifying larger fragments generated during initial proteolysis solely by their masses, additivity of the masses of two mutually exclusive sequence regions that generate the full-length molecule (or an already assigned subfragment), and analyses of the proteolytic subfragment patterns that are facilitated by having established the initial cleavage sites. We show that the identities of the observed proteolytic fragments can be determined by LC/MS alone because enough constraints exist in the time-resolved dataset. For a medium-sized protein, it takes about 8 h to complete the study, a significant improvement over the traditional SDS-PAGE and N-terminal sequencing method, which usually takes several days. We illustrate this method with application to the catalytic domain of mitogen-activated protein kinase-activated protein kinase-2, and compare the results with N-terminal sequencing data and the known X-ray crystal structure.  相似文献   

2.
In a previous report (Young et al., Proc. Natl. Acad. Sci. U.S.A. 2000, 97, 5802-5806), we provided a proof-of-principle for fold recognition of proteins using a homobifunctional amine-specific chemical crosslinking reagent in combination with mass spectrometry analysis and homology modeling. In this current work, we propose a systematic nomenclature to describe the types of peptides that are generated after proteolysis of crosslinked proteins, their fragmentation by tandem mass spectrometry, and an automated algorithm for MS/MS spectral assignment called "MS2Assign." Several examples are provided from crosslinked peptides and proteins including HIV-integrase, cytochrome c, ribonuclease A, myoglobin, cytidine 5-monophosphate N-acetylneuraminic acid synthetase, and the peptide thymopentin. Tandem mass spectra were obtained from various crosslinked peptides using post source decay MALDI-TOF and collision induced dissociation on a quadrupole-TOF instrument, along with their automated interpretation using MS2Assign. A variety of possible outcomes are described and categorized according to the number of modified lysines and/or peptide chains involved, as well as the presence of singly modified (dead-end) lysine residues. In addition, the proteolysis and chromatographic conditions necessary for optimized crosslinked peptide recovery are presented.  相似文献   

3.
An algorithm for reducing the time necessary to match a large set of peptide tandem mass spectra with a list of protein sequences is described. This algorithm breaks the process into multiple steps. A rapid survey step identifies all protein sequences that are reasonable candidates for a match with a set of tandem mass spectra. These candidates are then used as models, which are refined by detailed analysis of the set of tandem mass spectra for evidence of incomplete enzymatic hydrolysis, non-specific hydrolysis and chemical modifications of amino acid residues resulting from either post-translational modifications or sample handling. Compared with current one-step methods for matching proteins to mass spectra, this multiple-step method can decrease the time required for the calculation by several orders of magnitude.  相似文献   

4.
The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards.  相似文献   

5.
A strategy for increasing the efficiency of protein crystallization/structure determination with mass spectrometry has been developed. This approach combines insights from limited proteolysis/mass spectrometry and crystallization via in situ proteolysis. The procedure seeks to identify protease-resistant polypeptide chain segments from purified proteins on the time-scale of crystal formation, and subsequently crystallizing the target protein in the presence of the optimal protease at the right relative concentration. We report our experience with 10 proteins of unknown structure, two of which yielded high-resolution X-ray structures. The advantage of this approach comes from its ability to select only those structure determination candidates that are likely to benefit from application of in situ proteolysis, using conditions most likely to result in formation of a stable proteolytic digestion product suitable for crystallization.  相似文献   

6.
The amino acid sequences of mouse monoclonal antibodies have been characterized completely by mass spectrometry. Antibodies used in the present study were derived from mouse switch variant cell lines that produce four kinds of immunoglobulin Gs (IgGs). The amino acid sequences of these antibodies had not been estimated from the corresponding DNA sequence, so the sequences of IgGs derived from other strains were used as references in this study. Intra- and interchain disulfide bonds of the IgGs were reduced and carboxymethylated and the products were subjected to proteolytic digestion. The existence of N-linked oligosaccharides also was taken into account. The capabilities and limitations of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry and capillary liquid chromatography-electrospray ionization mass spectrometry are discussed in the structural characterization of the antibodies. Based on our results, allotypes of the antibodies examined are discussed. This study shows that amino acid sequences of proteins, such as IgG, can be investigated without information about the corresponding DNA sequence if appropriate reference sequences derived from other strains can be used.  相似文献   

7.
The structural characterization of proteins and peptides isolated in minute quantities requires the most efficient use of available sample. A mass spectrometer data system was programmed to continuously evaluate incoming liquid chromatography/mass spectrometry data against a user-defined array of information. The resulting conclusions were used to automatically set and modify acquisition parameters in real time to collect collision-induced dissociation spectra for selected ions (tandem mass spectrometry). This approach has provided a mechanism to target specific subsets of masses in a complex mixture and/or to discriminate selectively against masses that are known or not of interest. Masses of contaminants or peptide masses derived from known proteins can be automatically recorded and removed from further consideration for collision-induced dissociation analysis. Once recorded, these “libraries” of masses can be used across multiple analyses. This technique directs the mass spectrometer data system to focus on the analysis of masses significant to the user, even if their signal intensities are well below the intensities of contaminating masses. When combined with a database search program to correlate tandem mass spectra to known protein sequences, the identity of the protein can be established unequivocally by using less than 100 fmol of sample.  相似文献   

8.
The ability to detect protein variants and post-translational modifications by mass spectrometry has become increasingly important. Unfortunately, the ability to detect variants in large intact proteins (>80,000 Da) is limited. Even in the analysis of smaller proteins, algorithms are required to determine the presence of a 2 Da mass shift in an intact 13 kDa protein because the isotopic distribution of the multiply charged ions of the variant overlaps the wild-type distribution. Fortunately, most modern instruments are capable of detecting variants in tryptic peptides derived from intact proteins. If a single common variant protein is known, the presence of a variant tryptic peptide can be easily demonstrated. A more difficult issue is the case where a multiplicity of peptides with multiple amino acid substitutions can be associated with pathology. In these cases a decrease in the relative amount of a variant peptide relative to other internal tryptic fragments would be diagnostic. However, the variability associated with the analysis of in-gel or solution digests of proteins, related to efficiencies in digestion, extraction and ionization, confounds variant analysis at the peptide level. A strategy was developed to normalize for this variability by utilizing multiple isotopically labeled internal standards for multiple peptides derived from the same protein. Erythrocyte spectrin from 36 normal and 25 abnormal osmotic fragility samples was analyzed as a test case. Three isotopically labeled target peptides comprising the alpha/beta-spectrin self-association sites were added to purified digested alpha-spectrin. The utilization of multiple internal standards demonstrates the capability to normalize for sample variability due to ionization efficiency, solvent effects, digestion and extraction efficiency.  相似文献   

9.
周艳卿  蒋小岗 《色谱》2016,34(8):752-756
Edman降解是最早建立的一种用于多肽和蛋白质氨基端测序的方法,该方法现在仍被广泛用于生物化学领域。随着高通量蛋白质组学技术的发展和应用,该方法中的异硫氰酸苯酯反应被用于修饰蛋白质氨基端,并用于检测蛋白质水解位点。但还没有异硫氰酸苯酯是否可以修饰其他氨基酸侧链并影响多肽序列分析的研究。为了探究其修饰其他氨基酸的可能性,本文利用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS)和液相色谱-串联质谱(LC-MS/MS)研究了异硫氰酸苯酯对一个模型肽的化学修饰。质谱数据解析后发现在高浓度异硫氰酸苯酯的反应条件下,组氨酸上可以引入一个新的异硫氰酸苯酯修饰位点。这一修饰位点的发现预示着通过改变实验条件或分析方法,可以更准确地利用Edman降解和蛋白质组学技术分析多肽和蛋白质。  相似文献   

10.
11.
Sample preparation is crucial to the success of experiments in biological mass spectrometry. In proteomics, digestion of the proteins into peptides is a key step for “bottom-up” approaches. Often, the use of enzymes requires physiological conditions, producing peptides that must be extracted or further purified before mass analysis. Chemical cleavage reagents offer more flexibility and can be more compatible with downstream mass analysis. Expanding on prior work using acid hydrolysis, proteolysis with matrix-assisted laser desorption ionization (MALDI) matrices is presented. This sample preparation can be performed rapidly with a minimum of reagents and sample handling, but it must first be evaluated in terms of digestion efficiency, missed cleavages, and side reactions before implementation for in-gel digestion and in-solution digestion using minimal volumes of protein. Time courses of acid hydrolysis are shown for protein standards, illustrating the sensitivity of this type of sample preparation, minimization of side reactions, and performance for proteins in mixtures. To illustrate the potential for sensitive detection of a specific protein, MALDI matrix hydrolysis is used to digest a protein immunoprecipitated from cell lysate.  相似文献   

12.
In the last decade, mass spectrometry has been employed by more and more researchers for identifying the proteins in a macromolecular complex as well as for defining the surfaces of their binding interfaces. This characterization of protein-protein interfaces usually involves at least one of several different methodologies in addition to the actual mass spectrometry. For example, limited proteolysis is often used as a first step in defining regions of a protein that are protected from proteolysis when the protein of interest is part of a macromolecular complex. Other techniques used in conjunction with mass spectrometry for determining regions of a protein involved in protein-protein interactions include chemical modification, such as covalent cross-linking, acetylation of lysines, hydrogen-deuterium exchange, or other forms of modification. In this report, both limited proteolysis and chemical modification were combined with several mass spectrometric techniques in efforts to define the protein surface on the HIV core protein, p24, recognized by two different monoclonal human antibodies that were isolated from HIV+ patients. One of these antibodies, 1571, strongly inhibits the CD4+ T cell proliferative response to a known epitope (PEVIPMFSALSEGATP), while the other antibody, 241-D, does not inhibit as strongly. The epitopes for both of these antibodies were determined to be discontinuous and localized to the N-terminus of p24. Interestingly, the epitope recognized by the strongly inhibiting antibody, 1571, completely overlaps the T cell epitope PEVIPMFSALSEGATP, while the antibody 241-D binds to a region adjacent to the region of p24 recognized by the antibody 1571. These results suggest that, possibly due to epitope competition, antibodies produced during HIV infection can negatively affect CD4+ T cell-mediated immunity against the virus.  相似文献   

13.
Park S  Jo K  Oh HB 《The Analyst》2011,136(18):3739-3746
A zinc-finger motif recognizes specific sequences on the double helical structure of DNA. This sequence recognition property offers great promise for various biotechnology applications. Accordingly, it is crucially important to characterize zinc-finger binding characteristics for further developments. Although the gel shift assay or phage display is traditionally used for determining the binding characteristics of zinc-fingers for double stranded DNA, in the present study we utilize electrospray ionization mass spectrometry as an advanced and convenient characterization tool because of the rich information it provides, and its quantitative sensitivity, operational simplicity, and no need for radioactive labeling. Here we demonstrate the use of negative-ion electrospray ionization mass spectrometry for competition-based quantitative comparison of the zinc-finger motif sequence specificity, stoichiometry, and metal ion dependence.  相似文献   

14.
Covalent labeling and mass spectrometry are seeing increased use together as a way to obtain insight into the 3-dimensional structure of proteins and protein complexes. Several amino acid specific (e.g., diethylpyrocarbonate) and non-specific (e.g., hydroxyl radicals) labeling reagents are available for this purpose. Diethylpyrocarbonate (DEPC) is a promising labeling reagent because it can potentially probe up to 30% of the residues in the average protein and gives only one reaction product, thereby facilitating mass spectrometric analysis. It was recently reported, though, that DEPC modifications are labile for some amino acids. Here, we show that label loss is more significant and widespread than previously thought, especially for Ser, Thr, Tyr, and His residues, when relatively long protein digestion times are used. Such label loss ultimately decreases the amount of protein structural information that is obtainable with this reagent. We find, however, that the number of DEPC modified residues and, thus, protein structural information, can be significantly increased by decreasing the time between the covalent labeling reaction and the mass spectrometric analysis. This is most effectively accomplished using short (e.g., 2 h) proteolytic digestions with enzymes such as immobilized chymotrypsin or Glu-C rather than using methods (e.g., microwave or ultrasonic irradiation) that accelerate proteolysis in other ways. Using short digestion times, we show that the percentage of solvent accessible residues that can be modified by DEPC increases from 44% to 67% for cytochrome c, 35% to 81% for myoglobin, and 76% to 95% for β-2-microglobulin. In effect, these increased numbers of modified residues improve the protein structural resolution available from this covalent labeling method. Compared with typical overnight digestion conditions, the short digestion times decrease the average distance between modified residues from 11 to 7 Å for myoglobin, 13 to 10 Å for cytochrome c, and 9 to 8 Å for β-2-microglobulin.  相似文献   

15.
Patient‐derived 3D organoids show great promise for understanding patient heterogeneity and chemotherapy response in human‐derived tissue. The combination of organoid culture techniques with mass spectrometry imaging provides a label‐free methodology for characterizing drug penetration, patient‐specific response, and drug biotransformation. However, current methods used to grow tumor organoids employ extracellular matrices that can produce small molecule background signal during mass spectrometry imaging analysis. Here, we develop a method to isolate 3D human tumor organoids out of a Matrigel extracellular matrix into gelatin mass spectrometry compatible microarrays for high‐throughput mass spectrometry imaging analysis. The alignment of multiple organoids in the same z‐axis is essential for sectioning organoids together and for maintaining reproducible sample preparation on a single glass slide for up to hundreds of organoids. This method successfully removes organoids from extracellular matrix interference and provides an organized array for high‐throughput imaging analysis to easily identify organoids by eye for area selection and further analysis. With this method, mass spectrometry imaging can be readily applied to organoid systems for preclinical drug development and personalized medicine research initiatives.  相似文献   

16.
Deamidation of asparagine and spontaneous isomerization of aspartic acid in proteins and peptides occur frequently. These modifications result in a mixture of peptide variants containing all three residues in the sequences. Identification and isomer quantification for these systems are challenging tasks for tandem mass spectrometry commonly utilized in protein analysis. Chromatographic data provide a set of sequence-specific information complementary to mass spectrometry. In order to compare measured retention times (RTs) with those calculated from the sequences derived from protein databases, it is necessary to develop chromatographic models and tools allowing the prediction of RT and elution order for peptides with modified residues. In this work we extended recently introduced critical liquid chromatography of biomacromolecule model for prediction of RTs for peptides containing asparagines, aspartic acid, and isoaspartic acid residues.  相似文献   

17.
Epitope extraction technique is based on the specific digestion of a target protein followed by immunoaffinity isolation of a specific recognition peptide. This technique, in combination with mass spectrometry, has been efficiently used for epitope identification. The major goal of this work was to utilize newly developed enzyme and immunoaffinity magnetic reactors for the epitope extraction procedure and confirm the efficiency of this improved system for epitope screening of proteins. Alginic acid-coated magnetite microparticles with immobilized TPCK-trypsin provided high working efficiency with low non-specific adsorption, digestion time in minutes and low frequency of missed cleavages. The sensitivity and specificity of tryptic fragmentation of the beta-amyloid-peptide Abeta (1-40) as a model polypeptide was confirmed by Fourier-transform ion cyclotron resonance mass spectrometry analysis. The Sepharose reactor or immunoaffinity magnetic reactors, both with anti-amyloid-beta monoclonal antibodies, were used for specific isolation and identification of target peptides. In this way, the epitope extraction technique combined with mass spectrometric analysis is shown to be an excellent base for molecular screening of potential vaccine lead proteins.  相似文献   

18.
Mass spectrometry has made important contributions to the field of immunology in the past decade. A variety of mass spectrometric-based techniques have been applied to study the structures of macromolecules that play a vital role in the immune response. These include traditional molecular mass measurements to identify post-translational modifications and structural heterogeneity, mass mapping of proteolysis products, sequencing by tandem mass spectrometry and conformational analysis. Antigen-antibody and other immune complexes have been detected by mass spectrometry, providing an avenue to study macromolecular assemblies that are important to immune function. By virtue of the ability of mass spectrometry based techniques to analyze complex biological mixtures, mass spectrometry has also been employed to identify and sequence protein epitopes important in both the humoral and cellular immune responses. This has been achieved through a combination of immunoaffinity and mass spectrometric techniques, and the coupling of high-performance chromatographs to mass spectrometers. These approaches are important for the identification of pathogens and show promise for the early diagnosis of disease associated with viral and bacterial infection and malignancy. These investigations will enable the mechanisms associated with normal and impaired immune function to be elucidated. Mass spectrometry has been utilized to characterize the structure of peptide mimics, multiple antigenic peptides and other constructs in the design of synthetic immunogens. Information derived from these studies will aid in the development of novel therapeutics and vaccines.  相似文献   

19.
We demonstrate that the microwave-assisted protein enzymatic digestion (MAPED) method can be successfully applied to the mass spectrometric characterization of proteins captured on the affinity surfaces of protein chips. The microwave-assisted on-chip tryptic digestion method was developed using a domestic microwave, completing the on-chip proteolysis reaction in minutes, whereas the previous on-chip digestion methods by incubation took hours of incubation time. For the model protein chips, antibody-presenting surfaces were prepared, where anti-α-tubulin1 and antibovine serum albumin (BSA) were immobilized on self-assembled monolayers. The resulting digestion efficiency, displaying sequence coverages of 30 and 14% for α-tubulin1 and BSA, respectively, was comparable to the previous time-consuming incubation studies. It allowed the characterization of immunosensed proteins by MASCOT search using peptide mass fingerprinting. In an example of this method for protein chip applications, BSA naturally involved in fetal bovine serum was unambiguously identified on a model protein chip by imaging mass spectrometry. This work shows that biomass spectrometry techniques can be implemented for surface mass spectrometry and biochip applications. Along with recent advances in imaging mass spectrometry, this technique will provide a new opportunity for high-speed, and thus high-throughput in the future, label-free mass spectrometric assays using protein arrays.  相似文献   

20.
A method is presented for the structural characterization of proteins separated by two-dimensional poly-acrylamide gel electrophoresis (2D-PAGE). The method includes separation of a protein mixture by 2D-PAGE, recovery of proteins from the gel spots revealed by copper staining and analysis of the proteins by triple-stage quadrupole mass spectrometry using an electrospray ionization interface (ESI-TSQMS). Prior to the mass spectrometric analysis, the extracted proteins were passed through a small reversed-phase column (10 × 4.0 mm I.D.) to remove salts and gel-derived contaminants and then introduced into the mass spectrometer through a reversed-phase capillary column with 0.25 mm I.D. Application of the method to the analysis of rat cerebellar proteins suggests that the molecular mass could be accurately determined with sub-picomole amounts of protein samples derived from one or two 2D gels. The method was also useful for peptide mapping and determination of amino acid sequences of proteins micro-prepared from the 2D gel. Because 2D-PAGE has an excellent resolving power in protein separation and because capillary LC-ESI-TSQMS provides structural information with very small amounts of samples, the combined system of 2D-PAGE and capillary LC-ESI-TSQMS described here should allow wide applications to molecular studies of genes and proteins, such as identifications of protein spots on 2D gels, confirmation of gene/protein sequences and analysis of post-translational modification of proteins present naturally in tissue/cell extracts or expressed by recombinant DNA techniques.  相似文献   